Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “volume visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Reproducibility of 'Intelligent' Contouring of Gross Tumor Volume in Non-Small-Cell Lung Cancer on PET/CT Images Using a Standardized Visual Method

Purpose: Positron emission tomography/computed tomography (PET/CT) is increasingly used for delineating gross tumor volume (GTV) in non-small-cell lung cancer (NSCLC). The methodology for contouring tumor margins remains controversial. We developed a rigorous visual protocol for contouring GTV that uses all available clinical information and studied its reproducibility in patients from a prospective PET/CT planning trial. Methods and Materials: Planning PET/CT scans from 6 consecutive patients were selected. Six 'observers' (two radiation oncologists, two nuclear medicine physicians, and two radiologists) contoured GTVs for each patient using a predefined protocol and subsequently recontoured 2 patients. For the estimated GTVs and axial distances, least-squares means for each observer and for each case were calculated and compared, using the F test and pairwise t-tests. In five cases, tumor margins were also autocontoured using standardized uptake value (SUV) cutoffs of 2.5 and 3.5 and 40% SUV{sub max}. Results: The magnitude of variation between observers was small relative to the mean (coefficient of variation [CV] = 3%), and the total variation (intraclass correlation coefficient [ICC] = 3%). For estimation of superior/inferior (SI), left/right (LR), and anterior/posterior (AP) borders of the GTV, differences between observers were also small (AP, CV = 2%, ICC = 0.4%; LR, CV = 6%, ICC = 2%; SI, CV 4%, ICC = 2%). GTVs autocontoured generated using SUV 2.5, 3.5, and 40% SUV{sub max} differed widely in each case. An SUV contour of 2.5 was most closely correlated with the mean GTV defined by the human observers. Conclusions: Observer variation contributed little to total variation in the GTV and axial distances. A visual contouring protocol gave reproducible results for contouring GTV in NSCLC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

FNETVision: A WAMS Big Data Knowledge Discovery System

With the growing awareness of the power system stability, wide area measurement system (WAMS) has been widely studied and deployed. In WAMS, a phasor data concentrator (PDC) collects and persists the GPS-time-synchronized phasor data from hundreds of phasor measurement units (PMU). Due to the size and complexity of the modern power systems, the number of deployed PMUs has been increasing and their data size becomes increasingly large. The large data volume challenges the analysis, and the knowledge discovery of the measurement data. This paper takes the pioneering distribution level WAMS- the frequency monitoring network FNET/GridEye as an example. It develops an adaptive visualization system- FNETVision to visualize the large-volume WAMS data by interconnection. The case studies suggest, based on the FNETVision system, the system administrator can quickly dig out issues of the FNET system and accordingly pinpoint the cause of these issues.

Wang, Weikang↗

Data Center Facility Monitoring with Physics Aware Approach

U.S. Department of Energy's National Renewable Energy Laboratory (NREL) hosts one of the world's most energy-efficient HPC data centers; this system uses component-level warm-water liquid cooling to efficiently remove heat from the data center and capture it for reuse in the building or rejection to the atmosphere. Given the complexity of this system, building data-driven tools for holistically monitoring and operating the entire data center is a priority for ensuring maximal efficiency and resiliency. In this advanced smart facility, over one million metrics are recorded per minute using state-of-the-art streaming data architecture and software to capture and process the state of the system in real time. Here we detail two efforts to effectively analyze, visualize, and interpret this large volume streaming data. We have developed a novel, flexible system for identifying and visualizing individual metric anomalies and component performance across the data center through automatic metadata extraction and physically-motivated visualization for quick interpretation. Additionally, to directly connect system maintenance to data stream processing we explore a physics informed multi-metric drift and anomaly detection application to detect scale-build up in heat exchangers.

