Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “water use”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Using Neural Network Force Fields to Ascertain the Quality of Ab Initio Simulations of Liquid Water

Accurately simulating the properties of bulk water, despite the apparent simplicity of the molecule, is still a challenge. In order to fully understand and reproduce its complex phase diagram, it is necessary to perform simulations at the ab initio level, including quantum mechanical effects both for electrons and nuclei. This comes at a high computational cost, given that the structural and dynamical properties tend to require long timescales and large simulation cells. In this work, we evaluate the errors that density functional theory (DFT)-based simulations routinely incur into due time- and size-scale limitations. These errors are evaluated using neural-network-trained force fields that are accurate at the level of DFT methods. We compare different exchange and correlation potentials for properties of bulk water that require large timescales. Here we show that structural properties are less dependent on the system size and that dynamical properties such as the diffusion coefficient have a strong dependence on the simulation size and timescale. Our results facilitate comparisons of DFT-based simulation results with experiments and offer a path to discriminate between model and convergence errors in these simulations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Determination of Arsenic Content in Water Using a Silver Coordination Polymer

In this report, we describe a practical method for the colorimetric determination of dissolved inorganic arsenic content in water samples, using a silver coordination polymer as the sensing material. We demonstrate that a crystalline polymer framework can be used to stabilize silver(I) ions, greatly reducing both photosensitivity and water solubility, while still affording sufficient reactivity to detect arsenic in water samples at low parts-per-billion (ppb) levels. Test strips fabricated with the silver-based polymer are shown to be effective for field tests of groundwater under real-world operating conditions and display performance that is competitive with commercially available mercury-based test strips. Spectroscopic methods are also used to probe the reaction products formed, in order to better understand the sensing mechanism. Thus, our work provides the foundation for an improved field test that could be deployed to help manage groundwater usage in regions where arsenic contamination is problematic but sophisticated lab testing is not readily available.

36 MATERIALS SCIENCE↗

MD Simulation of Water Using a Rigid Body Description Requires a Small Time Step to Ensure Equipartition

In simulations of aqueous systems, it is common to freeze the bond vibration and angle bending modes in water to allow for a longer time step δt for integrating the equations of motion. Thus, δt = 2 fs is often used in simulating rigid models of water. We simulate the SPC/E model of water using δt from 0.5 to 3.0 fs and up to 4 fs using hydrogen mass repartitioning. In these simulations, we find that for all but δt = 0.5 fs, equipartition is not obtained between translational and rotational modes, with the rotational modes exhibiting a lower temperature than the translation modes. To probe the reasons for the lack of equipartition, we study the autocorrelation of the translational velocity of the center of mass and the angular velocity of the rigid water molecule, respectively. Here, we find that the rotational relaxation occurs on a timescale comparable to vibrational periods, calling into question the original motivations for freezing the vibrations. Furthermore, a time step with δt ≥ 1 fs is not able to capture accurately the fast rotational relaxation, which reveals its impact as an effective slowing-down of rotational relaxation. The fluctuation–dissipation relation then leads to the conclusion that the rotational temperature should be cooler for δt greater than the reference value of 0.5 fs. Consideration of fluctuation–dissipation in equilibrium molecular dynamics simulations also emphasizes the need to capture the temporal evolution of fluctuations with fidelity and the role of δt in this regard. The time step also influences the solution thermodynamic properties: both the mean system potential energies and the excess entropy of hydration of a soft repulsive cavity are sensitive to δt.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Drought conditioning of rhizosphere microbiome influences maize water use traits

Background and Aims: Beneficial plant–microbe interactions can improve plant performance under drought; however, we know less about how drought-induced shifts in microbial communities affect plant traits. Methods: We cultivated Zea mays in fritted clay with soil microbiomes originating from contrasting environments (agriculture or forest) under two irrigation treatments (well-watered or water limited). Using this design, we investigated whether water conditioning was carried forward through the microbiome to affect a subsequent plant cohort that was subjected to either a well-watered or water limited treatment. Results: Regardless of the microbiome-origin, plants inoculated with a microbiome from a water limited legacy had traits that allowed them to avoid stress but conserve water. They produced longer roots to explore soil, generated greater soil dissolved organic carbon, potentially stimulating the microbiome, and slower soil water content loss during drought. A well-watered legacy resulted in plants that delayed permanent stomatal closure and higher photosynthetic nitrogen use efficiency. In plants with a forest-originated microbiome, a well-watered legacy and water treatment also resulted in higher rates of photosynthesis and stomatal conductance. Conclusion: These results demonstrate that soil microbiomes can be developed to influence plant drought performance, impacting crop resilience, using short-term microbial conditioning.

