Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Base”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Comparison of Four Cisplatin-Based Radiochemotherapy Regimens for Nonmetastatic Stage III/IV Squamous Cell Carcinoma of the Head and Neck;Head-and-neck cancer; Cisplatin-based radiochemotherapy; Toxicity; Treatment outcomes

Purpose: To compare the outcomes of four cisplatin-based radiochemotherapy regimens in 311 patients with Stage III/IV squamous cell carcinoma of the head and neck. Methods and Materials: Concurrent chemotherapy consisted of three courses of cisplatin 100 mg/m{sup 2} on Day 1 (Group A, n = 74), two courses of cisplatin 20 mg/m{sup 2} on Days 1-5 plus 5-fluorouracil 1,000 mg/m{sup 2} on Days 1-5 (Group B, n = 49), two courses of cisplatin 20 mg/m{sup 2} on Days 1-5 plus 5-fluorouracil 600 mg/m{sup 2} on Days 1-5 (Group C, n = 102), or two courses of cisplatin 20 mg/m{sup 2} on Days 1-5 (Group D, n = 86). The groups were retrospectively compared for toxicity and outcomes, and 11 additional factors were evaluated for outcomes. Results: No significant difference was observed among the groups regarding radiation-related acute oral mucositis and radiation-related late toxicities. Acute Grade 3 skin toxicity was significantly more frequent in Group B than in the patients of the other three groups (p = .013). The chemotherapy-related Grade 3 nausea/vomiting rate was 24% for Group A, 8% for Group B, 9% for Group C, and 6% for Group D (p = .003). The corresponding Grade 3 nephrotoxicity rates were 8%, 1%, 2%, and 1% (p = .019). The corresponding Grade 3-4 hematologic toxicity rates were 35%, 41%, 19%, and 21% (p = .027). Chemotherapy could be completed in 50%, 59%, 74%, and 83% of the Group A, B, C, and D patients, respectively (p = .002). Toxicity-related radiotherapy breaks occurred in 39%, 43%, 21%, and 15% of Groups A, B, C, and D, respectively (p = .005). The 3-year locoregional control rate was 67%, 72%, 60%, and 59% for Groups A, B, C, and D, respectively (p = .48). The corresponding 3-year metastasis-free survival rates were 67%, 74%, 63%, and 79% (p = .31), and the corresponding 3-year survival rates were 60%, 63%, 50%, and 71% (p = .056). On multivariate analysis, Karnofsky performance status, histologic grade, T/N category, preradiotherapy hemoglobin level, completion of chemotherapy, and radiotherapy breaks were associated with the outcome. Conclusion: The four compared radiochemotherapy regimens were not significantly different regarding treatment outcomes. Two courses of cisplatin 20 mg/m{sup 2} on Days 1-5 were better tolerated than the other three regimens.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Heterogeneity-Based Dose Calculation Using a Deterministic Grid-Based Boltzmann Equation Solver for Intracavitary Brachytherapy

Purpose: To investigate the dosimetric impact of the heterogeneity dose calculation Acuros (Transpire Inc., Gig Harbor, WA), a grid-based Boltzmann equation solver (GBBS), for brachytherapy in a cohort of cervical cancer patients. Methods and Materials: The impact of heterogeneities was retrospectively assessed in treatment plans for 26 patients who had previously received {sup 192}Ir intracavitary brachytherapy for cervical cancer with computed tomography (CT)/magnetic resonance-compatible tandems and unshielded colpostats. The GBBS models sources, patient boundaries, applicators, and tissue heterogeneities. Multiple GBBS calculations were performed with and without solid model applicator, with and without overriding the patient contour to 1 g/cm{sup 3} muscle, and with and without overriding contrast materials to muscle or 2.25 g/cm{sup 3} bone. Impact of source and boundary modeling, applicator, tissue heterogeneities, and sensitivity of CT-to-material mapping of contrast were derived from the multiple calculations. American Association of Physicists in Medicine Task Group 43 (TG-43) guidelines and the GBBS were compared for the following clinical dosimetric parameters: Manchester points A and B, International Commission on Radiation Units and Measurements (ICRU) report 38 rectal and bladder points, three and nine o'clock, and {sub D2cm3} to the bladder, rectum, and sigmoid. Results: Points A and B, D{sub 2} cm{sup 3} bladder, ICRU bladder, and three and nine o'clock were within 5% of TG-43 for all GBBS calculations. The source and boundary and applicator account for most of the differences between the GBBS and TG-43 guidelines. The D{sub 2cm3} rectum (n = 3), D{sub 2cm3} sigmoid (n = 1), and ICRU rectum (n = 6) had differences of >5% from TG-43 for the worst case incorrect mapping of contrast to bone. Clinical dosimetric parameters were within 5% of TG-43 when rectal and balloon contrast were mapped to bone and radiopaque packing was not overridden. Conclusions: The GBBS has minimal impact on clinical parameters for this cohort of patients with unshielded applicators. The incorrect mapping of rectal and balloon contrast does not have a significant impact on clinical parameters. Rectal parameters may be sensitive to the mapping of radiopaque packing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accelerating Dynamic Magnetic Resonance Imaging (MRI) for Lung Tumor Tracking Based on Low-Rank Decomposition in the Spatial–Temporal Domain: A Feasibility Study Based on Simulation and Preliminary Prospective Undersampled MRI

