Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “APS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Interfraction and Intrafraction Setup Variability for Prone Breast Radiation Therapy

Purpose: To report the interfraction and intrafraction setup variation for prone breast radiotherapy and to determine an appropriate clinical tumor volume (CTV) to planning target volume (PTV) margin to account for motion and positional uncertainties. Methods and Materials: Ten consecutive patients were prospectively enrolled in a protocol of accelerated, hypofractionated prone breast irradiation. Portal images were acquired using an electronic portal imaging device in cine mode. Interfraction setup error was determined by comparing the first image from each fraction with the digitally reconstructed radiograph. The intrafraction motion was determined by evaluating every image acquired during each fraction and measuring the maximum displacement of an external fiducial and the breast surface. Mean values and 95% confidence intervals (CI) were calculated. Based on these results, a CTV to PTV expansion was derived using the equation M = 2.5SIGMA{sub tot} + 0.7sigma{sub tot.} Results: The mean interfraction setup variability for the fiducial was 0.08 cm (CI: 0.02-0.14) in the anterior to posterior (AP) direction and -0.04 cm (CI: -0.07-0.00) in the superior to inferior (SI) direction. The mean interfraction variability of the breast surface was -0.14 cm (CI: -0.24 to -0.04) in the AP direction. The mean intrafraction displacements of the fiducial and the breast surface were 0.13 cm (CI: 0.12-0.15) and 0.15 cm (CI: 0.14-0.17), respectively. Using the systematic and random errors for the external fiducial, the calculated CTV to PTV expansion was 1.4 cm. Conclusions: Acceptable interfraction and intrafraction variability were demonstrated. The findings resulted in a CTV to PTV expansion of 1.4 cm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cardiovascular Morbidity After Radiotherapy or Chemoradiation in Patients With Cervical Cancer

Purpose: To evaluate the risk of cardiovascular events (CVE) in patients with cervical cancer treated with radiotherapy or chemoradiation. Methods and Materials: The incidence of CVE in patients treated between 1989 and 2002 by radiotherapy or chemoradiation was compared with a Dutch reference population. Standardized incidence ratios (SIRs) were calculated for myocardial infarction (MI), angina pectoris (AP), congestive heart failure (CHF), cerebrovascular accident (CVA) separately and for any cardiac event combined (MI, AP, and CHF). Results: In 277 patients with a median follow-up of 4.5 years (range, 0.1-17 years) and a median survival of 9.2 years, 27 cardiac events occurred. The 5-, 10-, and 15-year actuarial incidence of any cardiac event were 9, 14, and 16%, respectively. For the whole population, the SIR for MI was elevated (2.05, 95% CI: 1.12-3.43). The radiotherapy group (n = 132) was older and had more cardiovascular risk factors than the chemoradiation group (n = 145). The SIR for MI in the radiotherapy group was 2.88 (95% CI: 1.44-5.15) and in the chemoradiation group 1.00 (95% CI: 0.21-7.47). In multivariate analyses, there was no relation between treatment modality and the risk for MI. Conclusions: In this cohort of cervical cancer patients, an increased risk for developing a MI was observed. This increased risk of MI, in combination with the high prevalence of cardiovascular risk factors in cervical cancer patients, urges the need to explore strategies to reduce their risk for cardiovascular morbidity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Effect of Intrafraction Motion and Residual Setup Error for Hypofractionated Prostate Intensity-Modulated Radiotherapy With Online Cone Beam Computed Tomography Image Guidance

