Engineering PapersSearch

SEARCH · Engineering Papers

Results for “voltage regulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

NLR HPC Eagle GPU Node Metrics

Ganglia node metrics and iLO (Integrated Lights Out) power data captured from six representative Eagle GPU nodes The Eagle HPC operated at NLR from 2019 through 2024. Eagle was a 2,000-node, 8-petaflop system. This dataset is a representative sample of metrics for 6 of the GPU nodes. Each GPU node contained 2 CPUs and 2 GPUs. Data provided in compressed CSV format. Ganglia and iLO Power Time Series Fields ts: Timestamp dv: Device / Node - Rack and Unit - r103u17 == r(ack)103u(nit)17 mt: Metric (only present for Ganglia) vl: Value - Value in watts for iLO power (instantaneous value at sampling time) or specified Ganglia metric below Ganglia Metrics Metric name -- Metric description -- Unit cpu_aidle -- Percent of time since boot idle CPU -- Percent cpu_idle -- Percent CPU idle -- Percent cpu_nice -- Percent CPU nice -- Percent cpu_speed -- Speed in MHz of CPU -- MHz cpu_user -- Percent CPU user -- Percent cpu_wio -- The percentage of CPU Wait I/O -- Percent gpu0_bar1_memory -- Used GPU bar1 memory -- MB gpu0_decoder_util -- GPU decoder utilization -- Percent gpu0_ecc_db_error -- Total ECC error counts for the GPU -- Number gpu0_encoder_util -- GPU encoder utilization -- Percent gpu0_fan -- Fan speed -- RPM gpu0_fb_memory -- Used GPU framebuffer memory -- MB gpu0_graphics_clock_report -- Current clock speeds for the device -- MHz gpu0_mem_total -- Memory total -- MB gpu0_mem_util -- Memory utilization -- Percent gpu0_power_usage_report -- Power usage report -- Watts gpu0_temp -- GPU 1 temperature -- Celsius gpu1_bar1_memory -- Used GPU bar1 memory -- MB gpu1_decoder_util -- GPU decoder utilization -- Percent gpu1_ecc_db_error -- Total ECC error counts for the GPU -- Number gpu1_encoder_util -- GPU encoder utilization -- Percent gpu1_fan -- Fan speed -- RPM gpu1_fb_memory -- Used GPU framebuffer memory -- MB gpu1_graphics_clock_report -- Current clock speeds for the GPU -- MHz gpu1_mem_total -- Memory total -- MB gpu1_mem_util -- Memory utilization -- MB gpu1_power_usage_report -- Power usage report -- Watts gpu1_temp -- GPU 1 temperature -- Celsius ipmi_cpu1_temp -- CPU 1 temperature -- Celsius ipmi_cpu2_temp -- CPU 2 temperature -- Celsius ipmi_inlet_ambient_temp -- Temperature measured at intake -- Celsius ipmi_vr_p1_temp -- CPU 1 voltage regulator temperature -- Celsius ipmi_vr_p2_temp -- CPU 2 voltage regulator temperature -- Celsius mem_buffers -- Amount of buffered memory -- Bytes mem_cached -- Amount of cached memory -- Bytes mem_free -- Amount of available memory -- Bytes mem_shared -- Amount of shared memory -- Bytes mem_total -- Amount of available memory -- Bytes

