Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “wind based electricity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Small Wind Electric Systems: A Missouri Consumer's Guide

This guide provides consumers with information to help them determine whether a small wind electric system can provide all or a portion of the energy they need for their home or business based on their wind resource, energy needs, and economics.

distributed wind↗

Small Wind Electric Systems: A Nebraska Consumer's Guide

This guide provides consumers with information to help them determine whether a small wind electric system can provide all or a portion of the energy they need for their home or business based on their wind resource, energy needs, and economics.

distributed wind↗

Small Wind Electric Systems: A Nevada Consumer's Guide

This guide provides consumers with information to help them determine whether a small wind electric system can provide all or a portion of the energy they need for their home or business based on their wind resource, energy needs, and economics.

distributed wind↗

Small Wind Electric Systems: A Utah Consumer's Guide

This guide provides consumers with information to help them determine whether a small wind electric system can provide all or a portion of the energy they need for their home or business based on their wind resource, energy needs, and economics.

distributed wind↗

Small Wind Electric Systems: An Indiana Consumer's Guide

This guide provides consumers with information to help them determine whether a small wind electric system can provide all or a portion of the energy they need for their home or business based on their wind resource, energy needs, and economics.

distributed wind↗

Small Wind Electric Systems: An Oklahoma Consumer's Guide

This guide provides consumers with information to help them determine whether a small wind electric system can provide all or a portion of the energy they need for their home or business based on their wind resource, energy needs, and economics.

distributed wind↗

Pricing Strategy of Electric Vehicle Aggregators Based on Locational Marginal Price to Minimize Photovoltaic (PV) Curtailment

The global climate crisis demands urgent action to mitigate global warming. Using renewable energy sources, such as solar and wind power, for electricity generation is crucial. This shift from centralized to distributed power systems, however, brings challenges, including voltage fluctuations and renewable energy curtailment. The rapid growth of the electric vehicle (EV) industry adds complexity, increasing overall electricity demand and straining the power supply during peak charging times. This paper proposes a scheduling strategy for EV aggregators to reduce renewable energy curtailment and stabilize grid operation by strategically scheduling EV charging. Using Multi -Agent Transport Simulation (MATSim), a traffic simulation tool, EV driving data in Denver, Colorado, USA, were modeled. The EV aggregator adjusts charging fees based on locational marginal prices, encouraging EVs to charge at different stations according to pricing. Simulations on an IEEE 33-bus system with distributed energy resources and EV charging stations validate the proposed algorithm, demonstrating its effectiveness in reducing curtailment by 12.55% and stabilizing grid operation.

33 ADVANCED PROPULSION SYSTEMS↗

Heat Storage Options for Sodium, Salt and Helium Cooled Reactors to Enable Variable Electricity to the Grid and Heat to Industry with Base-Load Reactor Operations

Electricity markets are changing rapidly because of (1) the addition of wind and solar and (2) the goal of a low-carbon electricity grid. These changes result in times of high electricity prices and very low or negative electricity prices. California has seen its first month where more than 20% of the time (mid-day) the wholesale price of electricity was zero or negative. This creates large incentives for coupling heat storage to advanced reactors to enable variable electricity and industrial-heat output (to maximize revenue) while the reactor operates at base load (minimize cost). Recent studies have examined coupling various types of heat storage to Rankine and Brayton power cycles. However, there has been little examination of heat-storage options between (1) the reactor and (2) the power-conversion system or industrial customer. Heat-storage systems can be incorporated into sodium , helium-, and salt-cooled reactors. Salt-cooled reactors include the fluoride-salt-cooled high-temperature reactor (FHR) with its solid fuel and clean coolant and the molten salt reactor (MSR) with its fuel dissolved in the salt. For sodium and salt reactors, it is assumed that a heat-storage system would be in the secondary loop between the reactor and power cycle. For helium-cooled reactors, heat storage can be in the primary or secondary loop. This report is a first look at the rational and the heat storage options for deploying gigawatt-watt hour heat-storage systems with GenIV reactors. Economics and safety are the primary selection criteria. The leading heat-storage candidate for sodium-cooled systems (a low-pressure secondary system with small temperature drop across the reactor core) is sodium coolant stored in large steel tanks, with the coolant transferring heat in channels. The design minimizes sodium volume in the storage and, thus, the risks and costs associated with sodium. For helium systems (high-pressure with large temperature drop across the core), the leading heat storage options are (1) varying the temperature of the reactor core, (2) steel or alumina firebrick in a secondary pressure vessel and (3) nitrate or hot-rock/firebrick at atmospheric pressure. For salt systems (low pressure, high temperatures, and small temperature drop across the reactor core) the leading heat-storage systems are secondary salts. In each case, options are identified and questions to be addressed are identified. In some cases there is a strong coupling between the heat-storage technology and the power cycle. The leading sodium heat-storage technology may imply changes in the power cycle. High-temperature salt systems couple efficiency to Brayton power cycles that may create large incentives for the heat storage to remain within the power cycle rather than in any intermediate heat transfer loop.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Co-optimized trading of hybrid wind power plant with retired EV batteries in energy and reserve markets under uncertainties

