SEARCH · Engineering Papers
Results for “voltage”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Untapped Potential: The Need and Opportunity for High-Voltage Aqueous Redox Flow Batteries
Explore the source record for details and available documents.
Deep Learning-Based Dynamic Modeling of Three-Phase Voltage Source Inverters
Inverter-based resource (IBR) models are necessary to analyze modern power system stability and create effective control strategies. Modeling IBRs in converter-rich power systems is crucial, yet challenging due to the lack of commercial information on converter topologies and control parameters. This paper proposes novel convolutional neural network (CNN)–based data-driven techniques for modeling IBRs, addressing adaptability and proprietary concerns without requiring internal system physics knowledge. The proposed method is tested using real grid-tied commercial IBR transient data and demonstrates effectiveness and accuracy. Furthermore, the developed modeling approach is integrated and implemented in the open-source power distribution simulation and analysis tool, GridLAB-D, to illustrate the potentiality of dynamic analysis of large-scale power systems with high IBRs.
Performance of a Grid-Forming Inverter Under Balanced and Unbalanced Voltage Phase Angle Jump Conditions .
Abstract not provided.
Structural basis for C-type inactivation in a Shaker family voltage-gated K[superscript +[ channel
Explore the source record for details and available documents.
Predicting Voltage Changes in Low-Voltage Secondary Networks using Deep Neural Networks
Explore the source record for details and available documents.
Estimation of PV Location based on Voltage Sensitivities in Distribution Systems with Discrete Voltage Regulation Equipment.
Abstract not provided.
Predicting Voltage Changes in Low-Voltage Secondary Networks using Deep Neural Networks
Explore the source record for details and available documents.
Improved Control of Charging Voltage for Li-Ion Battery
The protocol for charging a lithium-ion battery would be modified, according to a proposal, to compensate for the internal voltage drop (charging current internal resistance of the battery). The essence of the modification is to provide for measurement of the internal voltage drop and to increase the terminal-voltage setting by the amount of the internal voltage drop. Ordinarily, a lithium-ion battery is charged at constant current until its terminal voltage attains a set value equal to the nominal full-charge potential. The set value is chosen carefully so as not to exceed the lithium-plating potential, because plated lithium in metallic form constitutes a hazard. When the battery is charged at low temperature, the internal voltage drop is considerable because the electrical conductivity of the battery electrolyte is low at low temperature. Charging the battery at high current at any temperature also gives rise to a high internal voltage drop. In some cases, the internal voltage drop can be as high as 1 volt per cell. Because the voltage available for charging is less than the terminal voltage by the amount of the internal voltage drop, the battery is not fully charged (see figure), even when the terminal voltage reaches the set value. In the modified protocol, the charging current would be periodically interrupted so that the zero-current battery-terminal voltage indicative of the state of charge could be measured. The terminal voltage would also be measured at full charging current. The difference between the full-current and zero-current voltages would equal the internal voltage drop. The set value of terminal voltage would then be increased beyond the nominal full-charge potential by the amount of the internal voltage drop. This adjustment would be performed repeatedly, in real time, so that the voltage setting would track variations in the internal voltage drop to afford full charge without risk of lithium plating. If the charging current and voltage settings were controlled by a computer, then this method of charge control could readily be implemented in software.
Performance of Li-Ion Cells Under Battery Voltage Charge Control
A study consisting of electrochemical characterization and Low-Earth-Orbit (LEO) cycling of Li-Ion cells from three vendors was initiated in 1999 to determine the cycling performance and to infuse the new technology in the future NASA missions. The 8-cell batteries included in this evaluation are prismatic cells manufactured by Mine Safety Appliances Company (MSA), cylindrical cells manufactured by SAFT and prismatic cells manufactured by Yardney Technical Products, Inc. (YTP). The three batteries were cycle tested in the LEO regime at 40% depth of discharge, and under a charge control technique that consists of battery voltage clamp with a current taper. The initial testing was conducted at 20 C; however, the batteries were cycled also intermittently at low temperatures. YTP 20 Ah cells consisted of mixed-oxide (Co and Ni) positive, graphitic carbon negative, LIPF6 salt mixed with organic carbonate solvents. The battery voltage clamp was 32 V. The low temperature cycling tests started after 4575 cycles at 20 C. The cells were not capable of cycling. at low temperature since the charge acceptance at battery level was poor. There was a cell in the battery that showed too high an end-of-charge (EOC) voltage thereby limiting the ability to charge the rest of the cells in the battery. The battery has completed 6714 cycles. SAFT 12 Ah cells consisted of mixed-oxide (Co and NO positive, graphitic carbon negative, LiPF6 salt mixed with organic carbonate solvents. The battery voltage clamp was for 30.8 V. The low temperature cycling tests started after 4594 cycles at 20 C. A cell that showed low end of discharge (EOD) and EOC voltages and three other cells that showed higher EOC voltages limited the charge acceptance at the selected voltage limit during charge. The cells were capable of cycling at 10 C and 0 C but the charge voltage limit had to be increased to 34.3 V (4.3 V per cell). The low temperature cycling may have induced poor chargeability since the voltage had to be increased to achieve the required charge input. The battery has completed 6226 cycles. MSA 10 Ah cells consisted of Co oxide positive, graphitic carbon negative, LiPF6 salt mixed with organic carbonate solvents. The battery voltage clamp was 30.8 V. The low temperature cycling tests were started after 2182 cycles at 20 C. The cells were capable of cycling at 10 C and 0 C. Like SAFT, the voltage limit on charge had to be increased to 36 V (4.5 V per cell). There was a cell (cell S/N 13) in the battery that showed poor performance features such as low EOD voltage and high EOC voltage. The battery has completed 3441 cycles. A reconditioning procedure that consisted of C15 charge to a taper current of C/100 and C/20 discharge improved the voltage behavior of SAFT and MSA cells with no significant effect on YTP cells. We have demonstrated that the charge operation with VT clamp at battery rather than at cell level is feasible for onboard Li-Ion battery operation.
