At least 91 records · Page 5

Power train analysis for the DOE/NASA 100-kW wind turbine generator

Progress in explaining variations of power experienced in the on-line operation of a 100 kW experimental wind turbine-generator is reported. Data are presented that show the oscillations tend to be characteristic of a wind-driven synchronous generator because of low torsional damping in the power train, resonances of its large structure, and excitation by unsteady and nonuniform wind flow. The report includes dynamic analysis of the drive-train torsion, the generator, passive driveline damping, and active pitch control as well as correlation with experimental recordings. The analysis assumes one machine on an infinite bus with constant generator-field excitation.

Seidel, R. C.↗

Wind turbine generator interaction with diesel generators on an isolated power system

The results of a dynamic interaction investigation to characterize any disturbances caused by interfacing the Mod 0A wind turbine (150 kW configuration) with the Block Island utility diesel generator grid are reported. The tests were run when only two diesel generators were on line, and attention was given to power, frequency, and voltage time profiles. The interconnected system was examined in the start-up and synchronization phase, normal shutdown and cut-out of the wind turbine, during fixed pitch generation, and during variable pitch operation. Governors were installed on the diesel generators to accommodate the presence of wind-derived electricity. The blade pitch control was set to maintain power at 150 kW or below. Power and voltage transients were insignificant during start-up and shutdown, and frequency aberrations were within the range caused by load fluctuations. It is concluded that wind turbine generation can be successfully implemented by an isolated utility, even with a significant penetration to the total grid output.

Scott, G. W.↗

Dynamics and stability of wind turbine generators

Synchronous and induction generators are considered. A comparison is made between wind turbines, steam, and hydro units. The unusual phenomena associated with wind turbines are emphasized. The general control requirements are discussed, as well as various schemes for torsional damping such as speed sensitive stabilizer and blade pitch control. Integration between adjacent wind turbines in a wind farm is also considered.

Hinrichsen, E. N.↗

Experience and assessment of the DOE-NASA Mod-1 2000-Kilowatt wind turbine generator at Boone, North Carolina

The Mod 1 program objectives are defined. The Mod 1 wind turbine is described. In addition to the steel blade operated on the wind turbine, a composite blade was designed and manufactured. During the early phase of the manufacturing cycle of Mod 1A configuration was designed that identified concepts such as partial span control, a soft tower, and upwind teetered rotors that were incorporated in second and third generation industry designs. The Mod 1 electrical system performed as designed, with voltage flicker characteristics within acceptable utility limits. Power output versus wind speed equaled or exceeded design predictions. The wind turbine control system was operated successfully at the site and remotely from the utility dispatcher's office. During wind turbine operations, television interference was experienced by the local residents. As a consequence, operations were restricted. Although not implemented, two potential solutions were identified. In addition to television interference, a few local residents complained bout objectionable sound, particularly the 'thump' as the blade passed behind the tower. To eliminate objections, the sound generation level was reduced by 10 dB by reducing the rotor speed from 35 rpm to 23 rpm. Bolts in the drive train fractured. A solution was identified but not implemented. The public reaction toward the Mod 1 wind turbine program was overwhelmingly favorable.

Collins, J. L.↗

Sound measurements and observations of the MOD-OA wind turbine generator

Sound measurements are reported for a wind velocity of about 5 m/s and a power output of about 70 kW. Both broadband and narrowband data were obtained for a range of distances and azimuth angles from the machine. Both discrete frequency and broadband components were identified. Loading harmonics at multiples of the blade passage frequency and electrical generator harmonics at multiples of the shaft speed dominated the spectrum below 100 Hz. The 10,000 Hz peak is believed to be of mechanical origin in the nacelle and the other arises from blade aerodynamic sources. Aural detection distances of about 525 m upwind and 850 downwind were observed.