To be competitive in the electricity markets, various technologies have been reported to increase profits of wind farm owners. Combining battery storage system, wind farms can be operated as conventional power plants which promotes the integration of wind power into the power grid. However, high expenses on batteries keep investors away. Retired EV batteries, fortunately, still have enough capacity to be reused and could be obtained at a low price. In this work, a two-stage optimization of a wind energy retired EV battery-storage system is proposed. The economic performance of the proposed system is examined concerning its participation in the frequency containment normal operation reserve (FCR-N) market and the spot market simultaneously. To account uncertainties in the wind farm output, various electricity market prices, and up/down regulation status, a scenario-based stochastic programming method is used. The sizing of the equipment is optimized on top of daily operations of the hybrid system which formulates a mixed-integer linear programming (MILP) problem. Scenarios are generated with the Monte Carlo simulation (MCS) and Roulette Wheel Mechanism (RWM), which are further reduced with the simultaneous backward method (SBM) to increase computational efficiency. A 21 MW wind farm is selected as a case study. Here, the optimization results show that by integrating with a retired EV battery-storage system (RESS) and a bi-directional inverter, the wind farm can increase its profits significantly when forwarding bids in both of the aforementioned electricity markets.

17 WIND ENERGY↗

Thermal Energy Storage Configurations for Small Modular Reactor Load Shedding

The increased penetration of intermittent renewable energy technologies such as wind and solar power can strain electric grids, forcing carbon-based and nuclear sources of energy to operate in a load follow mode. For nuclear reactors, load follow operation can be undesirable due to the associated thermal and mechanical stresses placed on the fuel and other reactor components. Various methods of Thermal Energy Storage (TES) can be coupled to nuclear (or renewable) power sources to help absorb grid variability caused by daily load demand changes and renewable intermittency. Two TES techniques are investigated as candidate thermal reservoirs to be used in conjunction with a Small Modular Reactor (SMR): a two-tank sensible heat storage system and a stratified chilled-water storage system. The goal when coupling the two systems to the SMR is to match turbine output and demand and bypass steam to the TES systems to maintain reactor power at approximately 100%. Simulations of IPWR dynamics are run in a high-fidelity FORTRAN model developed at NCSU. Both TES systems are developed as callable FORTRAN subroutines to model the time-varying behavior associated with different configurations of these systems when connected to the SMR simulator. Simulation results reveal the sensible heat storage system is capable of meeting turbine demand and maintaining reactor power constant, while providing enough steam to power four absorption chillers for chilled-water production and storage. Here,the stored chilled water is used to supplement cooling loads of an adjacent facility.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Prediction and Control of Atomic Ordering in Electrodeposited Binary Alloy Films: Direct Synthesis of L10 Magnetic Phases

Permanent magnet materials are essential components in renewable energy technology, underlying, electric vehicles, hybrids, wind turbines and more. Today commercial permanent magnets based on Nd-Fe-B exhibit an energy product of ~ 400 kJ/m 3 , capable to run wind turbines efficiently. Unfortunately, the supplies of rare-earth elements are centralized, and their availability may see volatility over time. This state of affairs stimulates the search for the search for rare-earth-free permanent magnetic materials. The L1 0 crystal structure underlines an important class of chemical ordered alloys that exhibit uniaxial magnetocrystalline anisotropy. This material has been considered an excellent candidate for rare-earth-free permanent magnets. In this program, a series of systematic experiments were performed and analysed in order to understand the effect of each. In order to synthesize L 10-Fe-Ni, one has to circumvent the sluggish kinetic and the limited driving force resulted from the low order-disorder temperature (~320°C) of the system. A strategy was found to trigger a martensitic transformation from the FCC phase to one of the non-cubic phases by high-strain methods. The body-centered tetragonal Fe-Ni obtained by this strategy was considered as a precursor of L10 Fe-Ni. The formation of BCT Fe-Ni via a displacive process was also implemented at the nanoscale by using tailored AuNi@FeNi core@shell.

