At least 91 records · Page 5

There and Back Again: Reimagining Cryogenic Cooling for Scalable Arrays of Dilution Refrigerators for future Quantum Datacenters

While pulse tube cryocoolers enabled the rapid expansion of dilution refrigerator technology over the past two decades, the transition to large-scale quantum systems is now driving a reassessment of the DR’s higher-temperature-stage cooling strategies and how these systems can be effectively scaled in a modular way. Quasi-wet architectures based on centralized cryoplants and forced-flow helium distribution offer compelling advantages in energy efficiency, operational cost, and scalability. With appropriate redundancy, standardized interfaces, and optimized distribution system designs, these architectures will provide a practical and robust path forward for the next generation of quantum computing infrastructure.

Hansen, B. [Fermilab]↗

Heat Transfer and Pressure Loss of Additively Manufactured Internal Cooling Channels With Various Shapes

Abstract Additive manufacturing (AM) provides the ability to fabricate highly customized internal cooling passages that are relevant to gas turbine components. This experimental study examines the pressure loss and heat transfer performance of a range of fundamental channel shapes that were produced using direct metal laser sintering. Circular, hexagonal, pentagonal, elliptical, diamond, square, rectangular, trapezoidal, and triangular channel cross sections were investigated. To maintain the same convective surface area between shapes, the wetted perimeters of the channel cross sections were kept constant. Parallel computational fluid dynamic simulations were performed to understand the relationships in cooling performance between several channel shapes. Several characteristic length scales were evaluated to scale the pressure loss and heat transfer measurements. Among the channel shapes investigated, the diamond channel showed the lowest Nusselt number and friction factor. The pentagon exhibited a similar Nusselt number as the circular channel despite having a lower friction factor. There was no difference in scaling the friction factor or Nusselt number results of the different channel shapes between using the square root of cross-sectional area compared to hydraulic diameter as the characteristic length scale

Engineering↗

An Experimental and Mathematical Study to Evaluate the Role of Ultrasonic Energy in Promoting Microstructural Uniformity During Controlled Directional Solidification Processing

There are many commercially relevant metal and non-metal "alloy" systems that separate into two different liquids upon cooling from a higher temperature. Consequently during solidification processing the inherent density differences between the two liquid phases leads to rapid, gravity driven, separation and severe segregation, a factor that significantly compromises the desired material properties. Processing in a microgravity environment minimizes settling but segregation still occurs due to gravity independent wetting and coalescence phenomena. This presentation reports on experiments that utilized succinonitrile-glycerol mixtures, a transparent system that 1) separates into two liquids upon cooling and 2) is also well established as an analogue to solidification phenomena observed in metals. Segregation was significantly reduced when the mixtures were subjected to ultrasonic energy during directional solidification processing. The processing parameters introduced by this application have been evaluated in view of optimizing dispersion uniformity. The improvement is in good agreement with a novel model that 1) predicts the achievable size of the droplets as a function of applied ultrasonic energy and then 2) calculates their relative sinking velocity through the bulk liquid.

Grugel, R. N.↗

Metal foam heat exchangers for air and gas cooling and heating applications

Improved heat exchangers according to several embodiments are provided. The heat exchangers provide improved heat transfer for air flow in wet and dry operating conditions, while minimizing pressure drop across the heat exchanger in some applications. According to one embodiment, an improved heat exchanger includes a plurality of metal foam fins between adjacent heat exchange conduits, the heat exchange conduits being arranged parallel to each other to define parallel flow paths between an inlet header and an outlet header. The metal foam fins occupy a cross-flow region between adjacent conduits, the fins having a fixed angular orientation or being rotatable in unison to vary the thermal capacitance of the heat exchanger.

Nawaz, Kashif↗

Surface effects on phase distributions of a fast-quenched miscibility gap type system - Succinonitrile-water

If a binary homogeneous melt is cooled into an immiscible region, the newly formed second phase will generally have a density different from the parent phase, and will separate readily by sedimentation. Observation of solidification processes in microgravity indicates that outside of sedimentation, at least two other important effets can separate the phases: (1) preferential wetting, and (2) thermal migration of second-phase droplets due to interfacial tension gradients. The latter effect would drive the minority phase along the thermal gradient toward the hottest part (assuming the interfacial tension decreases with increasing temperature), which is usually away from the crucible wall. On the other hand, if the minority phase preferentially wets the crucible, a minority phase layer which thickens as initial solution compositions approach critical, will form adjacent to the solid surface and remain in the coldest region of the ingot. This study presents compelling preliminary evidence that these two effects do exist and that they compete with one another. However, the temperature dependence of preferential wetting below T(c) for the current system of study is, as yet, undetermined. These effects are sensitive to the initial concentration of a hypermonotectic solution cooling through a miscibility gap.

