Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “water heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Highly Resolved Reference Projections of Building Energy Use for the Contiguous United States: Building Sector Energy Baselines, Projection Methods, and Results

This report describes one methodology of projecting energy consumption of the US residential and commercial building sectors using NREL's ResStock™ and ComStock™ as well as growth rates derived from EIA's Annual Energy Outlook (AEO). The impetus for this work is to provide an intermediate method for compiling demand-side sectoral energy projections that is suitable for grid-scale analysis, such as NREL's Standard Scenarios. ResStock and ComStock are physics-based and statistically representative building stock models of the US residential and commercial sector, respectively. Using the 2012 actual meteorological year (AMY) weather data, the sectoral energy baselines are simulated and then segmented along key dimensions (e.g., geography, dwelling/building type). The segmented results are then scaled using the corresponding annual growth rates derived from the 2021 AEO reference case to produce energy projections out to 2050. The compiled result is a demand-side grid model (dsgrid) data set suitable for use in NREL's large-scale grid models, such as the Regional Energy Deployment System (ReEDS). This simple projection method does not endogenously represent how the building stock could evolve through time. Most notably, it does not reflect large-scale electrification, for example, the conversion of space heating, water heating, clothes drying, and cooking from primary fossil fuels to electricity, as this is not part of AEO's reference case assumptions. Nonetheless this approach is more resolved and potentially extensible compared to the current method used by Standard Scenarios's reference case, which augments a sector's total load based on a single growth rate from AEO.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

California Price Response Potential Study

California's energy landscape is undergoing a significant transformation, driven by the increasing integration of renewable energy sources, the increased adoption of distributed energy resources, the electrification of end-use loads, and the growing need for grid efficiency. To address these challenges, recent revisions to the State’s Load Management Standards (LMS) require all of California’s large utilities and community choice aggregators (CCAs) to offer dynamic electricity pricing options to customers by 2027. Dynamic pricing, which involves varying electricity rates based on real-time supply and demand conditions, offers a promising solution for optimizing grid operations, reducing costs, and incentivizing efficient use of grid capacity. Effective implementation of dynamic pricing requires understanding the potential impacts on customer bills, system load, and the cost-effectiveness of automation technologies. This study aims to evaluate the load response of various end-use devices to hourly dynamic prices. The end-uses studied here are space cooling, space heating, water heating, crop irrigation, pool and spa pumps, and electric vehicle (EV) charging, all for both residential and commercial applications, except for crop irrigation. In 2030, these end uses are forecasted to account for 18% of annual electricity demand in the state, but 40% of demand in the peak net load hour. By modeling possible price-responsive load dispatch algorithms and assessing the resulting impacts on both individual bills and the overall grid, we seek to inform policymakers and utilities about the potential benefits and challenges associated with dynamic pricing, and considerations for the design of dynamic pricing tariffs. Additionally, we will explore the cost effectiveness of adopting automation technologies to enable devices to respond more effectively to real-time price signals. This study considers a range of price profiles, accounting for differences across utilities and customer classes, and presents scenarios for dynamic price design via variation in the percentage of total customer electric costs that are allocated dynamically (versus constituting a fixed portion of the hourly volumetric price). We present results focused primarily on 2030, forecasting electricity prices under both low and high-cost scenarios, to inform longer-term tariff design considerations. We design tariffs by starting with 2019 prices that were calculated according to CalFUSE guidance (CPUC, 2022) and that have been used in recent studies; these prices are all-in volumetric rates that vary by utility and are revenue-neutral to each customer class. They are developed by considering six electricity cost components that are allocated hourly based on system load indicators (gross and net load, and wholesale prices). These prices are forecasted to 2030 for low and high cost scenarios, considering recent trends in total electricity costs with and without years of substantial wildfire mitigation investments. These tariffs, which allocate all costs on an hourly basis, are considered our “Full” dynamic tariff design scenario, while two additional scenarios explore allocating a portion of costs as a flat volumetric charge: the “Medium” scenario allocates 50% of revenue dynamically (and keeps 50% flat), while the “Mild” scenario allocates 20% of revenue dynamically. The 20% dynamic allocation on the Mild scenario aims to represent a case where only the marginal operating costs of the grid are included in the dynamic price.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A fuel cell energy storage system for Space Station extravehicular activity