Purpose: To quantify the dosimetric effect and margins required to account for prostate intrafractional translation and residual setup error in a cone beam computed tomography (CBCT)-guided hypofractionated radiotherapy protocol. Methods and Materials: Prostate position after online correction was measured during dose delivery using simultaneous kV fluoroscopy and posttreatment CBCT in 572 fractions to 30 patients. We reconstructed the dose distribution to the clinical tumor volume (CTV) using a convolution of the static dose with a probability density function (PDF) based on the kV fluoroscopy, and we calculated the minimum dose received by 99% of the CTV (D{sub 99}). We compared reconstructed doses when the convolution was performed per beam, per patient, and when the PDF was created using posttreatment CBCT. We determined the minimum axis-specific margins to limit CTV D{sub 99} reduction to 1%. Results: For 3-mm margins, D{sub 99} reduction was {<=}5% for 29/30 patients. Using post-CBCT rather than localizations at treatment delivery exaggerated dosimetric effects by {approx}47%, while there was no such bias between the dose convolved with a beam-specific and patient-specific PDF. After eight fractions, final cumulative D{sub 99} could be predicted with a root mean square error of <1%. For 90% of patients, the required margins were {<=}2, 4, and 3 mm, with 70%, 40%, and 33% of patients requiring no right-left (RL), anteroposterior (AP), and superoinferior margins, respectively. Conclusions: For protocols with CBCT guidance, RL, AP, and SI margins of 2, 4, and 3 mm are sufficient to account for translational errors; however, the large variation in patient-specific margins suggests that adaptive management may be beneficial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Use of the Active Breathing Coordinator Throughout Radical Non-Small-Cell Lung Cancer (NSCLC) Radiotherapy

Purpose: To assess feasibility and reproducibility of an Active Breathing Coordinator (ABC) used throughout radical radiotherapy for non-small-cell lung cancer, and compare lung dosimetric parameters between free-breathing and ABC plans. Methods and Materials: A total of 18 patients, recruited into an approved study, had free-breathing and ABC breath-hold treatment plans generated. Lung volume, the percentage volume of lung treated to a dose of {>=}20 Gy (V{sub 20}), and mean lung dose (MLD) were compared. Treatment (64 Gy in 32 fractions, 5 days/week) was delivered in breath-hold. Repeat breath-hold computed tomography scans were used to assess change in gross tumor volume (GTV) size and position. Setup error was also measured and potential GTV-planning target volume (PTV) margins calculated. Results: Seventeen of 18 patients completed radiotherapy using ABC daily. Intrafraction tumor position was consistent, but interfraction variation had mean (range) values of 5.1 (0-25), 3.6 (0-9.7), and 3.5 (0-16.6) mm in the superoinferior (SI), right-left (RL), and anteroposterior (AP) directions, respectively. Tumor moved partially outside the PTV in 5 patients. Mean reduction in GTV from planning to end of treatment was 25% (p = 0.003). Potentially required PTV margins were 18.1, 11.9, and 11.9 mm in SI, RL, and AP directions. ABC reduced V{sub 20} by 13% (p = 0.0001), V{sub 13} by 12% (p = 0.001), and MLD by 13% (p < 0.001) compared with free-breathing; lung volume increased by 41% (p < 0.001). Conclusions: Clinically significant movements of GTV were seen during radiotherapy for non-small-cell lung cancer using ABC. Image guidance is recommended with ABC. The use of ABC can reduce dose volume parameters determining lung toxicity, and might allow for equitoxic radiotherapy dose escalation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Implementation of Feedback-Guided Voluntary Breath-Hold Gating for Cone Beam CT-Based Stereotactic Body Radiotherapy

Purpose: To analyze tumor position reproducibility of feedback-guided voluntary deep inspiration breath-hold (FGBH) gating for cone beam computed tomography (CBCT)-based stereotactic body radiotherapy (SBRT). Methods and materials: Thirteen early-stage lung cancer patients eligible for SBRT with tumor motion of >1cm were evaluated for FGBH-gated treatment. Multiple FGBH CTs were acquired at simulation, and single FGBH CBCTs were also acquired prior to each treatment. Simulation CTs and treatment CBCTs were analyzed to quantify reproducibility of tumor positions during FGBH. Benefits of FGBH gating compared to treatment during free breathing, as well treatment with gating at exhalation, were examined for lung sparing, motion margins, and reproducibility of gross tumor volume (GTV) position relative to nonmoving anatomy. Results: FGBH increased total lung volumes by 1.5 times compared to free breathing, resulting in a proportional drop in total lung volume receiving 10 Gy or more. Intra- and inter-FGBH reproducibility of GTV centroid positions at simulation were 1.0 {+-} 0.5 mm, 1.3 {+-} 1.0 mm, and 0.6 {+-} 0.4 mm in the anterior-posterior (AP), superior-inferior (SI), and left-right lateral (LR) directions, respectively, compared to more than 1 cm of tumor motion at free breathing. During treatment, inter-FGBH reproducibility of the GTV centroid with respect to bony anatomy was 1.2 {+-} 0.7 mm, 1.5 {+-} 0.8 mm, and 1.0 {+-} 0.4 mm in the AP, SI, and LR directions. In addition, the quality of CBCTs was improved due to elimination of motion artifacts, making this technique attractive for poorly visualized tumors, even with small motion. Conclusions: The extent of tumor motion at normal respiration does not influence the reproducibility of the tumor position under breath hold conditions. FGBH-gated SBRT with CBCT can improve the reproducibility of GTV centroids, reduce required margins, and minimize dose to normal tissues in the treatment of mobile tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prospective Study of Cone-Beam Computed Tomography Image-Guided Radiotherapy for Prone Accelerated Partial Breast Irradiation

