Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Building Efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Capability 9.1 Exploration

The exploration challenge are: To build an efficient, cost effective exploration infrastructure, To coordinate exploration robots & crews from multiple. earth sites to accomplish science and exploration objectives. and To maximize self-sufficiency of the lunar/planetary exploration team.

Eckelkamp, Rick↗

Downscaling NASA Climatological Data to Produce Detailed Climate Zone Maps

The design of energy efficient sustainable buildings is heavily dependent on accurate long-term and near real-time local weather data. To varying degrees the current meteorological networks over the globe have been used to provide these data albeit often from sites far removed from the desired location. The national need is for access to weather and solar resource data accurate enough to use to develop preliminary building designs within a short proposal time limit, usually within 60 days. The NASA Prediction Of Worldwide Energy Resource (POWER) project was established by NASA to provide industry friendly access to globally distributed solar and meteorological data. As a result, the POWER web site (power.larc.nasa.gov) now provides global information on many renewable energy parameters and several buildings-related items but at a relatively coarse resolution. This paper describes a method of downscaling NASA atmospheric assimilation model results to higher resolution and maps those parameters to produce building climate zone maps using estimates of temperature and precipitation. The distribution of climate zones for North America with an emphasis on the Pacific Northwest for just one year shows very good correspondence to the currently defined distribution. The method has the potential to provide a consistent procedure for deriving climate zone information on a global basis that can be assessed for variability and updated more regularly.

Chandler, William S.↗

NIRPS: A Year of Progress and Challenge

In the past 14 months NIRPS has gone from an idea on a sheet of paper to a working organization, performing tasks of national scale. NIRPS is beginning to establish itself among the Propulsion Community. Need is recognized for a coordination and integration function across the US Government s propulsion activities. NIRPS acts as a collaboration agent - serves as a catalyst and multi-agency facilitator NIRPS is leading a high-priority Government-wide task. 2012 Defense Authorization Act, Sec 1095; Develop National Rocket Propulsion Strategy. Beginning to perform in accordance with Grand Challenges. Performing to an Executable plan, adjusting to to Center and Agency priorities. Challenges remain to building a sustainable Institute. Effective integration and Coordination with other Government Agencies. Continued Active engagement with Industry and Academia. Building an Efficient and Responsive Governance System for a growing Institute.

Thomas, Dale↗

Buckling Response of a Large-Scale, Seamless, Orthogrid-Stiffened Metallic Cylinder

Results from the buckling test of a compression-loaded 8-ft-diameter seamless (i.e., without manufacturing joints), orthogrid-stiffened metallic cylinder are presented. This test was used to assess the buckling response and imperfection sensitivity characteristics of a seamless cylinder. In addition, the test article and test served as a technology demonstration to show the application of the flow forming manufacturing process to build more efficient buckling-critical structures by eliminating the welded joints that are traditionally used in the manufacturing of large metallic barrels. Pretest predictions of the cylinder buckling response were obtained using a finite-element model that included measured geometric imperfections. The buckling load predicted using this model was 697,000 lb, and the test article buckled at 743,000 lb (6% higher). After the test, the model was revised to account for measured variations in skin and stiffener geometry, nonuniform loading, and material properties. The revised model predicted a buckling load of 754,000 lb, which is within 1.5% of the tested buckling load. In addition, it was determined that the load carrying capability of the seamless cylinder is approximately 28% greater than a corresponding cylinder with welded joints.