97 MATHEMATICS AND COMPUTING

Method and Circuit for In-Situ Health Monitoring of Solar Cells in Space

This innovation represents a method and circuit realization of a system designed to make in-situ measurements of test solar-cell operational parameters on orbit using readily available high-temperature and high-ionizing-radiation- tolerant electronic components. This innovation enables on-orbit in-situ solar-array health monitoring and is in response to a need recognized by the U.S. Air Force for future solar arrays for unmanned spacecraft. This system can also be constructed out of commercial-grade electronics and can be embedded into terrestrial solar power system as a diagnostics instrument. This innovation represents a novel approach to I-V curve measurement that is radiation and temperature hard, consumes very few system resources, is economical, and utilizes commercially available components. The circuit will also operate at temperatures as low as 55 C and up to +225 C, allowing it to reside close to the array in direct sunlight. It uses a swept mode transistor functioning as a resistive load while utilizing the solar cells themselves as the biasing device, so the size of the instrument is small and there is no danger of over-driving the cells. Further, this innovation utilizes nearly universal spacecraft bus resources and therefore can be readily adapted to any spacecraft bus allowing for ease of retrofit, or designed into new systems without requiring the addition of infrastructure. One unique characteristic of this innovation is that it effects the measurement of I-V curves without the use of large resistor arrays or active current sources normally used to characterize cells. A single transistor is used as a variable resistive load across the cell. This multi-measurement instrument was constructed using operational amplifiers, analog switches, voltage regulators, MOSFETs, resistors, and capacitors. The operational amplifiers, analog switches, and voltage regulators are silicon-on-insulator (SOI) technology known for its hardness to the effects of ionizing radiation. The SOI components used can tolerate temperatures up to 225 C, which gives plenty of thermal headroom allowing this circuit to perhaps reside in the solar cell panel itself where temperatures can reach over 100 C.

Krasowski, Michael J.

A historical overview of the electrical power systems in the US manned and some US unmanned spacecraft

A historical overview of electrical power systems used in the U.S. manned spacecraft and some of the U.S. unmanned spacecraft is presented in this investigation. A time frame of approximately 25 years, the period for 1959 to 1984, is covered in this report. Results indicate that the nominal bus voltage was 28 volts dc in most spacecraft and all other voltage levels were derived from this voltage through such techniques as voltage inversion or rectification, or a combination. Most spacecraft used solar arrays for the main source of power except for those spacecraft that had a relatively short flight duration, or deep spaceprobes that were designed for very long flight duration. Fuel cells were used on Gemini, Apollo, and Space Shuttle (short duration flights) while radioisotope thermoelectric generators were employed on the Pioneer, Jupiter/Saturn, Viking Lander, and Voyager spacecraft (long duration flights). The main dc bus voltage was unregulated on the manned spacecraft with voltage regulation provided at the user loads. A combination of regulated, semiregulated, and unregulated buses were used on the unmanned spacecraft depending on the type of load. For example, scientific instruments were usually connected to regulated buses while fans, relays, etc. were energized from an unregulated bus. Different forms of voltage regulation, such as shunt, buck/boot, and pulse-width modulated regulators, were used. This report includes a comprehensive bibliography on spacecraft electrical power systems for the space programs investigated.

Maisel, J. E.

A High Efficiency DC Bus Regulator/RPC for Spacecraft Applications

DC bus voltage regulation may be required in future high powered spacecraft due to the length of the busses or because they are not generated at precise voltage levels. In these cases the regulation range is often only a few percent increase or decrease, but conventional DC voltage regulators switch all the power passing through them, and this level of power switched determines the size and losses in the regulator. A recently developed concept used a low power DC-DC converter in series with the bs to raise or lower the bus voltage over a small range. This partial power processing technique combines the small size and power losses of the low power converter with the ability to regulate, (over a small range) a high power bus. The Series Connected Buck Boost Regulator (SCBBR) described herein provides bus regulation with an efficiency of 98%. The circuit also provides bus switching and overcurrent limiting functions of a Remote Power Controller (RPC). This paper described the circuit design and performance of a breadboard SCBBR configured as a bus voltage regulator providing plus of minus 40% voltage regulation range, bus switching, and overload limiting.

Birchenough, Arthur G.