anomaly detection↗

SU-C-17A-01: MRI-Based Radiotherapy Treatment Planning In Pelvis

Purpose: To support radiotherapy dose calculation, synthetic CT (MRCT) image volumes need to represent the electron density of tissues with sufficient accuracy. This study compares CT and MRCT for pelvic radiotherapy. Methods: CT and multi-contrast MRI acquired using T1- based Dixon, T2 TSE, and PETRA sequences were acquired on an IRBapproved protocol patient. A previously published method was used to create a MRCT image volume by applying fuzzy classification on T1- weighted and calculated water image volumes (air and fluid voxels were excluded using thresholds applied to PETRA and T2-weighted images). The correlation of pelvic bone intensity between CT and MRCT was investigated. Two treatment plans, based on CT and MRCT, were performed to mimic treatment for: (a) pelvic bone metastasis with a 16MV parallel beam arrangement, and (b) gynecological cancer with 6MV volumetric modulated arc therapy (VMAT) using two full arcs. The CT-calculated fluence maps were used to recalculate doses using the MRCT-derived density grid. The dose-volume histograms and dose distributions were compared. Results: Bone intensities in the MRCT volume correlated linearly with CT intensities up to 800 HU (containing 96% of the bone volume), and then decreased with CT intensity increase (4% volume). There was no significant difference in dose distributions between CT- and MRCTbased plans, except for the rectum and bladder, for which the V45 differed by 15% and 9%, respectively. These differences may be attributed to normal and visualized organ movement and volume variations between CT and MR scans. Conclusion: While MRCT had lower bone intensity in highly-dense bone, this did not cause significant dose deviations from CT due to its small percentage of volume. These results indicate that treatment planning using MRCT could generate comparable dose distributions to that using CT, and further demonstrate the feasibility of using MRI-alone to support Radiation Oncology workflow. NIH R01EB016079.

60 APPLIED LIFE SCIENCES↗

Pretreatment Predictors of Adverse Radiation Effects After Radiosurgery for Arteriovenous Malformation

Purpose: To identify vascular and dosimetric predictors of symptomatic T2 signal change and adverse radiation effects after radiosurgery for arteriovenous malformation, in order to define and validate preexisting risk models. Methods and Materials: A total of 125 patients with arteriovenous malformations (AVM) were treated at our institution between 2005 and 2009. Eighty-five patients have at least 12 months of clinical and radiological follow-up. Any new-onset headaches, new or worsening seizures, or neurological deficit were considered adverse events. Follow-up magnetic resonance images were assessed for new onset T2 signal change and the volume calculated. Pretreatment characteristics and dosimetric variables were analyzed to identify predictors of adverse radiation effects. Results: There were 19 children and 66 adults in the study cohort, with a mean age of 34 (range 6-74). Twenty-three (27%) patients suffered adverse radiation effects (ARE), 9 patients with permanent neurological deficit (10.6%). Of these, 5 developed fixed visual field deficits. Target volume and 12 Gy volume were the most significant predictors of adverse radiation effects on univariate analysis (p < 0.001). Location and cortical eloquence were not significantly associated with the development of adverse events (p = 0.12). No additional vascular parameters were identified as predictive of ARE. There was a significant target volume threshold of 4 cm{sup 3}, above which the rate of ARE increased dramatically. Multivariate analysis target volume and the absence of prior hemorrhage are the only significant predictors of ARE. The volume of T2 signal change correlates to ARE, but only target volume is predictive of a higher volume of T2 signal change. Conclusions: Target volume and the absence of prior hemorrhage is the most accurate predictor of adverse radiation effects and complications after radiosurgery for AVMs. A high percentage of permanent visual field defects in this series suggest the optic radiation is a critical radiosensitive structure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Visualization of Jet Impingement and Ignition in a Piston-Cylinder Chamber

The transportation sector accounts for almost a third of the United States' energy consumption. We are developing predictive simulations of the complex in-cylinder processes of internal combustion engines to improve performance and decrease pollutant emissions. We provide a first look at the jet impingement and ignition inside a piston-cylinder chamber using volume rendering. Through the visualization, we constructed a complete 3D picture of the jet impingement on the piston-bowl walls leading to the formation of pockets of auto-ignition of the fuel-air mixture. These auto-ignition pockets subsequently lead to flame stabilization, releasing the chemical energy for conversion to useful work. A detailed physical picture of flame stabilization, as provided by the visualization techniques presented in this study, help in the design of next-generation internal combustion engines.

91 SC - Advanced Scientific Computing Reseach (ASC↗

Volume-conserving trans-cis isomerization pathways in photoactive yellow protein visualized by picosecond X-ray crystallography

Trans-to-cis isomerization, the key reaction in photoactive proteins, usually cannot occur through the standard one-bond-flip mechanism. Owing to spatial constraints imposed by a protein environment, isomerization probably proceeds through a volume-conserving mechanism in which highly choreographed atomic motions are expected, the details of which have not yet been observed directly. Here we employ time-resolved X-ray crystallography to visualize structurally the isomerization of the p-coumaric acid chromophore in photoactive yellow protein with a time resolution of 100 ps and a spatial resolution of 1.6 Å. The structure of the earliest intermediate (I T ) resembles a highly strained transition state in which the torsion angle is located halfway between the trans- and cis-isomers. The reaction trajectory of IT bifurcates into two structurally distinct cis intermediates via hula-twist and bicycle-pedal pathways. The bifurcating reaction pathways can be controlled by weakening the hydrogen bond between the chromophore and an adjacent residue through E46Q mutation, which switches off the bicycle-pedal pathway.