60 APPLIED LIFE SCIENCES↗

Removal of Calcium and Silica from Simulated Blowdown Water Using CO 2 -Assisted Magnesium Electrocoagulation

Blowdown water from various industries and cooling facilities contains high concentrations of calcium (Ca), magnesium (Mg), silica, and corrosion inhibitors, which render the water unsuitable for discharge into surface water and wastewater treatment plants. Electrocoagulation (EC) is effective at removing Ca and silica. Here, in this study, Mg-alloy electrodes EC resulted in ∼91% silica removal at a 5400 C/L charge loading. Ca removal, however, was only 31%. To enhance Ca removal, carbon dioxide (CO 2 ) containing gas was introduced. CO 2 addition formed carbonate ions, which reacted with Ca/Mg ions to generate carbonate precipitates. Introducing 5% and 14% CO 2 , simulating natural gas-fired and coal-fired flue gas, enhanced Ca removal to 38% and 47%, respectively. Pure CO 2 facilitated 70% Ca removal, more than two times higher than that without CO 2 , while maintaining high silica removal. FTIR, XRD, and SEM-EDS analyses confirmed enhanced Ca/Mg carbonate formation upon CO 2 . In situ Raman spectroscopy was employed to monitor carbonate-ions formation. The results demonstrated carbonate-ions removal through Ca-carbonate formation after CO 2 addition. A techno-economic assessment showed that recycled electrode materials and flue gas lead to ∼3 times lower cost compared with conventional silica/Ca removal through chemical coagulation, softening, or membrane filtration. The study demonstrated that CO 2 addition removes high concentrations of Ca and silica ions from wastewaters at a competitive cost.

blowdown water↗

Electrochemical-driven green recovery of lithium, graphite and cathode from lithium-ion batteries using water

The expected exponential increase in consumption of lithium-ion batteries (LIBs) would pose a unique challenge to the availability of near-critical resources like lithium and graphite in the upcoming decade. In this work, we present a lithium recovery process that utilizes a degradation mechanism, i.e., lithium plating, as a tool to concentrate metallic lithium at the anode/separator interface for convenient extraction at room temperature – using only water. Electrochemical characterization of fast charged (1–6 C) LIBs yielded a maximum capacity fade of 50% over ten cycles. The lithium plating was confirmed via voltage plateau analysis, coulombic efficiency, and DC resistance measurements. A maximum lithium plating condition was observed to exist between 4C and 5C, thereby limiting the energy consumption in the extraction process. Post-mortem film thickness measurement showed an incrementing film deposition with a maximum of 35 µm thickness. SEM and XPS analysis confirmed increasing concentration of a dense dendritic metallic lithium deposition on the anode/separator interface with C-rate. A green recovery process was adopted to extract the concentrated metallic lithium using distilled water. The lithium from the plated film, solid/electrolyte interface (SEI), electrolyte, anode, and cathode, was extracted as salts. A 37% improvement in lithium recoverability was achieved with fast charging under ambient conditions. XPS analysis showed ~92% of lithium yield with no residual lithium in the graphite. In addition, the battery-grade graphite was recovered with 97% purity after heat treatment of the washed anode film, and concentrated transition metals oxides in the cathode to 93% purity for convenient extraction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Identifying schools at high-risk for elevated lead in drinking water using only publicly available data

Estimating the risk of lead contamination of schools' drinking water at the State level is a complex, important, and unexplored challenge. Variable water quality among water systems and changes in water chemistry during distribution affect lead dissolution rates from pipes and fittings. In addition, the locations of lead-bearing plumbing materials are uncertain. We tested the capability of six machine learning models to predict the likelihood of lead contamination of drinking water at the schools' taps using only publicly available datasets. The predictive features used in the models correspond to those with a proven correlation to the dominant, but commonly unavailable, factors that govern lead leaching: the presence of lead-bearing plumbing materials and water quality conducive to lead corrosion. By combining water chemistry data from public reports, socioeconomic information from the US census, and spatial features using Geographic Information Systems, we trained and tested models to estimate the likelihood of lead contaminated tap water in over 8,000 schools across California and Massachusetts. Our best-performing model was a Random Forest, with a 10-fold cross validation score of 0.88 for Massachusetts and 0.78 for California using the average Area Under the Receiver Operating Characteristic Curve (ROC AUC) metric. The model was then used to assign a lead leaching risk category to half of the schools across California (the other half was used for training). There was good agreement between the modeled risk categories and the actual lead leaching outcomes for every school; however, the model overestimated the lead leaching risk in up to 17% of the schools. This model is the first of its kind to offer a tool to predict the risk of lead leaching in schools at the State level. Further use of this model can help deploy limited resources more effectively to prevent childhood lead exposure from school drinking water.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Molecular Dynamics Simulations of Supercritical Carbon Dioxide and Water using TraPPE and SWM4-NDP Force Fields