Mixed voltage VLSI design
A technique for minimizing the power dissipated in a Very Large Scale Integration (VLSI) chip by lowering the operating voltage without any significant penalty in the chip throughput even though low voltage operation results in slower circuits. Since the overall throughput of a VLSI chip depends on the speed of the critical path(s) in the chip, it may be possible to sustain the throughput rates attained at higher voltages by operating the circuits in the critical path(s) with a high voltage while operating the other circuits with a lower voltage to minimize the power dissipation. The interface between the gates which operate at different voltages is crucial for low power dissipation since the interface may possibly have high static current dissipation thus negating the gains of the low voltage operation. The design of a voltage level translator which does the interface between the low voltage and high voltage circuits without any significant static dissipation is presented. Then, the results of the mixed voltage design using a greedy algorithm on three chips for various operating voltages are presented.
Voltage-current-power meter for photovoltaic solar arrays
A meter is disclosed for measuring the voltage, current, and power (VIP) parameters of a photovoltaic solar array, or array module, under sunlight operating conditions utilizing a variable load connected across the array and controlled by a voltage regulator which responds to the difference between the output voltage of the array and a programmed test voltage from a source which generates a single ramp voltage for measuring and recording current as a function of voltage, repeated ramp voltages at a high rate for peak output measurements or a DC voltage for VIP measurements at selected points on the I-V characteristic curve of the array. The voltage signal from a current sensing element, such as a shunt resistor in series with the variable load, is compared with the output current of a reference solar cell to provide a normalizing signal to be added to the signal from the current-sensing element in order to provide a record of array current as a function of array voltage, i.e., for all load conditions from short circuit to open circuit. As the normalized current is thus measured, an analog multiplier multiplies the array voltage and normalized current to provide a measurement of power. Switches are provided to selectively connect the power, P, current, I, or voltage, V, to a meter, directly or through a peak detector. At the same time any one of the parameters V, I and P may be recorded as a function of any other parameter.
Predictive Coordinated and Cooperative Voltage Control for Systems With High Penetration of PV
In this paper, we propose a predictive coordinated and cooperative voltage control method in a power distribution system with high penetration of photovoltaic (PV) units. First, an integrated coordinated voltage control of voltage regulators (VRs) tap positions and cooperative distributed control of the reactive power output from PV inverters are used to maintain system voltages within an appropriate bandwidth. Next, solar power forecasting is applied to predict voltage changes, which are used to set the VR tap positions and capacitor switch status to prevent large voltage fluctuations. The fine tuning of voltage adjustment is then achieved by cooperative control of PV inverters to maintain a uniform voltage profile across the system. The proposed method is tested on a modified IEEE 123-node test feeder with high penetration of PVs using real measurement data and compared with the base case. Simulation results demonstrate the effectiveness of the integrated voltage control, as well as the enhancement from the predictive control through solar power forecasting-enabled voltage change estimates. Comparison to previous work in the literature shows significant improvement in terms of voltage deviation and reduction in excessive tap changes.
Correlating armature and needle dynamics with voltage waveforms of solenoid-actuated GDI injector
The injector voltage hump that appears near the needle closing has been used for the real-time monitoring and feedback control of fuel injection duration in modern engines. This voltage hump has been thought to result from the abrupt change in electromagnetic induction by the stoppage of needle motion but detailed electromagnetic processes and associated armature and needle dynamics during the needle closing have not been thoroughly investigated in a wide range of injection conditions, which knowledge is crucial for the delicate control of fuel injection based on the voltage hump. Here, the current study analyzes the transient armature and needle dynamics of a solenoid-actuated gasoline direct injection injector using an X-ray phase-contrast imaging technique. Then, the results are correlated with voltage waveforms during the needle closing transient under various injection pressures, injection pulse durations, and dwell times of split injections. The time derivatives of voltage waveforms showed lower and upper peaks in order in the regime of the voltage hump. Inconsistent with conventional understandings, the lower peak timing of the voltage derivative did not match with the timing of needle closing (end of injection) but rather matched with the abrupt descent timing of the armature and needle. The inflection timing and upper peak timing of the voltage derivative matched with the timings of actual needle closing and armature closing respectively. The amplitude of the voltage hump was near linearly dependent on the needle closing speed. The needle closing speed decreased upon the decrease of injection pulse duration and injection pressure which made it difficult to detect the voltage humps in ballistic injection regimes and low injection pressures. In split injection conditions, the voltage hump of the first injection was not detectable if the dwell time was shorter than the needle closing delay, the time from the current cut-off to the actual needle closing.