Purpose: To evaluate a low-rank decomposition method to reconstruct down-sampled k-space data for the purpose of tumor tracking. Methods and Materials: Seven retrospective lung cancer patients were included in the simulation study. The fully-sampled k-space data were first generated from existing 2-dimensional dynamic MR images and then down-sampled by 5 × -20 × before reconstruction using a Cartesian undersampling mask. Two methods, a low-rank decomposition method using combined dynamic MR images (k-t SLR based on sparsity and low-rank penalties) and a total variation (TV) method using individual dynamic MR frames, were used to reconstruct images. The tumor trajectories were derived on the basis of autosegmentation of the resultant images. To further test its feasibility, k-t SLR was used to reconstruct prospective data of a healthy subject. An undersampled balanced steady-state free precession sequence with the same undersampling mask was used to acquire the imaging data. Results: In the simulation study, higher imaging fidelity and low noise levels were achieved with the k-t SLR compared with TV. At 10 × undersampling, the k-t SLR method resulted in an average normalized mean square error <0.05, as opposed to 0.23 by using the TV reconstruction on individual frames. Less than 6% showed tracking errors >1 mm with 10 × down-sampling using k-t SLR, as opposed to 17% using TV. In the prospective study, k-t SLR substantially reduced reconstruction artifacts and retained anatomic details. Conclusions: Magnetic resonance reconstruction using k-t SLR on highly undersampled dynamic MR imaging data results in high image quality useful for tumor tracking. The k-t SLR was superior to TV by better exploiting the intrinsic anatomic coherence of the same patient. The feasibility of k-t SLR was demonstrated by prospective imaging acquisition and reconstruction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Charge-and-energy conserving moment-based accelerator for a multi-species Vlasov–Fokker–Planck–Ampère system, part II: Collisional aspects

In this study, we extend the moment-based acceleration algorithm for the charge, momentum, and energy conserving Vlasov–Ampère discretization developed in Ref. [1] by including a reduced Fokker–Planck operator. We propose an energy conserving discretization for the Fokker–Planck collision operator. We show by numerical experiment that the new algorithm 1) efficiently converges the nonlinearly coupled Vlasov–Fokker–Planck–Ampère system, and 2) accurately steps over stiff time-scales such as the inverse electron plasma frequency, and the electron–electron collision time-scale. We demonstrate that discrete energy conservation is critical to eliminate numerical heating issues when strong density gradients exist.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Charge-and-energy conserving moment-based accelerator for a multi-species Vlasov–Fokker–Planck–Ampère system, part I: Collisionless aspects

In this study, we propose a charge, momentum, and energy conserving discretization for the 1D–1V Vlasov–Ampère system of equations on an Eulerian grid. The new conservative discretization is nonlinear in nature, but can be efficiently converged with a moment-based nonlinear accelerator algorithm. We demonstrate the conservation and convergence properties of the scheme with various numerical examples, including a multi-scale ion–acoustic shockwave problem.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A parallel domain decomposition-based implicit method for the Cahn–Hilliard–Cook phase-field equation in 3D