The increased levels of carbon dioxide (CO 2 ) emissions due to the combustion of fossil fuels and the consequential impact on global climate change have made CO 2 capture, storage, and utilization a significant area of focus for current research. In most electrochemical CO 2 applications, water is used as a proton donor due to its high availability and mobility and use as a polar solvent. Additionally, supercritical CO 2 is a promising avenue for electrochemical applications due to its unique chemical and physical properties. Consequently, understanding the interactions between water and supercritical CO 2 is of great importance for future electrochemical applications. Molecular dynamics (MD) simulation is a powerful tool that enables atomistic-resolution dynamics of molecular systems, which can complement and guide future experimental investigations. This study employed atomistic MD to study the cosolubilities, codiffusivities, and structure of supercritical CO 2 and water systems, with a polarizable water model (SWM4-NDP) and a nonpolarizable CO 2 model (TraPPE). Additionally, ab initio MD simulations were used to better understand how atomistic polarizable/nonpolarizable models compare to explicit modeling of electron densities. The polarizable water model exhibited substantial improvement in water-associated properties. In conclusion, we anticipate the development of a compatible polarizable CO 2 model to yield similar improvement, providing a pathway for realizing novel high-pressure electrochemical systems.

25 ENERGY STORAGE↗

Global monthly sectoral water use for 2010–2100 at 0.5° resolution across alternative futures

Water usage is closely linked with societal goals that are both local and global in scale, such as sustainable development and economic growth. It is therefore of value, particularly for long-term planning, to understand how future sectoral water usage could evolve on a global scale at fine resolution. Additionally, future water usage could be strongly shaped by global forces, such as socioeconomic and climate change, and the multi-sector dynamic interactions those forces create. We generate a novel global gridded monthly sectoral water withdrawal and consumption dataset at 0.5° resolution for 2010–2100 for a diverse range of 75 scenarios. The scenarios are harmonized with the five Shared Socioeconomic Pathways (SSPs) and four Representative Concentration Pathways (RCPs) scenarios to support its usage in studies evaluating the implications of uncertain human and earth system change for future global and regional dynamics. To generate the data, we couple the Global Change Analysis Model (GCAM) with a land use spatial downscaling model (Demeter), a global hydrologic framework (Xanthos), and a water withdrawal downscaling model (Tethys).

54 ENVIRONMENTAL SCIENCES↗

Multiplexed Anodic Stripping Voltammetry Detection of Heavy Metals in Water Using Nanocomposites Modified Screen-Printed Electrodes Integrated With a 3D-Printed Flow Cell

In this study, we present multiplexed anodic stripping voltammetry (ASV) detection of heavy metal ions (HMIs)—As(III), Cd(II), and Pb(II)—using a homemade electrochemical cell consisting of dual working, reference and counter screen-printed electrodes (SPE) on polyimide substrate integrated with a 3D-printed flow cell. Working and counter electrodes were fabricated by the screen-printing of graphite paste while the Ag/AgCl paste was screen-printed as a reference electrode (Ag/AgCl quasi-reference electrode). The working electrodes were modified with (BiO) 2 CO 3 -reduced graphene oxide (rGO)-Nafion [(BiO) 2 CO 3 -rGO-Nafion] and Fe 3 O 4 magnetic nanoparticles (Fe 3 O 4 MNPs) decorated Au nanoparticles (AuNPs)-ionic liquid (IL) (Fe 3 O 4 -Au-IL) nanocomposites separately to enhance HMIs sensing. Electrochemical detection was achieved using square wave ASV technique. The desired structure of the flow electrochemical cell was optimized by the computational fluid dynamic (CFD). Different experimental parameters for stripping analysis of HMIs were optimized including deposition time, deposition potential and flow rate. The linear range of calibration curves with the sensing nanocomposites modified SPE for the three metal ions was from 0–50 μg/L. The limits of detection (S/N = 3) were estimated to be 2.4 μg/L for As(III), 1.2 μg/L for Pb(II) and 0.8 μg/L for Cd(II). Furthermore, the homemade flow anodic stripping sensor platform was used to detect HMIs in simulated river water with a 95–101% recovery, indicating high selectivity and accuracy and great potential for applicability even in complex matrices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of satellite Leaf Area Index in California vineyards for improving water use estimation

