Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage temperature frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Recent Stirling Conversion Technology Developments and Operational Measurements

Under contract to the Department of Energy (DOE), Lockheed Martin Space Systems Company (LMSSC) has been developing the Advanced Stirling Radioisotope Generator (ASRG). The use of Stirling technology introduces a four-fold increase in conversion efficiency over Radioisotope Thermoelectric Generators (RTGs), and thus the ASRG in an attractive power system option for future science missions. In August of 2008, the ASRG engineering unit (EU) was delivered to NASA Glenn Research Center (GRC). The engineering unit design resembles that of a flight unit, with the exception of electrical heating in place of a radioisotope source. Prior to delivery, GRC personnel prepared a test station continuous, unattended operation of the engineering unit. This test station is capable of autonomously monitoring the unit's safe operation and recording. , .. , .... performance data. Generator parameters recorded include temperatures, electrical power output, and thelmal power input. Convertor specific parameters are also recorded such as alternator voltage, current, piston amplitude, and frequency. Since November 2008, the ASRG EU has accumulated over 4,000 hours of operation. Initial operation was conducted using the AC bus control method in lieu of the LMSSC active power factor connecting controller. Operation on the LMSSC controller began in February 2009. This paper discusses the entirety of ASRG EU operation thus far, as well as baseline performance data at GRC and LMSSC, and comparison of performance using each control method.

Oriti, Salvatore↗

Lightweight, high-frequency transformers

The 25-kVA space transformer was developed under contract by Thermal Technology Laboratory, Buffalo, N. Y. The NASA Lewis transformer technology program attempted to develop the baseline technology. For the 25-kVA transformer the input voltage was chosen as 200 V, the output voltage as 1500 V, the input voltage waveform as square wave, the duty cycle as continuous, the frequency range (within certain constraints) as 10 to 40 kHz, the operating temperatures as 85 deg. and 130 C, the baseplate temperature as 50 C, the equivalent leakage inductance as less than 10 micro-h, the operating environment as space, and the life expectancy as 10 years. Such a transformer can also be used for aircraft, ship and terrestrial applications.

Schwarze, G. E.↗

Aquarius Digital Processing Unit

Three documents provide information on a digital processing unit (DPU) for the planned Aquarius mission, in which a radiometer aboard a spacecraft orbiting Earth is to measure radiometric temperatures from which data on sea-surface salinity are to be deduced. The DPU is the interface between the radiometer and an instrument-command-and-data system aboard the spacecraft. The DPU cycles the radiometer through a programmable sequence of states, collects and processes all radiometric data, and collects all housekeeping data pertaining to operation of the radiometer. The documents summarize the DPU design, with emphasis on innovative aspects that include mainly the following: a) In the radiometer and the DPU, conversion from analog voltages to digital data is effected by means of asynchronous voltage-to-frequency converters in combination with a frequency-measurement scheme implemented in field-programmable gate arrays (FPGAs). b) A scheme to compensate for aging and changes in the temperature of the DPU in order to provide an overall temperature-measurement accuracy within 0.01 K includes a high-precision, inexpensive DC temperature measurement scheme and a drift-compensation scheme that was used on the Cassini radar system. c) An interface among multiple FPGAs in the DPU guarantees setup and hold times.

Forgione, Joshua↗

Fiber-optic sensors for aerospace electrical measurements: An update

Fiber-optic sensors are being developed for electrical current, voltage, and power measurements in aerospace applications. These sensors are presently designed to cover ac frequencies from 60 Hz to 20 kHz. The current sensor, based on the Faraday effect in optical fiber, is in advanced development after some initial testing. Concentration is on packaging methods and ways to maintain consistent sensitivity with changes in temperature. The voltage sensor, utilizing the Pockels effect in a crystal, has excelled in temperature tests. This paper reports on the development of these sensors, the results of evaluation, improvements now in progress, and the future direction of the work.