Purpose: To report setup variations during prone accelerated partial breast irradiation (APBI). Methods: New York University (NYU) 07-582 is an institutional review board-approved protocol of cone-beam computed tomography (CBCT) to deliver image-guided ABPI in the prone position. Eligible are postmenopausal women with pT1 breast cancer excised with negative margins and no nodal involvement. A total dose of 30 Gy in five daily fractions of 6 Gy are delivered to the planning target volume (the tumor cavity with 1.5-cm margin) by image-guided radiotherapy. Patients are set up prone, on a dedicated mattress, used for both simulation and treatment. After positioning with skin marks and lasers, CBCTs are performed and the images are registered to the planning CT. The resulting shifts (setup corrections) are recorded in the three principal directions and applied. Portal images are taken for verification. If they differ from the planning digital reconstructed radiographs, the patient is reset, and a new CBCT is taken. Results: 70 consecutive patients have undergone a total of 343 CBCTs: 7 patients had four of five planned CBCTs performed. Seven CBCTs (2%) required to be repeated because of misalignment in the comparison between portal and digital reconstructed radiograph image after the first CBCT. The mean shifts and standard deviations in the anterior-posterior (AP), superior-inferior (SI), and medial-lateral (ML) directions were -0.19 (0.54), -0.02 (0.33), and -0.02 (0.43) cm, respectively. The average root mean squares of the daily shifts were 0.50 (0.28), 0.29 (0.17), and 0.38 (0.20). A conservative margin formula resulted in a recommended margin of 1.26, 0.73, 0.96 cm in the AP, SI, and ML directions. Conclusion: CBCTs confirmed that the NYU prone APBI setup and treatment technique are reproducible, with interfraction variation comparable to those reported for supine setup. The currently applied margin (1.5 cm) adequately compensates for the setup variation detected.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Setup Variations in Radiotherapy of Anal Cancer: Advantages of Target Volume Reduction Using Image-Guided Radiation Treatment

Purpose: To define setup variations in the radiation treatment (RT) of anal cancer and to report the advantages of image-guided RT (IGRT) in terms of reduction of target volume and treatment-related side effects. Methods and Materials: Twelve consecutive patients with anal cancer treated by combined chemoradiation by use of helical tomotherapy from March 2007 to November 2008 were selected. With patients immobilized and positioned in place, megavoltage computed tomography (MVCT) scans were performed before each treatment and were automatically registered to planning CT scans. Patients were shifted per the registration data and treated. A total of 365 MVCT scans were analyzed. The primary site received a median dose of 55 Gy. To evaluate the potential dosimetric advantage(s) of IGRT, cases were replanned according to Radiation Therapy Oncology Group 0529, with and without adding recommended setup variations from the current study. Results: Significant setup variations were observed throughout the course of RT. The standard deviations for systematic setup correction in the anterior-posterior (AP), lateral, and superior-inferior (SI) directions and roll rotation were 1.1, 3.6, and 3.2 mm, and 0.3 Degree-Sign , respectively. The average random setup variations were 3.8, 5.5, and 2.9 mm, and 0.5 Degree-Sign , respectively. Without daily IGRT, margins of 4.9, 11.1, and 8.5 mm in the AP, lateral, and SI directions would have been needed to ensure that the planning target volume (PTV) received {>=}95% of the prescribed dose. Conversely, daily IGRT required no extra margins on PTV and resulted in a significant reduction of V15 and V45 of intestine and V10 of pelvic bone marrow. Favorable toxicities were observed, except for acute hematologic toxicity. Conclusions: Daily MVCT scans before each treatment can effectively detect setup variations and thereby reduce PTV margins in the treatment of anal cancer. The use of concurrent chemotherapy and IGRT provided favorable toxicities, except for acute hematologic toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Is There an Advantage in Designing Adapted, Patient-Specific PTV Margins in Intensity Modulated Proton Beam Therapy for Prostate Cancer?

