Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Administration and Management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Semiannual Categorical Process Report - January Through June 2023

The Sandia National Laboratories, in California (SNL/CA) is a research and development facility, owned by the U.S. Department of Energy’s National Nuclear Security Administration agency (DOE/NNSA). The laboratory is located in the City of Livermore (the City) and is comprised of approximately 410 acres. The SNL/CA facility is operated by National Technology and Engineering Solutions of Sandia, LLC (NTESS) under a contract with the DOE/NNSA. The DOE/ NNSA’s Sandia Field Office (SFO) oversees the operations of the site. North of the SNL/CA facility is the Lawrence Livermore National Laboratory (LLNL), in which SNL/CA’s sewer system combines with before discharging to the City’s Publicly Owned Treatment Works (POTW) for final treatment and processing. The City’s POTW authorizes the wastewater discharge from SNL/CA via the assigned Wastewater Discharge Permit #1251 (the Permit), which is issued to the DOE/NNSA’s main office for Sandia National Laboratories, located in New Mexico (SNL/NM). The Monitoring and Reporting Condition 2.B of the Permit requires compliance with the semiannual reporting requirements contained in federal categorical pretreatment standards regulations (40 CFR 403.12). These regulations set numerical limits on the concentration of pollutants allowed to discharge from certain categories of industrial processes. This report is submitted to the City to satisfy this reporting requirement.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Damaged Fuel in the United States

Over the years of commercial nuclear power plant operations in the United States (U.S.), many fuel assemblies have lost the capability to perform all of their desired functions. These assemblies have lost the capability to be handled, stored, or transported to meet regulations resulting in them being classified as damaged fuel. The causes of these failed assemblies are diverse and plant-specific. The majority of these failed assemblies are contained in a damaged fuel can that will be used in conjunction with a storage and/or transportation system. The storage and transportation systems have a limit on how many slots can be filled with damaged fuel cans. A damaged fuel can is generally a stainless steel container that confines damaged SNF and is closed on its end by screened openings. These screened openings allow gaseous and liquid media to escape but minimize the dispersal of gross particulate material. Out of an abundance of caution a few reactors have loaded high burnup fuel into damaged fuel cans. Damaged fuel is not licensed for storage or transport in the U.S., because the regulations for storage and transport do not specify exactly how to classify damaged fuel. Instead the regulations license/certify packages that specify approved contents. Damaged fuel must be included in the approved contents to be a viable option. In many cases damaged SNF is encapsulated in a damaged fuel can to ensure it can confine gross fuel particles, debris, and or damaged assemblies to a known volume within a loaded cask. This damaged fuel can may then be utilized in the same way as an assembly in a storage and transportation design system. Some storage cask systems utilize top and bottom plugs to confine debris in damaged fuel. The most recent domestic documentation on damaged SNF was performed by the U.S. Energy Information Administration (EIA) and used data from U.S. reactors concluding in June 30th 2013 to produce Form GC-859, “Nuclear Fuel Data Survey”. Based on this form there were 136,821 boiling water reactor (BWR) spent nuclear fuel (SNF) assemblies and 104,647 pressurized water reactor (PWR) SNF assemblies for a total of 241,468 SNF assemblies in the U.S. Out of these 241,468 SNF assemblies, 4,521 assemblies were classified as failed. Some assemblies were also disassembled and the fuel rods or pieces of fuel rods were combined together to make a consolidated assembly. A consolidated assembly may include damaged fuel, or it could have been consolidated as part of a demonstration project. The GC-859 data includes 2,550 consolidated assemblies containing between 0 and 264 whole fuel rods. These consolidated assemblies could be placed in single assembly canisters and stored in the spent fuel pool. For dry storage and transportation, a single assembly canister is generally placed in a damaged fuel can. In addition to the consolidated assemblies, 2,391 uncanistered fuel rod pieces exist, which were removed from 494 assemblies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analysis of Respirator Cartridge Performance Testing on a Hanford AP Tank Farm Primary Exhauster Slipstream

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the exhauster for the Hanford AP tank farm. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from June 24-26, 2016, on a slipstream from the AP exhauster fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on a Hanford AN Tank Farm Exhauster Slipstream

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators to determine the period of time that the cartridges would provide adequate performance to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the exhauster at the Hanford AN tank farm. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing cartridge change schedule. Testing is commonly applied in situations where mixtures of COPCs exist and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from September 30−October 2, 2016, on a slipstream from the AN Exhauster under static conditions fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on a Hanford Tank SY-102