Quasi-Linear Circuit

This work involved developing spacequalifiable switch mode DC/DC power supplies that improve performance with fewer components, and result in elimination of digital components and reduction in magnetics. This design is for missions where systems may be operating under extreme conditions, especially at elevated temperature levels from 200 to 300 degC. Prior art for radiation-tolerant DC/DC converters has been accomplished utilizing classical magnetic-based switch mode converter topologies; however, this requires specific shielding and component de-rating to meet the high-reliability specifications. It requires complex measurement and feedback components, and will not enable automatic re-optimization for larger changes in voltage supply or electrical loading condition. The innovation is a switch mode DC/DC power supply that eliminates the need for processors and most magnetics. It can provide a well-regulated voltage supply with a gain of 1:100 step-up to 8:1 step down, tolerating an up to 30% fluctuation of the voltage supply parameters. The circuit incorporates a ceramic core transformer in a manner that enables it to provide a well-regulated voltage output without use of any processor components or magnetic transformers. The circuit adjusts its internal parameters to re-optimize its performance for changes in supply voltage, environmental conditions, or electrical loading at the output

Bradley, William

Input-current shaped ac to dc converters

The problem of achieving near unity power factor while supplying power to a dc load from a single phase ac source of power is examined. Power processors for this application must perform three functions: input current shaping, energy storage, and output voltage regulation. The methods available for performing each of these three functions are reviewed. Input current shaping methods are either active or passive, with the active methods divided into buck-like and boost-like techniques. In addition to large reactances, energy storage methods include resonant filters, active filters, and active storage schemes. Fast voltage regulation can be achieved by post regulation or by supplementing the current shaping topology with an extra switch. Some indications of which methods are best suited for particular applications concludes the discussion.

Source record

A Data-Driven Voltage Control Strategy for Distribution Grids With Distributed Energy Resources

Traditionally, distribution system control approaches have been model-based. The deployment of advanced metering infrastructure has provided electric utilities with the capability of data-driven control with real-time measurements. The shift from model-based to data-driven control represents a significant advancement in the management of distribution systems, offering a more adaptive approach to system control because of the ability to dynamically adapt to changing conditions without the need for system modeling. Here, in this paper, a behavioral data-driven control method is developed to provide voltage regulation to an actual distribution system by controlling the legacy devices and distributed energy resource (DER) assets. The studied distribution system has a load tap changer and three capacitor banks as the legacy devices and photovoltaic systems as the DERs. The performance of the proposed control algorithm is validated using a laboratory test bed setup considering multiple scenarios. The results show that the proposed control achieved 99% voltage regulation.

24 POWER TRANSMISSION AND DISTRIBUTION

HSYE-117RH Voltage Linear Regulator Total Ionizing Dose Test Report

The purpose of this test was to validate the Intersil HSYE-117RH-Q flight lot for use in the fabrication of Europa Clipper Propulsion subsystem flight hardware. This test shall serve as the radiation lot acceptance test (RLAT) for the flight lot date with wafer lot number G3X3CQC and lot date code (LDC) 1830. Low dose rate (LDR) irradiations have been performed by the manufacturer, but only to 100 krad(Si). This test determined the enhanced low dose rate sensitivity (ELDRS) of the device up to the mission specific dose of 125 krad(Si).

Total Ionizing Dose (TID)

HSYE-117RH Voltage Linear Regulator Total Ionizing Dose Test Report

The purpose of this test was to validate the Intersil HSYE-117RH-Q flight lot for use in the fabrication of Europa Clipper Propulsion subsystem flight hardware. This test shall serve as the radiation lot acceptance test (RLAT) for the flight lot date with wafer lot number G3X3CQC and lot date code (LDC) 1830. Low dose rate (LDR) irradiations have been performed by the manufacturer, but only to 100 krad(Si). This test was a follow-on to the original Radiation Lot-Specific Acceptance Testing (RLAT) performed on this LDC. Application-specific load currents were used for the line regulation and load regulation measurements. All other parameters were measured with standard bias conditions as specified in the datasheet.

Total Ionizing Dose (TID)

A closely regulated TWT converter.