Purpose: To investigate robust margin strategies in intensity modulated proton therapy to account for interfractional organ motion in prostate cancer. Methods and Materials: For 9 patients, one planning computed tomography (CT) scan and daily and weekly cone beam CTs (CBCTs) were acquired and coregistered. The following planning target volume (PTV) approaches were investigated: a clinical target volume (CTV) delineated on the planning CT (CTV{sub ct}) plus 10-mm margin (PTV{sub 10mm}); a reduced PTV (PTV{sub Red}): CTV{sub ct} plus 5 mm in the left-right (LR) and anterior-posterior (AP) directions and 8 mm in the inferior-superior (IS) directions; and a PTV{sub Hull} method: the sum of CTV{sub ct} and CTVs from 5 CBCTs from the first week plus 3 mm in the LR and IS directions and 5 mm in the AP direction. For each approach, separate plans were calculated using a spot-scanning technique with 2 lateral fields. Results: Each approach achieved excellent target coverage. Differences were observed in volume receiving 98% of the prescribed dose (V{sub 98%}) where PTV{sub Hull} and PTV{sub Red} results were superior to the PTV{sub 10mm} concept. The PTV{sub Hull} approach was more robust to organ motion. The V{sub 98%} for CTVs was 99.7%, whereas for PTV{sub Red} and PTV{sub 10mm} plans, V{sub 98%} was 98% and 96.1%, respectively. Doses to organs at risk were higher for PTV{sub Hull} and PTV{sub 10mm} plans than for PTV{sub Red}, but only differences between PTV{sub 10mm} and PTV{sub Red} were significant. Conclusions: In terms of organ sparing, the PTV{sub 10mm} method was inferior but not significantly different from the PTV{sub Red} and PTV{sub Hull} approaches. PTV{sub Hull} was most insensitive to target motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prostate and Patient Intrafraction Motion: Impact on Treatment Time-Dependent Planning Margins for Patients With Endorectal Balloon

Purpose: To investigate intrafraction prostate and patient motion during different radiation therapy treatments as a function of treatment time; included were prostate patients with an endorectal balloon (ERB). Margins accounting for setup uncertainties and intrafraction motion were determined. Methods and Materials: The study included 17 patients undergoing prostate cancer radiation therapy. All patients received 3 fiducial gold markers implanted in the prostate and were then immobilized in the supine position with a knee support and treated with an ERB. Twelve patients with intermediate risk for pelvic lymph node metastases received intensity modulated radiation therapy (IMRT), and 5 patients at low risk received a 4-field box treatment. After setup based on skin marks, patients were imaged with a stereoscopic imaging system. If the marker displacement exceeded a 3-mm tolerance relative to planning computed tomography, patients were shifted and verification images were taken. All patients underwent additional imaging after treatment; IMRT patients also received additional imaging at halftime of treatment. Prostate and bone drifts were evaluated as a function of treatment time for more than 600 fractions, and margins were extracted. Results: Patient motion evaluated by bone match was strongly patient dependent but in general was smallest in the superior-inferior (SI) direction. Prostate drifts were less patient dependent, showing an increase with treatment time in the SI and anterior-posterior (AP) directions. In the lateral (LAT) direction, the prostate stayed rather stable. Mean treatment times were 5.5 minutes for 4-field box, 10 minutes for 5-field boost IMRT, and 15 minutes or more for 9-field boost and 9-field pelvic IMRT treatments. Margins resulted in 2.2 mm, 3.9 mm, and 4.3 mm for 4-field box; 3.7 mm, 2.6 mm, and 3.6 mm for 5-field boost IMRT; 2.3 mm, 3.9 mm, and 6.2 mm for 9-field boost IMRT; and 4.2 mm, 5.1 mm, and 6.6 mm for 9-field pelvic IMRT in the LAT, SI, and AP directions, respectively. Conclusion: Intrafraction prostate and patient displacement increased with treatment time, showing different behaviors for the single directions of movement. Repositioning of the patients during long treatments or shorter treatment times will be necessary to further reduce the treatment margin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Estimation of Rectal Dose Using Daily Megavoltage Cone-Beam Computed Tomography and Deformable Image Registration

