Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Building control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Next Generation Nuclear Plant Phenomena Identification and Ranking Tables (PIRTs) Volume 4: High-Temperature Materials PIRTs

The Phenomena Identification and Ranking Table (PIRT) technique was used to identify safety-relevant/safety-significant phenomena and assess the importance and related knowledge base of high-temperature structural materials issues for the Next Generation Nuclear Plant (NGNP), a very high temperature gas-cooled reactor (VHTR). The major aspects of materials degradation phenomena that may give rise to regulatory safety concern for the NGNP were evaluated for major structural components and the materials comprising them, including metallic and nonmetallic materials for control rods, other reactor internals, and primary circuit components; metallic alloys for very high-temperature service for heat exchangers and turbomachinery, metallic alloys for high-temperature service for the reactor pressure vessel (RPV), other pressure vessels and components in the primary and secondary circuits; and metallic alloys for secondary heat transfer circuits and the balance of plant. These materials phenomena were primarily evaluated with regard to their potential for contributing to fission product release at the site boundary under a variety of event scenarios covering normal operation, anticipated transients, and accidents. Of all the high-temperature metallic components, the one most likely to be heavily challenged in the NGNP will be the intermediate heat exchanger (IHX). Its thin, internal sections must be able to withstand the stresses associated with thermal loading and pressure drops between the primary and secondary loops under the environments and temperatures of interest. Several important materials-related phenomena related to the IHX were identified, including crack initiation and propagation; the lack of experience of primary boundary design methodology limitations for new IHX structures; and manufacturing phenomena for new designs. Specific issues were also identified for RPVs that will likely be too large for shop fabrication and transportation. Validated procedures for on-site welding, post-weld heat treatment (PWHT), and inspections will be required for the materials of construction. High-importance phenomena related to the RPV include crack initiation and subcritical crack growth; field fabrication process control; property control in heavy sections; and the maintenance of high emissivity of the RPV materials over their service lifetime to enable passive heat rejection from the reactor core. All identified phenomena related to the materials of construction for the IHX, RPV, and other components were evaluated and ranked for their potential impact on reactor safety.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Assessing the Impact of Cybersecurity Attacks on Energy Systems

This paper investigates the cyber resiliency of future power systems with high penetration of distributed energy resources using advanced distributed and (or) hierarchical control architectures. Specifically, we simulate cyberattacks on three prototypical use cases, and we identify attack scenarios that are the most damaging to the overall system performance. We show that these attacks can have a significant impact on grid operation. Results provide additional insights into the robustness of the system to the most common cyberattacks.

buildings↗

Real-Time Defect Correction in Large-Scale Polymer Additive Manufacturing via Thermal Imaging and Laser Profilometer

Defects can result in a failed part and are costly in terms of time and material. This cost is even greater in the context of large-scale additive manufacturing where the objects can be very large. As a result, a great deal of research has focused on defect identification and mitigation. To address defects during object construction, researchers at Oak Ridge National Laboratory’s Manufacturing Demonstration Facility investigated an in-situ control system comprised of two sensors: a thermal camera and laser profilometer. This control system adjusted material flow and build speed to mitigate three types of defects: low layer times, underfill, and overfill. Several test objects were constructed. The control system was found to adjust build parameters to handle low layer times of approximately 15 seconds and height deviations from -100% underfill (the absence of a layer) to 50% overfill. Within two layers, height deviations could be returned to within 10% of the expected layer height. Further, preliminary results suggest the system can compensate for uneven build surfaces.

Borish, Michael↗

A hardware-in-the-loop (HIL) testbed for cyber-physical energy systems in smart commercial buildings

