Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “vessel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Acoustic emission testing of composite vessels under sustained loading

Acoustic emissions (AE) generated from Kevlar 49/epoxy composite pressure vessels subjected to sustained load-to-failure tests were studied. Data from two different transducer locations on the vessels were compared. It was found that AE from vessel wall-mounted transducers showed a wide variance from those for identical vessels subjected to the same pressure loading. Emissions from boss-mounted transducers did, however, yield values that were relatively consistent. It appears that the signals from the boss-mounted transducers represent an integrated average of the emissions generated by fibers fracturing during the vessel tests. The AE from boss-mounted transducers were also independent of time for vessel failure. This suggests that a similar number of fiber fractures must occur prior to initiation of vessel failure. These studies indicate a potential for developing an AE test procedure for predicting the residual service life or integrity of composite vessels.

Lark, R. F.↗

High-performance fiber/epoxy composite pressure vessels

Activities described include: (1) determining the applicability of an ultrahigh-strength graphite fiber to composite pressure vessels; (2) defining the fatigue performance of thin-titanium-lined, high-strength graphite/epoxy pressure vessel; (3) selecting epoxy resin systems suitable for filament winding; (4) studying the fatigue life potential of Kevlar 49/epoxy pressure vessels; and (5) developing polymer liners for composite pressure vessels. Kevlar 49/epoxy and graphite fiber/epoxy pressure vessels, 10.2 cm in diameter, some with aluminum liners and some with alternation layers of rubber and polymer were fabricated. To determine liner performance, vessels were subjected to gas permeation tests, fatigue cycling, and burst tests, measuring composite performance, fatigue life, and leak rates. Both the metal and the rubber/polymer liner performed well. Proportionately larger pressure vessels (20.3 and 38 cm in diameter) were made and subjected to the same tests. In these larger vessels, line leakage problems with both liners developed the causes of the leaks were identified and some solutions to such liner problems are recommended.

Chiao, T. T.↗

Non-invasive method and apparatus for measuring pressure within a pliable vessel

A non-invasive method and apparatus is disclosed for measuring pressure within a pliable vessel such as a blood vessel. The blood vessel is clamped by means of a clamping structure having a first portion housing a pressure sensor and a second portion extending over the remote side of the blood vessel for pressing the blood vessel into engagement with the pressure sensing device. The pressure sensing device includes a flat deflectable diaphragm portion arranged to engage a portion of the blood vessel flattened against the diaphragm by means of the clamp structure. In one embodiment, the clamp structure includes first and second semicylindrical members held together by retaining rings. In a second embodiment the clamp structure is of one piece construction having a solid semicylindrical portion and a hollow semicylindrical portion with a longitudinal slot in the follow semicylindrical portion through which a slip the blood vessel. In a third embodiment, an elastic strap is employed for clamping the blood vessel against the pressure sensing device.

Shimizu, M.↗

Experimental Investigation of Composite Pressure Vessel Performance and Joint Stiffness for Pyramid and Inverted Pyramid Joints

The focus of this study is on the suitability in the application of classical laminate theory analysis tools for filament wound pressure vessels with adhesive laminated joints in particular: pressure vessel wall performance, joint stiffness and failure prediction. Two 18-inch diameter 12-ply filament wound pressure vessels were fabricated. One vessel was fabricated with a 24-ply pyramid laminated adhesive double strap butt joint. The second vessel was fabricated with the same number of plies in an inverted pyramid joint. Results from hydrostatic tests are presented. Experimental results were used as input to the computer programs GENLAM and Laminate, and the output compared to test. By using the axial stress resultant, the classical laminate theory results show a correlation within 1% to the experimental results in predicting the pressure vessel wall pressure performance. The prediction of joint stiffness for the two adhesive joints in the axial direction is within 1% of the experimental results. The calculated hoop direction joint stress resultant is 25% less than the measured resultant for both joint configurations. A correction factor is derived and used in the joint analysis. The correction factor is derived from the hoop stress resultant from the tank wall performance investigation. The vessel with the pyramid joint is determined to have failed in the joint area at a hydrostatic pressure 33% value below predicted failure. The vessel with the inverted pyramid joint failed in the wall acreage at a hydrostatic pressure within 10% of the actual failure pressure.

