Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ambient Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Feedback-Controlled LED Photobioreactor for Photophysiological Studies of Cyanobacteria

A custom photobioreactor (PBR) was designed to enable automatic light adjustments using computerized feedback control. A black anodized aluminum enclosure, constructed to surround the borosilicate reactor vessel, prevents the transmission of ambient light and serves as a mount for arrays of light-emitting diodes (LEDs). The high-output LEDs provide narrow-band light of either 630 or 680 nm for preferential excitation of the cyanobacterial light-harvesting pigments, phycobilin or chlorophyll a, respectively. Custom developed software BioLume provides automatic control of optical properties and a computer feedback loop can automatically adjust the incident irradiance as necessary to maintain a fixed transmitted light through the culture, based on user-determined set points. This feedback control serves to compensate for culture dynamics which have optical effects, (e.g., changing cell density, pigment adaptations) and thus can determine the appropriate light conditions for physiological comparisons or to cultivate light-sensitive strains, without prior analyses. The LED PBR may also be controlled as a turbidostat, using a feedback loop to continuously adjust the rate of media-dilution based on the transmitted light measurements, with a fast and precise response. This cultivation system gains further merit as a high-performance analytical device, using non-invasive tools (e.g., dissolved gas sensors, online mass spectrometry) to automate real-time measurements, thus permitting unsupervised experiments to search for optimal growth conditions, to monitor physiological responses to perturbations, as well as to quantitate photophysiological parameters using an in situ light-saturation response routine.

controlled cultivation↗

Camera selection for real-time in vivo radiation treatment verification systems using Cherenkov imaging

Purpose: To identify achievable camera performance and hardware needs in a clinical Cherenkov imaging system for real-time, in vivo monitoring of the surface beam profile on patients, as novel visual information, documentation, and possible treatment verification for clinicians. Methods: Complementary metal-oxide-semiconductor (CMOS), charge-coupled device (CCD), intensified charge-coupled device (ICCD), and electron multiplying-intensified charge coupled device (EM-ICCD) cameras were investigated to determine Cherenkov imaging performance in a clinical radiotherapy setting, with one emphasis on the maximum supportable frame rate. Where possible, the image intensifier was synchronized using a pulse signal from the Linac in order to image with room lighting conditions comparable to patient treatment scenarios. A solid water phantom irradiated with a 6 MV photon beam was imaged by the cameras to evaluate the maximum frame rate for adequate Cherenkov detection. Adequate detection was defined as an average electron count in the background-subtracted Cherenkov image region of interest in excess of 0.5% (327 counts) of the 16-bit maximum electron count value. Additionally, an ICCD and an EM-ICCD were each used clinically to image two patients undergoing whole-breast radiotherapy to compare clinical advantages and limitations of each system. Results: Intensifier-coupled cameras were required for imaging Cherenkov emission on the phantom surface with ambient room lighting; standalone CMOS and CCD cameras were not viable. The EM-ICCD was able to collect images from a single Linac pulse delivering less than 0.05 cGy of dose at 30 frames/s (fps) and pixel resolution of 512 × 512, compared to an ICCD which was limited to 4.7 fps at 1024 × 1024 resolution. An intensifier with higher quantum efficiency at the entrance photocathode in the red wavelengths [30% quantum efficiency (QE) vs previous 19%] promises at least 8.6 fps at a resolution of 1024 × 1024 and lower monetary cost than the EM-ICCD. Conclusions: The ICCD with an intensifier better optimized for red wavelengths was found to provide the best potential for real-time display (at least 8.6 fps) of radiation dose on the skin during treatment at a resolution of 1024 × 1024.

60 APPLIED LIFE SCIENCES↗

Triton Field Trials (TFiT) underwater noise - University of New Hampshire Living Bridge turbine Processed Data

In July 2021, a commercial-off-the-shelf hydrophone was deployed in a free-drifting configuration to measure underwater acoustic emissions and characterize a 25 kW-rated tidal turbine at the University of New Hampshire's Living Bridge Project in Portsmouth, New Hampshire. Sampling methods and analysis were performed in alignment with the recently published IEC 62600-40 Technical Specification for acoustic characterization of marine energy converters. Results from this study indicate acoustic emissions from the turbine were below ambient sound levels and therefore did not have a significant impact on the underwater noise levels of the project site. As a component of Pacific Northwest National Laboratory's Triton Field Trials (TFiT) described in a paper published in a Special Issue of Journal of Marine Energy Science and Engineering, this study provides a valuable use case for the IEC 62600-40 Technical Specification framework and further recommendations for cost-effective technologies and methods for measuring underwater noise at future current energy converter project sites. The paper can be accessed in the link bellow.