The development of a fuel cell energy storage system for the Space Station Extravehicular Mobility Unit (EMU) is discussed. The ion-exchange membrane fuel cell uses hydrogen stored as a metal hydride. Several features of the hydrogen-oxygen fuel cell are examined, including its construction, hydrogen storage, hydride recharge, water heat, water removal, and operational parameters.

Rosso, Matthew J., Jr.↗

Field Study of 120-volt Heat Pump Water Heaters in the Big Easy

To meet long-term goals for reducing carbon emissions and lessen the impacts of climate change, the U.S. plans to decarbonize its building stock, which includes the replacement of fossil fuel-burning end uses with energy efficient electric alternatives. As part of this strategy, the replacement of fossil fuel water heaters with heat pump water heaters (HPWH) has the potential to avoid substantial carbon emissions. An estimated 10-15 million single-family homes with fossil fuel water heaters do not have the electrical panel capacity to install a 240-volt, 30-amp HPWH. For these homes, a technology recently introduced to the market, the 120-volt plug-in HPWH, can provide energy efficient electrification of water heating without an expensive panel and wiring retrofit. This paper presents the results of an ongoing 120-volt HPWH field study conducted in 17 homes in New Orleans, LA. Key installation scenarios are profiled for retrofitting from gas-fired water heaters to 120-volt HPWHs, accounting for space, air volume, air temperature, condensate drainage, and electrical. Each HPWH had its surrounding air temperature, relative humidity, inlet and outlet water temperature, flow, and energy consumption monitored. Using these data, hot water delivery and energy efficiency performance were analyzed based on home characteristics. Hot water run outs were investigated to understand how hot water usage, inlet water temperature, and surrounding air temperature impact the HPWH’s ability to meet load. From these results, best practices for 120-volt HPWH siting, sizing, and installation were developed. In addition, results are explored further to add insight for electrification policies and product development.

heat pump water heater, 120-volt, Residential buil↗

Scaling Up: Demonstrating Risk Reduction and Cost Compression for Commercial Heat Pump Water Heaters - CRADA 625 (Abstract)

Commercial heat pump water heater (CHPWH) systems significantly decarbonize the commercial and multifamily sectors by eliminating the reliance on gas-fired water heating. CHPWH systems are also well suited to include load shift controls that enable load-up and shed commands for supporting grid reliability and time-of-use pricing structure. However, they have not had wide adoption due to factors including price, complexity, and perceived risk. Although CHPWHs have been available in the US for decades, they have not made significant market gains in part because the systems have required significant and costly engineering design expertise and proved lackluster performance. Successful widespread market adoption requires a different approach; a shift from the current custom specialized expertise project design and installation to a repeatable approach that requires little specialized knowledge or expertise and can deliver persistent performance. Using this type of holistic systems approach requires effectively integrating four CHPWH system key components: primary air-to-water heat pumps; primary thermal storage tanks, a temperature maintenance system, and a control system which has capabilities to manage the primary heat pump cycles, any back-up, supplemental, or temperature maintenance heating, alarms, and grid connectivity allowing for demand response (DR), and/or load shifting. The project team has developed and will implement a suite of tools to support faster, less expensive, and more reliable field installations of CHPWH technology and with the resulting data used to further improve the tool set. These tools include: (1) A tool for optimizing system size and costs. (2) A tool that predicts annual energy use and overall system efficiency. (3) The Advanced Water Heater Specification (AWHS 8.0) defining the components of a full CHPWH system addressing performance requirements by climate zone. (4) The Qualified Products List: (QPL) of approved products that meet the specifications requirements. (5) Training materials including online on-demand modules, instructor-led training, and virtual interactive video tours of CHPWH installations in multifamily buildings. Demonstration site identification in low-income buildings in underserved communities is currently underway. Preliminarily, the team anticipates having three demonstrations in the Pacific Northwest and three in the Northeast for a total of six sites. After the demonstration sites are finalized, and M&V instrumentation installations are complete, the team will gather performance data and confirm whether the CHPWH systems perform as predicted and use the data to improve the existing tools.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solar heating and cooling of buildings