Verhage, Joseph M.↗

Blood vessel adaptation to gravity in a semi-arboreal snake

The effects of vasoactive agonists on systemic blood vessels were examined with respect to anatomical location and gravity acclimation in the semi-arboreal snake, Elaphe Obsoleta. Major blood vessels were reactive to putative neurotransmitters, hormones or local factors in vessel specific patterns. Catecholamines, adenosine triphosphate, histamine and high potassium (80 mM) stimulated significantly greater tension per unit vessel mass in posterior than anterior arteries. Anterior vessels were significantly more sensitive to catecholamines than midbody and posterior vessels. Angiotensin II stimulated significantly greater tension in carotid artery than in midbody and posterior dorsal aorta. Arginine vasotocin strongly contracted the left and right aortic arches and anterior dorsal aorta. Veins were strongly contracted by catecholamines, high potassium and angiotensin II, but less so by adenosine triphosphate, arginine vasotocin and histamine. Precontracted vessel were relaxed by acetylcholine and sodium nitroprusside, but not by atrial natriuretic peptide or bradykinin. Chronic exposure of snakes to intermittent hypergravity stress ( + 1.5 Gz at tail) did not affect the majority of vessel responses. These data demonstrate that in vitro tension correlates with that catecholamines, as well as other agonists, are important in mediating vascular responses to gravitational stresses in snakes.

NASA Discipline Number 14-10↗

Microgravity Storage Vessels and Conveying-Line Feeders for Cohesive Regolith

Under microgravity, the usual methods of placing granular solids into, or extracting them from, containers or storage vessels will not function. Alternative methods are required to provide a motive force to move the material. New configurations for microgravity regolith storage vessels that do not resemble terrestrial silos, hoppers, or tanks are proposed. The microgravity-compatible bulk-material storage vessels and exit feed configurations are designed to reliably empty and feed cohesive material to transfer vessels or conveying ducts or lines without gravity. A controllable motive force drives the cohesive material to the exit opening(s), and provides a reliable means to empty storage vessels and/or to feed microgravity conveying lines. The proposed designs will function equally well in vacuum, or inside of pressurized enclosures. Typical terrestrial granular solids handling and storage equipment will not function under microgravity, since almost all such equipment relies on gravity to at least move material to an exit location or to place it in the bottom of a container. Under microgravity, there effectively are no directions of up or down, and in order to effect movement of material, some other motive force must be applied to the material. The proposed storage vessels utilize dynamic centrifugal force to effect movement of regolith whenever material needs to be removed from the storage vessel. During simple storage, no dynamic motion or forces are required. The rotation rate during emptying can be controlled to ensure that material will move to the desired exit opening, even if the material is highly cohesive, or has acquired an electrostatic charge. The general concept of this Swirl Action Utilized for Centrifugal Ejection of Regolith (SAUCER) microgravity storage unit/dynamic feeder is to have an effective slot-hopper (based on the converging angles of the top and bottom conical section of the vessel) with an exit slot around the entire periphery of the SAUCER. The basic shape of such a unit is like two Chinese straw hats (douli) - one upside down, on the bottom, and another on top; or two wokpans, one upright on the bottom and another inverted on top, with a small gap between the upright and inverted pans or hats (around the periphery). A stationary outer ring, much like an unmounted bicycle tire, surrounds the gap between the two coaxial, nearly conical pieces, forming the top and bottom of the unit.

Walton, Otis R.↗

High temperature thermal properties for metals used in LWR vessels

Because of the impact that melt relocation and vessel failure has on subsequent progression and associated consequences of an Light Water Reactor (LWR) accident, it is important to accurately predict the heatup and relocation of materials within the reactor vessel and heat transfer to and from the reactor vessel. Accurate predictions of such heat transfer phenomena require high temperature thermal properties. However, a review of vessel and structural steel material properties in severe accident analysis codes reveals that the required high temperature material properties are extrapolated, with little if any, data above 700 ºC. To reduce uncertainties in predictions relying upon this extrapolated high temperature data, INL obtained data using laser-flash thermal diffusivity techniques for two metals used in LWR vessels: SA533B1 carbon steel, which is used to fabricate most US LWR reactor vessels; and SS304, which is used in LWR vessel piping, penetration tubes, and internal structures. This paper summarizes the new data, compares it to existing data in the literature, and provides recommended correlations for thermal properties based on this data.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Likelihood of a marine vessel accident from wind energy development in the Atlantic: Likelihood of shipping accident from wind energy in the Atlantic

