Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Transmission and Distribution Real-Time Analysis Software for Monitoring and Control: Design and Simulation Testing

The US electric grid is facing operational, stability, and security challenges. Transmission system operators need some measure of visibility into distribution system renewable generation. Distribution system generation needs to support transmission system voltage. The grid is experiencing an expansion in measurement systems. How to take full advantage of this expansion and defend against attacks, both cyber and physical, poses additional challenges. This paper introduces software designed to meet these challenges. At the center of the software is an Integrated System Model (ISM) that spans from transmission to secondary distribution. The ISM is employed in real-time abnormality detection, voltage stability forecasting, and multi-mode control. The software architecture along with selected analysis modules is presented. Testing results are presented for: 1—attacks on utility infrastructure; 2—energy savings from optimal control; 3—distribution system control response during a low voltage transmission system event; 4—cyber-attacks on PV inverters, where physical inverters are used in hardware-in-the-simulation-loop studies. Contributions of this work include real-time analysis that spans from three-phase transmission through secondary distribution; an approach for detecting abnormalities that employs measurements from three independent measurement systems; and a multi-mode distribution system control that responds to cyber-attacks, physical attacks, equipment failures, and transmission system needs.

14 SOLAR ENERGY↗

Steric Effect Tuned Ion Solvation Enabling Stable Cycling of High-Voltage Lithium Metal Battery

1,2-Dimethoxyethane (DME) is a common electrolyte solvent for lithium metal batteries. Various DME-based electrolyte designs have improved long-term cyclability of high-voltage full cells. However, insufficient Coulombic efficiency at the Li anode and poor high-voltage stability remain a challenge for DME electrolytes. Here, we report a molecular design principle that utilizes a steric hindrance effect to tune the solvation structures of Li + ions. In this work, we hypothesized that by substituting the methoxy groups on DME with larger-sized ethoxy groups, the resulting 1,2-diethoxyethane (DEE) should have a weaker solvation ability and consequently more anion-rich inner solvation shells, both of which enhance interfacial stability at the cathode and anode. Experimental and computational evidence indicates such steric-effect-based design leads to an appreciable improvement in electrochemical stability of lithium bis(fluorosulfonyl)imide (LiFSI)/DEE electrolytes. Under stringent full-cell conditions of 4.8 mAh cm –2 NMC811, 50 μm thin Li, and high cutoff voltage at 4.4 V, 4 M LiFSI/DEE enabled 182 cycles until 80% capacity retention while 4 M LiFSI/DME only achieved 94 cycles. This work points out a promising path toward the molecular design of non-fluorinated ether-based electrolyte solvents for practical high-voltage Li metal batteries.

25 ENERGY STORAGE↗

Island Power Systems With High Levels of Inverter-Based Resources: Stability and Reliability Challenges

As many island power systems seek to integrate high levels of renewable energy, they face new challenges on top of the existing difficulties of operating an isolated grid. With their drastically declining cost, variable renewables, such as wind and photovoltaics (PVs), are increasingly being integrated into island grids to reduce the use of imported fuels. These deployments of renewable energy are dominated by PV and wind generators, which bring unique challenges of their own. While the integration issues span numerous timescales (from microseconds to many months), this article focuses on reliability and stability challenges on short timescales (microseconds to seconds). In other words, we seek to answer (to the extent that it is currently known) how to ensure the frequency and voltage stability in an island power system with very high instantaneous levels of wind and PVs. And because island power systems are often among the first to reach these very high instantaneous levels of wind and PV generation, we note that they are forging a path for larger interconnected power systems to follow.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Impedance of silver oxide-zinc cells

Over 100 sealed AgO-Zn cells were subjected to prolonged periods of storage over a range of temperatures and storage modes including open circuit, trickle charge, and float charge. Impedances of these cells were monitored throughout, and at the end of the storage period their transient voltage characteristics were observed at the onset of discharge. Results revealed that the impedances of these cells tended to increase with storage time; the magnitude of the impedance rise was dependent primarily on temperature and to a lesser degree on storage mode. Typical values for 50 A-hr cells were usually less than 100 mohm immediately after activation and from 1 to 30 ohm after 6-10 months of storage. Transient voltages of these cells droped sharply during the first msec of discharge and then rose to a stablized value during the following few seconds. The magnitude of the initial drop and the stabilized voltage values were found to be related to impedance but not in a linear manner. The magnitude and duration of the low transient voltages may be unacceptable in some applications of these cells. The impedance variations are attributed to changes occurring at the positive electrode.