Frazier, D. O.↗

The Impact of Storms on Legionella pneumophila in Cooling Tower Water, Implications for Human Health

At the U.S. Department of Energy’s Savannah River Site (SRS) in Aiken, SC, cooling tower water is routinely monitored for Legionella pneumophila concentrations using a direct fluorescent antibody (DFA) technique. Historically, 25–30 operating SRS cooling towers have varying concentrations of Legionella in all seasons of the year, with patterns that are unpredictable. Legionellosis, or Legionnaires’ disease (LD), is a pneumonia caused by Legionella bacteria that thrive both in man-made water distribution systems and natural surface waters including lakes, streams, and wet soil. Legionnaires’ disease is typically contracted by inhaling L. pneumophila , most often in aerosolized mists that contain the bacteria. At the SRS, L. pneumophila is typically found in cooling towers ranging from non-detectable up to 10 8 cells/L in cooling tower water systems. Extreme weather conditions contributed to elevations in L. pneumophila to 10 7 –10 8 cells/L in SRS cooling tower water systems in July–August 2017. L. pneumophila concentrations in Cooling Tower 785-A/2A located in SRS A-Area, stayed in the 10 8 cells/L range despite biocide addition. During this time, other SRS cooling towers did not demonstrate this L. pneumophila increase. No significant difference was observed in the mean L. pneumophila mean concentrations for the towers ( p < 0.05). There was a significant variance observed in the 285-2A/A Tower L. pneumophila results ( p < 0.05). Looking to see if we could find “effects” led to model development by analyzing 13 months of water chemistry and microbial data for the main factors influencing the L. pneumophila concentrations in five cooling towers for this year. It indicated chlorine and dissolved oxygen had a significant impact ( p < 0.0002) on cooling tower 785A/2A. Thus, while the variation in the log count data for the A-area tower is statistically greater than that of the other four towers, the average of the log count data for the A-Area tower was in line with that of the other towers. It was also observed that the location of 785A/2A and basin resulted in more debris entering the system during storm events. Our results suggest that future analyses should evaluate the impact of environmental conditions and cooling tower design on L. pneumophila water concentrations and human health.

54 ENVIRONMENTAL SCIENCES↗

Phase change thermal control materials, method and apparatus

An apparatus and method for metabolic cooling and insulation of a user in a cold environment. In its preferred embodiment the apparatus is a highly flexible composite material having a flexible matrix containing a phase change thermal storage material. The apparatus can be made to heat or cool the body or to act as a thermal buffer to protect the wearer from changing environmental conditions. The apparatus may also include an external thermal insulation layer and/or an internal thermal control layer to regulate the rate of heat exchange between the composite and the skin of the wearer. Other embodiments of the apparatus also provide 1) a path for evaporation or direct absorption of perspiration from the skin of the wearer for improved comfort and thermal control, 2) heat conductive pathways within the material for thermal equalization, 3) surface treatments for improved absorption or rejection of heat by the material, and 4) means for quickly regenerating the thermal storage capacity for reuse of the material. Applications of the composite materials are also described which take advantage of the composite's thermal characteristics. The examples described include a diver's wet suit, ski boot liners, thermal socks, gloves and a face mask for cold weather activities, and a metabolic heating or cooling blanket useful for treating hypothermia or fever patients in a medical setting and therapeutic heating or cooling orthopedic joint supports.

Buckley, Theresa M.↗

Phase change material thermal capacitor clothing

An apparatus and method for metabolic cooling and insulation of a user in a cold environment. In its preferred embodiment the apparatus is a highly flexible composite material having a flexible matrix containing a phase change thermal storage material. The apparatus can be made to heat or cool the body or to act as a thermal buffer to protect the wearer from changing environmental conditions. The apparatus may also include an external thermal insulation layer and/or an internal thermal control layer to regulate the rate of heat exchange between the composite and the skin of the wearer. Other embodiments of the apparatus also provide 1) a path for evaporation or direct absorption of perspiration from the skin of the wearer for improved comfort and thermal control, 2) heat conductive pathways within the material for thermal equalization, 3) surface treatments for improved absorption or rejection of heat by the material, and 4) means for quickly regenerating the thermal storage capacity for reuse of the material. Applications of the composite materials are also described which take advantage of the composite's thermal characteristics. The examples described include a diver's wet suit, ski boot liners, thermal socks, gloves and a face mask for cold weather activities, and a metabolic heating or cooling blanket useful for treating hypothermia or fever patients in a medical setting and therapeutic heating or cooling orthopedic joint supports.