Offshore wind energy development is planned for areas off the Atlantic coast. Many of the planned wind development areas fall within traditional commercial vessel routes. In order to mitigate possible hazards to ships and to wind turbines, it is important to understand the potential for increased risk to commercial shipping from the presence of wind farms. Using Automatic Identification System (AIS) data, historical shipping routes between ports in the Atlantic were identified, from Maine to the Florida Straits. The AIS data were also used as inputs to a numerical model that can simulate cargo, tanker and tug/towing vessel movement along typical routes. The model was used to recreate present day vessel movement, as well as to simulate future routing that may be required to avoid wind farms. By comparing the present and future routing of vessels, a risk analysis was carried out to determine the increased marginal risk of vessel collisions, groundings, and allisions with stationary objects, due to the presence of wind farms. The outcome of the analysis showed little increase in vessel collisions or allisions, and a decrease in groundings as more vessels were forced seaward by the wind farms.

commercial shipping↗

Thermal Expansion Coefficient of Steels Used in LWR Vessels

Because of the impact that melt relocation and vessel failure have on subsequent progression and associated consequences of a Light Water Reactor (LWR) accident, it is important to accurately predict the heat-up and relocation of materials within the reactor vessel and heat transfer to and from the reactor vessel. Accurate predictions of such heat transfer phenomena require high temperature thermal properties. However, a review of vessel and structural steel material properties in severe accident analysis codes reveals that the required high temperature material properties are extrapolated with little, if any, data above 700ºC. To reduce uncertainties in predictions relying upon this extrapolated high temperature data, new thermal expansion data were obtained using pushrod dilatometry techniques for two metals used in LWR vessels: SA 533 Grade B, Class 1 (SA533B1) low alloy steel, which is used to fabricate most US LWR reactor vessels; and Type 304 Stainless Steel (SS304), which is used in LWR vessel piping, penetration tubes, and internal structures. This paper summarizes the new data and compares it to existing, lower temperature data in the literature.

36 MATERIALS SCIENCE↗

A Novel Design for Improving the Control on the Stainless-Steel Vessel Welding Process for Superconducting Magnets

Stainless steel vessels see widespread use in superconducting magnets for particle accelerator applications. Their function varies in different magnet designs: they always provide the necessary liquid helium containment, but in some cases are also used to provide azimuthal prestress and can also be welded to the magnet end plate to provide additional longitudinal stiffness. A magnet designed with the bladder and key technology does not rely on the structural role of the vessel. They are structurally supported using azimuthally prestressed aluminum shells, and the longitudinal constraint by rods. In this case, the magnet designer would generally like to minimize the interaction between the magnet and the stainless-steel vessel and to minimize the coil stress variation due to the vessel. The stress state in the vessel and in the coil is a function of the circumferential interference, defined as the vessel azimuthal length minus the magnet circumference. The vessel and the magnet azimuthal length machining tolerances are relatively large resulting in significant stress variations in the superconducting coils. Here in this paper we introduce an interference-control shim, which can significantly limit the stress variation of the coils for a given variation of the interference. The effectiveness of the interference-control shim is evaluated numerically on the MQXF, the low-β quadrupole for the High Luminosity LHC.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The impact of including spatially longitudinal heterogeneities of vessel oxygen content and vascular fraction in 3D tumor oxygenation models on predicted radiation sensitivity