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air-purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors emanating from the headspace of tank SY-102 on the Hanford Site. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedule. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, worker breathing rate, and cartridge adsorption capacity. Testing was conducted from July 8–10, 2016, on headspace vapors from Hanford tank SY-102 under static conditions fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on the 702-AZ Primary Exhauster for the Hanford AY/AZ Tank Farms

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators to determine the period of time that the cartridges would provide adequate performance to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the 702-AZ primary exhauster for the Hanford AY/AZ tank farms. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from August 26–28, 2016, on a slipstream from the 702-AZ exhauster, under static conditions fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1(SCOTT Safety, Monroe, North Carolina) were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge, and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and change-out frequency.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Respirator Cartridge Performance Testing on the 702-AZ Primary Exhauster for the Hanford AY/AZ Tank Farms during a Waste-Disturbing Event

Washington River Protection Solutions (WRPS) conducted tests using two types of chemical cartridges for use in air-purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 for APRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the 702-AZ Primary Exhauster for the Hanford AY-AZ tank farms. Unlike prior cartridge testing on the 702-AZ Primary Exhauster, the recent tests were performed during a waste-disturbing event. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from February 10–11, 2017, on a slipstream from the 702-AZ exhauster fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina), were assessed on separate days. Sample media (sorbent tubes) and canisters (e.g., Summa) sampling were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Baseline Hypothetical Facility for the Production of 131 I and 99 Mo using Activation Targets

This report describes a hypothetical facility for production of medical radioisotopes via activation under the Proliferation Resistance and Optimization (PRO-X) program. The facility uses neutron activation of non-special nuclear material (SNM) to produce the medical isotopes 131 I and 99 Mo at a throughput of 60 Ci/week of 131 I and 5 Ci/week of 99 Mo. The hypothetical design was carried out using a 10 MWt research reactor. The precursors used for the activation process were TeO2 for 131 I and MoO 3 for 99 Mo. The processes are performed in 3 hot cells used for target receipt, extraction, purification low specific activity (LSA) generator introduction, and packaging. A fourth hotcell is used for waste processing. The hot cell processing area takes up a footprint of 15.4 m 2 with the total footprint of the facility, including space for administrative offices, non-rad labs, quality assurance, and radiation buffer areas set at 763 m 2 . Waste is produced at a weekly rate of 257.8 g low activity solid waste and 8032.7 mL of low activity liquid waste, 8032 mL of which is water. This baseline hypothetical facility for production of medical isotopes via activation was then compared and contrasted to the hypothetical facility for production of medical isotopes via fission products to show the differences in approach for the two production modes. The two production modes had several highlighted differences including the overall facility and hot cell layout, the type and amount of waste produced by the respective facilities, and economic factors impacting production mode. Finally, a decision tree for which production mode might be more beneficial for an entrant into medical isotope production was developed based on the differences examined and the desired output of medical isotopes desired by the entrant.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Giant Undulations Driven by Pitch‐Angle Scattering of Time Domain Structures Modulated by Plasmapause Surface Wave

Abstract Plasmapause surface waves (PSWs) near the plasmapause boundary are regarded to be the magnetospheric source of ionospheric auroral giant undulations (GUs) located at the equatorward boundary of diffuse aurora. However, the observational evidence of wave‐particle interaction connecting PSWs and GUs is absent. In this letter, we demonstrate GUs are driven by pitch‐angle scattering of time domain structures modulated by the PSWs, based on the conjugated ionospheric and magnetospheric observations. Specifically, ionospheric GUs are lighted by the pitch‐angle scattering of <1 keV thermal electron and ions and energetic ions with energy up to dozens of keV near the plasmapause. Further, the total fluxes during one PSW period and energy of scattered electron and ions determine the size and luminosity of GUs. Our research provides observational evidence that PSWs cause periodic electron precipitation via modulating the time domain structures rather than the previously predicted chorus or electron cyclotron harmonic waves.