Frank, H. A.↗

Are Soft Short Tests Good Indicators of Internal Li-ion Cell Defects?

The self discharge test at full state of charge, may not be a good one to detect subtle defects since the li-ion chemistry has the highest self discharge at full state of charge. One should characterize self discharge versus storage time for each cell manufacturer/design to differentiate between normal self discharge and that due to a subtle manufacturing defect. The various soft short test methods indicate that if this test is carried out at full discharge (0% SOC) with all capacity removed (by lowering the current load in a stepwise manner to the same end of discharge voltage), then the cells need to be placed in storage for more than 72 hours to get a good analysis on the presence of subtle defects since it takes more than 72 hours to achieve voltage stabilization. If the cells are to be charged up even to a small percentage (ex. 1%), 72 hours are sufficient to determine issues. However, the pass/fail criteria should be based on a valid OCV decline. Less than 10 mV voltage decline is not a good method to detect subtle defects. As mentioned in the first bullet, self discharge is a competing reaction when a charge is introduced and hence a characterization of the self discharge versus storage time is required to fully correlate voltage decline to a failure due to a subtle defect. Soft short test method cannot be relied on for defect detection because cells with and without voltage decline seemed to have similar defects and characteristics. Screening methods such as internal resistance and capacity as well as a 3-sigma range for OCV, mass and dimensions should be used to screen out outliers. A very critical aspect in the understanding of subtle defects is to carry out destructive analysis of cells from every lot to confirm the quality of production and screen all cells and batteries in a stringent manner to have a high quality set of flight cells. Self Discharge Test: Fully charged cells shall be placed in Open circuit stand for 72 hours (OCV measurement twice a day); continue for total of 14 days with 1 reading per day 2. Soft Short Test 1: Fully charge; cells discharged to manufacturer's end of disch. Voltage (EODV) cutoff at C/5 rate; stand for 30 minutes; discharge with C/500 to the same EODV. stand for another 30 minutes; discharge the cells again using C/1000 current to the same EODV. OCV measurements twice a day for 72 hours and then for total of 14 days (data collection same as in 1.) 3. Soft Short Test 2: Fully charge; cells discharged to the manuf. EODV with a C/13 constant current; provide a 10 hour rest, discharge again to the same EODV with a current of C/250, provide a 10 hour rest, discharge again using a C/250 rate, provide a 24 hour rest, charge using C/250 to 3.15 V (for ~12 hours). OCV measurements twice a day for at 72 hours. (data collection same as in 1.) 4. Soft Short Test 3: Fully charge; cells shall be discharged using C/10 current to manuf. EODV. Allow the cell to remain at Open circuit for 10 seconds. Discharge the cell at C/20 rate to the same EODV, hold open circuit for 24 hours. Discharge the cells at C/200 rate to the same end of voltage cutoff and hold open circuit for 24 hours. Discharge the cells one more time at C/200 rate to the same EODV and hold open circuit for 36 hours. Charge at C/200 rate to 3.15 V and hold for 3 days. Record OCV during the open circuit stand periods every 12 hours and at the beginning and end of the 3 day hold (include the 12 hour OCV recording during this time also). Capacity Cycling: Cells with declining voltages - one cell from each manufacturer chosen for cycling Destructive Physical Analysis (DPA): Cells with and without decline chosen from each lot for DPA.