Buckley, Theresa M.↗

Flexible composite material with phase change thermal storage

A highly flexible composite material having a flexible matrix containing a phase change thermal storage material. The composite material can be made to heat or cool the body or to act as a thermal buffer to protect the wearer from changing environmental conditions. The composite may also include an external thermal insulation layer and/or an internal thermal control layer to regulate the rate of heat exchange between the composite and the skin of the wearer. Other embodiments of the PCM composite also provide 1) a path for evaporation or direct absorption of perspiration from the skin of the wearer for improved comfort and thermal control, 2) heat conductive pathways within the material for thermal equalization, 3) surface treatments for improved absorption or rejection of heat by the material, and 4) means for quickly regenerating the thermal storage capacity for reuse of the material. Applications of the composite materials are also described which take advantage of the composite's thermal characteristics. The examples described include a diver's wet suit, ski boot liners, thermal socks, gloves and a face mask for cold weather activities, and a metabolic heating or cooling blanket useful for treating hypothermia or fever patients in a medical setting and therapeutic heating or cooling orthopedic joint supports.

Buckley, Theresa M.↗

Flexible composite material with phase change thermal storage

A highly flexible composite material having a flexible matrix containing a phase change thermal storage material. The composite material can be made to heat or cool the body or to act as a thermal buffer to protect the wearer from changing environmental conditions. The composite may also include an external thermal insulation layer and/or an internal thermal control layer to regulate the rate of heat exchange between the composite and the skin of the wearer. Other embodiments of the PCM composite also provide 1) a path for evaporation or direct absorption of perspiration from the skin of the wearer for improved comfort and thermal control, 2) heat conductive pathways within the material for thermal equalization, 3) surface treatments for improved absorption or rejection of heat by the material, and 4) means for quickly regenerating the thermal storage capacity for reuse of the material. Applications of the composite materials are also described which take advantage of the composite's thermal characteristics. The examples described include a diver's wet suit, ski boot liners, thermal socks, ,gloves and a face mask for cold weather activities, and a metabolic heating or cooling blanket useful for treating hypothermia or fever patients in a medical setting and therapeutic heating or cooling orthopedic joint supports.

Buckley, Theresa M.↗

Method for forming hermetic seals

The firmly adherent film of bondable metal, such as silver, is applied to the surface of glass or other substrate by decomposing a layer of solution of a thermally decomposable metallo-organic deposition (MOD) compound such as silver neodecanoate in xylene. The MOD compound thermally decomposes into metal and gaseous by-products. Sealing is accomplished by depositing a layer of bonding metal, such as solder or a brazing alloy, on the metal film and then forming an assembly with another high melting point metal surface such as a layer of Kovar. When the assembly is heated above the temperature of the solder, the solder flows, wets the adjacent surfaces and forms a hermetic seal between the metal film and metal surface when the assembly cools.

Gallagher, Brian D.↗

Distinct Influences of Land Cover and Land Management on Seasonal Climate

Anthropogenic land use and land cover change is primarily represented in climate model simulations through prescribed transitions from natural vegetation to cropland or pasture. However, recent studies have demonstrated that land management practices, especially irrigation, have distinct climate impacts. Here we disentangle the seasonal climate impacts of land cover change and irrigation across areas of high agricultural intensity using climate simulations with three different land surface scenarios: (1) natural vegetation cover/no irrigation, (2) year 2000 crop cover/no irrigation, and (3) year 2000 crop cover and irrigation rates. We find that irrigation substantially amplifies land cover‐induced climate impacts but has opposing effects across certain regions. Irrigation mostly causes surface cooling, which substantially amplifies land cover change‐induced cooling in most regions except over Central, West, and South Asia, where it reverses land cover change‐induced warming. Despite increases in net surface radiation in some regions, this cooling is associated with enhancement of latent relative to sensible heat fluxes by irrigation. Similarly, irrigation substantially enhances the wetting influence of land cover change over several regions including West Asia and the Mediterranean. The most notable contrasting impacts of these forcings on precipitation occur over South Asia, where irrigation offsets the wetting influence of land cover during the monsoon season. Differential changes in regional circulations and moist static energy induced by these forcings contribute to their precipitation impacts and are associated with differential changes in surface and tropospheric temperature gradients and moisture availability. These results emphasize the importance of including irrigation forcing to evaluate the combined impacts of land surface changes for attributing historical climatic changes and managing future impacts.

