Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “variable resistance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Detecting impacts of surface development near weather stations since 1895 in the San Joaquin Valley of California

Abstract Temperature readings observed at surface weather stations have been used for detecting changes in climate due to their long period of observations. The most common temperature metrics recorded are the daily maximum (TMax) and minimum (TMin) extremes. Unfortunately, influences besides background climate variations impact these measurements such as changes in (1) instruments, (2) location, (3) time of observation, and (4) the surrounding artifacts of human civilization (buildings, farms, streets, etc.) Quantifying (4) is difficult because the surrounding infrastructure, unique to each site, often changes slowly and variably and is thus resistant to general algorithms for adjustment. We explore a direct method of detecting this impact by comparing a single station that experienced significant development from 1895 to 2019, and especially since 1970, relative to several other stations with lesser degrees of such development (after adjustments for the (1) to (3) are applied). The target station is Fresno, California (metro population ~ 15,000 in 1900 and ~ 1 million in 2019) situated on the eastern side of the broad, flat San Joaquin Valley in which several other stations reside. A unique component of this study is the use of pentad (5-day averages) as the test metric. Results indicate that Fresno experienced + 0.4 °C decade −1 more nighttime warming (TMin) since 1970 than its neighbors—a time when population grew almost 300%. There was little difference seen in TMax trends between Fresno and non-Fresno stations since 1895 with TMax trends being near zero. A case is made for the use of TMax as the preferred climate metric relative to TMin for a variety of physical reasons. Additionally, temperatures measured at systematic times of the day (i.e., hourly) show promise as climate indicators as compared with TMax and especially TMin (and thus TAvg) due to several complicating factors involved with daily high and low measurements.

54 ENVIRONMENTAL SCIENCES↗

A study of spectrum fatigue crack propagation in two aluminum alloys. 2: Influence of microstructures

The important metallurgical factors that influence both constant amplitude and spectrum crack growth behavior in aluminum alloys were investigated. The effect of microstructural features such as grain size, inclusions, and dispersoids was evaluated. It was shown that a lower stress intensities, the I/M 7050 alloy showed better fatigue crack propagation (FCP) resistance than P/M 7091 alloy for both constant amplitude and spectrum testing. It was suggested that the most important microstructural variable accounting for superior FCP resistance of 7050 alloy is its large grain size. It was further postulated that the inhomogenous planar slip and large grain size of 7050 limit dislocation interactions and thus increase slip reversibility which improves FCP performance. The hypothesis was supported by establishing that the cyclic strain hardening exponent for the 7091 alloy is higher than that of 7050.

Telesman, J.↗

Experimental Investigation of a Graphite-Composite Intertank Section for a Reusable Launch Vehicle

The use of graphite-composites as primary structure is essential for the development of a cost effective single-stage-to-orbit reusable launch vehicle (RLV). A full-scale segment of a graphite-composite intertank was designed and fabricated by an industry team and tested at NASA Langley Research Center as a part of the RLV technology development program. The intertank test component was approximately 3.0 m long by 6.7 m wide and included slightly less than a 90deg section of a cylindrical intertank. The test article was fabricated using graphite-bismaelimide composite material and consisted of a hat-stiffened skin with five ring frames. The stiffeners were secondarily bonded to the panel skin and the ring frames were mechanically attached. The test article was loaded to failure with a uniform compression load applied by 21 individually controlled hydraulic actuators. Resistance strain gages, linear variable differential transformers and video cameras were used to measure and record the test results. A linear f d t e element analysis of the test article and test fixture was performed. The test results verified the structural integrity cf the intertank test article up to the design limit load. However, the test article failed in general skin buckling between the ring frames at a load 1.08 times design limit load. This load was considerably lower than the expected failure load. The cause of premature failure is being investigated. Good correlation of the test and analysis results was obtained for loads up to the design limit load.

Sawyer, James Wayne↗

Impact resistance of unidirectional fiber composites.