Jeevarajan, J.↗

Selectivity of Electrochemical Ion Insertion into Manganese Dioxide Polymorphs

The ion insertion redox chemistry of manganese dioxide has diverse applications in energy storage, catalysis, and chemical separations. Unique properties derive from the assembly of Mn–O octahedra into polymorphic structures that can host protons and nonprotonic cations in interstitial sites. Despite many reports on individual ion-polymorph couples, much less is known about the selectivity of electrochemical ion insertion in MnO 2 . In this work, we use density functional theory to holistically compare the electrochemistry of A x MnO 2 (where A = H + , Li + , Na + , K + , Mg 2+ , Ca 2+ , Zn 2+ , Al 3+ ) in aqueous and nonaqueous electrolytes. We develop an efficient computational scheme demonstrating that Hubbard-U correction has a greater impact on calculating accurate redox energetics than choice of exchange-correlation functional. Using PBE+U, we find that for nonprotonic cations, ion selectivity depends on the oxygen coordination environments inside a polymorph. When H + is present, however, the driving force to form hydroxyl bonds is usually stronger. In aqueous electrolytes, only three ion-polymorph pairs are thermodynamically stable within water’s voltage stability window (Na + and K + in α-MnO 2 , and Li + in λ-MnO 2 ), with all other ion insertion being metastable. We find Al 3+ may insert into the δ, R, and λ polymorphs across the full 2-electron redox of MnO 2 at high voltage; however, electrolytes for multivalent ions must be designed to impede the formation of insoluble precipitates and facilitate cation desolvation. We also show that small ions coinsert with water in α-MnO 2 to achieve greater coordination by oxygen, while solvation energies and kinetic effects dictate water coinsertion in δ-MnO 2 . Finally, taken together, these findings explain reports of mixed ion insertion mechanisms in aqueous electrolytes and highlight promising design strategies for safe, high energy density electrochemical energy storage, desalination batteries, and electrocatalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

How do super concentrated electrolytes push the Li-ion batteries and supercapacitors beyond their thermodynamic and electrochemical limits?

Increasing the energy density of energy storage devices is currently the key target of many battery and supercapacitor research activities. For both types of devices, the electrochemical stability window (ESW) determines the effective energy density of the device. ESWs are defined by the effective oxidation and reduction potentials of the electrolyte, which are controlled by many various factors, including the HOMO/LUMO (highest/lowest unoccupied molecular orbital) energies of the electrolyte molecules, the nature of the electrode/electrolyte interphases, and other physicochemical properties. The concentration of the electrolyte would affect the HOMO/ LUMO levels thus also change the ESW. A higher concentration of salt induces specific arrangements among the anion, cation, and solvent molecules of an electrolyte, altering the bulk behavior of the electrolyte, resulting in drastic change in the electrode interfaces. These uniquely modified physicochemical properties extend the ESW in several different ways, including the enhancement in the kinetic stability of the electrodes, as well as the thermodynamic and Nernst shifts of the oxidation/reduction potentials of the electrolyte. For organic electrolytes, it is the reduced amount of free solvent molecules that plays the key role in such changes; whereas for aqueous electrolytes, it is the scarcity of free water molecules and the reduced water activity that control the key properties of the electrolyte. Here, we focus on elucidating the fundamental structural changes occurring within an electrolyte system with increasing salt concentrations. The underlying mechanisms which not only facilitates the extension of the ESW, but also enables higher rate capabilities and mitigates aluminum dissolution for batteries with organic electrolytes, are meticulously explained. Further, we thoroughly discuss the importance of high-voltage stability in aqueous battery systems by exploiting the changed properties observed with higher concentrations of salts. To finish, high-voltage supercapacitors enabled by superconcentrated electrolytes are also explored.

25 ENERGY STORAGE↗

Multifunctional Films Deposited by Atomic Layer Deposition for Tailored Interfaces of Electrochemical Systems

A new strategy for electrochemical interfaces that utilizes multilayer films deposited by atomic layer deposition (ALD) is introduced. Manganese-rich and nickel-rich cathode oxides were coated with a novel bilayer film of metal fluorides. Subsequent exposure to prolonged, high-voltage electrochemical cycling vs graphite electrodes revealed that the bilayer film can greatly enhance the high-voltage stability of cathode oxides. In particular, in manganese-rich cells, capacity fade due to manganese dissolution was substantially reduced and impedance rise was virtually eliminated. Furthermore, in nickel-rich NMC-811 cells, impedance rise was reduced by ~80%, compared to the NMC-811 baseline, after ~300 h of high-voltage exposure during cycling. Here, the multilayer film strategy presents an exciting opportunity for tailoring designs and materials for electrochemical interfaces in advanced lithium-ion batteries and beyond.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Asymmetric Bipolar Membrane for High Current Density Electrodialysis Operation with Exceptional Stability

