Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CANDIDATES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Synergies between H, He and radiation damage in dual and triple ion irradiation of candidate fusion blanket materials

Three ferritic/martensitic alloys were studied to understand the synergistic effect between single ion beam (Fe 2+ ), dual ion beam (Fe 2+ +He 2+ and Fe 2+ +H + ), and triple ion beam (Fe 2+ +He 2+ +H + ) irradiations on cavity evolution. A commercial alloy, F82H, a castable nanostructured alloy, CNA3, and a high purity model alloy, Fe8Cr2W, were irradiated at 400°C to 600°C to a damage level of 50 dpa at a damage rate of 1 × 10 –3 dpa/s with He and H injection rates of 10 and 40 appm/dpa, respectively. Post-irradiation characterization via bright field transmission electron microscopy and high-angle annular dark-field scanning transmission electron microscopy was performed on all irradiated conditions to characterize the cavity size distribution and determine the effects of H/He injection on cavity microstructure. In all three alloys, hydrogen co-injection with helium resulted in an increased cavity number density and maximum cavity size, producing an increase in swelling over that from helium injection alone. Swelling in F82H appears to peak between 450°C and 500°C. At 600°C, swelling was minimal and cavities of high density and small size were confined to grain boundaries and dislocations while at 400°C, swelling is also low with a nearly homogeneous, high density, distribution of very small cavities throughout. Swelling was least in the commercial alloy F82H due to the high sink strength. The CNA3 alloy underwent dissolution of precipitates that lowered the sink strength and resulted in higher swelling than F82H, but less than the model alloy. Electron energy loss spectroscopy (EELS) elemental mapping revealed hydrogen forming a halo-like structure about the periphery of the cavities and helium residing within the cavities themselves. Finally, this observation suggests that hydrogen reduces the surface energy of helium-filled cavities which results in both increased cavity number density and cavity size in triple beam irradiation over dual beam irradiation.

36 MATERIALS SCIENCE↗

A candidate accident tolerant fuel system based on a highly concentrated alloy thin film

The feasibility of depositing a thin film of highly concentrated alloy on zircaloy-4 substrates at low temperatures was investigated. Electron microscopy characterisation at micro and nanoscales showed that the deposited thin film is near-equiatomic, single-phase and with all alloying elements uniformly distributed throughout the microstructure. Heavy-ion irradiations carried out in situ within a transmission electron microscope displayed the generation of both defect clusters and inert gas bubbles at around 1.5 × 10 16 ions·cm –2 (15.4 dpa). Post-irradiation characterisation demonstrated that the thin film preserved its solid solution and that, under the studied conditions, no elemental segregation or phase transformations were observed, indicating a high radiation tolerance.

36 MATERIALS SCIENCE↗

Bayesian automated weighting of aggregated DFT, MD, and experimental data for candidate thermodynamic models of aluminum with uncertainty quantification

Atomic-scale modeling methods such as density functional theory (DFT) and molecular dynamics (MD) can predict the thermodynamic properties of materials at a lower cost than experimental measurements. However, their regular usage in thermodynamic model construction is hampered by the lack of quantitative agreement with experimental measurements and the lack of uncertainty estimates on the data. To make regular usage of this atomistic simulation data, it is important to assess whether the atomistic simulation datasets, by themselves or in combination with experimental measurements, result in the same physics-informed models best supported by experimental measurements alone. Here, models of aluminum thermodynamic properties are discussed using three data sources: atomistic calculations (DFT and MD), experiments, and a combination of atomistic calculations and experiments. The study shows that, after ensuring self-consistency in predicting key invariant points, both experimental measurements and atomistic calculations can significantly contribute to an optimal model.

36 MATERIALS SCIENCE↗

Test of candidate light distributors for the muon (g−2) laser calibration system

The new muon ( g −2) experiment E989 at Fermilab will be equipped with a laser calibration system for all the 1296 channels of the calorimeters. An integrating sphere and an alternative system based on an engineered diffuser have been considered as possible light distributors for the experiment. We present here a detailed comparison of the two based on temporal response, spatial uniformity, transmittance and time stability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Geant4 evaluation of the Hornyak button and two candidate detectors for the TREAT hodoscope