We present a numerical algorithm for simulating the spinodal decomposition described by the three dimensional Cahn–Hilliard–Cook (CHC) equation, which is a fourth-order stochastic partial differential equation with a noise term. The equation is discretized in space and time based on a fully implicit, cell-centered finite difference scheme, with an adaptive time-stepping strategy designed to accelerate the progress to equilibrium. At each time step, a parallel Newton–Krylov–Schwarz algorithm is used to solve the nonlinear system. We discuss various numerical and computational challenges associated with the method. The numerical scheme is validated by a comparison with an explicit scheme of high accuracy (and unreasonably high cost). We present steady state solutions of the CHC equation in two and three dimensions. The effect of the thermal fluctuation on the spinodal decomposition process is studied. We show that the existence of the thermal fluctuation accelerates the spinodal decomposition process and that the final steady morphology is sensitive to the stochastic noise. We also show the evolution of the energies and statistical moments. In terms of the parallel performance, it is found that the implicit domain decomposition approach scales well on supercomputers with a large number of processors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Plasma Simulation Code: A modern particle-in-cell code with patch-based load-balancing

This work describes the Plasma Simulation Code (psc), an explicit, electromagnetic particle-in-cell code with support for different order particle shape functions. We review the basic components of the particle-in-cell method as well as the computational architecture of the psc code that allows support for modular algorithms and data structure in the code. We then describe and analyze in detail a distinguishing feature of psc: patch-based load balancing using space-filling curves which is shown to lead to major efficiency gains over unbalanced methods and a previously used simpler balancing method.

Computer Science↗

Identifying factors controlling the selective ethane dehydrogenation on Pt-based catalysts from DFT based micro-kinetic modeling

Herein, a detailed EDH reaction mechanism on Pt(111), Pt(211), Pt 3 Sn(111) and Pt 3 Sn(211) surfaces has been systematically computed with DFT. A mean-field micro-kinetic model has been established to simulate the product distribution and selectivity on each surface at experimentally relevant conditions. We have uncovered a number of different factors controlling the catalytic performance of Pt-based EDH catalysts, thus leading to a better understanding of experimentally detected phenomenon. In this study, the (111) and (211) model surfaces of Pt and Pt 3 Sn catalysts were chosen to represent the terrace and step-edge sites when simulating the EDH reaction mechanisms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Understanding effects of chemical complexity on helium bubble formation in Ni-based concentrated solid solution alloys based on elemental segregation measurements

Here, helium bubble formation and swelling were systematically studied in Ni-based concentrated solid solution alloys containing different numbers and types of elements. Our microscopy analysis showed that although increasing the alloy chemical complexity helps suppress bubble formation in general, there is no monotonic relationship between the bubble growth rate and the number of alloying elements. Certain elements (e.g., Fe and Pd) are more effective in suppressing bubble growth than others (e.g., Cr and Mn). Atom probe tomography was applied to accurately measure elemental segregation around bubbles, revealing unique effects of certain alloying elements on vacancy migration towards bubbles. More specifically, the high vacancy mobility via Cr sites leads to a large vacancy flux and an increased bubble size, while the high degree of atomic size mismatch introduced by Pd helps deflect vacancy flow away from bubbles and decrease the amount of swelling. The effects identified in this study provide new strategies to design concentrated solid solutions with superior resistance to swelling.

36 MATERIALS SCIENCE↗

Achieving Highly Reproducible Results in Graphite-based Li-ion Full Coin Cells

Electrode materials, cathodes or anodes, are mostly evaluated in half coin cells where lithium (Li) metal is used. However, due to the instability nature of Li metal, the cycling performances of the half cells is more likely reflecting Li anode stability instead of the coupled electrodes, questioning the conclusions. Full coin cells utilizing graphite as the anode effectively assesses materials. But the key factors of preparing full coin cells with reproducible performances have rarely been discussed and overlooked leading to many inconsistent results. This work discusses the scientific gap between cell preparation and observed electrochemical performances to unveil the key parameters for achieving consistent and reliable results in full coin cells, critical for effective evaluation of any new materials tested under relevant conditions. The knowledge from this work is broadly applicable in other full cells systems such as Si-based full cells or Na-ion batteries.

Hu, Jiangtao↗

Electrochemical state and internal variables estimation using a reduced-order physics-based model of a lithium-ion cell and an extended Kalman filter

This paper addresses the problem of estimating the present value of electrochemical internal variables in a lithium-ion cell in real time, using readily available measurements of cell voltage, current, and temperature. The variables that can be estimated include any desired set of reaction flux and solid and electrolyte potentials and concentrations at any set of one-dimensional spatial locations, in addition to more standard quantities such as state of charge. The method uses an extended Kalman filter along with a one-dimensional physics-based reduced-order model of cell dynamics. Simulations show excellent and robust predictions having dependable error bounds for most internal variables. (C) 2014 Elsevier B.V. All rights reserved.

Stetzel, KD↗