36 MATERIALS SCIENCE↗

A High-Performance Rechargeable Iron Electrode for Large-Scale Battery-Based Energy Storage

Inexpensive, robust and efficient large-scale electrical energy storage systems are vital to the utilization of electricity generated from solar and wind resources. In this regard, the low cost, robustness, and eco-friendliness of aqueous iron-based rechargeable batteries are particularly attractive and compelling. However, wasteful evolution of hydrogen during charging and the inability to discharge at high rates have limited the deployment of iron-based aqueous batteries. We report here new chemical formulations of the rechargeable iron battery electrode to achieve a ten-fold reduction in the hydrogen evolution rate, an unprecedented charging efficiency of 96%, a high specific capacity of 0.3 Ah/g, and a twenty-fold increase in discharge rate capability. We show that modifying high-purity carbonyl iron by in situ electro-deposition of bismuth leads to substantial inhibition of the kinetics of the hydrogen evolution reaction. The in situ formation of conductive iron sulfides mitigates the passivation by iron hydroxide thereby allowing high discharge rates and high specific capacity to be simultaneously achieved. These major performance improvements are crucial to advancing the prospect of a sustainable large-scale energy storage solution based on aqueous iron-based rechargeable batteries. (C) 2012 The Electrochemical Society. [DOI: 10.1149/2.034208jes] All rights reserved.

Manohar, AK↗

A database of hourly wind speed and modeled generation for US wind plants based on three meteorological models

Abstract In 2022, wind generation accounted for ~10% of total electricity generation in the United States. As wind energy accounts for a greater portion of total energy, understanding geographic and temporal variation in wind generation is key to many planning, operational, and research questions. However, in-situ observations of wind speed are expensive to make and rarely shared publicly. Meteorological models are commonly used to estimate wind speeds, but vary in quality and are often challenging to access and interpret. The Plant-Level US multi-model WIND and generation (PLUSWIND) data repository helps to address these challenges. PLUSWIND provides wind speeds and estimated generation on an hourly basis at almost all wind plants across the contiguous United States from 2018–2021. The repository contains wind speeds and generation based on three different meteorological models: ERA5, MERRA2, and HRRR. Data are publicly accessible in simple csv files. Modeled generation is compared to regional and plant records, which highlights model biases and errors and how they differ by model, across regions, and across time frames.

17 WIND ENERGY↗

The Value of Wind Technology Innovation: Implications for the U.S. Power System, Wind Industry, Electricity Consumers, and Environment

Improvements to wind technologies have, in part, led to substantial deployment of U.S. wind power in recent years. The degree to which technology innovation will continue is highly uncertain adding to uncertainties in future wind deployment. We apply electric sector modeling to estimate the potential wind deployment opportunities across a range of technology advancement projections. The suite of projections considered span a wide range of possible cost and technology innovation trajectories, including those from a recent expert elicitation of wind energy experts, a projection based on the broader literature, and one reflecting estimates based on a U.S. DOE research initiative. In addition, we explore how these deployment pathways may impact the electricity system, electricity consumers, the environment, and the wind-related workforce. Overall, our analysis finds that wind technology innovation can have consequential implications for future wind power development throughout the United States, impact the broader electricity system, lower electric system and consumer costs, provide potential environmental benefits, and grow the U.S. wind workforce.

17 WIND ENERGY↗

Timing Value of Marine Renewable Energy Resources for Potential Grid Applications

In this paper, the applicability of marine renewable energy for potential grid applications is presented. We show that many of the unique value streams from marine-based electricity generation stem from their inherent temporal characteristics, especially when compared to wind and solar. Specifically, in this work, we evaluate the timing value for three types of marine energy resources - (a) tidal (b) wave and (c) ocean currents. Firstly, through a suite of novel metrics such as resource availability, persistence and versatility, we evaluate the temporal value characteristics of these resources. Secondly, through a more grid-oriented numerical study, we comment on the potential ramifications of those temporal characteristics in context of energy balancing and effective load carrying capability, for one marine-based resource i.e. wave. Subsequently, we further our understanding of the relative advantages which may be leveraged by operating wave-based generation resources in tandem with more established renewable choices, such as solar and wind. Our results indicate that compared to wind and solar, marine energy resources are consistently more available and persistent on an hourly level, throughout an entire year of operation. In addition to this, wave resources are also seen to reduce both the magnitudes and the degree of volatility in balancing requirements within the power system. Our work not only focuses on sites specific to the Unites States (US), but also includes a parallel study for a location in Great Britain (GB). Results are found to be consistent for sites in both the US and GB, implying that the grid benefits discussed in this work could apply to a number of locations globally.