Purpose: The actual dose delivered to critical organs will differ from the simulated dose because of interfractional organ motion and deformation. Here, we developed a method to estimate the rectal dose in prostate intensity modulated radiation therapy with consideration to interfractional organ motion using daily megavoltage cone-beam computed tomography (MVCBCT). Methods and Materials: Under exemption status from our institutional review board, we retrospectively reviewed 231 series of MVCBCT of 8 patients with prostate cancer. On both planning CT (pCT) and MVCBCT images, the rectal contours were delineated and the CT value within the contours was replaced by the mean CT value within the pelvis, with the addition of 100 Hounsfield units. MVCBCT images were rigidly registered to pCT and then nonrigidly registered using B-Spline deformable image registration (DIR) with Velocity AI software. The concordance between the rectal contours on MVCBCT and pCT was evaluated using the Dice similarity coefficient (DSC). The dose distributions normalized for 1 fraction were also deformed and summed to estimate the actual total dose. Results: The DSC of all treatment fractions of 8 patients was improved from 0.75±0.04 (mean ±SD) to 0.90 ±0.02 by DIR. Six patients showed a decrease of the generalized equivalent uniform dose (gEUD) from total dose compared with treatment plans. Although the rectal volume of each treatment fraction did not show any correlation with the change in gEUD (R{sup 2}=0.18±0.13), the displacement of the center of gravity of rectal contours in the anterior-posterior (AP) direction showed an intermediate relationship (R{sup 2}=0.61±0.16). Conclusion: We developed a method for evaluation of rectal dose using DIR and MVCBCT images and showed the necessity of DIR for the evaluation of total dose. Displacement of the rectum in the AP direction showed a greater effect on the change in rectal dose compared with the rectal volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Six Degrees-of-Freedom Prostate and Lung Tumor Motion Measurements Using Kilovoltage Intrafraction Monitoring

Purpose: Tumor positional uncertainty has been identified as a major issue that deteriorates the efficacy of radiation therapy. Tumor rotational movement, which is not well understood, can result in significant geometric and dosimetric inaccuracies. The objective of this study was to measure 6 degrees-of-freedom (6 DoF) prostate and lung tumor motion, focusing on the more novel rotation, using kilovoltage intrafraction monitoring (KIM). Methods and Materials: Continuous kilovoltage (kV) projections of tumors with gold fiducial markers were acquired during radiation therapy for 267 fractions from 10 prostate cancer patients and immediately before or after radiation therapy for 50 fractions from 3 lung cancer patients. The 6 DoF motion measurements were determined from the individual 3-dimensional (3D) marker positions, after using methods to reject spurious and smooth noisy data, using an iterative closest point algorithm. Results: There were large variations in the magnitude of the tumor rotation among different fractions and patients. Various rotational patterns were observed. The average prostate rotation angles around the left-right (LR), superior-inferior (SI), and anterior-posterior (AP) axes were 1.0 ± 5.0°, 0.6 ± 3.3°, and 0.3 ± 2.0°, respectively. For 35% of the time, the prostate rotated more than 5° about the LR axis, indicating the need for intrafractional adaptation during radiation delivery. For lung patients, the average LR, SI, and AP rotation angles were 0.8 ± 4.2°, −0.8 ± 4.5°, and 1.7 ± 3.1°, respectively. For about 30% of the time, the lung tumors rotated more than 5° around the SI axis. Respiration-induced rotation was detected in 2 of the 3 lung patients. Conclusions: The prostate and lung tumors were found to undergo rotations of more than 5° for about a third of the time. The lung tumor data represent the first 6 DoF tumor motion measured by kV images. The 6 DoF KIM method can enable rotational and translational adaptive radiation therapy and potentially reduce treatment margins.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Verification of Accuracy of CyberKnife Tumor-tracking Radiation Therapy Using Patient-specific Lung Phantoms

