Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “water wire”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Test Results for the SEA Ice Crystal Detector (ICD) under SLD Conditions at the NASA IRT

The Science Engineering Associates hot-wire Ice Crystal Detector was tested under Appendix C and Supercooled Large Drop Conditions at the NASA Icing Research Tunnel, with the purpose of comparing the measurements to the tunnel LWC calibration, and to test the performance of the mixed-phase retrievals of the probe. The liquid water content measured by the total water content sensor of the probe agreed well with the tunnel calibration over a wide range of MVDs, not unexpectedly since the tunnel was calibrated with a similar Multiwire hot-wire probe. A scale factor difference of about 7% was attributed to the lack of an efficiency correction for the Ice Crystal Detector at smaller median volume diameters, and typical sample area uncertainties of liquid water content devices. In addition, the simultaneous equations that are used to retrieve liquid and ice water contents were tested under liquid and glaciated conditions. Using constant ice and water efficiencies for each wire, the equations were found to produce a large and false ice water content retrieval in large median volume diameter liquid cases. By applying a liquid efficiency to the liquid water content sensor that varied with median volume diameter, retrievals were improved such that false ice water content was less than ±10% of the total water content out to the 460 μm median volume diameter limit of the testing. The probe was also tested in glaciated conditions by freezing out a small median volume diameter spray. Using constant ice efficiencies for the two sensors provided from aircraft measurements, the retrieved ice water content was about 40% higher than expected for the case presented, likely due to the ice efficiencies that were used from aircraft measurements of natural clouds being too low for the tunnel’s glaciated sprays. Application of ice efficiencies that vary with particle size and potentially other parameters will be explored for future improvement of retrievals.

Air Craft Icing↗

Test Results for the SEA Ice Crystal Detector (ICD) under SLD Conditions at the NASA IRT

The Science Engineering Associates hot-wire Ice Crystal Detector was tested under Appendix C and Supercooled Large Drop Conditions at the NASA Icing Research Tunnel, with the purpose of comparing the measurements to the tunnel LWC calibration, and to test the performance of the mixed-phase retrievals of the probe. The liquid water content measured by the total water content sensor of the probe agreed well with the tunnel calibration over a wide range of MVDs, not unexpectedly since the tunnel was calibrated with a similar Multiwire hot-wire probe. A scale factor difference of about 7% was attributed to the lack of an efficiency correction for the Ice Crystal Detector at smaller median volume diameters, and typical sample area uncertainties of liquid water content devices. In addition, the simultaneous equations that are used to retrieve liquid and ice water contents were tested under liquid and glaciated conditions. Using constant ice and water efficiencies for each wire, the equations were found to produce a large and false ice water content retrieval in large median volume diameter liquid cases. By applying a liquid efficiency to the liquid water content sensor that varied with median volume diameter, retrievals were improved such that false ice water content was less than ±10% of the total water content out to the 460 μm median volume diameter limit of the testing. The probe was also tested in glaciated conditions by freezing out a small median volume diameter spray. Using constant ice efficiencies for the two sensors provided from aircraft measurements, the retrieved ice water content was about 40% higher than expected for the case presented, likely due to the ice efficiencies that were used from aircraft measurements of natural clouds being too low for the tunnel’s glaciated sprays. Application of ice efficiencies that vary with particle size and potentially other parameters will be explored for future improvement of retrievals.

