Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BACKGROUND NOISE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

A Performance Comparison for Two Versions of the Vulcan Photometer

Analysis of the images produced by the first version (V1) of the Vulcan photometer indicated that two major sources of noise were sky brightness and image motion. To reduce the effect of the sky brightness, a second version (V2) with a longer focal length and a larger format detector was developed and tested. The first version consisted of 15-centimeter (cm) focal length, F/1.5 Aerojet Delft reconnaissance lens, and a 2048 x 2048 format front-illuminated charged coupled device (CCD) with 9 microns micropixels (Mpixels). The second version used a 30-cm focal length, F/2.5 Kodak AeroEktar lens, and a 4096 x 4096 format CCD with 9 micro pixels. Both have a 49-square-degree field of view (FOV) but the area of the sky subtended by each pixel in the V2 version is one-fourth that of the V1 version. This modification substantially reduces the shot noise due to the sky background and allows fainter stars to be monitored for planetary transits. To remove the data gap and consequent signal-level change caused by flipping the photometer around the declination axis and to reduce image movement on the detector, several other modifications were incorporated. These include modifying the mount and stiffening the photometer and autoguider structures to reduce flexure. This paper compares the performance characteristics of each photometer and discusses tests to identify sources of systematic noise.

Borucki, W. J.↗

Hires and beyond

The High-Resolution image construction program (HiRes) used at IPAC is based on the Maximum Correlation Method. After HiRes intensity images are constructed from IRAS data, additional images are needed to aid in scientific interpretation. Some of the images that are available for this purpose show the fitting noise, estimates of the achieved resolution, and detector track maps. Two methods have been developed for creating color maps without discarding any more spatial information than absolutely necessary: the 'cross-band simulation' and 'prior-knowledge' methods. These maps are demonstrated using the survey observations of a 2 x 2 degree field centered on M31. Prior knowledge may also be used to achieve super-resolution and to suppress ringing around bright point sources observed against background emission. Tools to suppress noise spikes and for accelerating convergence are also described.

Fowler, John W.↗

Diffraction, chopping, and background subtraction for LDR

The Large Deployable Reflector (LDR) will be an extremely sensitive infrared telescope if the noise due to the photons in the large thermal background is the only limiting factor. For observations with a 3 arcsec aperture in a broadband at 100 micrometers, a 20-meter LDR will emit 10(exp 12) per second, while the photon noise limited sensitivity in a deep survey observation will be 3,000 photons per second. Thus the background subtraction has to work at the 1 part per billion level. Very small amounts of scattered or diffracted energy can be significant if they are modulated by the chopper. The results are presented for 1-D and 2-D diffraction calculations for the lightweight, low-cost LDR concept that uses an active chopping quaternary to correct the wavefront errors introduced by the primary. Fourier transforms were used to evaluate the diffraction of 1 mm waves through this system. Unbalanced signals due to dust and thermal gradients were also studied.

Wright, Edward L.↗

Time-resolved measurements of the hot-electron population in ignition-scale experiments on the National Ignition Facility (invited)

In laser-driven inertial confinement fusion, hot electrons can preheat the fuel and prevent fusion-pellet compression to ignition conditions. Measuring the hot-electron population is key to designing an optimized ignition platform. The hot electrons in these high-intensity, laser-driven experiments, created via laser-plasma interactions, can be inferred from the bremsstrahlung generated by hot electrons interacting with the target. At the National Ignition Facility (NIF) [G. H. Miller, E. I. Moses, and C. R. Wuest, Opt. Eng. 43, 2841 (2004)], the filter-fluorescer x-ray (FFLEX) diagnostic–a multichannel, hard x-ray spectrometer operating in the 20–500 keV range–has been upgraded to provide fully time-resolved, absolute measurements of the bremsstrahlung spectrum with ∼300 ps resolution. Initial time-resolved data exhibited significant background and low signal-to-noise ratio, leading to a redesign of the FFLEX housing and enhanced shielding around the detector. The FFLEX x-ray sensitivity was characterized with an absolutely calibrated, energy-dispersive high-purity germanium detector using the high-energy x-ray source at NSTec Livermore Operations over a range of K-shell fluorescence energies up to 111 keV (U K{sub β}). The detectors impulse response function was measured in situ on NIF short-pulse (∼90 ps) experiments, and in off-line tests.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Feature Visibility Limits in the Non-Linear Enhancement of Turbid Images

The advancement of non-linear processing methods for generic automatic clarification of turbid imagery has led us from extensions of entirely passive multiscale Retinex processing to a new framework of active measurement and control of the enhancement process called the Visual Servo. In the process of testing this new non-linear computational scheme, we have identified that feature visibility limits in the post-enhancement image now simplify to a single signal-to-noise figure of merit: a feature is visible if the feature-background signal difference is greater than the RMS noise level. In other words, a signal-to-noise limit of approximately unity constitutes a lower limit on feature visibility.