Patterson, Richard L.↗

Wide Temperature Magnetization Characteristics of Transverse Magnetically Annealed Amorphous Tapes for High Frequency Aerospace Magnetics

100 kHz magnetization properties of sample transverse magnetically annealed, cobalt-based amorphous and iron-based nanocrystalline tape wound magnetic cores are presented over the temperature range of -150 C to 150 C, at selected values of B(sub peak). Frequency resolved characteristics are given over the range of 50 kHz to 1 MHz, but at B(sub peak) = 0.1 T and 50 C only. Basic exciting winding current and induced voltage data were taken on bare toroidal cores, in a standard type measurement setup. A linear permeability model, which represents the core by a parallel L-R circuit, is used to interpret and present the magnetization characteristics and several figures of merit applicable to inductor materials are reviewed. The 100 kHz permeability thus derived decreases with increasing temperature for the Fe-based, nanocrystalline material, but increases roughly linearly with temperature for the two Co-based materials, as long as B(sub peak) is sufficiently low to avoid saturation effects. Due to the high permeabilities, rather low values of the 'quality factor' Q, from about 20 to below unity, were obtained over the frequency range of 50 kHz to 1 MHz (50 C, B(sub peak) = 0.1 T). Therefore these cores must be gapped in order to make up high Q or high current inductors. However, being rugged, low core loss materials with flat B-H loop characteristics, they may provide new solutions to specialty inductor applications.

Niedra, Janis M.↗

Altus small button cell performance

Results of testing performed on Altus lithium thionyl chloride cells are presented. The test plan followed simulates the mine environment. It involves nondestructive testing, ruggedness testing and destructive testing. The nondestructive testing involves open circuit voltage measurements initially on all the cells, alternating current resistance measurements initially on all the cells and closed circuit voltage pulses, 20s on and 20s through 1000, 100, 10 and 1 ohms at temperatures of -54 to 71 C. The ruggedness testing involves low frequency vibration, high frequency vibration, and two-phase water entry shock at temperatures of -54, 25 and 71 C. It also involves thermal shock tests.

Freeman, C.↗

Fiber-optic sensors for aerospace electrical measurements - An update

The authors report the progress made on the development of aerospace current and voltage sensors which use fiber-optic and optical sensing heads. These sensors are presently designed to cover ac frequencies from 60 Hz to 20 kHz. The current sensor, based on the Faraday effect in optical fiber, is in advanced development after some initial testing. The emphasis is on packaging methods and ways to maintain consistent sensitivity with changes in temperature. The voltage sensor, utilizing the Pockels effect in a crystal, has excelled in temperature tests. The authors report on the development of these sensors. The authors also relate the technology used in the sensors, the results of evaluation, improvements being made, and the future direction of the work.

Patterson, Richard L.↗

Performance of Ge:Ga far infrared detectors

A systematic study was carried out of the properties of Ge:Ga photoconductive infrared detectors for wavelengths approx. 100 micron. The detectors studied were made from Ge:Ga with acceptor concentration N sub A approx. 2 x 10 exp 14/cu cm with both low compensation (10 exp -2) and ultralow compensation (10 exp -4). Noise measurements have been made as a function of background photon rate, bias voltage, and chopping frequency. Detective quantum efficiencies approaching unity have been observed over a side range of experimental parameters. Photocurrent has been measured as a function of voltage and temperature. Hall mobility and lifetime have been measured to determine their effect on detector properties. A small potential drop has been observed in nominally ohmic contacts produced by implantation of B ions.

Hueschen, M. R.↗

Magnetic and Langmuir Probe Measurements on the Plasmoid Thruster Experiment (PTX)

The Plasmoid Thruster Experiment (PTX) operates by inductively producing plasmoids in a conical theta-pinch coil and ejecting them at high velocity. A plasmoid is a plasma with an imbedded closed magnetic field structure. The shape and magnetic field structure of the translating plasmoids have been measured with of an array of magnetic field probes. Six sets of two B-dot probes were constructed for measuring B(sub z) and B(sub theta), the axial and azimuthal components of the magnetic field. The probes are wound on a square G10 form, and have an average (calibrated) NA of 9.37 x l0(exp -5) square meters, where N is the number of turns and A is the cross-sectional area. The probes were calibrated with a Helmholtz coil, driven by a high-voltage pulser to measure NA, and by a signal generator to determine the probe's frequency response. The plasmoid electron number density n(sub e) electron temperature T(sub e), and velocity ratio v/c(sub m), (where v is the bulk plasma flow velocity and c(sub m), is the ion thermal speed) have also been measured with a quadruple Langmuir probe. The Langmuir probe tips are 10 mm long, 20-mil diameter stainless steel wire, housed in a 6-inch long 4-bore aluminum rod. Measurements on PTX with argon and hydrogen from the magnetic field probes and quadruple Langmuir probe will be presented in this paper.