Jung, Yang Ouk↗

SU-E-J-196: New Visualization Methods for Longitudinal MRI Registrations and Segmentations

Purpose: To develop visualization techniques to facilitate easy assessment of (a) registration and (b) tracking volumetric changes in structures during radiation therapy from MRI. Method: The frequently used method for visualizing registrations between scans is a multi-color overlay technique or deformation vector fields. However, the overlay technique is unintuitive and does not help to appreciate the quality of registration particularly when the registration mismatches are not very large. Similarly, the deformation fields give an indication of extent of deformation but do not help to assess the differences in registration. We present a mirroring and edge-augmented mirroring technique that places the fixed and moving image next to each other and allows the user to quickly assess the small differences in registration. Next, we present a volumetric intersection based 3D model to visualize the changes in diseased lymph node volumes in head and neck cancer. 3D model-based visualization provides more information about the location-specific changes in volume rather than the simplistic one dimensional information obtained from 2D plot of nodal volume changes. Result: We show results comparing our approach with the standard colorbased overlay method for comparing registrations of intra-patient registrations using T2-MRI. Upon comparing the mirroring technique with the color-overlay, one can more easily appreciate the differences in registration. Adding edge-based mirroring seems to further assist in evaluating the registration. Our approach for viewing registrations seems to be more intuitive and easy to use in order to help assess the quality of registration compared to color-based overlays. Similarly, the change volumetric model together with a 2D plot reveals more information including the locations undergoing changes and responding to treatment. Conclusions: Better approaches are necessary for assessing the quality of registrations and changes in diseased structures over time. Our approach presents some novel visualization solutions for registration and segmentation.

60 APPLIED LIFE SCIENCES↗

Fiber Uncertainty Visualization for Bivariate Data With Parametric and Nonparametric Noise Models

Visualization and analysis of multivariate data and their uncertainty are top research challenges in data visualization. Constructing fiber surfaces is a popular technique for multivariate data visualization that generalizes the idea of level-set visualization for univariate data to multivariate data. Here, in this paper, we present a statistical framework to quantify positional probabilities of fibers extracted from uncertain bivariate fields. Specifically, we extend the state-of-the-art Gaussian models of uncertainty for bivariate data to other parametric distributions (e.g., uniform and Epanechnikov) and more general nonparametric probability distributions (e.g., histograms and kernel density estimation) and derive corresponding spatial probabilities of fibers. In our proposed framework, we leverage Green's theorem for closed-form computation of fiber probabilities when bivariate data are assumed to have independent parametric and nonparametric noise. Additionally, we present a nonparametric approach combined with numerical integration to study the positional probability of fibers when bivariate data are assumed to have correlated noise. For uncertainty analysis, we visualize the derived probability volumes for fibers via volume rendering and extracting level sets based on probability thresholds. We present the utility of our proposed techniques via experiments on synthetic and simulation datasets.

97 MATHEMATICS AND COMPUTING↗

3D Stereoscopic Visualization of Fenestrated Stent Grafts

The purpose of this study was to present a technique of stereoscopic visualization in the evaluation of patients with abdominal aortic aneurysm treated with fenestrated stent grafts compared with conventional 2D visualizations. Two patients with abdominal aortic aneurysm undergoing fenestrated stent grafting were selected for inclusion in the study. Conventional 2D views including axial, multiplanar reformation, maximum-intensity projection, and volume rendering and 3D stereoscopic visualizations were assessed by two experienced reviewers independently with regard to the treatment outcomes of fenestrated repair. Interobserver agreement was assessed with Kendall's W statistic. Multiplanar reformation and maximum-intensity projection visualizations were scored the highest in the evaluation of parameters related to the fenestrated stent grafting, while 3D stereoscopic visualization was scored as valuable in the evaluation of appearance (any distortions) of the fenestrated stent. Volume rendering was found to play a limited role in the follow-up of fenestrated stent grafting. 3D stereoscopic visualization adds additional information that assists endovascular specialists to identify any distortions of the fenestrated stents when compared with 2D visualizations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MPI-hybrid Parallelism for Volume Rendering on Large, Multi-core Systems

This work studies the performance and scalability characteristics of"hybrid'" parallel programming and execution as applied to raycasting volume rendering -- a staple visualization algorithm -- on a large, multi-core platform. Historically, the Message Passing Interface (MPI) has become the de-facto standard for parallel programming and execution on modern parallel systems. As the computing industry trends towards multi-core processors, with four- and six-core chips common today and 128-core chips coming soon, we wish to better understand how algorithmic and parallel programming choices impact performance and scalability on large, distributed-memory multi-core systems. Our findings indicate that the hybrid-parallel implementation, at levels of concurrency ranging from 1,728 to 216,000, performs better, uses a smaller absolute memory footprint, and consumes less communication bandwidth than the traditional, MPI-only implementation.