16 TIDAL AND WAVE POWER↗

Measuring Radioactivity from Fukushima Daiichi in New Mexico

On March 11, 2011, the Fukushima Daiichi nuclear power plant was damaged by the tsunami that followed the 'Great East Japan Earthquake,' and the reactor subsequently leaked radioactive material. In response, LANL augmented the routine ambient (AIRNET) and stack (Rad-NESHAP) measurements with three high-volume samplers: No.167 at the Old White Rock Fire Station; No.173 at the TA-49 gate, and No.211 at the Los Alamos Medical Center. Previous accidents, such as the Three-Mile-Island accident in 1979 and the Chernobyl accident in 1986, indicated that the most likely releases were (a) the noble gases: krypton and xenon; and (b) the volatile elements: cesium, tellurium, and iodine. At the latitude of Fukushima, the predominant winds across the Pacific Ocean are from west to east, and models predicted that the plume would arrive in the western US on about March 18. By this time the shorter-lived isotopes would have decayed. Therefore, the expected radionuclides were xenon-133, cesium-134, cesium-136, cesium-137, tellurium-132, iodine-131, and iodine-132. As expected, cesium-134, cesium-136, cesium-137, tellurium-132, iodine-131, and iodine-132 were all detected by all three high-volume samplers during March 17-21. The concentrations peaked during the March 24-28 period. After this, concentrations of all nuclides declined. In general, the concentrations were consistent with those measured by the EPA RadNet system and many other monitoring systems throughout the world. At the time of writing, preliminary results from the AIRNET and Rad-NESHAP systems are being reported. More detailed results are described in LA-UR-11-10304 and will be reported in full in the annual environmental report for 2011. All previous releases from nuclear reactors have been dominated by noble gases, primarily krypton and xenon, which are not measured by the high-volume samplers or the AIRNET system. However, in sufficient concentrations these and other fission products would be detected by NEWNET. Consistent with this possibility, all NEWNET detectors recorded an increase of 0.2 {micro}R/h from March 19-1, followed by an additional increase of 0.1 {micro}R/h on March 24 (Figure 1). The consistency of the NEWNET stations is indicated by the error bars, which represent the standard error of the mean of the individual stations. Over the next 10 days, the NEWNET readings declined with approximately the 5-day half life of xenon-133, returning to near normal levels on April 2. After this, any further decrease was masked by high radon concentrations on April 3, by a weather system that moved into New Mexico on April 4, and by rainfall on April 6-9. Furthermore, it is likely that all NEWNET detectors responded to a gradually increasing trend in terrestrial radiation during the month of March as the ground dried out. It is difficult to distinguish the hypothetical effects of xenon-133 from the fluctuations of radon decay products. However, at present we do not have an alternative hypothesis for the sharp increase that was observed in all NEWNET stations from March 19-21. Perhaps some of the increase was caused by radon or terrestrial radiation, in which case the observed increase is an upper limit to that caused by releases from Fukushima. LANL data are consistent with those of the EPA RadNet monitoring system. The EPA has repeatedly stated that 'The levels detected are far below levels of concern.'

CESIUM 134↗

Stress tolerance of a subtropical Crassostrea virginica population to the combined effects of temperature and salinity

The combination of salinity and temperature has synergistic effects on virtually all aspects of the biology of estuarine organisms. Of interest were site-specific characteristics in the response of the eastern oyster, Crassostrea virginica, from the St. Lucie River Estuary to the interactive effects of temperature and salinity. This estuary, one of the largest on the central east coast of Florida, is strongly influenced by anthropogenic modifications due to management needs to control the patterns of freshwater flow in the St. Lucie River watershed. C. virginica is designated a valued ecosystem component for monitoring the health of this estuary. Our approach used a multidimensional response surface design to study the effects of temperature and salinity on sublethal measures of oyster performance: (1) body condition index as an overall indicator of bioenergetic status and (2) the RNA/DNA ratio as a biochemical indicator of cellular stress. The results showed that there was a greater ability to withstand extreme salinity conditions at lower temperatures. However, there were no site-specific attributes that differentiated the response of the St. Lucie Estuary population from populations along the distribution range. Condition index was a less variable response than the RNA/DNA ratio, and the final models for mean condition index and the RNA:DNA ratios explained 77.3% and 35.8% of the respective variances.

59 BASIC BIOLOGICAL SCIENCES↗

Characterizing ISS Charging Environments with On-Board Ionospheric Plasma Measurements

Charging of the International Space Station (ISS) is dominated by interactions of the biased United States (US) 160 volt solar arrays with the relatively high density, low temperature plasma environment in low Earth orbit. Conducting surfaces on the vehicle structure charge negative relative to the ambient plasma environment because ISS structure is grounded to the negative end of the US solar arrays. Transient charging peaks reaching potentials of some tens of volts negative controlled by photovoltaic array current collection typically occur at orbital sunrise and sunset as well as near orbital noon. In addition, surface potentials across the vehicle structure vary due to an induced v x B (dot) L voltage generated by the high speed motion of the conducting structure across the Earth's magnetic field. Induced voltages in low Earth orbit are typically only approx.0.4 volts/meter but the approx.100 meter scale dimensions of the ISS yield maximum induced potential variations ofapprox.40 volts across the vehicle. Induced voltages are variable due to the orientation of the vehicle structure and orbital velocity vector with respect to the orientation of the Earth's magnetic field along the ISS orbit. In order to address the need to better understand the ISS spacecraft potential and plasma environments, NASA funded development and construction of the Floating Potential Measurement Unit (FPMU) which was deployed on an ISS starboard truss arm in August 2006. The suite of FPMU instruments includes two Langmuir probes, a plasma impedance probe, and a potential probe for use in in-situ monitoring of electron temperatures and densities and the vehicle potential relative to the plasma environment. This presentation will describe the use of the FPMU to better characterize interactions of the ISS with the space environment, changes in ISS charging as the vehicle configuration is modified during ISS construction, and contributions of FPMU vehicle potential and plasma environment measurements to investigations of on-orbit anomalies in ISS systems.