Koelfgen, Syri J.↗

Comparison of Thermal Coefficients for Two Microwave Detectors

Laboratory measurements were performed to compare the thermal coefficients of two microwave detectors that might be used for direct detection in L-band radiometers. In particular it was desired to compare the performance of a new-technology flash ADC (analog-to-digital converter) against that of an older-technology diode detector in series with a VFC (voltage-to-frequency converter). The outputs of two state-of-the-art detectors were recorded as a constant 1.414-GHz signal was input and the physical temperatures of the detectors were varied over a range of 10 C. As a further experiment, each detector was tested with a noise diode source and with a sine wave synthesizer source. Thermal coefficients were computed in terms of W/C and in terms of ppt/C at nominal operating temperatures reasonable for the individual devices. Finally, thermal coefficients were calculated in K/C to indicate the change in brightness temperature seen by a theoretical sea surface salinity radiometer employing each detector. The K/C for the flash ADC was determined to be about 2.8 times that of the diode/VFC. Different reactions of the ADC to a noise input and a sine wave input indicated that ADC tests for radiometric purposes, such as this one, should be performed using a noise input.

Mackenzie, Anne I.↗

Advanced Electrical Materials and Components Being Developed

All aerospace systems require power management and distribution (PMAD) between the energy and power source and the loads. The PMAD subsystem can be broadly described as the conditioning and control of unregulated power from the energy source and its transmission to a power bus for distribution to the intended loads. All power and control circuits for PMAD require electrical components for switching, energy storage, voltage-to-current transformation, filtering, regulation, protection, and isolation. Advanced electrical materials and component development technology is a key technology to increasing the power density, efficiency, reliability, and operating temperature of the PMAD. The primary means to develop advanced electrical components is to develop new and/or significantly improved electronic materials for capacitors, magnetic components, and semiconductor switches and diodes. The next important step is to develop the processing techniques to fabricate electrical and electronic components that exceed the specifications of presently available state-of-the-art components. The NASA Glenn Research Center's advanced electrical materials and component development technology task is focused on the following three areas: 1) New and/or improved dielectric materials for the development of power capacitors with increased capacitance volumetric efficiency, energy density, and operating temperature; 2) New and/or improved high-frequency, high-temperature soft magnetic materials for the development of transformers and inductors with increased power density, energy density, electrical efficiency, and operating temperature; 3) Packaged high-temperature, high-power density, high-voltage, and low-loss SiC diodes and switches.

Schwarze, Gene E.↗

Potential damage to DC superconducting magnets due to the high frequency electromagnetic waves

Experimental data are presented in support of the hypothesis that a dc superconducting magnet coil does not behave strictly as an inductor, but as a complicated electrodynamic device capable of supporting electromagnetic waves. Travel times of nanosecond pulses and evidence of sinusoidal standing waves were observed on a prototype four-layer solenoidal coil at room temperature. Ringing observed during switching transients appears as a sequence of multiple reflected square pulses whose durations are related to the layer lengths. With sinusoidal excitation of the coil, the voltage amplitude between a pair of points on the coil exhibits maxima at those frequencies such that the distance between these points is an odd multiple of half wavelength in free space. Evidence indicates that any disturbance, such as that resulting from switching or sudden fault, initiates multiple reflections between layers, thus raising the possibility for sufficiently high voltages to cause breakdown.

Gabriel, G. J.↗

The impact of hot-press conditions on the durability of polymer electrolyte membrane fuel cells

The proton exchange membrane integrity can be compromised during hot-press fabrication of membrane electrode assemblies (MEAs) causing premature cell failures during operation. In this work, infrared (IR) thermography was used as a diagnostic tool to spatially visualize hydrogen (H 2 ) crossover and identify process-induced-membrane irregularities (PIMs). These irregularities were identified as seed locations for MEA failures. Fine tuning of hot-press conditions was used to mitigate premature cell failures informed by accelerated stress testing (AST). The impact of PIMs on the initial performance, high-frequency resistances, open-circuit voltage, and H 2 crossover are reported. Nafion XL and 212 membranes, hot-pressed with a force of 16 kg/cm 2 and temperature of 120°C, were found to be consistently irregularity-free. Irregularity-free MEAs using Nafion 211, 212, and XL membranes demonstrated AST lifetime improvements of 58, 64 and 400%, respectively, compared to those fabricated with non-optimized conditions. In conclusion, this work highlights the importance of fabrication parameters on premature cell failures.