o Aircraft Icing↗

Crack-Free 30% Chromium-Nickel Alloy Welding Products for Nuclear Service

We report prior research in the development of 30% chromium-nickel alloy nuclear welding wires has resulted in the resolution of primary water stress corrosion cracking (PWSCC) and ductility dip cracking (DDC) as well as improvement in solidification cracking (SC) resistance. The resolution of DDC exhibits some Laves phase, which has a negative effect on SC resistance. In this study, the use of an alternate carbide former, tantalum (Ta), in combination with niobium (Nb) was researched. Three heats of recently designed Filler Metal 52MSS-Ta (i.e., HV1648, HV1673A, and VX131WXW) were melted, fabricated, and systematically studied. DDC and SC were evaluated with thermodynamic modeling using the Scheil solidification simulation model, two types of varestraint tests, and strain-to-fracture (STF) testing. The varestraint and STF test results showed an improved SC resistance with reduced Laves phase and concurrent excellent DDC resistance. Optimized compositions with low Laves phase also exhibited high threshold strain values (TSVs) in the STF test. VX131WXW — which contains 2.81 wt-% Ta, 0.6 wt-% Nb, and 6 wt-% iron (Fe) - exhibited a TSV of 24%. Thermo-Calc computed the Laves phase to be 0.24% for VX131WXW compared to 0.06% in HV1673A. This difference in Laves phase resulted in the lower SC resistance of VX131WXW compared to HV1673A when measured with longitudinal varestraint testing. The maximum crack distance for HV1673A was about 0.6 mm while that of heat VX131WXW was about 1.0 mm. The typical diluted weld deposit made with VX131WXW was also resistant to PWSCC due to the chromium content exceeding 24%. These simultaneous results mark progress toward crack-free welds and provide direction for further optimization of Ta-containing filler metals.

30% chromium-nickel alloy↗

Controller for solar heating-design package

Report contains performance specifications and detailed drawings for two instruments: (1) differential controller, and (2) temperature monitor, for solar-powered water-heating systems. Included in package are schematics, wiring diagrams, test procedures, and parts list.

Source record↗

Mitigating Electrochemical Impedance Spectroscopy Artifacts in PEMWE Reference Electrode Measurements

This study investigates strategies to improve the quality of electrochemical impedance spectroscopy (EIS) measurements using reference electrodes (RE) in proton exchange membrane water electrolyzers (PEMWE). We demonstrate that adding a low impedance wire in parallel to the RE significantly enhances signal accuracy, especially at high frequencies. Additionally, we identify electrical pad heaters as a source of measurement noise. EIS measurements fulfilling Kramers–Kronig validity criteria were only achieved in their absence. These insights advance the diagnostic capabilities of REs in water electrolyzers and support more reliable, spatially resolved analysis of electrochemical losses within the cell.

08 HYDROGEN↗

Effect of Water Droplets Crossing the Boundary Layer in a Stagnation Point Configuration

An experimental study was conducted in the Vertical Icing Studies Tunnel at the Icing Physics Flow Laboratory of NASA Glenn Research Center to study the effect of water droplets crossing the boundary layer in a stagnation point configuration. The objective of the experiment was to determine if water droplets crossing a boundary layer create turbulent spots that accelerate the boundary layer transition from laminar to turbulent. Water droplets that crossed the boundary layer were generated with a nozzle installed in the plenum. The turbulence level in the boundary layer was measured with a hot wire system when the nozzle was off, air on, and air and water on. The results indicate that the presence of the nozzle alone did not affect the boundary layer. The activation of the nozzle to eject air only or to generate water droplets affected the turbulence level in the boundary layer. The continued study of this effect is needed because of its implications in the development of heat transfer models for icing codes.

Icing↗

Some observations of separated flow on finite wings

Wind tunnel test results for aspects of flow over airfoils exhibiting single and multiple trailing edge stall 'mushroom' cells are reported. Rectangular wings with aspect ratios of 4.0 and 9.0 were tested at Reynolds numbers of 480,000 and 257,000, respectively. Surface flow patterns were visualized by means of a fluorescent oil flow technique, separated flow was observed with a tuft wand and a water probe, spanwise flow was studied with hot-wire anemometry, smoke flow and an Ar laser illuminated the centerplane flow, and photographs were made of the oil flow patterns. Swirl patterns on partially and fully stalled wings suggested vortex flow attachments in those regions, and a saddle point on the fully stalled AR=4.0 wing indicated a secondary vortex flow at the forward region of the separation bubble. The separation wake decayed downstream, while the tip vortex interacted with the separation bubble on the fully stalled wing. Three mushroom cells were observed on the AR=9.0 wing.