97 MATHEMATICS AND COMPUTING↗

CT Imaging for Gynecological HDR: Tools and Tricks

Computerized tomography (CT)-assisted treatment planning for high-dose-rate (HDR) gynecological cancer treatments allows for better structure visualization and dose-volume histogram analysis definition. Problems associated with CT imaging are addressed. These pitfalls include the potential for multiple patient transfers and movement between applicator insertion, simulation, and treatment. Applicator CT imaging artifacts are also discussed. A modified transport table and a machined connection for a commercially available non-CT-compatible tandem and a CT-compatible ring applicator are described. These 2 modifications provide a safe and reliable method to utilize the advantages of CT imaging for gynecological HDR treatments.

61 RADIATION PROTECTION AND DOSIMETRY↗

A 2.5d Yolo-Based Fusion Algorithm for 3d Localization Of Cells

Advances in microscopy techniques such as lattice-light-sheet, confocal, two-photon, and electron microscopy have enabled the visualization of 3D image volumes of tightly packed cells, extracellular structures in tissues, organelles, and subcellular components inside cells. These images sampled by 2D projections are often not accurately interpreted even by human experts. As a use case we focus on 3D image volumes of tightly packed nuclei in brain tissue. Due to out-of-plane excitation and low resolution in the z-axis, non-overlapping cells appear as overlapping 3D volumes and make detecting individual cells challenging. On the other hand, running 3D detection algorithms is computationally expensive and infeasible for large datasets. In addition, most existing 3D algorithms are designed to extract 3D objects by identifying the depth in the 2D images. In this work, we propose a YOLO-based 2.5D fusion algorithm for 3D localization of individual cells in densely packed volumes of nuclei. The proposed method fuses 2D detection of nuclei in sagittal, coronal, and axial planes and predicts six coordinates of the 3D bounding cubes around the detected 3D cells. Promising results were obtained on multiple examples of synthetic dense volumes of nuclei imitating confocal microscopy experimental datasets.

Ziabari, Amir↗

WE-A-BRD-00: MR Basics II

Ever since its introduction as a diagnostic imaging modality over 30 years ago, the radiation therapy community has acknowledged the utility of MR imaging as a tool for not only improved visualization of the target volume but also for demarcation of adjacent organs at risk. However, the adaptation of MR imaging in radiation oncology has, until recently been slow due in large part to the inability to image radiation therapy patients in their treatment position. With the introduction of so-called wide bore high field MR scanners, multi element flexible receive only RF coils, high performance imaging gradients and a range of volumetric imaging sequences it is now possible to obtain both high resolution and high signal-to-noise ratio images of in-treatment radiation therapy patients within clinically feasible imaging times. As a Result, there is renewed interest in the use of MR imaging for radiation oncology treatment planning that is being translated into physical siting and integration of these systems into radiation oncology departments. As MR imaging expands into the radiation oncology domain there is a significant and unmet need for radiation therapy physicists to become educated regarding the strengths, limitations and technical challenges associated with MR imaging. The purpose of this presentation is to address this need by providing an educational overview of the techniques and challenges associated with MR imaging of patients for radiation therapy treatment planning. As such this presentation will: 1) describe the fundamental differences between imaging of patients for diagnostic and therapeutic purposes (i.e. radiation therapy planning), 2) describe most commonly used imaging sequences and contrasts for identification of disease for radiation planning, 3) identify the most common sources of image distortion and techniques to reduce their effect on spatial fidelity of the MR data, 4) describe the effects of motion and methods to quantify/correct it, and 5) identify emergent techniques for performing MR only treatment simulation. Upon completion attendees will have a working understanding of the basic methodologies associated with MR imaging in radiation oncology, the unique technical challenges imposed by MR imaging in the treatment position and techniques to address these. Learning Objectives: 1. Understand the differences between MR imaging for diagnostic imaging and for radiation therapy planning. 2. Identify the most common sources of distortion and artifacts and simple methods to correct them. 3. Understand the challenges with MR imaging in the therapy treatment position and appropriate techniques to address them.