Minow, Jospeh I.↗

Fabrication and Deployment Testing of Solar Sail Quadrants for a 20-Meter Solar Sail Ground Test System Demonstration

A 20-meter Scalable Square Solar Sail (S(sup 4)) System was produced and successfully completed functional vacuum testing in NASA Glenn's Space Power Facility at Plum Brook Station Ohio in May 2005. The S(sup 4) system was designed and developed by ATK Space Systems, and the design and production of the Solar Sails for this system was carried out by SRS Technologies. The S(sup 4) system consists of a central structure with four deployable carbon fiber masts that support four triangular sails. SRS has developed an effective and efficient design for triangular sail quadrants that are supported at three points and provide a flat reflective surface with a high fill factor. This sail design is robust enough for deployments in a one atmosphere, one gravity environment and incorporates several advanced features including adhesiveless seaming of membrane strips, compliant edge borders to allow for film membrane cord strain mismatch without causing wrinkling and low mass (3% of total sail mass) ripstop. This paper will outline some of the sail design and fabrication processes and the mature production, packaging and deployment processes that have been developed. This paper will also detail the successful ambient and vacuum testing of the sails and the ATK spacecraft structure. Based on recent experience and testing, SRS is confidant that high Technology Readiness Level (TRL) 5-6 solar sails in the 40-120-meter size range with areal density in the 4-5 grams per square meters (sail minus structure) range can be produced with existing technology. Additional film production research will lead to further reductions in film thickness to less than 1 micron enabling production of sails with areal densities as low as 2.0 grams per square meters using the current design, resulting in a system areal densities as low as 5.3 grams per square meters (sail and structure). These areal densities are low enough to allow nearly all of the Solar Sail missions that have been proposed by the scientific community. The fundamental technologies required to produce these systems has been demonstrated on the 20-meter S(sup 4) sails that have recently completed ground testing demonstrating a mature and technology suitable for incorporation into future flight validation and future mission. Solar Sails can support NASA's Vision for Space Exploration by allowing communication satellite orbits that can maintain continuous communication with the polar regions of the Moon and Mars and to support solar weather monitoring to provide early warning of solar flares and storms that could threaten the safety of astronauts and other spacecraft.

Laue, Greg↗

Using In-Situ Deposition of Metallic Thin Films on Mars to Monitor Atmospheric H20

We describe the use of a novel sensor, designed to characterize the reactive nature of the Martian atmosphere, to also characterize the instantaneous abundance of atmospheric H,O. The sensor deposits, in situ, a thin silver film onto a sapphire substrate and monitors oxidation by measuring resistance of the Ag film during both deposition and subsequent oxidation [1,2]. . The evaporation source is placed in the center of a hollow, open-ended tube. On flash heating the source, evaporated metallic silver rapidly reacts with oxidizing gases in the tube, depositing on the tube walls as a resisitive Ag oxide film. Unoxidized silver deposits over the Ag oxides, once the oxidizing gases in the vicinity of the source have been consumed. Since the ends of the tube are open, atmospheric gases in the tube cause a time delay as the evaporated silver initially reacts with the available O2, and H2O; once oxidizing gases in the tube are significantly depleted, a silver film closes the chemiresistor circuit. In principle this operation mode provides a repeatable measure of the variable H2O abundance, since O2, levels are constant in the atmosphere. To explore the utility of the instrument as an H2O sensor, predict its behavior, and identify possible failure modes, we developed a numerical model of the instrument, and exercised it for Mars conditions. The model predicts the behavior of the electrical circuit, the temperature dependence of resistivity for each component, and the resultant Joule heating. The model balances Joule heating against radiation, sensible heat loss to ambient CO2, and, latent heat loss from sublimating Ag. The flux of Ag atoms from the source is tracked continuously. In the gas phase, the number density of Ag, O2, and H2O is calculated, along with their reaction rates on collision. The model suggests that Ag substantially depletes H2O only near the center of the tube. The model supports the hypothesis that the onset of high conductivity between the A u electrodes is a function of the H2O abundance in the ambient gas, but only to a limit; when H2O abundances are buffered at or above 240K (an H2O abundance that would not have occurred on Mars), metallic Ag never deposits in excess of Ago, and the circuit does not close. A significant difference in the Mars simulation is that the Ag source sublimates more quickly, primarily because of differences in sensible heat fluxes from the source. This allows subsequent heating of the W filament used to support the Ag source. Had the originally-designed experimental sequence been carried out on Mars, the filament might have melted, making subsequent investigations impossible.