Bipolar membranes (BPMs) enable isolated acidic/alkaline regions in electrochemical devices, facilitating optimized environments for electrochemical separations and catalysis. For economic viability, BPMs must attain stable, high current density operation with low overpotentials in a freestanding configuration. We report an asymmetric, graphene oxide (GrOx)-catalyzed BPM capable of freestanding electrodialysis operation at 1 A cm–2 with overpotentials <250 mV. Use of a thin anion-exchange layer improves water transport while maintaining near unity Faradaic efficiency for acid and base generation. Voltage stability exceeding 1100 h with an average drift of 70 μV/h at 80 mA cm–2 and 100 h with an average drift of −300 μV/h at 500 mA cm–2 and implementation in an electrodialysis stack demonstrate real-world applicability. Continuum modeling reveals that water dissociation in GrOx BPMs is both catalyzed and electric-field enhanced, where low pK a moieties on GrOx enhance local electric fields and high pK a moieties serve as active sites for surface-catalyzed water dissociation. These results establish commercially viable BPM electrodialysis and provide fundamental insight to advance design of next-generation devices.

Lucas, Éowyn↗

High reliability megawatt transformer/rectifier

The goal of the two phase program is to develop the technology and design and fabricate ultralightweight high reliability DC to DC converters for space power applications. The converters will operate from a 5000 V dc source and deliver 1 MW of power at 100 kV dc. The power weight density goal is 0.1 kg/kW. The cycle to cycle voltage stability goals was + or - 1 percent RMS. The converter is to operate at an ambient temperature of -40 C with 16 minute power pulses and one hour off time. The uniqueness of the design in Phase 1 resided in the dc switching array which operates the converter at 20 kHz using Hollotron plasma switches along with a specially designed low loss, low leakage inductance and a light weight high voltage transformer. This approach reduced considerably the number of components in the converter thereby increasing the system reliability. To achieve an optimum transformer for this application, the design uses four 25 kV secondary windings to produce the 100 kV dc output, thus reducing the transformer leakage inductance, and the ac voltage stresses. A specially designed insulation system improves the high voltage dielectric withstanding ability and reduces the insulation path thickness thereby reducing the component weight. Tradeoff studies and tests conducted on scaled-down model circuits and using representative coil insulation paths have verified the calculated transformer wave shape parameters and the insulation system safety. In Phase 1 of the program a converter design approach was developed and a preliminary transformer design was completed. A fault control circuit was designed and a thermal profile of the converter was also developed.

Zwass, Samuel↗

Multi-Agent Graph-Attention Deep Reinforcement Learning for Post-Contingency Grid Emergency Voltage Control

Grid emergency voltage control (GEVC) is paramount in electric power systems to improve voltage stability and prevent cascading outages and blackouts in case of contingencies. While most deep reinforcement learning (DRL)-based paradigms perform single agents in a static environment, real-world agents for GEVC are expected to cooperate in a dynamically shifting grid. Moreover, due to high uncertainties from combinatory natures of various contingencies and load consumption, along with the complexity of dynamic grid operation, the data efficiency and control performance of the existing DRL-based methods are challenged. To address these limitations, we propose a multi-agent graph-attention (GATT)-based DRL algorithm for GEVC in multi-area power systems. Here, we develop graph convolutional network (GCN)-based agents for feature representation of the graph-structured voltages to improve the decision accuracy in a data-efficient manner. Furthermore, a cutting-edge attention mechanism concentrates on effective information sharing among multiple agents, synergizing different-sized subnetworks in the grid for cooperative learning. We address several key challenges in the existing DRL-based GEVC approaches, including low scalability and poor stability against high uncertainties. Test results in the IEEE benchmark system verify the advantages of the proposed method over several recent multi-agent DRL-based algorithms.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Real Time Applications Using Linear State Estimation Technology (RTA/LSE)

Electric Power Group, LLC (EPG) was awarded DOE OE0000849 to design, develop, and demonstrate three real-time applications for monitoring power system stability. The applications use phasor measurements and processing by a linear state estimator (LSE) to improve system visibility and accuracy. These applications leverage the large and expanding phasor measurement systems being deployed by utilities throughout the world, and specifically in the United States. Phasor measurements provide a much more detailed view of the power systems than traditional SCADA systems, so can provide better visibility of events and an early warning of developing problems. These three applications are real-time contingency analysis (RTCA), area angle monitoring (AAM), and a voltage stability index (VSI). The project was fully completed as proposed. All three applications were successfully implemented and demonstrated. There were challenges the caused project delays, however. While the RTCA is based on well-known concepts and readily available tools, its deployment using phasor measurements meant it needed to be adapted to sometimes sparse measurements and limited coverage areas. EPG met these challenges with extensive modeling and testing. The AAM is based on unproven research, so EPG had to deal with a lot of unknowns and develop additional methods for practical implementation. These activities took more time than anticipated, so required extra time for development. In addition, there was difficulty getting adequate measurement locations for successful deployment and utility installation delays. Consequently, the project required a time extension to complete. These three real-time applications, RTCA, AAM, and VSI, use only phasor measurement input. Since they do not require the EMS or other measurement systems, they can serve as a backup and security check for the EMS. Phasor measurements are validated and extended by an LSE. The LSE will always produce an output even when some inputs are impaired, so the RT applications will operate even when the EMS state estimator does not converge and the applications it supports cannot function. Consequently, these RT applications can provide valuable additional reliability for control center operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Barrier Function-based Reinforcement Learning for Emergency Control of Power Systems