Remote sensing estimation of evapotranspiration (ET) directly quantifies plant water consumption and provides essential information for irrigation scheduling, which is a pressing need for California vineyards as extreme droughts become more frequent. Many ET models take satellite-derived Leaf Area Index (LAI) as a major input, but how uncertainties of LAI estimations propagate to ET and the partitioning between evaporation and transpiration is poorly understood. Here we assessed six satellite-based LAI estimation approaches using Landsat and Sentinel-2 images against ground measurements from four vineyards in California and evaluated ET sensitivity to LAI in the thermal-based two-source energy balance (TSEB) model. We found that radiative transfer modeling-based approaches predicted low to medium LAI well, but they significantly underestimated high LAI in highly clumped vine canopies (RMSE ~ 0.97 to 1.27). Cubist regression models trained with ground LAI measurements from all vineyards achieved high accuracy (RMSE ~ 0.3 to 0.48), but these empirical models did not generalize well between sites. Red edge bands and the related vegetation index (VI) from the Sentinel-2 satellite contain complementary information of LAI to VIs based on near-infrared and red bands. TSEB ET was more sensitive to positive LAI biases than negative ones. Positive LAI errors of 50% resulted in up to 50% changes in ET, while negative biases of 50% in LAI caused less than 10% deviations in ET. However, even when ET changes were minimal, negative LAI errors of 50% led to up to a 40% reduction in modeled transpiration, as soil evaporation and plant transpiration responded to LAI change divergently. These findings call for careful consideration of satellite LAI uncertainties for ET modeling, especially for the partitioning of water loss between vine and soil or cover crop for effective vineyard irrigation management.

54 ENVIRONMENTAL SCIENCES↗

Reversible parts-per-trillion-level detection of perfluorooctane sulfonic acid in tap water using field-effect transistor sensors

Widespread, persistent and toxic per- and polyfluoroalkyl substances (PFAS) pose a major threat to water systems and human health. Current detection methods are relatively expensive, slow and complex, underscoring the need for more accessible alternatives to meet increasingly stringent PFAS regulations. Here, in this study, we present an ultrasensitive sensing platform for perfluorooctane sulfonic acid detection in tap water with a reporting limit ( ~ 250 parts per quadrillion) lower than the US Environmental Protection Agency’s regulatory standard (4 parts per trillion), using a remote gate field-effect transistor featuring β-cyclodextrin (β-CD)-modified reduced graphene oxide as the sensing membrane. The sensor exhibits excellent selectivity against common inorganic ions, natural organic matter and select organic pollutants in tap water. The reversible and rapid response ( < 2 min) indicates the potential of remote gate field-effect transistor for continuous in-line monitoring. Mechanistic studies using quartz crystal microbalance and molecular dynamics simulations reveal key roles of analyte adsorption and charge properties in sensing performance and offer insights for designing more selective PFAS capture probes.

Wang, Yuqin [University of Chicago, IL (United Sta↗

Retrieval of Cloud Liquid Water Using Microwave Signals from LEO Satellites: A Feasibility Study through Simulations

A novel method, using low Earth orbit (LEO) satellite microwave communication links for cloud liquid water measurements, is introduced in this paper. The feasibility of this approach is studied through simulations of the retrieval system including a LEO satellite communicating with a group of ground receivers equipped with signal-to-noise ratio (SNR) estimators, a synthetic cloud attenuation field and a tomographic retrieval algorithm. Rectangular and Gaussian basis functions are considered to define the targeted field. Simulation results suggest that the proposed least-squares based retrieval algorithm produces satisfactory outcomes for both types of basis functions. The root-mean-square error of the retrieved field is around 0.2 dB/km, with the range of the reference field as 0 to 2.35 dB/km. It is also confirmed that the partial retrieval of the cloud field is achievable when a limited number of receivers with restricted locations are available. The retrieval outcomes exhibit properties of high resolution and low error, indicating that the proposed approach has great potential for cloud observations.