Zent, A. P.↗

Commercial-Off-The-Shelf Microelectromechanical Systems (MEMS) Flow-Measurement Probes Fabricated And Assembled

As an alternative to conventional tubing instrumentation for measuring airflow, designers and technicians at the NASA Glenn Research Center have been fabricating packaging components and assembling a set of unique probes using commercial-off-the-shelf microelectromechanical systems (MEMS) integrated circuits (computer chips). Using MEMS as an alternative has some compelling advantages over standard measurement devices. Sensor technologies have matured through high-production usage in industries such as automotive and aircraft manufacturers. Currently, MEMS are the choice in applications such as tire pressure monitors, altimeters, pneumatic controls, cable leak detectors, and consumer appliances. Conventional instrumentation uses tubing buried in the model aerodynamic surfaces or wind tunnel walls. The measurements are made when pressure is introduced at the tube opening. The pressure then must travel the tubing for lengths ranging from 20 to hundreds of feet before reaching an electronic signal conditioner. This condition causes a considerable amount of damping and requires measurements to be made only after the test rig has reached steady-state operation. The electronic MEMS pressure sensor is able to take readings continuously under dynamic states in nearly real time. The use of stainless steel tubing for pressure measurements requires many tubes to be cleaned, cut to length, carefully installed, and delicately deburred and spliced for use. A cluster of a few hundred 1/16-in.- (0.0625-in.-) diameter tubes (not uncommon in research testing facilities) can be several inches in diameter and may weigh enough to require two men to handle. Replacing hard tubing with electronic chips can eliminate much of the bulk. Each sensor would fit on the tip of the 1/16-in. tubing with room to spare. The P592 piezoresistive silicon pressure sensor (Lucas NovaSensor, Fremont, CA) was chosen for this project because of its cost, availability, and tolerance to extreme ambient conditions. The chip is 1 mm square by 0.6 mm thick (0.039 by 0.023 in.) with 0.12-mm (0.005-in.) wire connection tabs. Three MEMS chips were used to build the first type of flow-angularity probe. This MEMS probe will be demonstrated as an alternative to a standard tube type "Cobra Probe" now used routinely in wind tunnel and aeronautical hardware applications. The response time and accuracy would allow the probe to be translated on an actuator across a flow field, yielding precision dynamic measurements not possible with conventional instrumentation. The low profile, the minimal power requirement, the rugged construction, and the moderate cost all contribute to making MEMS sensors the enticing choice instrument in future research measurement needs. The MEMS probe efforts are a continuation of work initiated by Brian Willis, without whose foresight and efforts this project would never have been realized. This task was funded through cooperation with the NASA Electronic Parts and Packaging (NEPP) program at the Jet Propulsion Laboratory.

Redding, Chip↗

Aerosol hygroscopic growth, contributing factors, and impact on haze events in a severely polluted region in northern China

This study investigates the impact of the aerosol hygroscopic growth effect on haze events in Xingtai, a heavily polluted city in the central part of the North China Plain (NCP), using a large array of instruments measuring aerosol optical, physical, and chemical properties. Key instruments used and measurements made include the Raman lidar for atmospheric water vapor content and aerosol optical profiles, the PC-3016A GrayWolf six-channel handheld particle and mass meter for atmospheric total particulate matter (PM) that has diameters less than 1 and 2.5 µ m (PM 1 and PM 2.5 , respectively), the aerosol chemical speciation monitor (ACSM) for chemical components in PM 1 , and the hygroscopic tandem differential mobility analyzer (H-TDMA) for aerosol hygroscopicity. The changes in PM 1 and PM 2.5 agreed well with that of the water vapor content due to the aerosol hygroscopic growth effect. Two cases were selected to further analyze the effects of aerosol hygroscopic growth on haze events. The lidar-estimated hygroscopic enhancement factor for the aerosol backscattering coefficient during a relatively clean period (Case I) was lower than that during a pollution event (Case II) with similar relative humidity (RH) levels of 80 %–91 %. The Kasten model was used to fit the aerosol optical hygroscopic growth factor (GF) whose parameter b differed considerably between the two cases, i.e., 0.1000 (Case I) versus 0.9346 (Case II). The aerosol acidity value calculated from ACSM data for Case I (1.35) was less than that for Case II (1.50) due to different amounts of inorganics such as NH 4 NO 3 , NH 4 HSO 4 , and (NH 4 ) 2 SO 4 . Model results based on H-TDMA data showed that aerosol hygroscopic growth factors in each size category (40, 80, 110, 150, and 200 nm) at different RH levels (80 %–91 %) for Case I were lower than those for Case II. For similar ambient RH levels, the high content of nitrate facilitates the hygroscopic growth of aerosols, which may be a major factor contributing to heavy haze episodes in Xingtai.

Chen, Jun↗

Ice nucleation measurements from DRUM impactors during TRACER campaign in the Houston TX region from July to September 2022