Under voltage load shedding has been considered as a standard and effective measure to recover the voltage stability of the electric power grid under emergency and severe conditions. However, this scheme usually trips a massive amount of load which can be unnecessary and harmful to customers. Recently, deep reinforcement learning (RL) has been regarded and adopted as a promising approach that can significantly reduce the amount of load shedding. However, like most existing machine learning (ML)-based control techniques, RL control usually cannot guarantee the safety of the systems under control. In this paper, we introduce a novel safe RL method for load shedding of power systems, that can enhance the safe voltage recovery of the electric power grid after experiencing faults. Unlike standard RL method, the safe RL method integrates a Barrier function into the reward function. Consequently, the optimal control policy can render the power system to avoid the safety bounds. This method is general and can be applied to other safety-critical control problems. Numerical simulations on the 39-bus IEEE benchmark is performed to demonstrate the effectiveness of the proposed safe RL emergency control, as well as its adaptive capability to faults not seen in the training.

Vu, Thanh Long↗

Efficient learning of power grid voltage control strategies via model-based deep reinforcement learning

Here this article proposes a model-based deep reinforcement learning (DRL) method to design emergency control strategies for short-term voltage stability problems in power systems. Recent advances show promising results for model-free DRL-based methods in power systems control problems. But in power systems applications, these model-free methods have certain issues related to training time (clock time) and sample efficiency; both are critical for making state-of-the-art DRL algorithms practically applicable. DRL-agent learns an optimal policy via a trial-and-error method while interacting with the real-world environment. It is also desirable to minimize the direct interaction of the DRL agent with the real-world power grid due to its safety-critical nature. Additionally, the state-of-the-art DRL-based policies are mostly trained using a physics-based grid simulator where dynamic simulation is computationally intensive, lowering the training efficiency. We propose a novel model-based DRL framework where a deep neural network (DNN)-based dynamic surrogate model (SM), instead of a real-world power grid or physics-based simulation, is utilized within the policy learning framework, making the process faster and more sample efficient. However, having stable training in model-based DRL is challenging because of the complex system dynamics of large-scale power systems. We addressed these issues by incorporating imitation learning to have a warm start in policy learning, reward-shaping, and multi-step loss in surrogate model training. Finally, we achieved 97.5% reduction in samples and 87.7% reduction in training time for an application to the IEEE 300-bus test system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Lithium Manganese Spinel Cathodes for Lithium-Ion Batteries

Spinel LiMn 2 O 4 , whose electrochemical activity was first reported by Professor John B. Goodenough’s group at Oxford in 1983, is an important cathode material for lithium-ion batteries, which attracts continuous academic and industrial interests. It is cheap and environmentally friendly, and has excellent rate performance with 3-dimensional (3D) Li + diffusion channels. However, it suffers from severe degradations, especially under extreme voltages and during high-temperature operations. In this review, the current understanding and future trends of the spinel cathode and its derivatives with cubic lattice symmetry (LiNi 0.5 Mn 1.5 O 4 that shows high-voltage stability, and Li-rich spinels that show reversible hybrid anion- and cation-redox activities) shall be discussed. Special attention is given to the degradation mechanisms, further development of spinel cathodes, and concepts of utilizing the cubic spinel structure to stabilize high-capacity layered cathodes and as robust framework for high-rate electrodes. Lastly, “Good spinel” surface phases like LiNi 0.5 Mn 1.5 O 4 are distinguished from “bad spinel” surface phases like Mn 3 O 4 .