Shepherd, K. P.↗

Conceptual design of the 6 MW Mod-5A wind turbine generator

The General Electric Company, Advanced Energy Programs Department, is designing under DOE/NASA sponsorship the MOD-5A wind turbine system which must generate electricity for 3.75 cent/KWH (1980) or less. During the Conceptual Design Phase, completed in March, 1981, the MOD-5A WTG system size and features were established as a result of tradeoff and optimization studies driven by minimizing the system cost of energy (COE). This led to a 400' rotor diameter size. The MOD-5A system which resulted is defined in this paper along with the operational and environmental factors that drive various portions of the design. Development of weight and cost estimating relationships (WCER's) and their use in optimizing the MOD-5A are discussed. The results of major tradeoff studies are also presented. Subsystem COE contributions for the 100th unit are shown along with the method of computation. Detailed descriptions of the major subsystems are given, in order that the results of the various trade and optimization studies can be more readily visualized.

Barton, R. S.↗

Experience and Assessment of the DOE/NASA Mod-1 2000 Kw Wind Turbine Generator at Boone, North Carolina

The Mod 1 program objectives are defined. The Mod 1 wind turbine is described. In addition to the steel blade operated on the wind turbine, a composite blade was designed and manufactured. During the early phase of the manufacturing cycle of Mod 1A configuration was designed that identified concepts such as partial span control, a soft tower, and upwind teetered rotors that were incorporated in second and third generation industry designs. The Mod 1 electrical system performed as designed, with voltage flicker characteristics within acceptable utility limits.

Collins, J. L.↗

A 200-kW wind turbine generator conceptual design study

A conceptual design study was conducted to define a 200 kW wind turbine power system configuration for remote applications. The goal was to attain an energy cost of 1 to 2 cents per kilowatt-hour at a 14-mph site (mean average wind velocity at an altitude of 30 ft.) The costs of the Clayton, New Mexico, Mod-OA (200-kW) were used to identify the components, subsystems, and other factors that were high in cost and thus candidates for cost reduction. Efforts devoted to developing component and subsystem concepts and ideas resulted in a machine concept that is considerably simpler, lighter in weight, and lower in cost than the present Mod-OA wind turbines. In this report are described the various innovations that contributed to the lower cost and lighter weight design as well as the method used to calculate the cost of energy.

Source record↗

Control of wind turbine generators connected to power systems

A unique simulation model based on a Mode-O wind turbine is developed for simulating both speed and power control. An analytical representation for a wind turbine that employs blade pitch angle feedback control is presented, and a mathematical model is formulated. For Mode-O serving as a practical case study, results of a computer simulation of the model as applied to the problems of synchronization and dynamic stability are provided. It is shown that the speed and output of a wind turbine can be satisfactorily controlled within reasonable limits by employing the existing blade pitch control system under specified conditions. For power control, an additional excitation control is required so that the terminal voltage, output power factor, and armature current can be held within narrow limits. As a result, the variation of torque angle is limited even if speed control is not implemented simultaneously with power control. Design features of the ERDA/NASA 100-kW Mode-O wind turbine are included.

Hwang, H. H.↗

MOD-OA 200 kW wind turbine generator engineeringing

Engineering drawings and the detailed mechanical and electrical design of a horizontal-axis wind turbine designed for DOE at the NASA Lewis Research Center and installed in Clayton, New Mexico are discussed. The drawings show the hub, pitch change mechanism, drive train, nacelle equipment, yaw drive system, tower, foundation, electrical power systems, and the control and safety systems.

Andersen, T. S.↗

Environmental noise characteristics of the MOD5-B (3.2 MW) wind turbine generator

Both narrow band and broad band acoustic data were obtained for the MOD5-B wind turbine for a range of wind speeds from 5.8 to 14.3 m/s; for a range of power outputs from 300 to 3100 kW; and for various azimuth angles and distances. Comparisons are made with those of other large machines and with predictions by available methods. The highest levels occur at the lower frequencies and generally decrease as the frequency increases. Low frequency rotational noise components were more intense than expected for an upwind machine and are believed to result from localized wind gradients across the rotor disk due to upwind terrain features. Predicted broad band spectra follow the general trends of the data but tend to underestimate the levels in the frequency range where the turbulent boundary layer-trailing edge interaction noise is expected to be significant.