Zhou, Yi‐Jia [Weihai Institute for Interdisciplina↗

Cybersecurity for Distance Relay Protection

This project is a DOE follow-up effort on the CREDC workshop held on September 13, 2018 in Cambridge, MA to discuss cybersecurity of distance relays, which considered the benefits, vulnerabilities and risk mitigations for the use of communication systems in power system protection. The objectives of this project are to define the taxonomy of relay protection and associated communications; define use cases describing approaches to reduce the cyber-attack surface on those protective relays; and evaluate the loss of operational functional capability from changes to communication coverage. Mitigating controls will also be evaluated to understand if there are other approaches to reduce attack surfaces while maintaining communications or partial communications. Distance relays are used to protect transmission lines of approximately 10 to 300 miles in length, by detecting short circuits (i.e., faults) on the lines and then tripping circuit breakers in the substation. Such protection systems are a subset of the power system and they incorporate sensing, logic and communication functions. Protection system exposure to cyberattack could be drastically limited by disconnecting relays from all vulnerable communication systems, but this may adversely impact overall power system performance in the absence of cyberattack. This project began with a use case analysis of protection systems with communications, as summarized in this report. It continued with modeling, testing and evaluation in a miniature power system (MPS), located in the Western Area Power Administration (WAPA) Electric Power Training Center (EPTC). The project also incorporated feedback from two industry meetings held in February and September 2019. The suggested next steps account for and complement the work already underway with DOE/CESER funding: 1. Study the performance of LCD and PC vs. PUTT, which is less reliant on communication system performance and GPS timing references. The PUTT scheme could prove to be more resilient to cyberattack or communications-related disruption. It could also be more tolerant of message re-routing with SDN/SDR communication systems. On the other hand, it will be more vulnerable to false tripping during dynamic events or to loss of the voltage signal. The optimum choice of scheme may depend on the specific power system and risk assessment. This study could provide a new template for evaluation based on business functions. 2. Research and develop new methods to detect and monitor distributed physical attacks, possibly using drones, video sensors, thermal sensors, machine learning and other advanced techniques. This will help mitigate the impact of cyberattack on the protection system, and will also help mitigate the impact of wild fires. 3. Implement a scalable PKI for use in electric utility protection systems. This will encourage widespread adoption of secure authentication methods that are already available, but not widely used at present. This will help secure engineering access to the relays. 4. Investigate the use of SDN in combination with SDR to achieve better cybersecurity and electromagnetic security of the network, incorporating path variability. This would help secure both engineering access and peer-to-peer GOOSE messaging. 5. Perform additional testing, with operator evaluation of “red button” scenarios, PUTT vs. LCD, relay mis-operations, and other cyberattacks in the EPTC. This is an important advantage of testing in the EPTC rather than by computer simulation or even hardware-in-the-loop simulation; the EPTC is already dedicated to managing the situational awareness, operator response times and other human impacts. One of the project objectives was to settle on a common nomenclature for this problem space. We have concluded that the OSI layer model, supplemented by ANSI device numbers and other IEEE standards, is already well-accepted by the industry. The IEEE PSRC knowledge base provides a great deal of public information

24 POWER TRANSMISSION AND DISTRIBUTION↗

Identification of drug repurposing candidates for amyotrophic lateral sclerosis using electronic health records: a retrospective cohort study

Amyotrophic lateral sclerosis (ALS) is a progressive neurodegenerative disease with a life expectancy of only 3–5 years and few approved treatments. To identify drug repurposing candidates for the treatment of ALS, we analysed the electronic health records (EHRs) of a large cohort of military veterans with ALS. We analysed the EHRs of individuals in the US Veterans Health Administration (VHA) database who were diagnosed with ALS between Jan 1, 2009 and Dec 31, 2019 to assess medication effects. Individuals without recorded prescriptions after the date of diagnosis were excluded. Two sets of criteria were applied to ascertain exposure. Exposure criteria A were met if the dispense date or the end date of the medication was within 12 months of ALS diagnosis and the end date was at least 6 months after the dispense date. Exposure criteria B were met if there were at least two dispenses within 6 months before diagnosis and 12 months after diagnosis. Propensity score-matched control groups were generated on the basis of confounders included in the EHR, with methodology of potential outcomes used to infer treatment effects. The primary outcome was death. A standard Cox proportional hazards analysis was done to assess association with survival. Survival was defined as the time from diagnosis date recorded in the EHR to death reported in the Department for Veterans Affairs Vital Status File. Follow-up survival time was censored on Dec 31, 2020, for those alive on this date. Downstream protein targets of drugs with clinically significant effects were analysed using the protein–protein interaction networks-based algorithm PathFX. The EHRs of 11 003 individuals with ALS in the VHA database were appropriate for analysis. 162 medications with treatment groups of 30 or more individuals were identified. Among these 162 medications, 27 were associated with statistically significant changes (≥0·1) in the hazard ratio (HR) for death. 18 of the medications were associated with a reduced HR for death (prolonged survival), and nine were associated with an increased HR for death (reduced survival). Drugs associated with reduced HR included HMG-CoA reductase inhibitors (simvastatin, pravastatin, lovastatin, and atorvastatin), PDE5 inhibitors (vardenafil and sildenafil), and α-adrenergic antagonists (tamsulosin and terazosin). The medications associated with an increased HR were drugs used either in the management of clinical features of ALS associated with poor outcomes or in end-of-life care. PathFx analysis identified a complex of proteins interacting with several of the identified drugs. To our knowledge, this analysis is the largest EHR-based study for identifying drug repurposing candidates for ALS. We identified several drugs that warrant further assessment as therapeutic options in ALS, as well as a protein network complex that might serve as a therapeutic target for ALS.