Solar energy has been used for space heating and water heating for many years. A less common application, although technically feasible, is solar cooling. This paper describes the techniques employed in the heating and cooling of buildings, and in water heating. The potential for solar energy to displace conventional energy sources is discussed. Water heating for new apartments appears to have some features which could make it a place to begin the resurgence of solar energy applications in the United States. A project to investigate apartment solar water heating, currently in the pilot plant construction phase, is described.

Bourke, R. D.↗

Charge Reduction and Performance Analysis of a Heat Pump Water Heater Using R290 as a Refrigerant—A Field Study

Heat pump water heaters (HPWHs) are a proven technology for water heating that has been commercialized. The adoption of HPWHs for domestic and commercial water heating is growing rapidly because of their superior performance compared with alternative water heating methods. Whereas most existing systems use R-134a as a working refrigerant, R290 has gained major attention owing to its superior thermodynamic properties. The goal of the current study is to assess the performance of residential HPWH with R290 as a direct refrigerant replacement for R134a. Two units of a 50 gal HPWH were used in this experimental study. A baseline unit contained R134a refrigerant, and a prototype unit contained R290 refrigerant. The prototype unit was developed through the modification of a commercially available HPWH unit to achieve a low charge of R290 refrigerant. Another major modification was the replacement of the baseline compressor with a compressor designed for R290. Tests were conducted in a field environment (a research and demonstration house) using programmed drawn profiles daily. The prototype that reduced the charge by 43–47% provided displayed performance comparable to the baseline unit regarding first-hour rating (FHR) and the uniform energy factor (UEF).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Simulation Study of 120V Heat Pump Water Heaters

A 120 V heat pump water heater (HPWH) is a direct plug-in option to replace gas water heater (WH) without needing expensive electric panel upgrade to 220 V. To enable the smooth transition, the HPWH should provide comparable water heating capacity as the gas WH. WH capacities are rated in the form of first hour rating (FHR). Typical home gas WHs have FHRs > 65 gallon with a 40-gallon water tank. It imposes a major challenge on 120V HPWHs. Most 120V circuits in US can provide 1,800 to 2,400W, not adequate to drive electric resistance heat to boost FHRs. Thus, all the heat needs to come from the heat pump with its top power below 1500 Watts, which is constraint by the installation footprint. This study uses a hardware based, HPWH design model, i.e. the DOE/ORNL Heat Pump Design Model to design a 120V unit with a brazed plate condenser, fin-and-tube evaporator and an adequately sized compressor. To maximize the FHR, multiple strategies were simulated, including use of a mixing valve, overheating the tank temperature to 140F, a new sensing method for quicker response, and an innovative water circulation path. We also simulated 24-hour unform energy factors (UEF) to show the tradeoff between the capacity and operation efficiency. Additionally, we evaluated the impact of insulation thickness on FHR and UEF, to seek further footprint reduction or stretch the tank volume.