54 ENVIRONMENTAL SCIENCES↗

Separation of volatile organic contaminants from water using a direct-contact dehumidifier: An experimental study and modeling

A packed-bed, direct-contact dehumidifier (PB-DCD) has been developed to selectively condense water from a gaseous mixture of organic contaminants. In this process, hot air is humidified by mixing with wastewater vapor in a static mixer and is dehumidified by subcooled fresh water passing through the PB-DCD in a counter-current configuration. The goal of this study is to understand the relationship between various operating parameters and how they affect separation of isopropyl alcohol (IPA) from the gaseous mixture with the purpose of expanding the investigation to other contaminants in the future. The process has been successfully used to separate IPA from wastewater. Different parameters including the concentration of IPA in water, feed temperature, air-to-vapor ratio, and cooling-water-to-vapor mass ratio, as well as residence time were examined to determine their influence on contaminant separation and clean water recovery rate. The Buckingham Pi theorem was applied to reduce the number of studying variables by generating non-dimensional groups. Experiments were performed to determine the relationship between the non-dimensional parameters and model mass transfer in the system. Mass transfer coefficients for multicomponent gaseous mixture condensation in a packed-bed direct contact condenser column are calculated and a modified correlation of mass transfer is developed. The parameters of the mass transfer model are obtained from operating conditions of the PB-DCD, stream conditions and thermodynamic properties. A modified Sherwood correlation is developed to predict IPA separation from a gaseous mixture consisting of air, water, and IPA. The modified Sherwood correlation is applied to successfully predict the Sherwood number with a mean absolute error equal to 6.6 %. According to the experimental results, the maximum IPA separation achieved was 76.3 %, which corresponds to a water recovery rate of 58.7 %.

42 ENGINEERING↗

Rapid photooxidation and removal of As(III) from drinking water using Fe-Mn composite oxide

Fe-Mn composite oxide (FMO) is widely applied to the oxidation and removal of As(III) from water. However, As(III) can directly reduce manganese oxides, decreasing the oxidation capacity or reusability and thereby greatly limiting the applicability of FMO. Here, the oxidation capacity and reusability of FMO for As(III) were efficiently improved by light radiation, and the effect of typical coexisting ions (SO 4 2– and Ca 2+ ) on the removal of As(III) was also studied. O 2 •– produced from excited manganese oxide and ligand-to-metal charge transfer in iron oxide-As(III) complex enhanced As(III) oxidation and removal under light radiation. At an initial As(III) concentration of 1000 μg L –1 , the total As concentration was respectively decreased to 11.5, 1.5 and 4.4 μg L –1 under darkness, UV light and sunlight at 180 min, and could be reduced to below the guideline limitation of drinking water (10 μg L –1 ) within 40 and 60 min under UV light and sunlight, respectively. SO 4 2– exhibited negligible effect on As removal efficiency because FMO had obviously lower adsorption capacity and selectivity for SO 4 2– than for As(V). The adsorption of coexisting Ca 2+ on manganese oxide decreased the negative charge on the FMO surface, thereby improving As(III) adsorption and oxidation. FMO exhibited excellent reusability, and a total As removal efficiency of 99.1% was still maintained after five cycles of an adsorption-desorption process under UV light. Finally, this work elucidates the photochemical oxidation and removal mechanism of FMO for As(III), and proposes a low-cost and efficient method for the detoxification of As(III)-contaminated drinking water.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhancement and maximum in the isobaric specific-heat capacity measurements of deeply supercooled water using ultrafast calorimetry

Knowledge of the temperature dependence of the isobaric specific heat (C p ) upon deep supercooling can give insights regarding the anomalous properties of water. If a maximum in C p exists at a specific temperature, as in the isothermal compressibility, it would further validate the liquid–liquid critical point model that can explain the anomalous increase in thermodynamic response functions. The challenge is that the relevant temperature range falls in the region where ice crystallization becomes rapid, which has previously excluded experiments. Here, we have utilized a methodology of ultrafast calorimetry by determining the temperature jump from femtosecond X-ray pulses after heating with an infrared laser pulse and with a sufficiently long time delay between the pulses to allow measurements at constant pressure. Evaporative cooling of ~15-µm diameter droplets in vacuum enabled us to reach a temperature down to ~228 K with a small fraction of the droplets remaining unfrozen. We observed a sharp increase in C p , from 88 J/mol/K at 244 K to about 218 J/mol/K at 229 K where a maximum is seen. The C p maximum is at a similar temperature as the maxima of the isothermal compressibility and correlation length. From the C p measurement, we estimated the excess entropy and self-diffusion coefficient of water and these properties decrease rapidly below 235 K.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