Reimer, Richard J. [Stanford Univ., CA (United Sta↗

Analysis of Air-Purifying Respirator (APR) Cartridge Performance Testing on Hanford Tanks SX-101 and SX-104 (Vol.1)

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air-purifying respirators to determine the period of time that the cartridges would provide adequate performance1 to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from vapors exiting the headspaces of Hanford tanks SX-101 and SX-104. The Occupational Safety and Health Administration (OSHA) considers cartridge testing a valid approach for establishing cartridge change schedules.2 Testing is commonly applied in situations where mixtures of COPCs exist and where other approaches such as manufacturer recommendations and modeling are less reliable. The tests were designed and conducted to ensure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from June 16-17, 2017, and June 23-24, 2017, using headspace vapors from Hanford tank SX-104 and Hanford tank SX-101, respectively. Headspace vapors under static conditions were fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and SCOTT 7422-SC1 (SCOTT Safety, Monroe, North Carolina), were assessed on separate days. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridges, and subsequently were analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Test for Reconditioning RA Waste with Simulated Bitumen and Concrete in a 1,2 MW Plasma Test Facility - 20092

The operation and maintenance of nuclear power plants, the non nuclear fuel cycle, etc generate low-level radioactive waste which, along with the historical radioactive waste from past nuclear activities, needs to be treated and stored, awaiting final disposal. Plasma technology offers a very effective way of treating this waste with a high volume reduction factor (VRF), free from organics, liquids and moisture, and meets without a doubt the acceptance criteria for safe storage and disposal. By means of a plasma beam of approximately 5000 deg. C, the inorganic materials are melted into a glassy slag, containing most of the radioactive isotopes while the organic material is gasified, oxidized and purified in an off-gas cleaning system. First the paper describes the new full-scale Plasma Melting Facility (PMF) at the Kozloduy Nuclear Power Plant in Bulgaria which was taken in nuclear operation In May 2018. The plant has a capacity of 250 tons per year and the maximum contact dose rates of the incoming waste is 2 mSv/h. Different mixtures of radioactive waste packed in 200 l drums were successfully treated resulting in a glassy slag free from liquids and organic material with an important volume reduction factor (VRF). The Project was co-financed through a grant by Kozloduy International Decommissioning fund (KIDSF) administrated by the EBRD through Bulgarian national funding. Plasma is a suitable technology for treatment of problematic waste or even reconditioning waste so Belgoprocess was contracted to do plasma tests with simulated conditioned waste types. One can do tests on a laboratory scale on smaller samples and torch capacities of e.g. 50 kW but Belgoprocess wanted to do more realistic and reliable tests. So Belgoprocess contracted Phoenix Solutions Co who has a full-scope test facility equipped with a 1200 kW plasma torch for full-scope treatment of simulated conditioned waste. For a first confidential contract simulated 200 l (55 gallon) bitumen drums were treated. The drums contained different pucks of compacted waste such as rags, used filters, granulates, etc. The pucks were stacked in the 200 l drums and subsequently embedded with bitumen. A total of 6 drums were treated in the plasma facility. For a second contract simulated homogeneous 200 l (55 gallon) concrete drums with on the one hand concentrates and on the other hand spent resins were selected. A total of 6 drums with concrete and spent resins were treated and melted in the plasma testing facility. The paper describe the test facility, volume reduction factor (VRF) of different waste streams and most important parameters. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Section 106 Recordation, Interpretation, and Documentation for the Demolition of Buildings 9201-5 and 9204-4, Y-12 National Security Complex, Oak Ridge, Tennessee