During TRACER, three Davis Rotating Uniform size-cut Monitors (DRUM; DRUMAir 4-DRUM) were used to collect aerosols for ice nucleation measurements in the Brooks laboratory at Texas A&M University. The three instruments were located at AMF1 in La Porte, Ancillary site in Guy (ANC), and onboard the Texas A&M Rapid Onsite Atmospheric Measurements Van (ROAM-V). ROAM-V was deployed to capture airmasses behind (maritime) and ahead (continental) of the passage of the sea-breeze front through Houston. On select sampling days, ROAM-V sampled in the morning/mid-day on the coast and then transited to a second inland site for the afternoon/evening. The suite of instruments deployed on ROAM-V included a Condensation Particle Counter (CPC; GRIMM Model 5.403 CPC), Scanning Mobility Particle Sizer (SMPS; TSI 3750 detector, TSI 3082 classifier, TSI 3088 neutralizer, TSI 3081A Differential Mobility Analyzer), Cloud Condensation Nuclei counter (Droplet Measurement Technologies CCN Counter), micro pulse lidar (Droplet Measurement Technologies Micro Pulse LiDAR (miniMPL)), and one of the Davis Rotating Uniform size-cut Monitors (DRUM; DRUMAir 4-DRUM). Before sampling at each location, the latitude and longitude were recorded using the GPS on the phone application “My Altitude”. Each DRUM sampler was operated at a flow rate of 23 LPM. Each DRUM has four stages where the aerodynamic diameter size cuts are as follows: stage 1 larger than 3 μm, stage 2 from 3 to 1.2 μm, stage 3 from 1.2 to 0.34 μm, and stage 4 from 0.34 to 0.15 μm. Pretreated aluminum foil was used as a substrate on all stages. At AMF1 and ANC sites, the DRUMs were operated on the shared aerosol inlet, with generous support of the DOE ARM site staff. These instruments rotated 24 mm per day and only contained aluminum foil substrates. Substrates were changed weekly and transported to Texas A&M for storage in -80C freezer until analysis. The DRUM onboard ROAM-V was operated at a faster rotation rate of 150 mm per day to clearly separate the multiple deployment locations for ROAM-V. For the ROAM-V DRUM, substrates were changed every deployment and transported to Texas A&M for storage in -80C freezer until analysis. At Texas A&M, ice nucleation experiments were conducted to measure the ice nucleation temperature of the ambient aerosol samples collected from the three DRUMs using our previously established procedures (Alsante et al., 2023; Fornea et al., 2009; Matthews et al., 2023). For ice nucleation, only samples collected on stage 3 were analyzed, given that these are the most relevant size (1.2 to 0.34 μm diameter) for potential ice nucleating particles. For the AMF1 and ANC sites, we cut and analyzed 2 mm (2-hour) samples. We analyzed the time periods of the AMF1 site instrument when the ROAM-V was deployed. A 72-hour period from July 11th at 23:49 through July 15th at 1:49 was analyzed from the ANC site instrument. For the ROAM-V instrument, we separated the daily samples by site location. Between 1- and 6-hour independent samples were analyzed at each location. We also cut the ROAM-V samples in half to allow for compositional analysis of the aerosol on the other half of the substrate. All viable samples from the ROAM-V were analyzed. Analysis was done using a custom-built ice nucleation apparatus, recently updated to include an array of 16 individual samples (Matthews et al., 2023). On our experimental setup, we used 100 μL of Ultra-High-Performance Liquid Chromatography (UHPLC) water (Sigma Aldrich, >99.9% purity) to wash off the aerosol from the DRUM substrate. Then, we micropipetted 2 μL droplet samples into each of the 16 wells of the array, using hydrophobically coated microscope slides. Experiments would cycle 28 times from 10 C to -40C over a 20-hour period. During analysis of the TRACER samples, nine experiments were conducted with UHPLC water process blanks that followed an identical preparation procedure. The average freezing temperature and standard deviation for these process blanks is -27.7±2.4 C. This data was collected for ARM Field Campaign AFC07023 and supported by DOE ASR grant DE-SC0021047. For any further questions, please feel free to contact the instrument PI, Sarah D. Brooks, sbrooks@tamu.edu. Alsante, A. N., Thornton, D. C., & Brooks, S. D. (2023). Ice nucleation catalyzed by the photosynthesis enzyme RuBisCO and other abundant biomolecules. Communications Earth & Environment, 4(1), 51. Fornea, A. P., Brooks, S. D., Dooley, J. B., & Saha, A. (2009). Heterogeneous freezing of ice on atmospheric aerosols containing ash, soot, and soil. Journal of Geophysical Research: Atmospheres, 114(D13). DOI:10.1029/2009JD011958 Matthews, B. H., Alsante, A. N., & Brooks, S. D. (2023). Pollen Emissions of Subpollen Particles and Ice Nucleating Particles. ACS Earth and Space Chemistry.

54 ENVIRONMENTAL SCIENCES↗

Boride-based Ceramic Super-high Temperature Thermocouples in Harsh Environments (Final Scientific/Technical Report)

An electromotive force (emf) can be generated along a temperature gradient between the cold end and hot end of a thermoelectric material, termed the Seebeck effect. Based on the Seebeck effect, metallic alloys have been extensively employed to detect temperatures for centuries, named thermocouples. However, commercially available thermocouple alloys suffer from limitations, such as oxidation, chemical degradation, and poor long-term stability under high-temperature harsh environments. This DOE-funded project aimed to develop high-temperature, chemically tolerant thermocouples suitable for operation in extreme environments relevant to semiconducting thermoelectric materials. The research focused on boride-based semiconducting thermoelectric compounds as candidates for next-generation thermocouples with enhanced oxidation resistance, chemical stability, and thermal robustness under conditions representative of charcoal-fired electricity facilities. During the funded years, boride materials were synthesized using an arc-plasma technique under ambient air and argon atmospheres, enabling scalable and cost-effective production compared with conventional boride fabrication methods. The synthesized borides were processed into nanostructured powders, followed by consolidation into dense bulk materials using a spark plasma sintering (SPS) bottom-up approach. Comprehensive characterization was performed, including microstructural analysis, electrical transport measurements, and optical and thermal property evaluation. Both p-type and n-type boride electric legs were fabricated and integrated into boride-based thermocouples. The thermal and irradiation stabilities of the boride nanomaterials and bulk thermoelectric materials were systematically evaluated to assess suitability for long-term operation in harsh environments. Additionally, 12 students were broadly hands-on trained spanning the full research workflow, including word processing and technical editing (e.g., LATEX for manuscript and poster preparation), data collection and analysis (using Python and related libraries and hardware interfaces), sample preparation (including arc-plasma synthesis and spark plasma sintering), and advanced characterization techniques (such as X-ray diffraction, UV–vis spectroscopy, electron microscopy, differential thermal analysis (DTA), and Seebeck coefficient measurements, etc). Overall, this project demonstrated the feasibility of boride-based thermoelectric materials as durable high-temperature thermocouples, providing a promising pathway toward robust temperature sensing technologies aligned with DOE energy infrastructure and extreme-environment monitoring needs.