Shen, Bo↗

MaxTech HPWH Using Ultra-low GWP Refrigerant

Heat pump water heaters (HPWHs) are a proven technology for water heating that has been commercialized. The adoption of HPWHs for domestic and commercial water heating is growing rapidly because of superior performance compared with that of alternative water heating methods. Whereas most existing systems use R-134a as a working refrigerant, significant interest exists for deploying low global warming potential refrigerants to minimize environmental impacts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cold Climate Integrated Heat Pump with Energy Storage for Grid-Responsive Control

An air-source integrated heat pump (ASIHP) is a multifunctional unit, capable of space cooling, space heating, and water heating. We developed a packaged cold climate ASIHP, using a multi-stage compressor, capable of working down to -25°C, and providing 100% rated capacity down to -15°C with a heating COP > 2.2. An innovative system configuration and related controls were developed to solve charge balance in the integrated heat pump, smooth charge migration, and mode transition among multiple working modes. Extensive laboratory investigations for individual modes were performed to verify the performance. Its integrated heating capability provides speedy water heating to meet domestic hot water use and store heating energy in a phase change material ceiling/panel. The heating energy storage can be used to shift the load when the electricity price is high. Based on the performance data and a calibrated model from the laboratory testing, we conducted building energy simulations driven by a model predictive control, using EnergyPlus in one U.S. cold climate zone to investigate the grid-responsive control strategy and estimate the utility cost reduction potential.

Shen, Bo↗

Enhancing heat pump water heater performance with embedded phase change materials thermal energy storage: First hour rating improvement and demand response operation

The increasing global emphasis on energy efficiency and sustainability has put heat pump water heaters (HPWHs) in the spotlight as an energy-efficient alternative to traditional water heating systems. However, their widespread adoption is limited by challenges such as insufficient First Hour Rating (FHR), suboptimal control mechanisms, and limited flexibility for demand response operations. Here, to address these limitations, this study proposes an innovative HPWH system integrated with embedded phase change material (PCM)-based thermal energy storage (TES). The research introduces a novel design and control strategy that leverages optimized PCM integration to enhance thermal storage capacity, improve hot water delivery during peak demand, and increase load-shifting potential. A combination of system modeling, performance simulation, and demand response control strategy evaluation was employed to quantify the benefits of PCM integration. Results demonstrate that the proposed PCM-TES HPWH system significantly enhances FHR, with an optimal 7.0 lb. of PCM increasing FHR by over 26 %—from 62 to 78 gal—for a standard 50-gal HPWH. Additionally, under advanced demand response operation using a preheat strategy, the system reduces the percentage of control temperature out-of-band time from 65 % (conventional HPWH) to just 11.6 %, enabling a more stable and efficient hot water supply. This research contributes a novel PCM-embedded HPWH design and control framework that addresses both performance and grid-interactivity challenges. The findings offer a viable pathway to enhancing the operational efficiency, flexibility, and grid responsiveness of residential water heating systems.

Demand response control↗

Factors Influencing Grid-connected Heat Pump Water Heater Performance in the Southeast U.S.

Grid-connected heat pump water heaters (HPWH) can shift electrical load while minimizing impacts to hot water availability for occupants. This capability provides a flexible grid resource to utilities seeking to manage peak loads Such load control also can feasibly improve renewable utilization within the utility electric production mix, for instance using off-peak generation during periods with high renewable energy generation. It also offers lower electric bills to customers through increased energy efficiency of HPWH and cuts greenhouse gas emissions. In particular, the Southeast U.S. due to its high penetration of electric water heating presents a promising opportunity for grid-connected HPWHs. This paper builds upon the results of an extensive HPWH load shifting field study conducted in 51 occupied homes in Florida using EcoPort technology (Butzbaugh et al, 2022). In 2022, only an initial evaluation was available. Here, long term load results are available as well as examination of various control strategies and influences. Analysis is conducted for HPWH energy use and load shifting performance based on home occupancy (i.e., low and high) and water heater location (i.e., conditioned and unconditioned) across different temperature profiles. An unexpected outcome of this analysis was the poor performance of HPWHs located in conditioned spaces, possibly because of inadequate air volume from improper installation. We did find higher demand reductions from 2-hour load ups and slightly improved for critical peak signals in the afternoon control periods. As expected, higher occupancy households showed great load reductions.