In 2019 and 2020, Cultural Resource Analysts, Inc. (CRA), began preparing recordation packages for 18 World War II and Cold War Era buildings slated for demolition at the request of Consolidated Nuclear Security, LLC (CNS), on behalf of the U.S. Department of Energy (DOE), National Nuclear Security Administration (NNSA). The recordations for these 18 buildings, which are located within what is now known as the Y-12 National Security Complex (Y-12) in Oak Ridge, Tennessee, were prepared and submitted in two separate packages. The first report (EC-NP-004) was prepared as a mitigation measure to address adverse effects that will result from the proposed demolition of 16 support and ancillary buildings. The current report is the second of the two packages and addresses the last two of the 18 buildings slated for demolition (9201-5 and 9204-4), which are two of the large process buildings located at Y-12. All 18 of these buildings have previously been determined eligible for listing in the National Register of Historic Places (NRHP). The two buildings, Building 9201-5 and Building 9204-4, are located south of Bear Creek Road and west of the main Y-12 entrance gate. Both buildings were constructed as uranium enrichment facilities in support of the Manhattan Project, a top-secret World War II mission to develop the world’s first nuclear weapons. Building 9201-5, completed in October 1944, is the Alpha-5 process facility and Building 9204-4, completed in Fall 1945, is the Beta-4 process facility. Over the years, these facilities were repurposed for a number of different functions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of Building 23-620, Los Alamos Scientific Laboratory J-3 Office, Nevada National Security Site, Nye County, Nevada

The U.S. Department of Energy (DOE) National Nuclear Security Administration Nevada Field Office (NNSA/NFO) plans to demolish Building 23-620, the Los Alamos Scientific Laboratory (LASL) J-3 Office Building (Nevada State Historic Preservation Office [SHPO] Resource No. B15283) at the Nevada National Security Site (NNSS) in Nye County, Nevada. The NNSA/NFO is implementing a long-term project to modernize the town of Mercury for future mission needs. The project is considered an undertaking subject to review under Title 54 of United States Code (USC) § 306108, commonly known as Section 106 of the National Historic Preservation Act, Title 54 USC § 300101, et seq., and its implementing regulations, Title 36 of the Code of Federal Regulations (36 CFR) Part 800. In 2018, Desert Research Institute (DRI) completed an architectural survey of the town of Mercury. This effort resulted in the identification, recordation, and evaluation of the Mercury Historic District (MHD, SHPO Resource No. D230), including the identification of its contributing elements (Reno et al. 2018). The MHD was recommended eligible for listing in the National Register of Historic Places (NRHP, National Register) under the Secretary of the Interior’s (SOI) Significance Criteria A and C, as defined in 36 CFR Part 60.4, as a significant concentration of buildings and structures with a direct and important association with Cold War-era nuclear testing from 1951 through 1992. It has not been evaluated under Criteria B and D to date. As part of a larger modernization program for Mercury, the NNSA/NFO and the SHPO executed the 2018 Programmatic Agreement between the National Nuclear Security Administration Nevada Field Office and the Nevada State Historic Preservation Officer regarding Modernization and Operational Maintenance of the Nevada National Security Site, at Mercury in Nye County, Nevada (Mercury PA). The Mercury PA includes streamlined Section 106 procedures for undertakings in the MHD based on contributing element categories. Building 23-620 is identified in Appendix C of the Mercury PA as a Category I contributing element, indicating that it might be individually eligible for the NRHP. It is a historic property for the purposes of Section 106 compliance and subject to the stipulations of the Mercury PA. Per Stipulation VI of the Mercury PA, when the Area of Potential Effect (APE) for an undertaking includes Category I elements, the NNSA/NFO must evaluate the Category I elements for individual NRHP eligibility under all of the SOI Significance Criteria prior to initiating any activity that may affect the elements. The purpose of this report is to evaluate Building 23-620 as a potential individually eligible historic property in fulfillment of Stipulation VI of the Mercury PA. The evaluation detailed herein concludes that Building 23-620 is not individually eligible for listing in the NRHP. Although it retains aspects of integrity and continues to contribute to the MHD, it is not individually significant under any of the SOI Significance Criteria.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of Building 23-702, Los Alamos Scientific Laboratory H-8 Foil Handling Building, Mercury, Area 23, Nevada National Security Site, Nye County, Nevada

