Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “water heater”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Development and Evaluation of Distributed Energy Resource Device Models: Electric Vehicles, Electric Water Heaters, and Commercial Refrigeration Systems

In order to validate distributed energy resource (DER) models operated with grid services in the GMLC 1.4.2 team’s February (GMLC 2019a) and July (GMLC 2019b) reports, a test and measurement program using actual DER devices was conducted by national laboratories for three devices: (1) electric vehicles (EVs), (2) water heaters, and (3) commercial refrigeration. Test procedures were developed and carried out to identify the mathematical models and their parameters that describe the operational function, characterize the physics, and obey transient response of the devices. This report focuses on the experimental results obtained to develop and verify simulations of three specific EV models. This section summarizes elements of the mathematical model and shows the necessity data collected from the EVs while charging and discharging (driving). In the course of the study, we found it necessary to make some modifications to the model to deal with observed transient behavior. Section 1.2 details the model assumptions and equations, Section 1.3 provides details of the EVs tested, Section 1.4 outlines the test procedures developed for the projects, and Section 1.5 presents the experimental results obtained for the three different EVs tested and how these results compare to the models running the same test profiles.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Solar Water Heater

Skylab derived Heating System offers computerized control with an innovative voice synthesizer that literally allows the control unit to talk to the system user. It reports time of day, outside temperature and system temperature, and asks questions as to how the user wants the system programmed. Master Module collects energy from the Sun and either transfers it directly to the home water heater or stores it until needed.

Source record↗

Real-Time MPC for Residential Building Water Heater Systems to Support the Electric Grid

The world of IoT (internet of things) is spawning new control options and decision making that has not been available before. This is providing a wealth of opportunities for transactive type controls and systems that can negotiate for a common goal. This paper discusses a transactive residential neighborhood with optimization at the home level utilizing a system of agents. The real-time optimization utilizes information and modeling to optimize heat pump water heater operation in occupied homes. Data is presented showing the performance of the optimization and conclusions are drawn on next steps for development.

Starke, Michael↗

Theoretical Analysis of a Single-Stage Gas-fired Ejector Heat Pump Water Heater

Ejector-driven systems have the ability to operate at high efficiencies, utilizing recycled thermal energy as a power source. For a typical ejector heat pump (EHP) system, the increase of the condenser temperature reduces the coefficient of performance (COP). In addition, if the condenser temperature is higher than the critical temperature, the ejector may not function. In this situation, the condenser temperature must be reduced, and an additional heater will be utilized to heat the production water from the condenser temperature to the desired temperature. In this study, a single-stage gas-fired EHP is investigated and thermodynamically modeled to optimize the system COP for the purpose of heating water by utilizing the thermal energy from the ambient air. The effects of the high-temperature evaporator (HTE) and low-temperature evaporator (LTE) on the ejector critical back pressure and the EHP system performance are examined for a HTE temperature range of 120–180 °C and LTE temperatures of 15.5, 17.5, and 19.5 °C. Our results show that an optimized COP for the EHP system exists and is dependent on HTE and LTE temperatures and the primary nozzle throat diameter. In addition, it is found that the peak EHP COP does not necessarily coincide with a large ejector COP. From this study, a maximum EHP COP of 1.31 is achieved at a HTE temperature of 170 °C and LTE temperature of 19.5 °C with a total heating capacity of 15.98 kW.

42 ENGINEERING↗

Custom Controls for Improved Demand Response from Heat Pump Water Heaters

As part of a Grid Modernization Laboratory Consortium (GMLC) project looking at defining grid services for a range of devices, NREL used a custom controller to investigate the ability of a HPWH to provide load add and load shed in hybrid and electric resistance mode using standard set point control. Based on those results, changes were made to the controls to increase the amount of grid services delivered, especially in the load-add case, and speed up the recovery from those events. The custom controls also include less common methods, such as duty cycling of the heat pump or elements. The improved controls led to an increase the amount of demand response that could be provided and enabled faster recovery. Results from the laboratory experiments will be presented, along with details about the custom controls that were implemented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimization and Experimental Validation of Annular Finned PCM-HX for a Domestic Hot Water Heater Application