Winkelmann, A. E.↗

Instrument for Aircraft-Icing and Cloud-Physics Measurements

The figure shows a compact, rugged, simple sensor head that is part of an instrumentation system for making measurements to characterize the severity of aircraft-icing conditions and/or to perform research on cloud physics. The quantities that are calculated from measurement data acquired by this system and that are used to quantify the severity of icing conditions include sizes of cloud water drops, cloud liquid water content (LWC), cloud ice water content (IWC), and cloud total water content (TWC). The sensor head is mounted on the outside of an aircraft, positioned and oriented to intercept the ambient airflow. The sensor head consists of an open housing that is heated in a controlled manner to keep it free of ice and that contains four hot-wire elements. The hot-wire sensing elements have different shapes and sizes and, therefore, exhibit different measurement efficiencies with respect to droplet size and water phase (liquid, frozen, or mixed). Three of the hot-wire sensing elements are oriented across the airflow so as to intercept incoming cloud water. For each of these elements, the LWC or TWC affects the power required to maintain a constant temperature in the presence of cloud water.

Lilie, Lyle↗

CubeSub - A CubeSat Based Submersible Testbed for Space Technology

This report is a Master's Thesis in Aerospace Engineering, performed at the NASA Ames Research Center. It describes the development of the CubeSub, a submersible testbed compatible with the CubeSat form factor. The CubeSub will be used to mature technology and operational procedures to be used in space exploration, and possibly also as a tool for exploration of Earthly environments. CubeSats are carried as payloads, either containing technology to be tested or experiments and sensors for scientific use. The CubeSub is designed to be built up by modules, which can be assembled in different configurations to fulfill different needs. Each module is powered individually and intermodular communication is wireless, reducing the need for wiring. The inside of the hull is flooded with ambient water to simplify the interaction between payloads and surrounding environment. The overall shape is similar to that of a conventional AUV, slender and smooth. This is to make for a low drag, reduce the risk of snagging on surrounding objects and make it possible to deploy through an ice sheet via a narrow borehole. Rapid prototyping is utilized to a large extent, with full-scale prototypes being constructed through 3D-printing and with COTS (Commercial Off-The-Shelf) components. Arduino boards are used for control and internal communication. Modules required for basic operation have been designed, manufactured and tested. Each module is described with regards to its function, design and manufacturability. By performing tests in a pool it was found that the basic concept is sound and that future improvements include better controllability, course stability and waterproofing of electrical components. Further development is needed to make the CubeSub usable for its intended purposes. The largest gains are expected to be found by developing the software and improving controllability.

Europa↗

Postirradiation Examination of WIRE-21 Experiment Irradiated in the High Flux Isotope Reactor

Westinghouse Electric Company is developing wireless sensors to monitor the centerline temperature and internal pressure of commercial light-water reactor fuel rods during irradiation. Oak Ridge National Laboratory and Westinghouse Electric Company developed the Wireless Instrumented RB Experiment 2021 (WIRE-21) to test wireless temperature and pressure sensor technologies in a removable beryllium position in the High Flux Isotope Reactor. The experiment was irradiated for a total of 75 days, at temperatures ranging from approximately 150°C to 400°C, resulting in a peak fast (energy > 0.1 MeV) neutron fluence of about 3 × 10 21 n/cm 2 . The temperature was intentionally cycled multiple times to compare the response of the wireless temperature sensor to collocated thermocouples. Similarly, the pressure sensor was actuated in multiple steps to compare the response of the wireless measurement to excore pressure transducers (Petrie et al., 2023). After irradiation, the experiment was disassembled in the Irradiated Fuels Examination Laboratory (IFEL) hot cell at Oak Ridge National Laboratory with the intent to recover sensor and dosimetry components, document the as-irradiated condition of the hardware, and investigate possible causes of the sensor behavior observed during irradiation. The postirradiation examination successfully recovered and preserved key WIRE-21 components. After the housing was removed using a milling machine, the internal experiment sections were examined. All eight fiber-optic sensors were recovered, cut, and stored. The silicon carbide thermometry, temperature sensor, pressure sensor, lower spacer, and selected pressure and temperature cable sections were also removed and stored. The metal bellows of the pressure sensor was found to be plastically deformed, indicating that it had been properly pressurized during irradiation and generally behaved as expected. X-ray diffraction analysis of a section of one of the irradiated inductor cores within the pressure sensor was performed and confirmed the presence of phase-pure alpha ferrite (i.e., no unexpected phase transformations). Inductance testing was performed on the irradiated pressure sensor cores using an unirradiated test coil, and DC resistance measurements of the transceiver coils were also performed. The measurements with irradiated inductor cores assembled inside unirradiated coils showed slightly reduced inductance compared to measurements made with unirradiated cores, but the difference was not sufficient to explain the more significant reductions in inductance that were observed in-pile. Therefore, it is suspected that degradation of the inductor coils (specifically the wire wrapping) is responsible for the reduced inductance observed in-pile.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A physical criterion for metal ignition.