08 HYDROGEN↗

LaF3 infrared detector

A class of infrared detectors is proposed, and experimental results are presented for a prototype device. The material used is LaF3, an ionic conductor with a capacitance that varies exponentially with temperature. The detectivity of a prototype detector is estimated from measured signal voltages and incident power, and a Johnson noise voltage is calculated from the measured resistance. At a modulation frequency of 20 Hz, the estimated detectivity is about 2 million cm/sq root Hz/W. For the parameters characterizing this device, the estimated detectivity is consistent with a theoretical prediction. The theory further predicts an optimum detectivity of about 1 billion cm/sq root Hz/W for much thinner devices than the prototypes.

Sher, A.↗

A Study of the Measurement of Seebeck Coefficient of SiGe

In 1821 German Physicist Thomas J. Seebeck discovered that heat could be converted into electricity when a temperature difference was applied across two points on a material. Theoretically, the generated voltage has a directly proportional relationship with the temperature difference. This relationship is the Seebeck coefficient that scientists always referred to when determining the efficiency of a thermoelectricity convention. In our experiments, however, hysteresis loops appeared when we plotted voltage against temperature difference, and the measured Seebeck appeared differently when the measurements were run under vacuum, air, and helium gas. Measurements were done by using a low-frequency AC measuring method. By simulating the experimental setup into a; thermal circuit, we found that the loop and inconsistency in measuring Seebeck coefficient could be explained by studying the behaviors of a RC circuit in a thermal sense. Under vacuum, the gap of the hysteresis loop can be largely eliminated if the time period of the temperature difference increased up to 4800s. The trend of the variations in measuring Seebeck coefficients in different environments can also be predicted by using different thermal circuit models.

Heung, King Yi↗

An Arbitrary Time Interval Generator Base on Vernier Clocks with 0.67 ps Adjustable Steps Implemented in FPGA

In TDC testing and timing system implementations, it is often necessary to generate signal pulses with finely adjustable time intervals. In delay cell–based schemes, the adjustment resolution is constrained by the propagation delay of the cells—typically 15–20 ps per step—and is sensitive to temperature and supply voltage variations. This document presents a fully digital approach that uses two vernier clocks, generated by two stages of cascaded phase-locked loops (PLLs) with a slight frequency difference, to achieve adjustable timing intervals through accumulated phase differences. The scheme was validated on two families of low-cost FPGA devices, achieving adjustable step sizes of 0.67 ps and 0.97 ps.

Wu, Jin-yuan [Fermilab] (ORCID:0000000344329521)↗

Advanced high frequency partial discharge measuring system

This report explains the Advanced Partial Discharge Measuring System in ASU's High Voltage Laboratory and presents some of the results obtained using the setup. While in operation an insulation is subjected to wide ranging temperature and voltage stresses. Hence, it is necessary to study the effect of temperature on the behavior of partial discharges in an insulation. The setup described in this report can be used to test samples at temperatures ranging from -50 C to 200 C. The aim of conducting the tests described herein is to be able to predict the behavior of an insulation under different operating conditions in addition to being able to predict the possibility of failure.

Karady, George G.↗

Magnetic and Langmuir Probe Measurements on the Plasmoid Thruster Experiment (PTX)

The Plasmoid Thruster Experiment (PTX) operates by inductively producing plasmoids in a conical theta-pinch coil and subsequently ejecting them at high velocity. An overview of PTX is described in a companion paper. The shape and magnetic field structure of the translating plasmoids will be measured with of an array of inductive magnetic field probes. Six sets of two B-dot probes (for a total of twelve probes) have been constructed for measuring B(sub z) and B(sub theta), the axial and azimuthal components of the magnetic field. The probes were calibrated with a Helmholtz coil, driven alternately by a high-voltage pulser or a signal generator. The probes are wound on a G-10 form, and have an average (calibrated) NA of 9.37 x 10(exp -5) square meters, where N is the number of turns and A is cross-sectional area. The frequency response of the probes was measured over the range from 1 kHz to 10 MHZ. The electron number density n(sub e), electron temperature T(sub e) and velocity v will be determined from measurements taken with a quadruple Langmuir probe, situated in the exhaust chamber. Three of the four probes on the quadruple probe sample the current-voltage characteristic, and from this yield measurements of T(sub e) and n(sub e). The fourth probe provides a measurement of plasma flow velocity. A 6-inch long alumina rod, hollowed with four holes to house the probe wires, is being used to construct the quadruple probe. A variety of propellants will be used, including hydrogen, nitrogen and argon. From the measurements of the plasmoid mass, density, temperature, and velocity, the basic propulsion characteristics of PTX will be evaluated.

Koelfgen, Syri J.↗