In recent years, there has been a growing trend toward the development of smart buildings that rely on cyber-physical systems (CPS) to optimize occupant comfort, safety, and energy efficiency. To ensure the reliable and efficient operation of CPS with designed control strategies, it is important to evaluate their performance under various scenarios before deploying them in the real world. This is where a Hardware-in-the-loop (HIL) testbed designed for studying sensor and control-related studies in smart buildings can be highly valuable. With the growing threat of cyber-attacks and physical faults targeting smart buildings, it is essential to ensure the security of building operations. A HIL testbed can emulate cyber-attack and physical fault scenarios, allowing researchers to develop and test threat detection and mitigation algorithms. This enables researchers to identify potential issues and optimize the algorithms in a safe and controlled environment before they are deployed in real-world settings, reducing the risk of failures that can negatively impact occupant comfort, safety, and energy efficiency. Therefore, this paper developed a HIL testbed designed for cyber-physical energy systems (e.g. buildings automation system (BAS)) in smart commercial buildings. The HIL testbed is comprised of a real-time building and Heating, Ventilation, and Air-Conditioning (HVAC) emulator using Modelica-based dynamic models, a set of BAS controllers, and a BAS computer server. The data generation capability of the HIL testbed is demonstrated by tracking normal and faulty operating data in the BAS, as well as monitoring detailed network traffic in the local BAS network. Here, this study further demonstrates the HIL testbed’s capability by conducting case studies on real-time physical fault and cyber-attack experiments using a Department of Energy (DOE) prototype commercial building. It is anticipated that the fully functional HIL testbed will be utilized for a variety of sensor and control-related studies, including but not limited to testing, developing, validating of different HVAC control strategies, fault detection & diagnosis, energy monitoring and analysis, cyber security study, etc.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Streamlined Approach for Environmental Restoration (SAFER) Plan for Corrective Action Unit 114: Area 25 EMAD Facility Nevada National Security Site, Nevada

This Streamlined Approach for Environmental Restoration (SAFER) Plan addresses the actions needed to achieve closure for Corrective Action Unit (CAU) 114, Area 25 EMAD Facility, identified in the Federal Facility Agreement and Consent Order (FFACO). CAU 114 comprises the following corrective action sites (CASs) located in Area 25 of the Nevada National Security Site: • 25-41-03, EMAD Facility (Building 3900) • 25-99-23, Manned Control Car (MCC) and Engine Installation Vehicle (EIV) • 25-33-05, Building 3901, Engine Transport System Maintenance Building (Train Shed) This plan provides the methodology for field activities needed to gather the necessary information for closing CAU 114. There is sufficient information and process knowledge from historical documentation and investigations of similar sites regarding the expected nature and extent of potential contaminants to recommend closure of CAU 114 using the SAFER process. Additional information will be obtained by conducting a field investigation before selecting the appropriate corrective actions for CAU 114. It is anticipated that the results of the field investigation and implementation of corrective actions will support a defensible recommendation that no further corrective action is necessary. The purpose of the corrective action investigation will be to document and verify the adequacy of existing information; to affirm the decision for either clean closure, closure in place, or no further action; and to provide sufficient data to implement the corrective action. The actual corrective action selected will be based on characterization activities implemented under this SAFER Plan. If specific conditions or findings fall outside the bounds of the conceptual site model, such as an unanticipated release, the Nevada Division of Environmental Protection (NDEP) will be consulted to determine the path forward before proceeding. Upon completion of SAFER activities, a closure report (CR) will be prepared and submitted to NDEP for review and approval. The schedule for completion of the CR will be established in consultation with NDEP.

54 ENVIRONMENTAL SCIENCES↗

Real-time process monitoring for direct ink write additive manufacturing

Direct ink write (DIW) printing of reactive resins presents a unique challenge due to the time-dependent nature of the rheological and chemical properties of the ink. As a result, careful print optimization or process control is important to obtain consistent, high quality prints. The present invention uses a flow-through characterization cell for in situ chemical monitoring of a resin ink during DIW printing. Additionally, in-line extrusion force monitoring can be combined with off-line post inspection using machine vision. By combining in-line spectroscopy and force monitoring, it is possible to follow reaction kinetics (for example, curing of a reactive resin) and viscosity changes during printing, which can be used for a closed-loop process control. Additionally, the capability of machine vision to automatically identify and quantify print artifacts can be incorporated on the printing line to enable real-time, AI-assisted quality control of the printed products. Together, these techniques can form the building blocks of an optimized process control strategy when complex reactive ink must be used to produce printed hardware.

Cook, Adam W.↗

Sensitivity of occupant comfort models to humidity and their effect on cooling energy use

Residential building energy consumption in the United States has decreased steadily during the last several decades largely because of advances in building codes as well as voluntary efficiency and labeling programs, which have resulted in the reduction in building sensible loads. Building latent loads have not decreased by the same amount, and field and analytical research studies have concluded that high-efficiency, low-load homes often have elevated indoor humidity levels, possibly leading to occupant discomfort. There are discrepancies in the literature on occupant comfort as it relates to indoor humidity and recommended upper humidity limits. The choice of humidity limit could potentially change results and conclusions on the energy impacts of a new air conditioner or dehumidifier technology, changing ventilation rates, or an improved building envelope. In this study, we use building simulations to explore the impact of humidity control on cooling energy use in efficient residential buildings for different humidity limits. We look at limits based on humidity ratio (or dew point temperature), wet-bulb temperature, relative humidity, and constant slope lines based on the popular comfort models of both Fanger and Gagge. We quantify the additional energy use required to control humidity below these limits. We look at the sensitivity of the results to different temperature and humidity set points, occupant internal gains, moisture buffering levels, evaporator airflow rates, and dehumidifier energy factors. High-efficiency home predicted energy savings are more sensitive to the assumed humidity limit and cooling and dehumidification set points than the other parameters investigated in this paper.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Supervisory Control of Loads and Energy Storage in Next-Generation Zero Energy Buildings