60 APPLIED LIFE SCIENCES↗

WE-A-BRD-01: MR Imaging for Treatment Planning: What Every Physicist Should Know

Ever since its introduction as a diagnostic imaging modality over 30 years ago, the radiation therapy community has acknowledged the utility of MR imaging as a tool for not only improved visualization of the target volume but also for demarcation of adjacent organs at risk. However, the adaptation of MR imaging in radiation oncology has, until recently been slow due in large part to the inability to image radiation therapy patients in their treatment position. With the introduction of so-called wide bore high field MR scanners, multi element flexible receive only RF coils, high performance imaging gradients and a range of volumetric imaging sequences it is now possible to obtain both high resolution and high signal-to-noise ratio images of in-treatment radiation therapy patients within clinically feasible imaging times. As a Result, there is renewed interest in the use of MR imaging for radiation oncology treatment planning that is being translated into physical siting and integration of these systems into radiation oncology departments. As MR imaging expands into the radiation oncology domain there is a significant and unmet need for radiation therapy physicists to become educated regarding the strengths, limitations and technical challenges associated with MR imaging. The purpose of this presentation is to address this need by providing an educational overview of the techniques and challenges associated with MR imaging of patients for radiation therapy treatment planning. As such this presentation will: 1) describe the fundamental differences between imaging of patients for diagnostic and therapeutic purposes (i.e. radiation therapy planning), 2) describe most commonly used imaging sequences and contrasts for identification of disease for radiation planning, 3) identify the most common sources of image distortion and techniques to reduce their effect on spatial fidelity of the MR data, 4) describe the effects of motion and methods to quantify/correct it, and 5) identify emergent techniques for performing MR only treatment simulation. Upon completion attendees will have a working understanding of the basic methodologies associated with MR imaging in radiation oncology, the unique technical challenges imposed by MR imaging in the treatment position and techniques to address these. Learning Objectives: 1. Understand the differences between MR imaging for diagnostic imaging and for radiation therapy planning. 2. Identify the most common sources of distortion and artifacts and simple methods to correct them. 3. Understand the challenges with MR imaging in the therapy treatment position and appropriate techniques to address them.

60 APPLIED LIFE SCIENCES↗

Improving Scientific Data Analysis Through Multi-touch Enabled Interactive Data Visualization with Applications to Neutron Science

Scientific data analysis is an inherently exploratory process that requires flexible human interaction with data visualization and anal- ysis tools. In this paper, we describe challenges in neutron scattering data analysis and present our approach for allowing more effective human interaction. In addition to multi-touch enabled data visualiza- tion techniques, we describe color scale enhancements, layouts, and visual analytics approaches for 3D volume slicing. Since challenges in neutron science are echoed in most scientific fields, we generalize the project objective and present a case for bridging the gap between the latest advances in interactive data visualization and practical scientific scenarios where new critical knowledge is buried in large volumes of complex data.

Steed, Chad↗

Radiation Dose–Dependent Hippocampal Atrophy Detected With Longitudinal Volumetric Magnetic Resonance Imaging

Purpose: After radiation therapy (RT) to the brain, patients often experience memory impairment, which may be partially mediated by damage to the hippocampus. Hippocampal sparing in RT planning is the subject of recent and ongoing clinical trials. Calculating appropriate hippocampal dose constraints would be improved by efficient in vivo measurements of hippocampal damage. In this study we sought to determine whether brain RT was associated with dose-dependent hippocampal atrophy. Methods and Materials: Hippocampal volume was measured with magnetic resonance imaging (MRI) in 52 patients who underwent fractionated, partial brain RT for primary brain tumors. Study patients had high-resolution, 3-dimensional volumetric MRI before and 1 year after RT. Images were processed using software with clearance from the US Food and Drug Administration and Conformité Européene marking for automated measurement of hippocampal volume. Automated results were inspected visually for accuracy. Tumor and surgical changes were censored. Mean hippocampal dose was tested for correlation with hippocampal atrophy 1 year after RT. Average hippocampal volume change was also calculated for hippocampi receiving high (>40 Gy) or low (<10 Gy) mean RT dose. A multivariate analysis was conducted with linear mixed-effects modeling to evaluate other potential predictors of hippocampal volume change, including patient (random effect), age, hemisphere, sex, seizure history, and baseline volume. Statistical significance was evaluated at α = 0.05. Results: Mean hippocampal dose was significantly correlated with hippocampal volume loss (r=−0.24, P=.03). Mean hippocampal volume was significantly reduced 1 year after high-dose RT (mean −6%, P=.009) but not after low-dose RT. In multivariate analysis, both RT dose and patient age were significant predictors of hippocampal atrophy (P<.01). Conclusions: The hippocampus demonstrates radiation dose–dependent atrophy after treatment for brain tumors. Quantitative MRI is a noninvasive imaging technique capable of measuring radiation effects on intracranial structures. This technique could be investigated as a potential biomarker for development of reliable dose constraints for improved cognitive outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