Rudd, Michelle Tillotson↗

Swamp Works Technology Development 10th Anniversary: 2013-2023 - Innovative Research & Technology Development Summary

Kennedy Space Center’s (KSC) Swamp Works, provides government and commercial space ventures with the technologies required for working and living on the surfaces of the Moon or other planets and bodies in our solar system. The Swamp Works team establishes rapid, innovative and cost-effective exploration mission solutions through leveraging of partnerships across NASA, industry and academia. Concepts start small and build up efficiently, with lean development processes and a hands-on approach. Testing is performed in early stages to drive design improvements and progressively increase Technology Readiness Levels (TRL). Swamp Works provides concepts, architecture studies and trades, designs, data, technology development, technology demonstration hardware, flight hardware, testing, flight support and knowledge in support of the development of surface systems. It consists of several teams with associated laboratories and test capabilities. The Granular Mechanics and Regolith Operations (GMRO) Laboratory and the Electrostatics and Surface Physics Laboratory (ESPL) are co-located in the Engineering Development Lab (EDL) facility high bay. The Applied Chemistry Lab (ACL) is in an adjacent facility and other KSC labs are being influenced by the innovation methods pioneered at the Swamp Works. The Swamp Works was founded in January 2013 by a group of scientists and engineers at KSC with the over-arching vision of expanding humanity and civilization into the solar system by the use of space resources via advanced technology. Ultimately, this will create a solar system economy that will improve the human condition due to the abundance of energy and resources. This presentation will summarize the projects and technology development that have been performed by the Swamp Works to celebrate its 10th Anniversary of innovation success.

Swamp Works↗

Beetle Kill Wall at NREL

When it comes to designing an interior decorative feature for one of the most energy efficient office buildings in the world, very few would consider bringing in a beetle to do the job. But thats what happened at the U.S. Department of Energy's (DOE) Research Support Facility (RSF) located on the National Renewable Energy Laboratory (NREL) campus.In June, the RSF will become home to more than 800 workers from DOE and NREL and building visitors will be greeted with a soaring, two-story high wall entirely covered with wood harvested from the bark beetle infestation that has killed millions of pine trees in the Western U.S. But, the use of beetle kill wood is just one example of the resources being leveraged to make the RSF a model for sustainability and one more step toward NRELs goal to be a net zero energy campus.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Zero Energy With an Affordable Price Tag: Friends School of Portland

More than half of all operating school districts in the U.S. are in rural areas. These small schools operate at a different scale and have different needs than their city counterparts. In 2003-2004, 20% of public schools in the U.S. served fewer than 200 students(1). Although the Friends School of Portland - which was designed to achieve both zero energy performance and Passivhaus certification - is an independent school, it faced financial constraints similar to those faced by many other small schools throughout the country. The project was financed through a capital campaign and a mortgage that forced a hard cost cap on the project, so the project team had to be diligent about every dollar that was spent. In its first year of operation, the school site energy use intensity was just 12 kbtu/ft2, a bit more than the 9 kbtu/ft2 predicted.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Zero Energy Schools: Architects Take the Lead

Zero energy schools are possible and practical, and architects are leading the way. Imagine a school so inviting that students want to come to school. Now imagine this school housed in a beautiful, light-filled building that produces more energy on an annual basis than it uses. Finally, imagine that the district built this school on the same budget as a conventional school, using typical materials, equipment, and tradespeople. Sound too good to be true Discovery Elementary School in Arlington, Virginia, is living proof that zero energy (ZE) schools are feasible, affordable, and sensible.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Zero Energy Schools: The Challenges

School buildings have a lot of potential to achieve zero energy (ZE) in new construction as well as in retrofits. There are many examples of schools operating at ZE, and many technical resources available to guide school districts and their design and construction teams through the process. When school districts embark on the path to ZE, however, they often confront challenges related to processes and a perception that ZE buildings require 'new,' unconventional, and expensive technologies, materials, or equipment. Here are some of the challenges school districts and their design and construction teams commonly encounter, and the solutions they use to overcome them.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Commonwealth Edison (ComEd) Chicago Best Practices: Energy Data Accelerator

This case study describes how Commonwealth Edison (ComEd) and the city of Chicago worked together to develop a way for commercial building owners to get access to whole-building energy data more efficiently. This would enable building owners to comply with local energy benchmarking ordinances.