Shepherd, Kevin P.↗

Wind turbine generator interaction with conventional diesel generators on Block Island, Rhode Island. Volume 2: Data analysis

Assessing the performance of a MOD-OA horizontal axis wind turbine connected to an isolated diesel utility, a comprehensive data measurement program was conducted on the Block Island Power Company installation on Block Island, Rhode Island. The detailed results of that program focusing on three principal areas of (1) fuel displacement (savings), (2) dynamic interaction between the diesel utility and the wind turbine, (3) effects of three models of wind turbine reactive power control are presented. The approximate two month duration of the data acquisition program conducted in the winter months (February into April 1982) revealed performance during periods of highest wind energy penetration and hence severity of operation. Even under such conditions fuel savings were significant resulting in a fuel reduction of 6.7% while the MOD-OA was generating 10.7% of the total electrical energy. Also, electrical disturbance and interactive effects were of an acceptable level.

Wilreker, V. F.↗

Performance and load data from Mod-0A and Mod-1 wind turbine generators

Experimental data, together with supporting analysis, are presented on the power conversion performance and blade loading of large, horizontal-axis wind turbines tested at electric utility sites in the U.S. Four turbine rotor configurations, from 28 to 61 meters in diameter, and data from five test sites are included. Performance data are presented in the form of graphs of power and system efficiency versus free-stream wind speed. Deviations from theoretical performance are analyzed statistically. Power conversion efficiency averaged 0.34 for all tests combined, compared with 0.31 predicted. Round blade tips appeared to improve performance significantly. Cyclic blade loads were normalized to develop load factors which can be used in the design of rotors with rigid hubs.

Spera, D. A.↗

Noise radiation characteristics of the Westinghouse WWG-0600 (600kW) wind turbine generator

Acoustic data are presented from five different WWG-0600 machines for the wind speed range 6.7 to 13.4 m/s, for a power output range of 51 to 600 kW and for upwind, downwind and crosswind locations. Both broadband and narrowband data are presented and are compared with calculations and with similar data from other machines. Predicted broadband spectra are in good agreement with measurements at high power and underestimate them at low power. Discrete frequency rotational noise components are present in all measurements and are believed due to terrain induced wind gradients. Predictions are in general agreement with measurements upwind and downwind but underestimate them in the crosswind direction.

Shepherd, Kevin P.↗

Evaluation of human exposure to the noise from large wind turbine generators

The human perception of a nuisance level of noise was quantified in tests and attempts were made to define criteria for acceptable sound levels from wind turbines. Comparisons were made between the sound necessary to cause building vibration, which occurred near the Mod-1 wind turbine, and human perception thresholds for building noise and building vibration. Thresholds were measured for both broadband and impulsive noise, with the finding that noise in the 500-2000 Hz region, and impulses with a 1 Hz fundamental, were most noticeable. Curves were developed for matching a receiver location with expected acoustic output from a machine to determine if the sound levels were offensive. In any case, further data from operating machines are required before definitive criteria can be established.

Shepherd, K. P.↗

Design evolution of large wind turbine generators

During the past five years, the goals of economy and reliability have led to a significant evolution in the basic design--both external and internal--of large wind turbine systems. To show the scope and nature of recent changes in wind turbine designs, development of three types are described: (1) system configuration developments; (2) computer code developments; and (3) blade technology developments.

Spera, D. A.↗

Fiberglass composite blades for the 2 MW Mod-1 wind turbine generator

In mid-1979, NASA contracted with Kaman Aerospace Corporation for the design, manufacture, and ground testing of two 100 foot composite rotor blades intended for operation on the Mod-1 wind turbine. The Mod-1 blades have been completed and are currently stored at the Kaman facility. The design, tooling, fabrication, and testing phases which have been carried out to date, as well as testing still planned are described. Discussed are differences from the 150 foot blade which were introduced for cost and manufacturing improvement purposes. Also included is a description of the lightning protection system installed in the blades, and its development program. Actual costs and manhours expended for Blade No. 2 are provided as a base, along with a projection of costs for the blade in production. Finally, cost drivers are identified relative to future designs.

Batesole, W. R.↗

Wind turbine generator rotor blade concepts with low cost potential

Four processed for producing blades are examined. Two use filament winding techniques and two involve filling a mold or form to produce all or part of a blade. The processes are described and a comparison is made of cost, material properties, design and free vibration characteristics. Conclusions are made regarding the feasibility of each process to produce low cost, structurally adequate blades.

Sullivan, T. L.↗