The U.S. Department of Energy (DOE) National Nuclear Security Administration Nevada Field Office (NNSA/NFO) plans to demolish Building 23-702, the Los Alamos Scientific Laboratory (LASL) H-8 Foil Handling Building (Nevada State Historic Preservation Office [SHPO] Resource No. B15278) at the Nevada National Security Site (NNSS) in Nye County, Nevada. The NNSA/NFO is implementing a long-term project to modernize the town of Mercury for future mission needs. The project is considered an undertaking subject to review under Title 54 of United States Code (USC) § 306108, commonly known as Section 106 of the National Historic Preservation Act, Title 54 USC § 300101, et seq., and its implementing regulations, Title 36 of the Code of Federal Regulations (36 CFR) Part 800. In 2018, Desert Research Institute (DRI) completed an architectural survey of the town of Mercury. This effort resulted in the identification, recordation, and evaluation of the Mercury Historic District (MHD, SHPO Resource No. D230), including the identification of its contributing elements (Reno et al. 2018). The MHD was recommended eligible for listing in the National Register of Historic Places (NRHP, National Register) under the Secretary of the Interior’s (SOI) Significance Criteria A and C, as defined in 36 CFR Part 60.4, as a significant concentration of buildings and structures with a direct and important association with Cold War-era nuclear testing from 1951 through 1992. As part of the modernization program for Mercury, the NNSA/NFO and the SHPO executed the 2018 Programmatic Agreement Between the National Nuclear Security Administration Nevada Field Office and the Nevada State Historic Preservation Officer Regarding Modernization and Operational Maintenance of the Nevada National Security Site, at Mercury in Nye County, Nevada (Mercury PA). The Mercury PA includes streamlined Section 106 procedures for undertakings in the MHD based on contributing element categories. Building 23-702 is identified in Appendix C of the Mercury PA as a Category I contributing element, indicating that it might be individually eligible for the NRHP. It is a historic property for the purposes of Section 106 compliance and subject to the stipulations of the Mercury PA. Per Stipulation VI of the Mercury PA, when the Area of Potential Effect (APE) for an undertaking includes Category I elements, the NNSA/NFO must evaluate the Category I elements for individual NRHP eligibility under all of the SOI Significance Criteria prior to initiating any activity that may affect the elements. The purpose of this report is to evaluate Building 23-702 as a potential individually eligible historic property in fulfillment of Stipulation VI of the Mercury PA. The evaluation detailed herein concludes that Building 23-702 is not individually eligible for listing in the NRHP. Although it retains aspects of integrity and continues to contribute to the MHD, it is not individually significant under any of the SOI Significance Criteria.

54 ENVIRONMENTAL SCIENCES↗

Report Series: Evaluation, Finding Of Effect, And Mitigation Documentation For Building 23-109, Mercury, Area 23, Nevada National Security Site, Nye County, Nevada