Bhattacharya, Saptarshi↗

Remote Monitoring and Diagnostics of Pitch-Bearing Defects in an MW-Scale Wind Turbine Using Pitch Symmetrical-Component Analysis

Recently, multiple wind turbine failure databases have reviewed that the pitch system is one of the subassemblies with the highest failure rates and largest contributors to the overall downtime. Therefore, there has been an increasing interest to provide remote health monitoring for wind turbine pitch system. While most of the research articles are discussing pitch actuation system (hydraulic or electric actuator) faults only, there is very limited research on pitch-bearing-defect detection. This article provides a remote and hardware-free solution to monitor multiaxis pitch-bearing health condition called pitch symmetrical-component analysis. It leverages readily available low-resolution (100 Hz) electrical measurements, mechanical measurements, and control signals from the existing pitch control platform, and innovatively applies symmetrical-component analysis in multiphase ac system to multiaxis pitch control system and introduces multiaxis pitch-bearing degradation trending curves. This hardware-free solution can be directly applied to the existing wind turbines and successfully give the wind farm operator an early warning before multiaxis pitch bearing fails. It has been proved to be accurate, low cost, and has minimum impacts on turbine normal operation, and has been validated by field data from several North America MW-scale wind farms. This approach turns out to be the first hardware-free (no additional hardware needed) method to remotely monitor and diagnose multiaxis wind turbine pitch-bearing condition.

17 WIND ENERGY↗

Wind Turbine Sound Setbacks and Supply Curves: Ordinances and Extrapolated Trends, 110 Hub Height, 130 Rotor Diameter

This dataset provides a comprehensive set of wind turbine sound setbacks from every residential structure in the contiguous United States (CONUS). A sound setback is defined as the minimum required distance between a residential structure and a hypothetical turbine installation site to ensure that modeled sound levels received at the residence do not exceed local sound ordinances, which are commonly expressed in A-weighted decibels (dBA). Therefore, sound setbacks are a local spatial assessment combining multiple factors, including the sound pressure curve as a function of the observer location (distance and direction) relative to the turbine, local sound regulations, and the geographical distribution of residential structures. The dataset is organized into multiple scenario-based products, detailed as follows: 1. Existing and extrapolated sound setbacks. An existing scenario characterizes sound setbacks only in states or counties that have implemented sound regulations as of 2022. The extrapolated scenarios extend a constant sound threshold to counties that lack explicit sound regulations, with thresholds ranging from 35 to 60 dBA, in 5-dBA increments reflecting the variation observed in current sound ordinances. 2. Sound setbacks in directional and worst scenarios. The directional scenario accounts for the distance and orientation of residential structures relative to a hypothetical turbine location, utilizing the turbine's sound emissions in that specific direction. In contrast, the worst scenario takes loudest sound level at each distance step from the turbine, irrespective of directional considerations, which aligns with current industry practice. 3. Supply curves for Open and Reference Access scenarios. This dataset includes supply curves generated by the reV model, which integrates each of the above sound setbacks into both Open and Reference siting scenarios. In addition, two Open and Reference baselines scenarios were included which do not consider sound setbacks for comparative analysis. All sound setback data are stored in TIF files, with partial maps of the data provided in PNG format. The values in the sound setback raster range from 0 to 1, representing the fraction of developable land within a 90 meter by 90 meter pixel due to sound ordinances. A value of 0 indicates areas where wind energy development is prohibited, while a value of 1 signifies areas fully permissible. The wind turbine parameters used in the sound modeling are based on the land-based turbine from International Energy Agency (IEA), featuring a rated electrical power of 3.4 MW, a rotor diameter of 130 meters, and a hub height of 110 meters. The atmospheric conditions, including wind speed/direction, turbulence, air temperature, relative humidity, and air pressure, that drive the sound generation are obtained from the WIND Toolkit dataset.

Array↗