local government, utility, energy data, data acces↗

Eversource Best Practices: Energy Data Accelerator

The case study describes how Eversource and the cities of Boston and Cambridge, Massachusetts, worked together to develop a way for commercial building owners to get access to whole-building energy data more efficiently. This would enable building owners to comply with local energy benchmarking ordinances.

local government, utility, energy data, data acces↗

Is the Adoption of Electric Vehicles (EVs) and Solar Photovoltaics (PVs) Interdependent or Independent? An Integrated EVs-PVs Modeling Framework

Transportation and residential energy consumption account for more than one-half of the overall energy consumption in the United States. Adoption of electric vehicles (EVs) can play a key role in decarbonizing the transportation sector, while the adoption of renewable energy sources (e.g., solar photovoltaics or PVs) could bring similar benefits to the residential energy sector and in turn support transport electrification. Although the market share for both EVs and PVs continue to grow, both these emerging technologies are deployed rather disjoint without considering the existence of potential similarities among users who own (or aspire to own) EVs and PVs. This might be due to lack of understanding of the behavioral interdependence in consumer preferences towards these technologies. To fill this gap in knowledge, this study utilizes data from the 2018 WholeTraveler Transportation Behavior Study to develop an integrated model system that explores EV and PV adoption behaviors. A structural equations model (SEM) is employed that incorporates direct effects as well as error correlations among the adoption behaviors for EVs and PVs. Model results indicate that the adoption behavior for both these technologies is indeed interconnected and significantly influenced by attitudes, values and personality traits. Findings from this research suggest that incentives (e.g., subsidies) that drive 'bundled' adoption of EVs and PVs could accelerate the adoption of both these sustainable technologies. The results highlights the need to consider transport and building energy efficient technology adoption behavior in a single integrated structure.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

From Chills to Thrills: Revolutionizing Energy Efficiency and Load Flexibility in Supermarket Refrigeration

Open-vertical medium-temperature refrigerated display cases comprise nearly 50% of total case lineups in a typical supermarket, with more than 80% of their cooling load attributed to infiltration of warm and moist air from the surrounding space. The infiltration takes place across the air curtain system of the display case. While the air curtain acts as a thermal shield and as a cooling mechanism to maintain product temperature, it also entrains large amounts of heat and moisture from the adjacent space. Additionally, from food safety and quality standpoints, these fixtures are vulnerable to electric outages and traditionally cannot participate in load flexibility events. This paper describes key features of an innovative design of a self-contained, water-cooled, medium-temperature, open-vertical display case. The novel concept will eliminate the inefficient air curtain system and incorporate a hybrid radiant and low-airflow convective cooling design with a thermal-energy-storage-coupled heat exchanger integrated into the refrigeration circuit. The focus of this paper is on evaluating the thermal performance of the novel hybrid design in maintaining target product temperature. It presents thermal performance findings from thermo-fluid system modeling and robust state-of-the-art laboratory experiments used to validate those models. Load flexibility attributes from thermal energy storage are not discussed. A controlled-environment chamber at the National Renewable Energy Laboratory was leveraged to validate the thermal performance of the novel technology. Final results from bench-scale experiments indicate the proposed design maintained mean product temperatures within food safety guidelines.

commercial refrigeration↗

From Chills to Thrills: Revolutionizing Energy Efficiency and Load Flexibility in Supermarket Refrigeration: Preprint

Open-vertical medium-temperature refrigerated display cases comprise nearly 50% of total case lineups in a typical supermarket, with more than 80% of their cooling load attributed to infiltration of warm and moist air from the surrounding space. The infiltration takes place across the air curtain system of the display case. While the air curtain acts as a thermal shield and as a cooling mechanism to maintain product temperature, it also entrains large amounts of heat and moisture from the adjacent space. Additionally, from food safety and quality standpoints, these fixtures are vulnerable to electric outages and traditionally cannot participate in load flexibility events. This paper describes key features of an innovative design of a self-contained, water-cooled, medium-temperature, open-vertical display case. The novel concept will eliminate the inefficient air curtain system and incorporate a hybrid radiant and low-airflow convective cooling design with a thermal-energy-storage-coupled heat exchanger integrated into the refrigeration circuit. The focus of this paper is on evaluating the thermal performance of the novel hybrid design in maintaining target product temperature. It presents thermal performance findings from thermo-fluid system modeling and robust state-of-the-art laboratory experiments used to validate those models. Load flexibility attributes from thermal energy storage are not discussed. A controlled-environment chamber at the National Renewable Energy Laboratory was leveraged to validate the thermal performance of the novel technology. Final results from bench-scale experiments indicate the proposed design maintained mean product temperatures within food safety guidelines.