20 FOSSIL-FUELED POWER PLANTS↗

First-Order Individual Gas Sensors as Next Generation Reliable Analytical Instruments

It is conventionally expected that the performance of existing gas sensors may degrade in the field compared to laboratory conditions because (i) a sensor may lose its accuracy in the presence of chemical interferences and (ii) variations of ambient conditions over time may induce sensor-response fluctuations (i.e., drift). Breaking this status quo in poor sensor performance requires understanding the origins of design principles of existing sensors and bringing new principles to sensor designs. Existing gas sensors are single-output (e.g., resistance, electrical current, light intensity, etc.) sensors, also known as zero-order sensors (Karl Booksh and Bruce R. Kowalski, Analytical Chemistry, DOI: 10.1021/ac00087a718). Any zero-order sensor is undesirably affected by variable chemical background and sensor drift that cannot be distinguished from the response to an analyte. To address these limitations, we are developing multivariable gas sensors with independent responses, which are first-order analytical instruments. Here, we demonstrate self-correction against drift in two types of first-order gas sensors that operate in different portions of the electromagnetic spectrum. Our radiofrequency sensors utilize dielectric excitation of semiconducting metal oxide materials on the shoulder of their dielectric relaxation peak and achieve self-correction of the baseline drift by operation at several frequencies. Our photonic sensors utilize nanostructured sensing materials inspired by Morpho butterflies and achieve self-correction of the baseline drift by operation at several wavelengths. These principles of self-correction for drift effects in first-order sensors open opportunities for diverse emerging monitoring applications that cannot afford frequent periodic maintenance that is typical of traditional analytical instruments.

Potyrailo, Radislav A.↗

Mechanistic and Electronic Insights into a Working NiAu Single-Atom Alloy Ethanol Dehydrogenation Catalyst

Elucidation of reaction mechanisms and the geometric and electronic structure of the active sites themselves is a challenging, yet essential task in the design of new heterogeneous catalysts. Such investigations are best implemented via a multi-pronged approach that comprises ambient pressure catalysis, surface science, and theory. Herein, we employ this strategy to understand the workings of NiAu single-atom alloy (SAA) catalysts for the selective non-oxidative dehydrogenation of ethanol to acetaldehyde and hydrogen. The atomic dispersion of Ni is paramount for selective ethanol to acetaldehyde conversion, and we show that even the presence of small Ni ensembles in the Au surface results in the formation of undesirable byproducts via C-C scission. Spectroscopic, kinetic, and theoretical investigations of the reaction mechanism reveal that both C-H and O-H bond cleavage steps are kinetically relevant and single Ni atoms are confirmed as the active sites. X-ray absorption spectroscopy studies allow us to follow the charge of the Ni atoms in the Au host before, under, and after a reaction cycle. Specifically, in the pristine state the Ni atoms carry a partial positive charge which increases upon coordination to the electronegative oxygen in ethanol and decreases upon desorption. Furthermore, this type of oxidation state cycling during reaction is similar to the behavior of single-site homogenous catalysts. Given the unique electronic structure of many single-site catalysts, such a combined approach in which the atomic-scale catalyst structure and charge state of the single atom dopant can be monitored as a function of its reactive environment is a key step towards developing structure function relationships that inform the design of new catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dielectric Resonator Design for Low Power and Low Temperature Microwave Plasma