Ignition temperatures of magnesium ribbon and aluminum wire samples electrically heated in argon-oxygen-carbon dioxide-water vapor mixtures

COMBUSTION TEMPERATURE↗

NASA technology utilization house

Following systems and features, which are predicted to save approximately $20,000 in utility costs over twenty year period, are incorporated into single-level, contemporarily designed, energy efficient residential structure: solar heating and cooling; energy efficient appliances; water recycling; security, smoke, and tornado detectors; and flat conductor electrical wiring.

Source record↗

The generation and propagation of internal gravity waves in a rotating fluid

The present investigation is concerned with an extension of a study conducted bu Maxworthy (1979) on internal wave generation by barotropic tidal flow over bottom topography. A short series of experiments was carried out during a limited time period on a large (14-m diameter) rotating table. It was attempted to obtain, in particular, information regarding the plan form of the waves, the exact character of the flow over the obstacle, and the evolution of the waves. The main basin was a dammed section of a long free surface water tunnel. The obstacle was towed back and forth by a wire harness connected to an electronically controlled hydraulic piston, the stroke and period of which could be independently varied. Attention is given to the evolution of the wave crests, the formation of solitary wave groups the evolution of the three-dimensional wave field wave shapes, the wave amplitudes, and particle motion.

Maxworthy, T.↗

Full Length Assembly Testing in PELICAN (Final Report)

In support of the development of the U.S. Department of Energy (DOE) Versatile Test Reactor (VTR), a thermal hydraulics test facility was constructed to generate experimental measurement of the pressure drop across a single full-scale assembly containing prototypic axial reflectors, fuel, and plena components. Constructed and operated at Argonne National Laboratory, the Pressure drop Experimental Loop for Investigations of Core Assemblies in Nuclear reactors (PELICAN) facility was designed to achieve hydraulic conditions identical to those anticipated for a full-scale fuel assembly located in the VTR core in the region with the highest flow rate. Using water as surrogate for liquid sodium, the flow loop was operated at elevated temperatures and pressures to match the thermophysical properties of liquid sodium and ensure matching Reynolds and Euler numbers. The measurement objectives for data generated from this test facility was driven primarily by the validation needs for code calculations and simulations of the reference VTR core. These objectives focused on the need to validate pressure drop results across the various segments of the fuel assembly as they relate directly to the pumping power and safety of the reactor. Presented in this report are experimental results and analytical comparisons based on testing of a full-length assembly in PELICAN. Housed within a hexagonal test section extending 3.4 m in length, the tested assembly features a prototypic lower reflector, grid plates, wire-wrapped rod bundle, upper reflector, and exit region. The rod bundle extends over 1.5 m in length and contains 217 individual wire-wrapped rods with dimensions that best reflect the reference VTR design. The as-tested bundle assembly was fabricated using 316 stainless steel 0.25-inch (6.35-mm) diameter rods wrapped with 0.04-inch (1.016-mm) diameter wire at a helical pitch of 10.51 inch (26.6 cm). Details of the method for in-house wire-wrapping, assembly, and installation are provided later in this report. Experimental measurements of pressure drop at 19 positions along the test assembly were recorded for a range of flow conditions, with special attention paid to key locations within the assembly, including component inlet and outlet, transition, and wire-wrapped rod bundle regions. Testing conditions were based on 110°C water with flow rates ranging from 50 to 450 GPM (3 to 27 kg/s) at the inlet of the test assembly generating Reynolds numbers and velocities up to ~8.0×10 4 and ~7.8 m/s, respectively, within the rod bundle region. Non-dimensional values for the friction factor were then calculated based on these experimental measurements and compared against those predicted by various analytical correlations available from open literature. Predictions by the upgraded Cheng and Todreas, Rehme, and Novendstern correlations fell within 4% to those values measured experimentally.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Wyandotte Integrated Renewable Energy Strategy (WIRES 2) (Final Technical Report)