The load profile for domestic water heating is time-dependent and can result in high energy demand during peak operating times. Shifting this peak load can have significant environmental and economic impacts. Phase change material (PCM)-based thermal energy storage (TES) is a potentially useful technology for peak load shifting in domestic hot water (DHW) applications thanks to its high latent heat and energy density. In this study, an annular finned-tube PCM-HX design concept was optimized for a load-shifting TES unit to meet the Department of Energy standard for a medium-usage DHW heater using a resistance-capacitance model (RCM) integrated with a Multi-Objective Genetic Algorithm. The optimized design comprised 70 identical annular finned-tube PCM-HX units connected in parallel and utilizing RT62HC as the PCM. A single PCM-HX unit was prototyped and tested in a vertically oriented setup with upward heat transfer fluid (HTF) flow. The hot water supply time was defined based on a cutoff temperature of 51.7°C. The as-designed mass flow rate (1.5 g/s) was tested to assess the performance of the prototyped PCM-HX unit for RCM validation. For the experimental investigation, RTD sensor bundles measured HTF temperature at the PCM-HX inlet and outlet, and a Coriolis flow meter accurately measured the HTF mass flow rate. The simulated discharging power underpredicted the experimental result by about 12%, and the simulated hot water supply time underpredicted the experimental result by approximately 13% for the as-designed mass flow rate (1.5 g/s). The average deviation of the hot water supply temperature between the experimental and RCM results during the complete PCM solidification process was 1.3 K for the as-designed mass flow rate. The overall good agreement between the experimental and RCM results provides confidence that computationally efficient models such as RCM can be utilized for design optimization of PCM-HXs.

42 ENGINEERING↗

National Simulation Analysis of 120V Heat Pump Water Heaters

This presentation details efforts to integrate 120V HPWHs into ResStock, including detailing the required upgrades to the ResStock tools. Example results from this dataset are shown to inform the audience of what will be available in the next release.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Theoretical Analysis of a Single-Stage Gas-Fired Ejector Heat Pump Water Heater

Ejector driven systems have the ability to operate at high efficiencies, utilizing recycled thermal energy as a power source. For a typical ejector heat pump system, the increase of the condenser temperature reduces the coefficient of performance (COP). In addition, if the condenser temperature is higher than the critical temperature, the ejector may not function. In this situation, the condenser temperature must be reduced, and an additional heater will be utilized to heat the production water from the condenser temperature to the desired temperature. In this investigation, a single-stage gas-fired ejector heat pump (EHP) is investigated and thermodynamically modeled in order to optimize the system COP for the purpose of heating water by utilizing the thermal energy from the ambient air. The effects of the high-temperature evaporator (HTE) and low-temperature evaporator (LTE) temperatures on the ejector critical back pressure and the EHP system performance are examined for a HTE temperature range of 120–180 °C and LTE temperatures of 15.5, 17.5, and 19.5 °C. Results show that an optimized COP of the EHP system exists which depends on HTE and LTE temperatures, primary nozzle throat diameters. In addition, it is found that the EHP COP is independent of the ejector COP. From this investigation a maximum EHP COP of 1.31 is able to be achieved for a HTE temperature of 160 °C and a LTE temperature of 19.5 °C with a total heat capacity of 15.98 kW.

Spitzenberger, Jeremy↗

Heat exchanger for solar water heaters

Proposed efficient double-walled heat exchanger prevents contamination of domestic water supply lines and indicates leakage automatically in solar as well as nonsolar heat sources using water as heat transfer medium.

Cash, M.↗

Performance test for a solar water heater

Two reports describe procedures and results of performance tests on domestic solar powered hot water system. Performance tests determine amount of energy collected by system, amount of energy delivered to solar source, power required to operate system and maintain proper tank temperature, overall system efficiency, and temperature distribution in tank.

Source record↗

Solar Water Heater

As a Jet Propulsion Laboratory (JPL) scientist Dr. Eldon Haines studied the solar energy source and solar water heating. He concluded he could build a superior solar water heating system using the geyser pumping principle. He resigned from JPL to develop his system and later form Sage Advance Corporation to market the technology. Haines' Copper Cricket residential system has no moving parts, is immune to freeze damage, needs no roof-mounted tanks, and features low maintenance. It provides 50-90 percent of average hot water requirements. A larger system, the Copper Dragon, has been developed for commercial installations.

Source record↗

Efficient low static-volume water heater

Calrod heating element is surrounded by matrix of fused sintered copper or brass balls, and assembly is then installed in piping of water system. As water flows through matrix, sintered balls cause turbulent flow and heating. Applications include laundromats, laboratories, and photographic labs.

Brown, R. L.↗

Solar Water-Heater Design and Installation

Solar/Water heater system works as follows: Solar--heated air is pumped from collectors through rock bin from top to bottom. Air handler circulates heated air through an air-to-water heat exchanger, which transfers heat to incoming well water. In one application, it may reduce oil use by 40 percent.

Harlamert, P.↗

Optimizing and commercializing the LBNL Grid Burner for AO Smith Storage Water Heater

The purpose of this project was to demonstrate that the LBNL Ring Burner technology can meet the operating, performance, and emission requirements while operating in a residential appliance. This project successfully met all performance targets and enhanced flame stability of the Ring Burner technology.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