Waveguide-based microwave plasmas generally operate at high temperatures (2000 - 6000K)[1], making it difficult to directly interface solid materials with the plasma without significant thermal damage. Dielectric microwave resonators (DMRs), long studied for wave-based manipulation of electromagnetic radiation for telecom and optics, can focus radiation to extremely small mode volumes, creating intense localized fields with low-power input.[2] This phenomenon can be used for applications ranging from efficient plasma electronics to near-ambient plasma-materials interactions. Such DMR-based plasmas have been demonstrated a handful of times in the literature, but the majority of research towards this utilize the lowest frequency resonance mode.[3], [4], [5] By carefully controlling the geometry of cylindrical resonators, a variety of electromagnetic modes can be excited. In this work, COMSOL Multiphysics simulations are used to study the electric field enhancement and absorption properties of CaTiO3 DMRs as a function of geometry and excitation frequency. Whereas previous studies have utilized the HEM111 resonance frequency to drive low power plasma excitation, we find that higher order resonance frequencies are more effective at field enhancement and result in less power loss within the dielectric material, hence less wasted heating. The effectiveness of these modes is also geometry dependent and can be computationally optimized for plasma generation. Complementing these computational efforts, we demonstrate a new closed-system reactor design built in a WR-650 waveguide and experimentally demonstrate the formation of atmospheric argon microwave plasma using < 30 W input power on DMR dimers. We observe a shifting resonance frequency as the DMRs heat in response to microwave excitation and develop a Python-based lock-in mechanism to effectively track the DMR resonance over time, leading to stable plasma operation. We use infrared thermal imaging to monitor the temperature of the DMR dimers and surrounding quartz chamber, demonstrating thermal temperatures < 60 degreesC. Finally, we utilize optical emission spectroscopy (OES) to probe the plasma properties as a function of the resonance mode.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fine particulate matter source apportionment for the chemical speciation trends network site at Birmingham, Alabama, using positive matrix factorization

The Positive Matrix Factorization (PMF) receptor model version 1.1 was used with data from the fine particulate matter (PM2.5) Chemical Speciation Trends Network (STN) to estimate source contributions to ambient PM2.5 in a highly industrialized urban setting in the southeastern United States. Model results consistently resolved 10 factors that are interpreted as two secondary, five industrial, one motor vehicle, one road dust, and one biomass burning sources. It was found that most PMF factors did not cleanly represent single source types and instead are 'contaminated' by other sources. Secondary particulate matter formed by atmospheric processes, such as sulfate and secondary OC, contribute the majority of ambient PM2.5 and exhibit strong seasonality 37 {+-} 10% winter vs. 55 {+-} 16% summer average. Motor vehicle emissions constitute the biggest primary PM2.5 mass contribution. In summary, this study demonstrates the utility of the EC tracer method to effectively blank-correct the OC concentrations in the STN dataset. In addition, examination of the effect of input uncertainty estimates on model results indicates that the estimated uncertainties currently being provided with the STN data may be somewhat lower than the levels needed for optimum modeling results. An appendix , available to members on the website www.awma lists stationary sources of PM2.5 within 10 km of the NHBM site and PM2.5 emissions greater than 1 ton per year. 71 refs., 7 figs., 9 tabs.

01 COAL, LIGNITE, AND PEAT↗

Performance of MODIS Thermal Emissive Bands On-orbit Calibration Algorithms

Two nearly identical copies of the Moderate Resolution Imaging Spectroradiometer (MODIS) are currently operated on-board the Terra and Aqua spacecrafts, launched in December 1999 and May 2002, respectively. Together, they have produced an unprecedented amount of science data products, which are widely used for the studies of changes in the Earth's system of land, oceans, and atmosphere. MODIS is a cross-track scanning radiometer, which uses a two-sided scan mirror and collects data continuously over a wide scan angle range (+/-55 degree relative to the instrument nadir) each scan of 1.47 seconds. It has 36 spectral bands with wavelengths ranging from visible (VIS) to long-wave infrared (LWIR). MODIS bands 1-19 and 26 are the reflective solar bands (RSB) and bands 20-25 and 27-36 are the thermal emissive bands (TEB). MODIS was developed and designed with improvements made over its heritage sensors (such as AVHRR and Landsat) and, in particular, with more stringent calibration requirements. Because of this, MODIS was built with a set of state-of-art on-board calibrators (OBC), which include a solar diffuser (SD), a solar diffuser stability monitor (SDSM), a blackbody (BB), a spectroradiometric calibration assembly (SRCA), and a space view (SV) port. With the exception of view angle differences, MODIS OBC measurements and the Earth View (EV) observations are made via the same optical path. MODIS TEB have a total of 160 individual TEB detectors (10 per band), which are located on two cold focal plane assemblies (CFPA). For nominal on-orbit operation, the CFPA temperature is controlled at 83K via a passive radiative cooler. For the TEB, the calibration requirements at specified typical scene radiances are less than or equal to 1% with an exception for the fire detection (low gain) band. MODIS TEB on-orbit calibration is performed on a scan-by-scan basis using a quadratic calibration algorithm, and data collected from sensor responses to the onboard BB and SV. The BB serves as the thermal calibration source and the SV provides measurements for the sensor's background and offsets. MODIS on-board BB is a v-grooved plate with its temperature measured using 12 platinum resistive thermistors (PRT) uniformly embedded in the BB substrate. All the BB thermistors were characterized pre-launch with reference to the NIST temperature standards. Unlike typical BB operations in many heritage sensors, which have no temperature control capability, the MODIS on-board BB can be operated at any temperatures between instrument ambient (about 270K) and 315K and can also be varied continuously within this range. This feature has significantly enhanced the MODIS' capability of tracking and updating the TEB nonlinear calibration coefficients over its entire mission. Following a brief description of MODIS TEB on-orbit calibration methodologies and its onboard BB operational activities, this paper provides a comprehensive performance assessment of MODIS TEB quadratic calibration algorithm. It examines the scan-by-scan, orbit-by-orbit, daily, and seasonal variations of detector responses and associated impact due changes in the CFPA and instrument temperatures. Specifically, this paper will analyze the contribution by each individual thermal emissive source term (BB, scan cavity, and scan mirror), the impact on the Level 1 B data product quality due to pre-launch and on-orbit calibration uncertainties. A comparison of Terra and Aqua TEB on-orbit performance, lessons learned, and suggestions for future improvements will also be made.