Fenaughty, Karen↗

X-ray free electron laser heating of water and gold at high static pressure

Probing of reactive materials such as H 2 O ices and fluids at the high pressures and temperatures of planetary interiors is limited by unwanted chemical reactions and confinement failure. Faster experiments can mitigate such issues, but the common approach of adiabatic compression limits the conditions achieved. This study demonstrates a fast experimental strategy for the creation and probing of selected extreme states using static compression coupled with ultrafast X-ray laser heating. Indirect X-ray heating of H 2 O through the use of a gold absorber is evidenced by sample melting inferred from textural changes in the H 2 O diffraction lines and inter-dispersion of gold and H 2 O melts. Coupled with numerical analysis of femtosecond energy absorption, thermal equilibration, and heat transfer, all evidence indicates that temperatures in excess of an electron volt have been reached in the H 2 O at high pressure. Even after repeated heating, samples stayed chemically unchanged from the starting material.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Heat exchanger(s) for recovering water and/or heat energy from turbine engine combustion products

A turbine engine is provided that includes a fan section, a turbine engine core and a recovery system. The turbine engine core is configured to power the fan section. The turbine engine core includes a core compressor section, a core combustor section and a core turbine section. A centerline axis of the turbine engine core is offset from a centerline axis of the turbine engine. The recovery system includes an evaporator module and a condenser module. A core flowpath extends sequentially through the core compressor section, the core combustor section, the core turbine section, the evaporator module and the condenser module from an inlet into the core flowpath to an exhaust from the core flowpath.

Sobanski, Jon E.↗

Detailed Evaluation of Electric Demand Load Shifting Potential of Heat Pump Water Heaters

Future utilities will emphasize home appliances to reduce greenhouse gas emissions while providing electric load shifting and demand profile management. Heat pump water heaters (HPWH) have demonstrated the ability to cut water heating energy by more than 65% compared with conventional electric resistance waters (ERWH). Laboratory research was conducted on the load shifting potential of grid-connected heat pump water heaters (HPWH), compared to ERWHs. Testing applied different CTA-2045 command designs. Highly-controlled laboratory experiments were conducted on one ERWH and four HPWHs, including a prototype incorporating the new CTA-2045-B protocol feature allowing ‘advanced’ load up above the tank setpoint. The prototype unit with the B-protocol increased tank temperature by 15oF (8.3C) under the advanced load up providing an increase of 1.8 kWh of storage for a 50-gallon (189 liter) tank. The prototype includes a built-in mixing valve to meet anti-scalding codes. With the load-shaping ability of CTA-2045-B, utilities might be able to store excess renewable energy in connected tanks when renewable wind and solar resource production is high. Tests were performed under baseline conditions (no load shift) and under several load-shifting schemes, including load up and advanced load up, ahead of shed commands. Grid-connected HPWHs reduced peak demand by as much as 0.5 kW, depending on tank volume, time of day, control scheme, and draw profile.

heat pump water heater, Demand flexibility, load s↗

The Empirical Effect of Fleet Optimization on Synchronization and Rebound Effects in Heat Pump Water Heaters

Demand response is a growing concept in light of the internet of things and an increasing need for grid flexibility. Water heaters are one of the preferred devices for providing demand response for grid services and peak management due to their capability to store energy. The efficient use of water heaters for demand response requires consideration of the associated load effects such as synchronization of device schedules and rebound effect. These effects present a significant challenge. Despite the importance of the mentioned effects for water heater queuing and scheduling, there has been no effort to quantify and empirically validate their impact. This study attempts to address this gap by offering two methods - Ward clustering and Euclidean K-means - to evaluate the extent of synchronization in a fleet of 42 water heaters in Atlanta, GA. Using the aforementioned methods on the measured data, we find evidence of convergence of water heater loads as a result of optimization compared to an idle period and analyzed their impact.

demand response↗