Purpose: Oxygen distribution models have been used to analyze the influences of oxygen tensions on tissue response after radiotherapy. These distributions are often generated assuming constant oxygen tension in the blood vessels. However, as red blood cells progress through the vessels, oxygen is continuously released into the plasma and the surrounding tissue, resulting in longitudinally varying oxygen levels in the blood vessels. In the present study, the authors investigated whether a tumor oxygenation model that incorporated longitudinally varying oxygen levels would provide different predictions of necrotic fractions and radiosensitivity compared to commonly used models with a constant oxygen pressure. Methods: Our models simulated oxygen diffusion based on a Green's function approach and oxygen consumption according to the Michaelis-Menten equation. The authors constructed tumor models with different vascular fractions (VFs), from which they generated depth oxygenation curves and a look-up table of oxygen pressure gradients. The authors evaluated models of spherical tumors of various sizes, from 1 to 10{sup 4} mg. The authors compared the results from a model with constant vessel oxygen (CVO) pressure to those from models with longitudinal variations in oxygen saturation and either a constant VF (CVF) or variable VF (VVF) within the tumor tissue. The authors monitored the necrotic fractions, defined as tumor regions with an oxygen pressure below 1 mmHg. Tumor radiation sensitivity was expressed as D{sub 99,} the homogeneous radiation dose required for a tumor control probability of 0.99. Results: In the CVO saturation model, no necrosis was observed, and decreasing the VF could only decrease the D{sub 99} by up to 10%. Furthermore, the D{sub 99} vs VF dependence was similar for different tumor masses. Compared to the CVO model, the extended CVF and VVF models provided clearly different results, including pronounced effects of VF and tumor size on the necrotic fraction and D{sub 99}, necrotic fractions ranging from 0% to 97%, and a maximal D{sub 99} increment of 57%. Only minor differences were observed between different vessel architectures, i.e., CVF vs VVF. In the smallest tumor with a low necrotic fraction, the D{sub 99} strictly decreased with increasing blood velocity. Increasing blood velocity also decreased the necrotic fraction in all tumor sizes. VF had the most profound influence on both the necrotic fraction and on D{sub 99}. Conclusions: Our present analysis of necrotic formation and the impact of tumor oxygenation on D{sub 99} demonstrated the importance of including longitudinal variations in vessel oxygen content in tumor models. For small tumors, radiosensitivity was particularly dependent on VF and slightly dependent on the blood velocity and vessel arrangement. These dependences decreased with increasing tumor size, because the necrotic fraction also increased, thereby decreasing the number of viable tumor cells that required sterilization. The authors anticipate that the present model will be useful for estimating tumor oxygenation and radiation response in future detailed studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

NASA Ground-based Layered Pressure Vessels Materials Report

A significant portion of Layered Pressure Vessels (LPVs) manufactured for NASA in the 1950s and ’60s are of non-code construction. These vessels were constructed to the standards of individual manufacturers rather than an industry or consensus standard and often contain legacy or proprietary materials, which have poor or no characterization. Obtaining correct material properties is the first step in assuring vessel safety and predicting life and critical failure modes before they happen. This report details the efforts of the LPV Project related to material properties and characterization. The goal in testing materials from deconstructed vessels was to provide material characterization utilizing modern test methods that would give a strong probabilistic base as an option for future analysis. ASTM E1820, Standard Test Method for Measurement of Fracture Toughness was used for fracture toughness; ASTM E1921, Standard Test Method for Determination of Reference Temperature, T0, for Ferritic Steels in the Transition Range for transition temperature; and ASTM E647, Standard Test Method for Measurement of Fatigue Crack Growth Rates for fatigue crack growth. Particular focus was placed on determination of transition temperature through evaluation of the T0 reference temperature in accordance with ASTM E1921. Transition temperature testing allows for a probabilistic analysis of vessel materials that may be operating at temperatures below the transition from ductile tearing to brittle cleavage failure. This test method was not available at the time of construction and has proved invaluable to the characterization of older ferritic steels. The values reported are specific to the largest body of materials found in the current NASA fleet, but do not claim to be all inclusive. As demonstrated in this report, some materials contain extreme lot-to-lot variability. In some cases, this can be comfortably bounded by worst case probabilistic methods, however it is always recommended that vessel specific data be collected in as much depth as possible to ensure correct assumptions and avoid unduly restricting vessel usage.