25 ENERGY STORAGE↗

Optimization of catholyte for halide-based all-solid-state batteries

Halide solid electrolytes gain significant attention due to their high ionic conductivity, low processing temperature, dry air compatibility, and high-voltage stability. However, low cathode active material (CAM) loading in the composite cathode constrains the realization of high energy density for halide-based all-solid-state batteries. In this study, three halide materials, raw Li 3 YBrCl 5 (LYBC-R, <30μm), milled LYBC (LYBC-M, <5 μm) and freeze-dried Li 3 InCl 6 (LIC, <500 nm), were used as catholytes, combined with LYBC-M as the electrolyte and LiIn alloy as the anode. The CAM:catholyte ratio was investigated as well as stack pressure and operating temperature. Our study demonstrates that particle size of the catholyte plays an important role only for high CAM loading or high C-rate cycling. At moderate CAM loading (65 and 70wt% LiNi 0.83 Mn 0.06 Co 0.11 O 2 ) and 0.1 C-rate, all the three catholytes perform well, providing initial discharge capacities >177 mAh/g. At high CAM loading (85wt%) and 0.1 C-rate, a cathode with the nano-scale LIC catholyte provides discharge capacity of 175 mAh/g, while the larger particle size catholytes suffer significantly reduced capacity. Both LYBC and LIC catholytes provided capacity retention >80% after 200 cycles at 0.5C. These results imply that cathode particle size is critically important for performance at high CAM loading. Furthermore, both electrolyte and cathode were tape cast to scale up size and prepare realistic layer thicknesses. A small amount of binder was used in both layers, to balance the electrochemical performance and mechanical properties. Further, the discharge capacity of a tape cell was 152mA h/g at 0.1C with a capacity retention of 81.8% after 20 cycles at 0.5C. The results demonstrate the excellent performance of LYBC as an electrolyte, and provide guidance for halide-based cathode design.

25 ENERGY STORAGE↗

Performance assessment after long-term irradiation of ATLAS Micromegas detectors using 120 GeV muons at the Gamma Irradiation Facility at CERN

The ATLAS muon spectrometer will face an increased particle rate as a result of the increased instantaneous luminosity expected during the High-Luminosity LHC (HL-LHC) upgrade. The HL-LHC will provide a luminosity of $\mathscr{L}$ = 7.5 × 10 34 cm −2 s −1 and 3000 fb −1 of integrated luminosity in 10 years, about 9 times more data of the ones so far collected by the ATLAS experiment. Micromegas chambers are used in the New Small Wheel(s), the first forward muon spectrometer station, to provide tracking and triggering at the intense particle rates expected. The detectors are operated with a ternary gas mixture composed of Ar + 5%CO 2 + 2%iC 4 H 10 , providing good high voltage stability and a large pulse height, important for inclined track reconstruction of particles crossing the detector. To ensure the long-term stable operation of the detector during the whole HL-LHC period, and due to the hydrocarbon content in the mixture, an extensive aging campaign has been ongoing since 2021 at the CERN Gamma Irradiation Facility, where spare production chambers are long-term exposed to a 14 TBq 137 Cs 𝛾-source, accumulating so far, a charge equivalent to five years of HL-LHC operations under the highest expected background rate. This paper describes the results of the Micromegas chamber performance studies after two years of gamma irradiation and using the SPS/H4 120 GeV muon beams at CERN.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Toward Fullerene-Free PIN Perovskite Solar Cells

We highlight opportunities for a transformative shift in perovskite solar cell design by expanding electron transport layers (ETLs) beyond fullerenes. Fullerenes have known limitations, including constraints on open-circuit voltage, stability, and mechanical integrity. Recently, fullerene-free p-i-n cells with power conversion efficiencies exceeding 25% have been demonstrated via both naphthalene diimide-SnO x bilayers and nonfullerene acceptor-based ETLs. Despite successes, fullerenes remain the de facto ETLs for perovskites. Drawing lessons from organic photovoltaics, where it took decades to transition from fullerenes to more broadly available and efficient materials, we explore pathways to accelerate the development and adoption of fullerene-free ETLs. This requires understanding the similarities and differences between organic and perovskite solar cells, which will necessitate carefully designing fullerene replacements with both, high efficiency and also, critically, durability under operation. Here, we incorporate literature data to facilitate comparisons, and independently conduct fracture energy measurements for alternative ETL configurations to motivate their adoption.

14 SOLAR ENERGY↗