commercial refrigeration↗

Grid Interactive Micro-Distributed Refrigerated Display Case

Open-vertical medium-temperature refrigerated display cases comprise nearly 50% of total case lineups in a typical supermarket, with more than 80% of their cooling load attributed to infiltration of warm and moist air from the surrounding space. The infiltration takes place across the air curtain system of the display case. While the air curtain acts as a thermal shield and as a cooling mechanism to maintain product temperature, it also entrains large amounts of heat and moisture from the adjacent space. Additionally, from food safety and quality standpoints, these fixtures are vulnerable to electric outages and traditionally cannot participate in load flexibility events. This paper describes key features of an innovative design of a self-contained, water-cooled, medium-temperature, open-vertical display case. The novel concept will eliminate the inefficient air curtain system and incorporate a hybrid radiant and low-airflow convective cooling design with a thermal-energy-storage-coupled heat exchanger integrated into the refrigeration circuit. The focus of this paper is on evaluating the thermal performance of the novel hybrid design in maintaining target product temperature. It presents thermal performance findings from thermo-fluid system modeling and robust state-of-the-art laboratory experiments used to validate those models. Load flexibility attributes from thermal energy storage are not discussed. A controlled-environment chamber at the National Renewable Energy Laboratory was leveraged to validate the thermal performance of the novel technology. Final results from bench-scale experiments indicate the proposed design maintained mean product temperatures within food safety guidelines.

commercial refrigeration↗

American Recovery and Reinvestment Act (ARRA) FEMP Technical Assistance U.S. General Services Administration – Project 195 John Seiberling Federal Office Building and U.S. Courthouse, Akron, Ohio

This report documents the findings from an onsite audit of the John Seiberling Federal building located in Akron, Ohio. The Federal landlord for this building is the General Services Administration (GSA). The focus of the audit was to identify various no-cost or low-cost energy efficiency opportunities that, once implemented, would reduce in either electrical and gas consumption and increase the operational efficiency of the building. This audit also provided an opportunity to identify potential capital cost projects that should be considered in the to acquire additional energy (electric and gas) and water savings to further increase the operational efficiency of the building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Progress on Enabling an Interactive Conversation Between Commercial Building Occupants and Their Building To Improve Comfort and Energy Efficiency: Preprint

Many studies have reported energy savings after installing a dashboard, but dashboards provide neither individual feedback to the occupant nor the ability to report individual comfort. The Building Agent (BA) provides an interface to engage the occupant in a conversation with the building control system and the building engineer. Preliminary outcomes of the BA-enabled feedback loop are presented,and the effectiveness of the three display modes will be compared to other dashboard studies to baseline energy savings in future research.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

American Recovery and Reinvestment Act (ARRA) FEMP Technical Assistance US General Serices Administration - Project 193, John W. Bricker Federal Building, Columbus, OH

This report documents the findings from an onsite audit of the John W. Bricker Federal building located in Columbus, Ohio. The Federal landlord for this building is the General Services Administration (GSA). The focus of the audit was to identify various no-cost or low-cost energy efficiency opportunities that, once implemented, would either reduce electrical and gas consumption or increase the operational efficiency of the building. This audit also provided an opportunity to identify potential capital cost projects that should be considered in the future to acquire additional energy (electric and gas) and water savings to further increase the operational efficiency of the building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