The design concept for the TWT amplifier converter for possible use in the Thermoelectric Outer Planet Spacecraft (TOPS) is presented. An unusual combination of semiconductors and magnetics was utilized to achieve very stable voltage regulation on a number of separate outputs to satisfy the requirements of a high-power TWT, and at the same time operate at an efficiency of better than 90% from a 30-V source. The circuitry consists of an output filter, an auxiliary Jensen oscillator driving a high-reactance transformer to provide current limiting to the heater, a variable time delay, a main Jensen oscillator driving the power transformer with a maximum step-up ratio of 120 to 1, and series transistorized post regulators to provide precise voltage adjustment and low output impedance. This paper discusses the design of the high-reactance transformer and the high step-up ratio transformer, as well as the high-voltage series regulators that are limited in range and operate at the top of the unregulated output voltage. Test data are presented, and details of current transients caused by charging the filter circuits, input current ripple, and output voltage ripples are considered.

Hopper, D. J.

Cascaded resonant bridge converters

A converter for converting a low voltage direct current power source to a higher voltage, high frequency alternating current output for use in an electrical system where it is desired to use low weight cables and other circuit elements. The converter has a first stage series resonant (Schwarz) converter which converts the direct current power source to an alternating current by means of switching elements that are operated by a variable frequency voltage regulator, a transformer to step up the voltage of the alternating current, and a rectifier bridge to convert the alternating current to a direct current first stage output. The converter further has a second stage series resonant (Schwarz) converter which is connected in series to the first stage converter to receive its direct current output and convert it to a second stage high frequency alternating current output by means of switching elements that are operated by a fixed frequency oscillator. The voltage of the second stage output is controlled at a relatively constant value by controlling the first stage output voltage, which is accomplished by controlling the frequency of the first stage variable frequency voltage controller in response to second stage voltage. Fault tolerance in the event of a load short circuit is provided by making the operation of the first stage variable frequency voltage controller responsive to first and second stage current limiting devices. The second stage output is connected to a rectifier bridge whose output is connected to the input of the second stage to provide good regulation of output voltage wave form at low system loads.

Stuart, Thomas A.

Programmable high voltage power supply with regulation confined to the high voltage section

A high voltage power supply in a dc-dc converter configuration includes a pre-regulator which filters and regulates the dc input and drives an oscillator which applies, in turn, a low voltage ac signal to the low side of a step-up high voltage transformer. The high voltage side of the transformer drives a voltage multiplier which provides a stepped up dc voltage to an output filter. The output voltage is sensed by a feedback network which then controls a regulator. Both the input and output of the regulator are on the high voltage side, avoiding isolation problems. The regulator furnishes a portion of the drive to the voltage multiplier, avoiding having a regulator in series with the load with its attendant, relatively high power losses. This power supply is highly regulated, has low power consumption, a low parts count and may be manufactured at low cost. The power supply has a programmability feature that allows for the selection of a large range of output voltages.

Castell, Karen D.

Improving Power-Supply Regulation for Pulsed Loads

Power supply voltage-regulator circuit speeds up response to sudden load changes. As load increases, additional feedback path is enabled. Path bypasses and provides faster loop response than normal feedback path. Steady-state instability due to faster loop response avoided by progressively disabling bypass loop and allowing normal feedback path to take over.

Gulick, C. R.

Fuel cell technology program contract summary report

A fuel cell technology program which was established to advance the state-of-the-art of hydrogen-oxygen fuel cells using the P and WA PC8B technology as the base is reported. The major tasks of this program consisted of (1) fuel cell system studies of a space shuttle powerplant conceptual design (designated engineering model -1, EM-1) supported by liaison with the space shuttle prime contractors; (2) component and subsystem technology advancement and; (3) a demonstrator powerplant test. Fuel cell system studies, with the EM-1 as the focal point of design activities, included determination of voltage regulation, specific reactant consumption, weight, voltage level and performance characteristics. These studies provided the basis for coordination activities with the space shuttle vehicle prime contractor. Interface information, on-board checkout and in-flight monitoring requirements, and development cost data were also provided as part of this activity. Even though the two vehicles primes had different voltage requirements (115 volts in one case and 28 volts in the other), it was concluded that either option could be provided in the fuel cell power system by the electrical hook-up of the cells in the stack.

Source record