Singh, Deepti↗

A monolithic Si bolometer array for the Caltech Submillimeter Observatory

We are developing a submillimeter continuum camera for the Caltech Submillimeter Observatory (CSO) located on Mauna Kea. The camera will employ a monolithic Si bolometer array which was developed by Moseley et al. at the NASA Goddard Space Flight Center (GSFC). The camera will be cooled to a temperature of about 300 mK in a He-3 cryostat, and will operate primarily at wavelengths of 350 and 450 micrometers. We plan to use a bolometer array with 1x24 directly illuminated pixels, each pixel of dimension 1x2 sq mm, which is about half of the F/4 beam size at these wavelengths. Each pixel is 10 to 12 micrometers thick and is supported only by four thin Si legs formed by wet chemical etch. The pixels are doped n-type by phosphorus implantation, compensated by boron implantation. Signals from the bolometer pixels are first amplified by cryogenically cooled FET's. The signals are further amplified by room-temperature amplifiers and then separately digitized by 16 bit A/D converters with differential inputs. The outputs of the A/D converters are fed into a digital signal processing board via fiber-optic cables. The electronics and data acquisition system were designed by the Goddard group. We will report the status of this effort.

Wang, Ning↗

Fabrication of Single Crystal MgO Capsules

A method has been developed for machining MgO crystal blocks into forms for containing metallic and silicate liquids at temperatures up to 2,400 C, and pressures up to at least 320 kilobars. Possible custom shapes include tubes, rods, insulators, capsules, and guides. Key differences in this innovative method include drilling along the crystallographic zone axes, use of a vibration minimizing material to secure the workpiece, and constant flushing of material swarf with a cooling medium/lubricant (water). A single crystal MgO block is cut into a section .5 mm thick, 1 cm on a side, using a low-speed saw with a 0.004 blade. The cut is made parallel to the direction of cleavage. The block may be cut to any thickness to achieve the desired length of the piece. To minimize drilling vibrations, the MgO block is mounted on a piece of adhesive putty in a vise. The putty wad cradles the bottom half of the entire block. Diamond coring tools are used to drill the MgO to the desired custom shape, with water used to wet and wash the surface of swarf. Compressed air may also be used to remove swarf during breaks in drilling. The MgO workpiece must be kept cool at all times with water. After all the swarf is rinsed off, the piece is left to dry overnight. If the workpiece is still attached to the base of the MgO block after drilling, it may be cut off by using a diamond cutoff wheel on a rotary hand tool or by using a low-speed saw.

Danielson, Lisa↗

Road guide to geological points of interest on the island of Hawaii

This road guide briefly describes the points of geologic interest along the main roads on Hawaii. It begins at Hilo and proceeds around the island in a clockwise direction on State Route 11 to Kailua, then returns to Hilo on State Route 19 to Hilo via Waimea, with side excursions on the other principal roads. Minimum excursion time is two days, allowing only very brief time for the various stops. The return to Hilo from Waimea can be made via Route 19 along the Hamakua Coast (wet, leeward side of island, displaying typical tropical erosion) or via Route 20 over the Humuula Saddle (high, relatively dry and cool; young volcanic features).

Stearns, H. T.↗

Variability in Diurnal and Seasonal Ambient Conditions on Geothermal Plant Performance and Cost: Preprint

Geothermal plant performance is bounded by the second law efficiency, which accounts for the quantity of exergy that can be converted into useful work. This in turn is dependent on the geothermal resource temperature and the temperature of the heat sink (i.e., the ambient temperature). In this study we show that ambient temperature variability on a diurnal and seasonal basis can affect performance and cost estimations for geothermal plants. We have utilized the updated System Advisor Model (SAM) to assess nine geothermal sites with existing resource capacities across three climate zones. Our analysis shows that both evaporatively-cooled flash and air-cooled binary cycle plants are affected by temperature, with a slightly higher effect in EGS binary sites. By assuming an ambient (wet bulb) temperature baseline of 15.6 degrees C (60 degrees F) and comparing baseline results to those from site-specific data we observe up to 15% underestimation of plant performance and up to 20% overestimation of cost.

ambient temperature↗