Jobson, Daniel J.↗

Effects of center offset and noise on weak-lensing derived concentration-mass relation of dark matter halos

With the halo catalog from the Millennium Simulation, we analyze the weak-lensing measured density profiles for clusters of galaxies, paying attention to the determination of the concentration-mass (c-M) relation, which can be biased by the center offset, selection effect, and shape noise from intrinsic ellipticities of background galaxies. Several different methods of locating the center of a cluster from weak-lensing effects alone are explored. We find that, for intermediate redshift clusters, the highest peak from our newly proposed two-scale smoothing method applied to the reconstructed convergence field, first with a smoothing scale of 2' and then 0.'5, corresponds best to the true center. Assuming the parameterized Navarro-Frenk-White profile, we fit the reduced tangential shear signals around different centers identified by different methods. It is shown that, for the ensemble median values, a center offset larger than one scale radius r{sub s} can bias the derived mass and concentration significantly lower than the true values, especially for low-mass halos. However, the existence of noise can compensate for the offset effect and reduce the systematic bias, although the scatter of mass and concentration becomes considerably larger. Statistically, the bias effect of center offset on the c-M relation is insignificant if an appropriate center finding method is adopted. On the other hand, noise from intrinsic ellipticities can bias the c-M relation derived from a sample of weak-lensing analyzed clusters if a simple χ{sup 2} fitting method is used. To properly account for the scatter and covariance between c and M, we apply a Bayesian method to improve the statistical analysis of the c-M relation. It is shown that this new method allows us to derive the c-M relation with significantly reduced biases.

79 ASTRONOMY AND ASTROPHYSICS↗

A neural-network based estimator to search for primordial non-Gaussianity in Planck CMB maps

We present an upgraded combined estimator, based on Minkowski Functionals and Neural Networks, with excellent performance in detecting primordial non-Gaussianity in simulated maps that also contain a weighted mixture of Galactic contaminations, besides real pixel's noise from Planck cosmic microwave background radiation data. We rigorously test the efficiency of our estimator considering several plausible scenarios for residual non-Gaussianities in the foreground-cleaned Planck maps, with the intuition to optimize the training procedure of the Neural Network to discriminate between contaminations with primordial and secondary non-Gaussian signatures. We look for constraints of primordial local non-Gaussianity at large angular scales in the foreground-cleaned Planck maps. For the SMICA map we found f{sub NL} = 33 ± 23, at 1σ confidence level, in excellent agreement with the WMAP-9yr and Planck results. In addition, for the other three Planck maps we obtain similar constraints with values in the interval f{sub NL} element of [33, 41], concomitant with the fact that these maps manifest distinct features in reported analyses, like having different pixel's noise intensities.

79 ASTRONOMY AND ASTROPHYSICS↗

Algorithm Implementation for a Prototype Time-Encoded Signature Detector

The authors constructed a prototype Time-Encoded Signature (TES) system, complete with automated detection algorithms, useful for the detection of point-like, gamma-ray sources in search applications where detectors observe large variability in background count rates beyond statistical (Poisson) noise. The person-carried TES instrument consists of two Cesium Iodide scintillators placed on opposite sides of a Tungsten shield. This geometry mitigates systematic background variation, and induces a unique signature upon encountering point-like sources. This manuscript focuses on the development of detection algorithms that both identify point-source signatures and are computationally simple. The latter constraint derives from the instrument’s mobile (and thus low power) operation. The authors evaluated algorithms on both simulated and field data. The results of this analysis demonstrate the ability to detect sources at a wide range of source-detector distances using computationally simple algorithms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dedicated Searches for Low and High Mass Wimps with the SuperCDMS Soudan iZIP Detectors

Recent cosmological evidence suggests most of the mass of the universe takes the form of a type of particle that we have not been able to directly detect. Nearly 80 years that have elapsed since the rst hints of this dark matter started to appear from astronomers without any direct detection. The high precision era of cosmology and unifying models of particle physics developed in the 20 th century have presented us with an exciting mystery at the intersection of these two elds that needs to be solved. SuperCDMS Soudan operates specialized germanium detectors (iZIPs) that are cooled to milliKelvin temperatures deep underground in the Soudan Underground Laboratory with the hope of detecting a rare collision between dark matter and a nucleus. A search for low-mass dark matter comes with multiple unique challenges since the background discrimination abilities of these detectors becomes less powerful at the low energies needed to probe low-mass dark matter since the signal to noise ratio deteriorates. Using a sophisticated background model via a pulse rescaling technique, SuperCDMS Soudan was able to produce a world leading exclusion limit on low-mass dark matter. Effort is to extend the analysis to higher masses require long running times during which many aspects of the detectors or the environment can change. Additional challenges are offered by the powerful background discrimination ability of the iZIP. The background distributions are well separated from the signal region, meaning most of the leakage arises from low-probability tails of the background distributions. In the absence of an enormous dataset, extrapolations from the bulk of the distribution are required. While attempting to obtain a model of gamma induced electron-recoils leaking into the signal region of the detector from high radius a curious asymmetry between the sides of the detectors was discovered potentially indicating an electronics or detector design problem. This thesis describes the physics behind SuperCDMS Soudan, the numerous tasks involved in a low-mass search and the rst iZIP array science results with these new detectors, as well as the developments towards a high-mass search result.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Statistical ensemble analysis for simulating extrinsic noise-driven response in NF-κB signaling networks