The performance of traditional Hornyak buttons and two proposed variants for fast-neutron hodoscope applications was evaluated using Geant4. The Hornyak button is a ZnS(Ag)-based device previously deployed at the Idaho National Laboratory's TRansient REActor Test Facility (better known as TREAT) for monitoring fast neutrons emitted during pulsing of fissile fuel samples. Past use of these devices relied on pulse-shape discrimination to reduce the significant levels of background Cherenkov radiation. Proposed are two simple designs that reduce the overall light guide mass (here, polymethyl methacrylate or PMMA), employ silicon photomultipliers (SiPMs), and can be operated using pulse-height discrimination alone to eliminate background noise to acceptable levels. Geant4 was first used to model a traditional Hornyak button, and for assumed, hodoscope-like conditions, an intrinsic efficiency of 0.35% for mono-directional fission neutrons was predicted. The predicted efficiency is in reasonably good agreement with experimental data from the literature and, hence, served to validate the physics models and approximations employed. Geant4 models were then developed to optimize the materials and geometries of two alternatives to the Hornyak button, one based on a homogeneous mixture of ZnS(Ag) and PMMA, and one based on alternating layers of ZnS(Ag) and PMMA oriented perpendicular to the incident neutron beam. For the same radiation environment, optimized, 5-cm long (along the beam path) devices of the homogeneous and layered designs were predicted to have efficiencies of approximately 1.3% and 3.3%, respectively. For longer devices, i.e., lengths larger than 25 cm, these efficiencies were shown to peak at approximately 2.2% and 5.9%, respectively. Furthermore, both designs were shown to discriminate Cherenkov noise intrinsically by using an appropriate pulse-height discriminator level, i.e., pulse-shape discrimination is not needed for these devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of candidate secondary electron emission materials.

Secondary electron emission (SEE) yields obtained with empirical models deviate significantly from experiment. Therefore they cannot be used to predict the SEE data for various materials. The angular dependencies of SEE in empirical models are also drastically different and inconvenient for comparison. SEE coefficients were calculated by a theoretical method that uses Monte Carlo simulation, empirical theories, and close comparison to experiment, in order to parameterize the SEE yields of highly emissive materials. We have successfully applied this method to bulk Al{sub 2}O{sub 3}, a highly emissive material for micro-channel plates, as well as to thinly deposited films of Al{sub 2}O{sub 3}. The simulation results will be used in the selection of an emissive material, and if the emission yield of the material is small, as a resistive material for the deposition and characterization experiments that will be conducted by a large-area fast detector project at Argonne National Laboratory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radioarsenic: A promising theragnostic candidate for nuclear medicine

Molecular imaging is a non-invasive process that enable the visualization, characterization, and quantitation of biological processes at the molecular and cellular level. With the emergence of theragnostic agents to diagnose and treat disease for personalized medicine there is a growing need for matched pairs of isotopes. Matched pairs offer the unique opportunity to obtain patient specific information from SPECT or PET diagnostic studies to quantitate in vivo function or receptor density to inform and tailor therapeutic treatment. There are several isotopes of arsenic that have emissions suitable for either or both diagnostic imaging and radiotherapy. Their half-lives are long enough to pair them with peptides and antibodies which take longer to reach maximum uptake to facilitate improved patient pharmacokinetics and dosimetry then can be obtained with shorter lived radionuclides. Arsenic-72 even offers availability from a generator that can be shipped to remote sites and thus enhances availability. Arsenic has a long history as a diagnostic agent, but until recently has suffered from limited availability, lack of suitable chelators, and concerns about toxicity have inhibited its use in nuclear medicine. However, new production methods and novel chelators are coming online and the use of radioarsenic in the pico and nanomolar scale is well below the limits associated with toxicity. This manuscript will review the production routes, separation chemistry, radiolabeling techniques and in vitro/in vivo studies of three medically relevant isotopes of arsenic (arsenic-74, arsenic-72, and arsenic-77).