Purpose: To investigate the accuracy of the CyberKnife Xsight Lung Tracking System (XLTS) compared with that of a fiducial-based target tracking system (FTTS) using patient-specific lung phantoms. Methods and Materials: Three-dimensional printing technology was used to make individualized lung phantoms that closely mimicked the lung anatomy of actual patients. Based on planning computed tomographic data from 6 lung cancer patients who underwent stereotactic ablative radiation therapy using the CyberKnife, the volume above a certain Hounsfield unit (HU) was assigned as the structure to be filled uniformly with polylactic acid material by a 3-dimensional printer (3D Edison, Lokit, Korea). We evaluated the discrepancies between the measured and modeled target positions, representing the total tracking error, using 3 log files that were generated during each treatment for both the FTTS and the XLTS. We also analyzed the γ index between the film dose measured under the FTTS and XLTS. Results: The overall mean values and standard deviations of total tracking errors for the FTTS were 0.36 ± 0.39 mm, 0.15 ± 0.64 mm, and 0.15 ± 0.62 mm for the craniocaudal (CC), left–right (LR), and anteroposterior (AP) components, respectively. Those for the XLTS were 0.38 ± 0.54 mm, 0.13 ± 0.18 mm, and 0.14 ± 0.37 mm for the CC, LR, and AP components, respectively. The average of γ passing rates was 100% for the criteria of 3%, 3 mm; 99.6% for the criteria of 2%, 2 mm; and 86.8% for the criteria of 1%, 1 mm. Conclusions: The XLTS has segmentation accuracy comparable with that of the FTTS and small total tracking errors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Subsecond and Submillimeter Resolution Positional Verification for Stereotactic Irradiation of Spinal Lesions

Purpose: Spine stereotactic body radiation therapy (SBRT) requires highly accurate positioning. We report our experience with markerless template matching and triangulation of kilovoltage images routinely acquired during spine SBRT, to determine spine position. Methods and Materials: Kilovoltage images, continuously acquired at 7, 11 or 15 frames/s during volumetric modulated spine SBRT of 18 patients, consisting of 93 fluoroscopy datasets (1 dataset/arc), were analyzed off-line. Four patients were immobilized in a head/neck mask, 14 had no immobilization. Two-dimensional (2D) templates were created for each gantry angle from planning computed tomography data and registered to prefiltered kilovoltage images to determine 2D shifts between actual and planned spine position. Registrations were considered valid if the normalized cross correlation score was ≥0.15. Multiple registrations were triangulated to determine 3D position. For each spine position dataset, average positional offset and standard deviation were calculated. To verify the accuracy and precision of the technique, mean positional offset and standard deviation for twenty stationary phantom datasets with different baseline shifts were measured. Results: For the phantom, average standard deviations were 0.18 mm for left-right (LR), 0.17 mm for superior-inferior (SI), and 0.23 mm for the anterior-posterior (AP) direction. Maximum difference in average detected and applied shift was 0.09 mm. For the 93 clinical datasets, the percentage of valid matched frames was, on average, 90.7% (range: 49.9-96.1%) per dataset. Average standard deviations for all datasets were 0.28, 0.19, and 0.28 mm for LR, SI, and AP, respectively. Spine position offsets were, on average, −0.05 (range: −1.58 to 2.18), −0.04 (range: −3.56 to 0.82), and −0.03 mm (range: −1.16 to 1.51), respectively. Average positional deviation was <1 mm in all directions in 92% of the arcs. Conclusions: Template matching and triangulation using kilovoltage images acquired during irradiation allows spine position detection with submillimeter accuracy at subsecond intervals. Although the majority of patients were not immobilized, most vertebrae were stable at the sub-mm level during spine SBRT delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three-Dimensional Dosimetric Validation of a Magnetic Resonance Guided Intensity Modulated Radiation Therapy System