Background: Gene expression profiles and protein dynamics in single cells have a large cell-to-cell variability due to intracellular noise. Intracellular fluctuations originate from two sources: intrinsic noise due to the probabilistic nature of biochemical reactions and extrinsic noise due to randomized interactions of the cell with other cellular systems or its environment. Presently, there is no systematic parameterization and modeling scheme to simulate cellular response at the single cell level in the presence of extrinsic noise. Results: In this paper, we propose a novel statistical ensemble method to simulate the distribution of heterogeneous cellular responses in single cells. We capture the effects of extrinsic noise by randomizing values of the model parameters. In this context, a statistical ensemble is a large number of system replicates, each with randomly sampled model parameters from biologically feasible intervals. We apply this statistical ensemble approach to the well-studied NF-κB signaling system. We predict several characteristic dynamic features of NF-κB response distributions; one of them is the dosage-dependent distribution of the first translocation time of NF-κB. Conclusion: The distributions of heterogeneous cellular responses that our statistical ensemble formulation generates reveal the effect of different cellular conditions, e.g., effects due to wild type versus mutant cells or between different dosages of external stimulants. Distributions generated in the presence of extrinsic noise yield valuable insight into underlying regulatory mechanisms, which are sometimes otherwise hidden.

59 BASIC BIOLOGICAL SCIENCES↗

The 21 cm signature of shock heated and diffuse cosmic string wakes

The analysis of the 21 cm signature of cosmic string wakes is extended in several ways. First we consider the constraints on Gμ from the absorption signal of shock heated wakes laid down much later than matter radiation equality. Secondly we analyze the signal of diffuse wake, that is those wakes in which there is a baryon overdensity but which have not shock heated. Finally we compare the size of these signals to the expected thermal noise per pixel which dominates over the background cosmic gas brightness temperature and find that the cosmic string signal will exceed the thermal noise of an individual pixel in the Square Kilometre Array for string tensions Gμ > 2.5 × 10{sup −8}.

79 ASTRONOMY AND ASTROPHYSICS↗

CONTAMINATION OF THE CENTRAL SUNYAEV-ZEL'DOVICH DECREMENTS IN AMiBA GALAXY CLUSTER OBSERVATIONS

We investigate the contamination of the Sunyaev-Zel'dovich (SZ) effect for six galaxy clusters, A1689, A1995, A2142, A2163, A2261, and A2390, observed by the Y. T. Lee Array for Microwave Background Anisotropy in 2007. With the range of baselines used, we find that the largest effect (of order 13%-50% of the central SZ flux density) comes from primary anisotropies in the cosmic microwave background and exceeds the thermal noise in all six cases. Contamination from discrete radio sources is estimated to be at a level of 3%-60% of the central SZ flux density. We use the statistics of these contaminating sources to estimate and correct the errors in the measured SZ effects of these clusters.

79 ASTRONOMY AND ASTROPHYSICS↗

Measuring galaxy cluster masses with CMB lensing using a Maximum Likelihood estimator: statistical and systematic error budgets for future experiments

We develop a Maximum Likelihood estimator (MLE) to measure the masses of galaxy clusters through the impact of gravitational lensing on the temperature and polarization anisotropies of the cosmic microwave background (CMB). We show that, at low noise levels in temperature, this optimal estimator outperforms the standard quadratic estimator by a factor of two. For polarization, we show that the Stokes Q/U maps can be used instead of the traditional E- and B-mode maps without losing information. We test and quantify the bias in the recovered lensing mass for a comprehensive list of potential systematic errors. Using realistic simulations, we examine the cluster mass uncertainties from CMB-cluster lensing as a function of an experiment’s beam size and noise level. We predict the cluster mass uncertainties will be 3 - 6% for SPT-3G, AdvACT, and Simons Array experiments with 10,000 clusters and less than 1% for the CMB-S4 experiment with a sample containing 100,000 clusters. The mass constraints from CMB polarization are very sensitive to the experimental beam size and map noise level: for a factor of three reduction in either the beam size or noise level, the lensing signal-to-noise improves by roughly a factor of two.