Layered Pressure Vessel↗

Blockade of FLT4 suppresses metastasis of melanoma cells by impaired lymphatic vessels

The metastatic spread of tumor cells via lymphatic vessels affects the relapse of tumor patients. New lymphatic vessel formation, including lymphangiogenesis, is promoted in the tumor environment. The lymphangiogenic factor VEGF-C can mediate lymphatic vessel formation and induce tumor metastasis by binding with FLT4. In melanoma, metastasis via lymphatics such as lymph nodes is one of the main predictors of poor outcome. Thus, we investigated whether blockade of FLT4 can reduce metastasis via the suppression of lymphatic capillaries. Proliferative lymphatic capillaries in melanoma were estimated by immunohistochemistry using FLT4 antibody after the injection of the FLT4 antagonist MAZ51. The numbers of tumor modules in metastasised lungs were calculated by gross examination and lymphatic related factors were examined by qRT-PCR. MAZ51 injection resulted in the suppression of tumor size and module number and the inhibition of proliferative lymphatic vessels in the intratumoral region in the lung and proliferating melanoma cells in the lung compared to those of untreated groups. Additionally, high FLT4 and TNF-alpha were detected in melanoma-induced tissue, while lymphatic markers such as VEGF-C, FLT4 and Prox-1 were significantly decreased in MAZ51 treated groups, implying that anti-lymphangiogenesis by MAZ51 may provide a potential strategy to prevent tumor metastasis in melanoma and high number of lymphatic capillaries could be used diagnosis for severe metastasis. - Highlights: • Tumor metastasis is closely involved with lymphatic vessels. • Metastatic melanoma cells rapidly migrate into lung via lymphatic vessels. • FLT4 antagonist, MAZ51 can induce impaired lymphatic endothelial cells without proliferation. • Melanoma metastasis into lung is inhibited by the suppression of FLT4-expressing lymphatic vessels, when MAZ51 treated.

60 APPLIED LIFE SCIENCES↗

Automated remote sensing tools to counter illicit maritime activity: vessel detection, bathymetry and topography from WorldView imagery

Illicit maritime activity, such as piracy and smuggling, is a global issue that often occurs in areas where interdiction authorities are sparse, ground-based monitoring technologies like radar lack range and coverage, and dark vessels abound. Our objective was to assess vessel congregation patterns, identify likely beaching areas based on terrain maps, and use them to narrow the search for potential smuggling transfer and overland routes in a specific region along the Puntland coast of Somalia. To accomplish this goal, we developed automated protocols applied to WorldView satellite imagery for (1) vessel detection and size classification, (2) shallow-water bathymetric characterization, and (3) coastal topography mapping. Utilizing a single sensor for vessel detection and topographic and bathymetric extraction at high spatial resolution and at a high re-visit rate provides a simplification to near-shore characterization for monitoring purposes. The extracted topography and bathymetry are then presented as a single, comprehensive perspective of a coastal region. The vessel-detection algorithm identified all vessels larger than approximately 15 metres in length (35 of 35), but misidentified six artefacts (i.e. false positives), resulting in an overall accuracy of 85%. The combined vessel and terrain maps facilitated the identification of a potential beaching and overland transportation route location.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Confinement Vessel Assay System: Design and Implementation Report

Los Alamos National Laboratory has a number of spherical confinement vessels remaining from tests involving nuclear materials. These vessels have an inner diameter of 6 feet with 1- to 2-inch thick steel walls. The goal of the Confinement Vessel Disposition (CVD) project is to remove debris and reduce contamination inside the vessels. We have developed a neutron assay system for the purposes of Materials Control and Accountability (MC&A) measurements of the vessel prior to and after cleanout. We present our approach to confronting the challenges in designing, building, and testing such a system. The system was designed to meet a set of functional and operational requirements. A Monte Carlo model was developed to aid in optimizing the detector design as well as to predict the systematic uncertainty associated with confinement vessel measurements. Initial testing was performed to optimize and determine various measurement parameters, and then the system was characterized using 252 Cf placed a various locations throughout the measurement system. Measurements were also performed with a 252 Cf source placed inside of small steel and HDPE shells to study the effect of moderation. These measurements compare favorably with their MCNPX model equivalent, making us confident that we can rely on the Monte Carlo simulation to predict the systematic uncertainty due to variations in response to material that may be localized at different points within a vessel.