A zero energy building (ZEB)—also known as a net zero energy or zero net energy building—is a building that exports as much renewable energy as the total energy it imports from other sources on an annual basis (DOE 2015). Large-scale and commercially viable ZEBs are now in the marketplace, and they are expected to become a larger share of the commercial building footprint as government and private sector policies continue to promote the development of buildings that produce more on-site energy than they use. However, the load profiles of ZEBs are currently perceived by electric utilities to be unfavorable and unpredictable. As shown in Figure ES-1, ZEB load profiles can have abrupt changes in magnitude, at times switching rapidly between exporting and importing electricity. This is a challenge for utilities, which are responsible for constantly balancing electricity supply and demand across the grid. Addressing these concerns will require new strategies and tools.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Demonstration of Blockchain-Based Energy Transactions between Laboratory Test Homes

Current electricity payment mechanisms and accessible value streams are inhibiting innovation in energy markets that stand to enhance grid security and resilience and enable increased integration of distributed energy resources (DER). In the era of near-instantaneous settlement times brought about by blockchain technology, the unidirectional (customer --> utility) monthly settlement of the incumbent infrastructure appears arcane. The lack of an effective market interface for DER results in fewer value streams for customers, underutilized assets for utilities, and reduced opportunities for vendors/manufacturers. A secure, real-time energy market enabled by blockchain technology presents a transformative opportunity to unlock innovations in DER and integrated controls. Blockchain technology provides a compelling pathway to energy market evolution, however there are several challenges to be addressed, including: simultaneous exchange of currency and energy commodities, ensuring customer privacy, incorporating transmission/distribution losses in energy trading contracts. To address the first of these - commodity tracking - we have established peer-to-peer energy transactions between two test homes at the National Renewable Energy Laboratory. Our research architecture demonstrates integration with high-fidelity metering for commodity tracking, and integration with NREL's foresee(TM) controls platform which orchestrates building loads and DER to execute the energy contract. The digital currency Dash, which supports enhanced privacy features and instant transactions, is employed for transaction settlement. BlockCypher's blockchain-agnostic web services are used to provide future flexibility in integrating various payment and contract options. In this paper we describe the technology, the research methodology employed, and present results on transaction execution speed and compliance with energy trading contracts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tritium deformation interactions in FCC austenitic steels

Hydrogen deformation interactions are known to control the environmental degradation effects (H and He embrittlement, stress corrosion cracking,...) associated with the presence of H and its isotopes in structural materials. Different types of interaction have been investigated: trapping on stress field and strain-induced defects, enhanced diffusion along dislocation networks, transport by moving dislocation. For several reasons, the quantification of these interactions is a major challenge in nuclear systems involving the presence of tritium: prevention of tritium-induced damage, tritium inventory, management of tritiated waste... This paper reports recent results on the quantitative characterization of tritium deformation interactions in fee materials. (authors)

36 MATERIALS SCIENCE↗

Manipulating molecular order in nematic liquid crystal capillary bridges via surfactant adsorption: guiding principles from dissipative particle dynamics simulations

The ability of liquid crystals (LCs) to change orientational order is used in applications, ranging from sensors to displays. The aim of this work is to computationally investigate how surfactant adsorption on cylindrical LC bridges can be used to control such orientational order. Building from classical fundamental lessons, understanding the ordering of mesogens along a preferred axis with the help of molecular modelling contributes to investigations of systems that could be a platform for LC-based sensing applications. The coarse-grained dissipative particle dynamics (DPD) simulation method is implemented here, because it allows us to quantify the effect of molecular features on the properties of meso-scopic systems containing LC bridges, an aqueous solvent, and surfactants at various concentrations. Three surfactant types are modelled with short, medium, and long tail lengths, respectively. All surfactants adsorb at the LC–water interface. It is found that the length of the surfactant hydrophobic tail determines the effectiveness by which the LC order is affected. Short tails are not as effective as long ones. Surfactants with long tails affect the LC order, but, in agreement with experiments, predominantly only within a short distance from the LC–water interface. For these surfactants, the surface density at the LC–water interface is an important knob that can be used to control the order of the LCs. As the effective LC–surfactant interactions change, so does the distribution of the surfactants at the interface. Consistent with theoretical expectations, the results presented here elucidate the effect of molecular features on the anchoring mechanism between surfactants and mesogens within cylindrical bridges dispersed in aqueous systems and could be helpful for designing novel surface-active compounds in the development of advanced sensing devices based on LCs.