Purpose: To validate the dosimetric accuracy of a commercially available magnetic resonance guided intensity modulated radiation therapy (MRgIMRT) system using a hybrid approach: 3-dimensional (3D) measurements and Monte Carlo calculations. Methods and Materials: We used PRESAGE radiochromic plastic dosimeters with remote optical computed tomography readout to perform 3D high-resolution measurements, following a novel remote dosimetry protocol. We followed the intensity modulated radiation therapy commissioning recommendations of American Association of Physicists in Medicine Task Group 119, adapted to incorporate 3D data. Preliminary tests (“AP” and “3D-Bands”) were delivered to 9.5-cm usable diameter cylindrical PRESAGE dosimeters to validate the treatment planning system (TPS) for nonmodulated deliveries; assess the sensitivity, uniformity, and rotational symmetry of the PRESAGE dosimeters; and test the robustness of the remote dosimetry protocol. Following this, 4 clinical MRgIMRT plans (“MultiTarget,” “Prostate,” “Head/Neck,” and “C-Shape”) were measured using 13-cm usable diameter PRESAGE dosimeters. For all plans, 3D-γ (3% or 3 mm global, 10% threshold) passing rates were calculated and 3D-γ maps were examined. Point doses were measured with an IBA-CC01 ionization chamber for validation of absolute dose. Finally, by use of an in-house-developed, GPU-accelerated Monte Carlo algorithm (gPENELOPE), we independently calculated dose for all 6 Task Group 119 plans and compared against the TPS. Results: For PRESAGE measurements, 3D-γ analysis yielded passing rates of 98.7%, 99.2%, 98.5%, 98.0%, 99.2%, and 90.7% for AP, 3D-Bands, MultiTarget, Prostate, Head/Neck, and C-Shape, respectively. Ion chamber measurements were within an average of 0.5% (±1.1%) from the TPS dose. Monte Carlo calculations demonstrated good agreement with the TPS, with a mean 3D-γ passing rate of 98.5% ± 1.9% using a stricter 2%/2-mm criterion. Conclusions: We have validated the dosimetric accuracy of a commercial MRgIMRT system using high-resolution 3D techniques. We have demonstrated for the first time that hybrid 3D remote dosimetry is a comprehensive and feasible approach to commissioning MRgIMRT. This may provide better sensitivity in error detection compared with standard 2-dimensional measurements and could be used when implementing complex new magnetic resonance guided radiation therapy technologies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hydrogen activation by rhodium under the cover of a copper oxide thin film

Here, the activation of reactants by catalytically active metal sites at metal-oxide interfaces is important for understanding the effect of metal-support interactions on nanoparticle catalysts and for tuning activity and selectivity. Using a combined experimental and theoretical approach, we studied the activation of H 2 and the effect of CO poisoning on isolated Rh atoms completely or partially covered by a copper oxide (Cu 2 O) thin film. Temperature-programmed desorption (TPD) experiments conducted in ultra-high vacuum (UHV) show that neither a partially nor a fully oxidized Cu 2 O layer grown on a Rh/Cu(111) single-atom alloy can activate hydrogen in UHV. However, in situ ambient pressure X-ray photoelectron spectroscopy (AP-XPS) experiments performed at elevated H 2 pressures reveal that Rh significantly accelerates the reduction of these Cu 2 O thin films by hydrogen. Remarkably, the fastest reduction rate is observed for the fully oxidized sample with all Rh sites covered by Cu 2 O. Both TPD and AP-XPS data demonstrate that these covered Rh sites are inaccessible to CO, indicating that Rh under Cu 2 O is active for H 2 dissociation but cannot be poisoned by CO. In contrast, an incomplete oxide film leaves some of the Rh sites exposed and accessible to CO, and hence prone to CO poisoning. Density functional theory calculations demonstrate that unlike many reactions in which hydrogen activation is rate limiting, the rate-determining step in the dissociation of H 2 on thin-film Cu 2 O with Rh underneath is the adsorption of H 2 on the buried Rh site, and once adsorbed, the dissociation of H 2 is barrierless. These calculations also explain why H 2 can only be activated at higher pressures. Together, these results highlight how different the reactivity of atomically dispersed Rh in Cu can be depending on its accessibility through the oxide layer, providing a way to engineer Rh sites that are active for hydrogen activation but resilient to CO poisoning.