Wyandotte Municipal Services (WMS), a Michigan Municipal Utility offering electric generation, transmission & distribution, water filtration & distribution and Broadband/Video sought to deploy a set of renewable energy projects for their Electric Utility that contributed to reducing the City’s environmental and energy impact, provided examples that would encourage businesses and citizens to adopt cleaner energy practices and help WMS meet the required renewable energy standards of the State of Michigan (10% in 2015, 15% in 2021). WMS generates and delivers roughly 280,000 megawatt hours (MWh) of electricity annually to more than 10,000 homes and 1,000 businesses within the City of Wyandotte. The Wyandotte Integrated Renewable Energy Strategy – WIRES 2 resulted in deployment of a set of community-scale micro-wind turbines, evaluation and installation of energy-efficient and low-maintenance light-emitting diode (LED) street lights and park lights in highly visible locations in the City and expansion of the geothermal heating and cooling district that already included residential geothermal systems, to include larger scale business/institutional systems at the Utility’s largest electric customer and at the City Library. Finally, WMS identified the need for job training in energy efficiency and renewable energy technologies to further develop a local skilled workforce in these areas. Partially funded by the grant, the wind turbine project provides a benchmark for WMS, local businesses and residents in the evaluation of utility-scale wind v. micro-wind in an urban environment as a renewable energy strategy. Also partially funded by the grant, the LED project benefited the City of Wyandotte by reducing load on the electric system for the public utility but also reduced City costs for streetlighting, parking lot lighting and park lighting without a compromise in security. The project also resulted in a visual success that has led to additional approvals for non-Grant related LED lighting installations resulting in further reduction in the electric load in the City. Commercial Geothermal installations resulted in the Utility being able to eliminate steam customers who formerly utilized the byproduct of steam from WMS electric production. Due to the reduction in natural gas prices and the overall reduction in market purchased power, it was no longer feasible for WMS to operate its Power Plant as a base load plant and to only operate on a market dispatch philosophy when market prices dictated that WMS could produce electricity cheaper than the market purchase price. This has resulted in fewer operating days for the WMS Power Plant, resulting in less environmental impact. WMS has now completely exited the steam business and the ability to offer a geothermal option to two (2) former steam customers (BASF-Wyandotte and the Bacon Memorial Library) allowed for that. In addition, peak loads have been shaved for these two (2) large customers due to the consistent temperature offered by geothermal heating and cooling, reducing the swings associated with thermostat changes caused by outside temperature changes during extreme high and low temperatures. Finally, energy efficiency and renewable energy college-level classes at Wayne County Community College allowed a group of interested students to pursue studies in those technologies through grant provided tuition, books and course materials. This effort provided a foundation of potential future employees not only for WMS but other energy efficiency/renewable energy employers such as Franklin Energy, a partner with WMS in energy optimization efforts with Wyandotte businesses.

17 WIND ENERGY↗

Measurement of Resistance, Porosity, and Water Contact Angle of Porous Transport Layers for Low-Temperature Electrolysis Technologies

The porous transport layer is an important component of low-temperature electrolysis devices, such as proton exchange membrane water electrolyzers or anion exchange membrane water electrolyzers. PTLs have significant influence on the cell performance as their bulk resistance can impact the ohmic resistance, their contact resistance can impact electrode performance, and their structure can impact the liquid flow to the cell, which could cause mass-transport losses. In order to improve cell performance, optimization of the PTL is critical. Standardized protocols should be utilized to adequately compare PTLs being developed from different institutions. This method will detail a standardized protocol for measuring the resistance of the PTL using a four-wire setup and will also detail a process for measuring the porosity and water contact angle of the PTL using capillary flow porometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