74 ATOMIC AND MOLECULAR PHYSICS↗

Beamline Control and Instrumentation System using Industrial Interface Techniques

How should a beamline be designed, which satisfies the needs and requirements of scientists and is easy to build and operate? Today, most control and instrumentation systems for beamlines are based on scientific requirements. Scientific details of the beamline, e.g. vacuum and beam physics details; are usually extensively described. However, control system specifications are often reduced to few requirements, e.g. which beam-related device to use. Lots of these systems work perfectly from the physicist's point of view, but are hard to bring into service and operate and difficult to extend with additional equipment. To overcome this, the engineering company ENZ has developed components using industrial standard interfaces to guarantee high flexibility for equipment extension. Using special interface boards and galvanic isolation offers increased stability of motion control axes. This saves resources during commissioning and service. A control system was developed and installed at a Soft-X-ray beamline at ASP Melbourne. It is operated under EPICs on distributed embedded IOC's based on PC-hardware. Motion and vacuum systems, measurement devices, e.g. a Low-Current Monitor (LoCuM) for beam position monitoring, and parts of the equipment protection system were developed and most of them tested in cooperation with DELTA at the Technical University of Dortmund.

43 PARTICLE ACCELERATORS↗

Measuring Outdoor Air Intake Rates into Existing Building

Practical and accurate technologies are needed for continuously measuring and controlling outdoor air (OA) intake rates in commercial building heating, ventilating, and air conditioning (HVAC) systems. This project evaluated two new measurement approaches. Laboratory experiments determined that OA flow rates were measurable with errors generally less than 10 percent using electronic air velocity probes installed between OA intake louver blades or at the outlet face of louvers. High accuracy was maintained with OA flow rates as low as 15 percent of the maximum for the louvers. Thus, with this measurement approach HVAC systems do not need separate OA intakes for minimum OA supply. System calibration parameters are required for each unique combination of louver type and velocity sensor location but calibrations are not necessary for each system installation. The research also determined that the accuracy of measuring OA flow rates with velocity probes located in the duct downstream of the intake louver was not improved by installing honeycomb airflow straighteners upstream of the probes. Errors varied with type of upstream louver, were as high as 100 percent, and were often greater than 25 percent. In conclusion, use of electronic air velocity probes between the blades of OA intake louvers or at the outlet face of louvers is a highly promising means of accurately measuring rates of OA flow into HVAC systems. The use of electronic velocity probes downstream of airflow straighteners is less promising, at least with the relatively small OA HVAC inlet systems employed in this research.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advancing Replicable Solutions for High-Performance Homes in the Southeast - JMC - Patrick Square

The work presented in this report advances the goals of the U.S. Department of Energy Building America program by improving the energy peformance of affordable and market-rate housing. Southface Energy Institute (Southface), part of the U.S. Department of Energy Building America research team Partnership for Home Innovation, worked with owners and builders with various market constraints and ultimate goals for three projects in three climate zones (CZs): Savannah Gardens in Savannah, Georgia (CZ 2); JMC Patrick Square in Clemson, South Carolina (CZ 3); and LaFayette in LaFayette, Georgia (CZ 4). This report documents the design process, computational energy modeling, construction, envelope performance metrics, long-term monitoring results, and successes and failures of the design and execution of these highperformance homes. The JMC Patrick Square project is a single floor with 1,828 ft2 of conditioned living space, three bedrooms, two bathrooms, and an attached two-car garage. This small-scale production builder wanted to increase its level of energy efficiency beyond its current green building practices, including bringing ducts into conditioned space. The team met this goal through a combination of upgrade measures and achieved many Zero Energy Ready Home program requirements. Monitoring the four ducted HPWHs in LaFayette and one in Savannah revealed that HPWH exhaust air impacts attic air during HPWH runtime only, and attic conditions return to previous levels shortly after the HPWH turns off. The HPWH did not appear to impact the loads on the heating and cooling systems, which were also placed in the attic. HPWHs should not be considered dehumidifiers if one is needed in an attic or basement/crawlspace. Ducting the HPWHs did not negatively impact performance compared to other published data of field performance. Changing duct configurations also did not alter the coefficient of performance. HPWHs in efficiency mode (heat pump only) could satisfy hot water demand for most residents. This mode maximizes energy efficiency. Adding .5 in. of insulated sheathing using the Huber ZIP System R Sheathing reduced peak summer temperatures and increased minimum winter temperatures inside the wall assemblies compared to the neighboring home. The neighboring home experienced significantly more risk of condensation and failed the American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Standard 160-2009: Criteria for Moisture-Control Design Analysis in Buildings. Despite the fact that energy modeling predicted only a 2% annual savings from the insulated sheathing, preliminary data indicate that reduced heating, ventilating, and air-conditioning runtimes and energy consumption attributed to this measure provide significantly greater savings. Additional research is necessary.