The U.S. Department of Energy (DOE) National Nuclear Security Administration Nevada Field Office (NNSA/NFO) plans to demolish Building 23-109, the Mercury Fire Station/Maintenance/Housing Office (Nevada State Historic Preservation Office [SHPO] Resource No. B15235) at the Nevada National Security Site (NNSS) in Nye County, Nevada. The NNSA/NFO is implementing a long-term project to modernize the town of Mercury for future mission needs. The project is considered an undertaking subject to review under Title 54 of United States Code (USC) § 306108, commonly known as Section 106 of the National Historic Preservation Act, Title 54 USC § 300101, et seq., and its implementing regulations, Title 36 of the Code of Federal Regulations (36 CFR) Part 800. In 2018, Desert Research Institute (DRI) completed an architectural survey of the town of Mercury. This effort resulted in the identification, recordation, and evaluation of the Mercury Historic District (MHD, SHPO Resource No. D230), including the identification of its contributing elements (Reno et al. 2018). The MHD was recommended eligible for listing in the National Register of Historic Places (NRHP, National Register) under the Secretary of the Interior’s (SOI) Significance Criteria A and C, as defined in 36 CFR Part 60.4, as a significant concentration of buildings and structures with a direct and important association with Cold War-era nuclear testing from 1951 through 1992. It has not been evaluated under Criteria B and D to date. As part of a larger modernization program for Mercury, the NNSA/NFO and the SHPO executed the 2018 Programmatic Agreement between the National Nuclear Security Administration Nevada Field Office and the Nevada State Historic Preservation Officer regarding Modernization and Operational Maintenance of the Nevada National Security Site, at Mercury in Nye County, Nevada (Mercury PA). The Mercury PA includes streamlined Section 106 procedures for undertakings in the MHD based on contributing element categories. Building 23-109 is identified in Appendix C of the Mercury PA as a Category I contributing element, indicating that it might be individually eligible for the NRHP. It is a historic property for the purposes of Section 106 compliance and subject to the stipulations of the Mercury PA. Per Stipulation VI of the Mercury PA, when the Area of Potential Effect (APE) for an undertaking includes Category I elements, the NNSA/NFO must evaluate the Category I elements for individual NRHP eligibility under all of the SOI Significance Criteria prior to initiating any activity that may affect the elements. The purpose of this report is to evaluate Building 23-109 as a potential individually eligible historic property in fulfillment of Stipulation VI of the Mercury PA. The evaluation detailed herein concludes that Building 23-109 is not individually eligible for listing in the NRHP. Although it retains some aspects of integrity and continues to contribute to the MHD, it is not individually significant under any of the SOI Significance Criteria.

54 ENVIRONMENTAL SCIENCES↗

The Impact of Ethylenediaminetetraacetic Acid (EDTA) on the Sorption of Nd(III), Th{sup (IV)}, and U(VI) onto Dolomite in WIPP-Relevant Brines, GWB and ERDA-6 - 20356

Storage of legacy, transuranic waste at the Waste Isolation Pilot Plant (WIPP) requires accurate risk models for performance assessments. These models must predict the long-term fate and transport of contaminants in the WIPP and surrounding environment. Laboratory support is necessary for the development of an accurate model through better understanding of contaminant behavior in the WIPP. The WIPP is a deep geologic repository that is characterized by high ionic strength due to evaporite deposits in the Salado formation (porewaters up to 7.4 M). High concentrations of sodium chloride (NaCl), calcium chloride (CaCl{sub 2}), and magnesium chloride (MgCl{sub 2}) are particularly of concern due to their potential impact on solubility and ultimately transport of contaminants of concern. Additionally, ligands capable of forming strong complexes with metals are found in significant concentrations in the WIPP environment due to their disposal from waste processing and formation during degradation of repository components (e.g. cellulose degradation by calcium hydroxide in cement). Consequently, there is a need to investigate the fate and transport of contaminants in the WIPP environment with a focus on the effects of high ionic strength and strongly coordinating ligands. Contaminants of high concern include the actinides (U(VI), Pu(IV), and Am(III)). Laboratory support of the WIPP modeling efforts was provided by this research. A series of batch experiments were utilized to study the impact of ionic strength, contaminant concentration, and the presence of ethylenediaminetetraacetic acid (EDTA) on the sorption of Nd(III), Th(IV), and U(VI) onto dolomite, a carbonate mineral found within the Culebra formation. The Culebra formation is the most transmissive layer above the WIPP, making transport of contaminants the most likely route in previous risk assessments. Two brines specifically designed to imitate conditions within the WIPP environment were used in these experiments. The U.S. Energy Research and Development Administration Well 6 (ERDA-6, 95%) brine simulates a low Mg environment, while the generic weep brine (GWB, 95%) simulates the WIPP environment with a high Mg concentration. Mg is added to the repository in the form of MgO as an engineered barrier and is naturally present in some formations. It is expected to scavenge carbonate from solutions decreasing formation of the highly soluble and competitive uranium-carbonate complexes. EDTA is used during manipulations of nuclear materials due to its ability to form strong, stable complexes with the actinides and may be found in high concentrations (up to 0.08 mM) within the WIPP as waste canisters degrade. Further, it may provide additional avenues for unwanted transport of contaminants. Nd(III) and Th(IV) were used as stable analogues of Am(III) and Pu(IV), respectively, to represent the most common oxidation states of actinides in the WIPP environment in addition to U(VI). The potential for colloid formation was also investigated with low and high concentrations of contaminants (10 and 1000 μg/L) using three size-dependent particle separation steps. The results of this research provide a better understanding of potential behavior of actinides in the presence of EDTA and within WIPP-relevant brines. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