79 ASTRONOMY AND ASTROPHYSICS↗

Searching for Interstellar C{sub 60}{sup +} Using a New Method for High Signal-to-noise HST/STIS Spectroscopy

Due to recent advances in laboratory spectroscopy, the first optical detection of a very large molecule has been claimed in the diffuse interstellar medium (ISM): C{sub 60}{sup +} (ionized Buckminsterfullerene). Confirming the presence of this molecule would have significant implications regarding the carbon budget and chemical complexity of the ISM. Here we present results from a new method for ultra-high signal-to-noise ratio (S/N) spectroscopy of background stars in the near-infrared (at wavelengths of 0.9–1 μm), using the Hubble Space Telescope (HST) Imaging Spectrograph (STIS) in a previously untested “STIS scan” mode. The use of HST provides the crucial benefit of eliminating the need for error-prone telluric-correction methods in the part of the spectrum where the C{sub 60}{sup +} bands lie and where the terrestrial water vapor contamination is severe. Our STIS spectrum of the heavily reddened B0 supergiant star BD+63 1964 reaches an unprecedented S/N for this instrument (∼600–800), allowing the detection of the diffuse interstellar band (DIB) at 9577 Å attributed to C{sub 60}{sup +}, as well as new DIBs in the near-IR. Unfortunately, the presence of overlapping stellar lines, and the unexpected weakness of the C{sub 60}{sup +} bands in this sightline, prevents conclusive detection of the weaker C{sub 60}{sup +} bands. A probable correlation between the 9577 Å DIB strength and interstellar radiation field is identified, which suggests that more strongly irradiated interstellar sightlines will provide the optimal targets for future C{sub 60}{sup +} searches.

79 ASTRONOMY AND ASTROPHYSICS↗

Advanced Components for Spaceborne Infrared Astronomy

Basic improvements in the technology of low noise read-out systems for low background detectors were demonstrated. Using discrete JFET integrating amplifiers at their optimum temperature of 55 K, read noise less than 7.5 electrons in 128 seconds of integration was obtained. Two models of single channel integrators are now available, the JF-77 for use between 50 and 80 K and the JF-4 for lower temperatures. A 1 x 15 linear array of complete integrators on a single integrated circuit was developed and will be made available in the near future. The successful operation of a superconducting stepper motor was demonstrated. The motor shows a three fold increase in torque over conventional motors operating at room temperature. The success of the motor stems from the use of superconducting coils in conjunction with developments in bearings for cryogenic use, rare-earth rotors, and motor cooling techniques. The current state of development will allow the rapid development of motors optimized for specific applications. An electronic switch capable of resetting cooled JFET integrating amplifiers was developed. The JFET integrating amplifiers that use this switch have demonstrated read noise of less than 10 electrons. The JFET reset device exhibits an extremely high open impedance and low leakage current. Capacitance is sufficiently low so as not to impair amplifier sensitivity. The effects of transient switching charges are minimized by a compensation technique and variable transient current problems inherent to devices of this type are overcome by external circuity.

Davidson, Arnold W.↗

Curl up with a good B : detecting ultralight dark matter with differential magnetometry

Ultralight dark matter (such as kinetically mixed dark-photon dark matter or axionlike dark matter) can source an oscillating magnetic-field signal at the Earth’s surface, which can be measured by a synchronized array of ground-based magnetometers. The global signal of ultralight dark matter can be robustly predicted for low masses, when the wavelength of the dark matter is larger than the radius of the Earth, $λ_{DM}$ $\gg$ R. However, at higher masses, environmental effects, such as the Schumann resonances, can become relevant, making the global magnetic-field signal B difficult to reliably model. In this work, we show that ∇ × B is robust to global environmental details, and instead only depends on the local dark matter amplitude. We therefore propose to measure the local curl of the magnetic field at the Earth’s surface, as a means for detecting ultralight dark matter with $λ_{DM}$ ≲ R. As this measurement requires vertical gradients, it can be done near a hill/mountain. Our measurement scheme not only allows for a robust prediction, but also acts as a background rejection scheme for external noise sources. We show that our technique can be the most sensitive terrestrial probe of dark-photon dark matter for frequencies 10 Hz ≤ $f_{A'}$ ≤ 1 kHz (corresponding to masses 4 × 10 –14 eV ≤ $m_{A'}$ ≤ 4 × 10 –12 eV). It can also achieve sensitivities to axionlike dark matter comparable to the CAST helioscope, in the same frequency range.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Parameters of Photo-Sensitive Structures Based on Ge/Si Nanogeterostructures

Infrared photodetectors with germanium quantum dots on silicon are considered. Some characteristics of such detectors are calculated, namely: dark current and detectivity in the modes of limitation by background and generation-recombination noises. A comparison is also made of the performance of quantum-dot infrared detectors with the performance of HgCdTe detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