Array↗

Design and analysis of embedded I and C for loop-scale magnetically suspended pump - 261

Improving nuclear reactor designs and fuel processing technologies for safer and more efficient operation require the development of new component designs. In particular, many of the advanced reactor design such as the molten salt reactors and high-temperature gas cooled reactors have operating environments beyond the ability of many currently commercially available components. To address this, new cross-cutting technologies need to be developed that will enable the design, fabrication, and reliable operation of new classes of reactor components. The Advanced Sensor Initiative of the Nuclear Energy Enabling Technologies initiative is investigating advanced sensor and control designs that are capable of operating in these extreme environments. Under this initiative Oak Ridge National Laboratory (ORNL) has been developing embedded instrumentation and control for extreme environments. To develop, test, and validate these new sensing and control techniques, ORNL is building a pump testbed with submerged magnetic bearings. The eventual goal is to apply these techniques to a high temperature (700 deg. C) canned rotor pump that utilizes active magnetic bearings to eliminate the need for mechanical bearings and seals. The technologies will benefit the Next Generation Power Plant, Advanced Reactor Concepts, and Small Modular Reactor programs. In this paper we will detail the design and analysis of the embedded I and C testbed with submerged magnetic bearings. Then we will analyze the fluid forces on the shaft. Finally, we will develop the radial and thrust bearing geometries needed to meet the force requirements. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Ecosystem-Level Biomimicry for the Built Environment: Adopting Systems Ecology Principles for the Control of Heterogeneous Energy Systems

This paper presents, to our knowledge, the first system-level engineering study to bio-mimic the cybernetics and flow dynamics of energy resources in natural ecosystems for the control of heterogeneous energy infrastructures in the built environment. To this end, we introduce a novel Biomimetic Pulsing State (BPS) control that functionally mimics mature ecosystems. A preliminary Modelica-based case study features a single-family residential building with electrical and HVAC subsystems. The BPS control objective is to minimize the energy exchange between the building and the grid for the purposes of future self-supporting buildings and grid stability. The building contains PV, a wind turbine, a battery storage system, and a fan coil/heat pump HVAC system served by an ambient district energy network. Evaluating the control performance (BPS vs. constant setpoint) over several renewable energy scenarios (net importer, net zero, net exporter), simulation results show how the building's HVAC system can dynamically adjust its electrical load and temperatures to the electrical system's net energy status in real-time with BPS control. As a net importer, the heat pump consumed 29% less energy and its peak power reduced by 15% with BPS control compared to the constant setpoint case, with the zone air temperature 1 degree C lower on average. As a net exporter, the heat pump effectively consumed the same energy, but the peak power increased by 34% with BPS control, while the zone air temperature was 1 degree C higher when renewable energy was abundant, preheating the home. BPS and constant setpoint control produced comparable results under a net zero scenario. While further evaluation is essential, BPS control may help communities meet their sustainability and resiliency targets as they transition towards fully distributed and renewable energy grids.

biomimicry↗

Energy efficiency outlook in China’s urban buildings sector through 2030

Here, this study uses bottom-up modeling framework in order to quantify potential energy savings and emission reduction impacts from the implementation of energy efficiency programs in the building sector in China. Policies considered include (1) accelerated building codes in residential and commercial buildings, (2) increased penetration of district heat metering and controls, (3) district heating efficiency improvement, (4) building energy efficiency labeling programs and (5) retrofits of existing commercial buildings. Among these programs, we found that the implementation of building codes provide by far the largest savings opportunity, leading to an overall 17% reduction in overall space heating and cooling demand relative to the baseline. Second are energy efficiency labels with 6%, followed by reductions of losses associated with district heating representing 4% reduction and finally, retrofits representing only about a 1% savings.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