Rad-Hard, Miniaturized, Scalable, High-Voltage Switching Module for Power Applications Rad-Hard, Miniaturized
A paper discusses the successful development of a miniaturized radiation hardened high-voltage switching module operating at 2.5 kV suitable for space application. The high-voltage architecture was designed, fabricated, and tested using a commercial process that uses a unique combination of 0.25 micrometer CMOS (complementary metal oxide semiconductor) transistors and high-voltage lateral DMOS (diffusion metal oxide semiconductor) device with high breakdown voltage (greater than 650 V). The high-voltage requirements are achieved by stacking a number of DMOS devices within one module, while two modules can be placed in series to achieve higher voltages. Besides the high-voltage requirements, a second generation prototype is currently being developed to provide improved switching capabilities (rise time and fall time for full range of target voltages and currents), the ability to scale the output voltage to a desired value with good accuracy (few percent) up to 10 kV, to cover a wide range of high-voltage applications. In addition, to ensure miniaturization, long life, and high reliability, the assemblies will require intensive high-voltage electrostatic modeling (optimized E-field distribution throughout the module) to complete the proposed packaging approach and test the applicability of using advanced materials in a space-like environment (temperature and pressure) to help prevent potential arcing and corona due to high field regions. Finally, a single-event effect evaluation would have to be performed and single-event mitigation methods implemented at the design and system level or developed to ensure complete radiation hardness of the module.
An Information Theoretic Approach to Identify Dominant Voltage Influencers for Unbalanced Distribution Systems
Smart distribution grid with multiple renewable energy sources can experience random voltage fluctuations due to variable generation, which may result in voltage violations. Traditional voltage control algorithms are inadequate to handle fast voltage variations. Therefore, new dynamic control methods are being developed that can significantly benefit from the knowledge of dominant voltage influencer (DVI) nodes. DVI nodes for a particular node of interest refer to nodes that have a relatively high impact on the voltage fluctuations at that node. Conventional power flow-based algorithms to identify DVI nodes are computationally complex, which limits their use in real-time applications. This paper proposes a novel information theoretic voltage influencing score (VIS) that quantifies the voltage influencing capacity of nodes with DERs/active loads in a three phase unbalanced distribution system. VIS is then employed to rank the nodes and identify the DVI set. VIS is derived analytically in a computationally efficient manner and its efficacy to identify DVI nodes is validated using the IEEE 37-node test system. It is shown through experiments that KL divergence and Bhattacharyya distance are effective indicators of DVI nodes with an identifying accuracy of more than 90%. Additionally, the computation burden is also reduced by an order of 5, thus providing the foundation for efficient voltage control.
Controllable high voltage source having fast settling time
A high voltage dc stepping power supply for sampling a utilization device such as an electrostatic analyzer has a relatively fast settling time for voltage steps. The supply includes a waveform generator for deriving a low voltage staircase waveform that feeds a relatively long response time power supply, deriving a high output voltage generally equal to a predetermined multiple of the input voltage. In the power supply, an ac voltage modulated by the staircase waveform is applied to a step-up transformer and then to a voltage multiplier stack to form a high voltage, relatively poor replica of the input waveform at an intermediate output terminal. A constant dc source, applied to the input of the power supply, biases the voltage at the intermediate output terminal to be in excess of the predetermined multiple of the input voltage.
Preventing Voltage Divergence in Series-Stacked Bidirectional Battery Energy Storage DC-DC Converter under Asymmetrical Operating Conditions
DC stacked topologies have gained popularity for interfacing individual photovoltaic panels to a high-voltage DC bus. A similar approach can be used to interface individual battery packs to the same DC bus, which allows active balancing of battery substrings and the use of lower voltage switches. Any imbalance in battery current, however, can cause the converter output voltages to diverge. This paper describes the source of voltage divergence and demonstrates a solution that allows seamless stacking of multiple battery packs to be interfaced to a high voltage DC bus. To prevent the voltage divergence phenomenon and allow asymmetrical battery charging for efficient battery state of charge management, the PI-based decentralized voltage control enabling both capacitor voltage sharing and asymmetrical capacitor voltage control is proposed. The effectiveness of the decentralized voltage control strategy is demonstrated through controller hardware-in-the-loop test results.