07 ISOTOPE AND RADIATION SOURCES↗

ESR studies on the spin-liquid candidate κ-(BEDT-TTF)2Cu2(CN)3: Anomalous response below T=8K

The organic conductor kappa-(BEDT-TTF)(2)Cu-2(CN)(3) seems to form a quantum spin liquid, although at low temperatures unusual properties are seen in the charge, spin and lattice degrees of freedom. Here we report results of X-band ESR studies of kappa-(BEDT-TTF)(2)Cu-2(CN)(3) single crystals as a function of temperature and angle. We find indications of two anisotropic relaxation mechanisms at low temperatures and compare them to the spin-liquid behavior observed in other strongly correlated systems. In addition, we can recognize charge inhomogeneities in the copper ions of the anion layer. This disorder might be linked to the dielectric response measured in this compound.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An effect of Sm vacancies on the hybridization gap in topological Kondo insulator candidate SmB 6

A necessary element for the predicted topological state in Kondo insulator SmB 6 is the hybridization gap which opens in this compound at low temperatures. Here, in this work, we present a comparative study of the in-gap density of states due to Sm vacancies by Raman scattering spectroscopy and heat capacity for samples where the number of Sm vacancies is equal to or below 1%. We demonstrate that hybridization gap is very sensitive to the presence of Sm vacancies. Lastly, at the amount of vacancies above 1% the gap fills in with impurity states and low temperature heat capacity is enhanced.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Instability of the layered orthorhombic post-perovskite phase of SrTiO 3 and other candidate orthorhombic phases under pressure

Although the tetragonal antiferro-electrically distorted (AFD) phase with space group I4/mcm is well known for SrTiO 3 to occur below 105 K, there are also some hints in the literature of an orthorhombic phase, either at the lower temperature or at high pressure. A previously proposed orthorhombic layered structure of SrTiO 3 , known as the post-perovskite or CaIrO 3 structure with space group Cmcm is shown to have significantly higher energy than the cubic or tetragonal phase and to have its minimum volume at larger volume than cubic perovskite. The Cmcm structure is thus ruled out. We also study an alternative Pnma phase obtained by two octahedral rotations about different axes. This phase is discovered to have slightly lower energy than the I4/mcm phase in spite of the fact that its parent, in-phase tilted P4/mbm phase is not found to occur. Our calculated enthalpies of formation show that the I4/mcm phase occurs at slightly higher volume than the cubic phase and has a negative transition pressure relative to the cubic phase, which suggests that it does not correspond to the high-pressure tetragonal phase. The enthalpy of the Pnma phase is almost indistinguishable from the I4/mcm phase. Alternative ferro-electric tetragonal and orthorhombic structures previously suggested in literature are discussed.

36 MATERIALS SCIENCE↗

Potential candidate genomic biomarkers of drug induced vascular injury in the rat

Drug-induced vascular injury is frequently observed in rats but the relevance and translation to humans present a hurdle for drug development. Numerous structurally diverse pharmacologic agents have been shown to induce mesenteric arterial medial necrosis in rats, but no consistent biomarkers have been identified. To address this need, a novel strategy was developed in rats to identify genes associated with the development of drug-induced mesenteric arterial medial necrosis. Separate groups (n = 6/group) of male rats were given 28 different toxicants (30 different treatments) for 1 or 4 days with each toxicant given at 3 different doses (low, mid and high) plus corresponding vehicle (912 total rats). Mesentery was collected, frozen and endothelial and vascular smooth muscle cells were microdissected from each artery. RNA was isolated, amplified and Affymetrix GeneChip Registered-Sign analysis was performed on selectively enriched samples and a novel panel of genes representing those which showed a dose responsive pattern for all treatments in which mesenteric arterial medial necrosis was histologically observed, was developed and verified in individual endothelial cell- and vascular smooth muscle cell-enriched samples. Data were confirmed in samples containing mesentery using quantitative real-time RT-PCR (TaqMan Trade-Mark-Sign ) gene expression profiling. In addition, the performance of the panel was also confirmed using similarly collected samples obtained from a timecourse study in rats given a well established vascular toxicant (Fenoldopam). Although further validation is still required, a novel gene panel has been developed that represents a strategic opportunity that can potentially be used to help predict the occurrence of drug-induced mesenteric arterial medial necrosis in rats at an early stage in drug development. -- Highlights: Black-Right-Pointing-Pointer A gene panel was developed to help predict rat drug-induced mesenteric MAN. Black-Right-Pointing-Pointer A gene panel was identified following treatment of rats with 28 different toxicants. Black-Right-Pointing-Pointer There was a strong correlation of genes and histologic evidence of mesenteric MAN. Black-Right-Pointing-Pointer Many genes were also regulated prior to histologic evidence of arterial effects.

60 APPLIED LIFE SCIENCES↗