Xiong, Xiaoxiong↗

Investigating the Effects of Exposure to Blue-Enriched Light or Peppermint Odor on Alertness, Mood, and Performance Upon Awakening from Deep Sleep at Night

Introduction: Sleep inertia refers the transient neurobehavioral impairments experienced immediately after waking from sleep. This period of reduced alertness and performance poses a significant safety risk to on-call workers who may be required to perform a safety-critical task immediately after waking (e.g., emergency services, health care, and military). In these operations, the need for a rapid return to full alertness is critical to mission safety and success. Several factors may exacerbate sleep inertia, resulting in greater impairment upon waking, including: waking from deep sleep, (i.e., slow wave sleep, SWS), waking at night, and waking following prior sleep loss. Awakenings under these conditions are common for on-call and extended shift workers who may need to perform safety-critical tasks soon after waking from unprotected sleep opportunities. Therefore, there is a need for evidence-based reactive countermeasures (i.e., used upon waking) to the cognitive consequences sleep inertia. Specifically, countermeasures that can rapidly restore alertness and performance immediately following sleep. A recent review of the literature on reactive countermeasures highlighted several research gaps and promising candidates for further investigation. The review also emphasized the need for countermeasures that are operationally viable and readily deployed in occupational settings. This study aims to address the identified gaps and limitations by assessing the efficacy of exposure to two known acute alerting stimuli - blue-enriched light and peppermint odor - to improve cognitive performance, alertness, and mood immediately after waking from SWS at night. Materials and Methods: Twelve participants completed a two-week within-subject, randomized, cross-over intervention study including two in-laboratory overnight visits. During each experimental week, the subjects experienced one intervention (light or peppermint) and a control condition upon awakening from SWS at night. The presentation order of the two conditions (intervention or control) at wake-up and the order of intervention (light or peppermint) by week was randomized by sex. Prior to each in-laboratory visit, participants maintained a sleep schedule of 8.5 h for 5 nights and 5 h for one night. Compliance with this sleep schedule was confirmed by actigraphy. In the laboratory, participants went to bed at their habitual bedtime and were monitored by standard polysomnography. After at least five minutes of continuous SWS, participants were awoken and exposed, in a randomized order, to either the control or intervention condition. During the hour after awakening from SWS (at 2, 17, 32, and 47 minutes after waking), participants completed a battery of tasks including a 5-minute psychomotor vigilance task (PVT), a subjective scale of alertness (Karolinska Sleepiness Scale, KSS), and visual analogue scales (VAS) of mood. Following this sleep inertia measurement period, all lights were turned off and participants were allowed to return to sleep. They were then awoken again from their subsequent SWS period and exposed to the alternative condition (control or intervention). Following this second awakening, participants were allowed to sleep until their habitual wake time and were then released from the laboratory. Participants then followed the at-home sleep schedule and returned to the laboratory for the second intervention (light or peppermint) following the procedures described above. The light intervention involved exposure to a blue-enriched light canvas illuminated for 1 hour at a distance of ~56 cm from the participant (~200 lux and ~60 melanopic lux at angle of gaze). For the peppermint intervention, peppermint oil was pipetted onto a mask, and participants inhaled the odor with the mask covering the nose and mouth for 1 minute. The control condition for both weeks involved a dim, red ambient light (<1 lux). An odorless mask, without any oil pipetted onto the mask, was also worn in the peppermint control condition. Results: Compared to the control condition, participants exposed to blue-enriched light had fewer PVT lapses (χ2 = 5.285, p = .022), reported feeling more alert (KSS: F1,77 = 4.955, p = .029; VASalert: F1,77 = 8.226, p = .005), and had improved mood (VAScheerful: F1,77 = 8.615, p = .004; VASdepressed: F1,77 = 4.649, p = .034; VASlethargic: F1,77 = 5.652, p = .020). Exposure to peppermint oil did not improve any outcome measures on any of the tasks compared to control condition (p > .05). Conclusions: We found that participants had fewer lapses of attention upon awakening when exposed to blue-enriched light compared to dim, red light. In addition, participants reported feeling more alert, more cheerful, less depressed, and less lethargic in the blue-enriched light condition. Brief exposure to a peppermint odor, however, did not appear to improve performance, alertness, or mood under the experimental conditions. Our null results in the peppermint condition may have been due to methodological limitations such as the duration and method of administration. Given the need to mitigate the potential impact of sleep inertia on safety-critical tasks in on-call operations, our findings suggest that blue-enriched light exposure upon awakening may help to improve performance and alertness during the sleep inertia period following awakening from deep, nocturnal sleep. We are currently exploring the potential mechanisms for the effect of light on cognitive performance upon awakening as well as investigating its application in real-world settings to explore the translational efficacy of this countermeasure to occupational environments. Continued exploration into light and other reactive countermeasures, and potentially their combination, is needed in order to provide evidence-based guidance on effective sleep inertia countermeasures to improve the alertness and performance of those required to perform safety-critical tasks soon after waking.

sleep inertia↗