36 MATERIALS SCIENCE↗

Salt Vessel-Sample Generator Interface

The goal of the salt sampling program at Argonne is to develop and deploy automated molten salt sampling approaches for interfacing relevant unit operations with salt analysis to improve the timeliness and accuracy of sampling-based accountancy measurements. One technology under development is a vacuum sampler loop module. In this system, molten salt is drawn from a process vessel through a heated sampling line and into a charge vessel. Next, one or more samples are split from the volume in the charge vessel and the remaining salt is returned to the process. The vacuum sampler loop module is being developed to interface with other sample processing and analysis modules to enable rapid at-line sample characterization. The main purpose of the vacuum sampling loop module is to enable the collection of samples that are more representative of the bulk salt by replacing traditional point samplers (i.e., dip probes) with a sampling approach that captures a larger cross section of salt. Additionally, the vacuum sampling approach eliminates the risk of dross contamination of samples and avoids the use of moving parts in the salt. Two methods of interfacing the vacuum sampling loop with a precision pneumatic sample generator were investigated in FY21. This report covers the testing of fluidic coupling between the two modules. Two iterations of the fluidically coupled modules were tested. The first iteration system coupled the two modules using a freeze valve to seal the vacuum sampler during filling and to control flow into the pneumatic sample generator. While this integrated system functioned as intended, some changes were implemented to make the system more robust and better suited to remote deployment. Specifically, the system was made to be more modular and active control of the vacuum filling operation was replaced with a passive control mechanism. For passive filling, the salt charge vessel was vented to a small gas tank that was at negative pressure, causing salt to be drawn into the vessel until the force of the fluid head was in equilibrium with the gas pressure. The passive control system performed well and will be used in future iterations. Another change in the second system was a newly configured pneumatic sample generator in which sample ejection occurred through a hole in the reservoir’s stainless-steel side wall instead of through a non-wetted sapphire orifice on the bottom. This alternate configuration may be better suited for near-process deployment because it enables on-line orifice maintenance and an orifice bypass drain back to the process. A third change in the second iteration system was the transition to a two-chamber charge vessel which split off a fraction of the sampled salt as a liquid aliquot. The goal was to create a buffer mechanism that would allow reproducible aliquoting of samples, independently of variability in the charge vessel fill height. While the two-chamber design was functional, the sample size reproducibility was below target values. To improve reproducibility and overcome many of the impediments to remote deployment of the vacuum sampling loop module, separate work was conducted to replace the two-chamber liquid aliquoting mechanism with aliquoting into single-use sample tubes. Solid salt transfer in the sample tubes will replace fluidic coupling for integrating the vacuum sampler with downstream modules. Because the proposed operations can all be executed with simple overhead actuation mechanisms or other existing hot-cell technology, there will be no need for large investments in novel hot cell sample handling technologies using this alternate approach. As such, near-term deployment of the vacuum sampling technology will be achievable. This new approach for automated coupling of sample tubes with down-stream modules is covered in a separate FY21 report, and a remotely operated version of the vacuum sampler loop module with the tube aliquoting feature is planned for FY22.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Carbon fiber internal pressure vessels

Internal pressure vessels were designed; the filament was wound of carbon fibers and epoxy resin and tested to burst. The fibers used were Thornel 400, Thornel 75, and Hercules HTS. Additional vessels with type A fiber were made. Polymeric linears were used, and all burst testing was done at room temperature. The objective was to produce vessels with the highest attainable PbV/W efficiencies. The type A vessels showed the highest average efficiency: 2.56 x 10 to the 6th power cm. Next highest efficiency was with Thornel 400 vessels: 2.21 x 10 to the 6th power cm. These values compare favorably with efficiency values from good quality S-glass vessels, but strains averaged 0.97% or less, which is less than 1/3 the strain of S-glass vessels.

Simon, R. A.↗

Organic fiber/epoxy pressure vessels

We evaluated the performance of an organic fiber in an epoxy matrix by winding 20-cm diam spherical and cylindrical pressure vessels of various designs. For the spherical vessels, we used soft aluminum liners 0.76 mm thick for a double boss design and 2 mm thick for a single boss design. For the cylindrical vessels, we used both 0.5-mm rubber liners and 0.76-mm soft aluminum liners. Vessels of both types were tested for burst pressure and cyclic fatigue at room temperature and liquid hydrogen temperature. The effects of temperature and vessel shape on the vessel performance factor were negligible. Our vessel fatigue data were marred by premature failure of the liners.

Chiao, T. T.↗