36 MATERIALS SCIENCE↗

Insights into the methanol synthesis mechanism via CO 2 hydrogenation over Cu-ZnO-ZrO2 catalysts: Effects of surfactant/Cu-Zn-Zr molar ratio

In this study, we evaluated aspects of the CO 2 hydrogenation mechanism, correlating structure-activity relationships of Cu-ZnO-ZrO 2 catalysts prepared by one-pot surfactant-assisted co-precipitation with different surfactant ratios. Identifying the CO 2 hydrogenation pathway intermediates is key to controlling the reaction selectivity. Experimental evidence shows that the CO 2 is dissociating into CO* and O* onto the surface of the Cu-ZnO-ZrO 2 catalyst. The adsorption and dissociation of CO2 were evidenced by a combination of in situ ambient-pressure X-ray Photoelectron Spectroscopy (AP-XPS) and Fourier Transform Infrared Spectroscopy (FTIR) with a transmission cell. AP-XPS showed that the catalysts are composed of a Cu 2+ , Zr 3+ , and Zr 4+ mixture and two kinds of Zn 2+ species. After the H 2 reduction process, only Cu 2+ was reduced to Cu0. The Zn and Zr species were oxidized by the dissociated O* species. In situ transmission FTIR showed that CO was adsorbed onto the Cu+/0 sites. The catalyst with the higher surfactant molar ratio exhibited the highest CO 2 conversion close to the equilibrium conversion, as well as a good methanol formation rate.

36 MATERIALS SCIENCE↗

On the asymptotic preserving property of the unified gas kinetic scheme for the diffusion limit of linear kinetic models

The unified gas kinetic scheme (UGKS) of K. Xu et al. (2010) [37], originally developed for multiscale gas dynamics problems, is applied in this paper to a linear kinetic model of radiative transfer theory. While such problems exhibit purely diffusive behavior in the optically thick (or small Knudsen) regime, we prove that UGKS is still asymptotic preserving (AP) in this regime, but for the free transport regime as well. Moreover, this scheme is modified to include a time implicit discretization of the limit diffusion equation, and to correctly capture the solution in case of boundary layers. Contrary to many AP schemes, this method is based on a standard finite volume approach, it does neither use any decomposition of the solution, nor staggered grids. Several numerical tests demonstrate the properties of the scheme.

97 MATHEMATICS AND COMPUTING↗

An asymptotic preserving unified gas kinetic scheme for gray radiative transfer equations

The solutions of radiative transport equations can cover both optical thin and optical thick regimes due to the large variation of photon's mean-free path and its interaction with the material. In the small mean free path limit, the nonlinear time-dependent radiative transfer equations can converge to an equilibrium diffusion equation due to the intensive interaction between radiation and material. In the optical thin limit, the photon free transport mechanism will emerge. In this paper, we are going to develop an accurate and robust asymptotic preserving unified gas kinetic scheme (AP-UGKS) for the gray radiative transfer equations, where the radiation transport equation is coupled with the material thermal energy equation. The current work is based on the UGKS framework for the rarefied gas dynamics [14], and is an extension of a recent work [12] from a one-dimensional linear radiation transport equation to a nonlinear two-dimensional gray radiative system. The newly developed scheme has the asymptotic preserving (AP) property in the optically thick regime in the capturing of diffusive solution without using a cell size being smaller than the photon's mean free path and time step being less than the photon collision time. Besides the diffusion limit, the scheme can capture the exact solution in the optical thin regime as well. The current scheme is a finite volume method. Due to the direct modeling for the time evolution solution of the interface radiative intensity, a smooth transition of the transport physics from optical thin to optical thick can be accurately recovered. Many numerical examples are included to validate the current approach.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