Composite micromechanics and macromechanics and the miniature Izod impact test are used to investigate the impact resistance of unidirectional composites. Several composite systems are examined both theoretically and experimentally. The composites are classified theoretically with respect to their impact resistance for longitudinal, transverse, and shear modes. Experimental results are reported only for Izod impact with the fibers either parallel or transverse to the cantilever longitudinal axis. Impact resistance design criteria which evolved during this investigation are used to design hybrid composites with improved impact resistance. The results show that in situ fiber and matrix elongation to fracture, matrix modulus, fabrication process, fiber and void volume ratios, and microresidual stresses are variables which affect the impact resistance.

Chamis, C. C.↗

The Drag of C Class Airship Hull with Varying Length of Cylindric Midships

A model of the C class airship hull, when severed at its major section and provided with a cylindric mid-body of variable length, had its air resistance increased about in proportion to the length of the mid-body up to 3 diameters, and in about the manner to be expected from the increase of skin friction on this variable length. For greater length the drag increased less and less rapidly.

Zahm, A F↗

Disruption of the tagF Orthologue in the epa Locus Variable Region of Enterococcus faecalis Causes Cell Surface Changes and Suppresses an eep -Dependent Lysozyme Resistance Phenotype

The disease-producing capacity of the opportunistic pathogen Enterococcus faecalis is enhanced by the ability of the bacterium to evade killing by antimicrobial agents. Survival of E. faecalis in the presence of the human antimicrobial enzyme lysozyme is mediated in part by the site 2 metalloprotease Eep; however, a complete model of enterococcal lysozyme resistance has not been elucidated. To better understand the molecular basis for lysozyme resistance in E. faecalis, we analyzed Δeep suppressor mutants that acquire resistance to lysozyme through mutation of the gene OG1RF_11713, a predicted teichoic acid biosynthesis-encoding gene located within the variable region of the enterococcal polysaccharide antigen (epa) locus. Sequence comparisons revealed that OG1RF_11713 is most similar to the cytidine-5'-diphosphate (CDP)-glycerol:poly-(glycerolphosphate)glycerophosphotransferase TagF from Staphylococcus epidermidis. Inactivation of OG1RF_11713 in both the wild-type and Δeep genetic backgrounds was sufficient to increase the resistance of E. faecalis OG1RF to lysozyme. Minimal amounts of N-acetylgalactosamine were detectable in cell wall carbohydrate extracts of OG1RF_11713 deletion mutants, and this was associated with a reduction in negative cell surface charge. Targeted disruption of OG1RF_11713 was also associated with increased susceptibility to the antibiotic polymyxin B and membrane-targeting detergents and decreased susceptibility to the lantibiotic nisin. Furthermore, this work implicates OG1RF_11713 as a major determinant of cell envelope integrity and provides further validation that lysozyme resistance is intrinsically linked to the modification of enterococcal cell wall polysaccharides.

59 BASIC BIOLOGICAL SCIENCES↗

RF-source resistance meters

Several embodiments of RF source resistance measuring devices are disclosed. Common to all embodiments in the feature of the inclusion of at least one variable resistor, and a peak readout meter. In one embodiment, two ganged unloaded potentiometers are employed while another embodiment comprises an automaticnulling RF power bridge circuit with a variable rather than a fixed bridge reference resistance. A third embodiment comprises a calorimeter with a varible rather than a fixed resistor, while in another embodiment attenuator pads with variable resistors are employed.

Oakley, E. C.↗

Enhanced Multi-Dimensional Inversion Through Target-Specific Inversion Parameter Bounds With an Application to Crosswell Electromagnetic for Sequestration Monitoring

In geophysical inversions, lower and upper model parameter bounds are a means of solution stabilization. Further, constraints that intend to let only geologically plausible inverse solutions pass are amenable to lower and upper bounds. Reliable prior information is paramount to construct such bound constraints. It is common practice to narrow and widen bound intervals for regions of, respectively, more and less certain prior information. Contrary to this practice, we experiment with widened bound intervals in zones that are poorly resolved by a given survey configuration but where prior information would suggest structural anomalies of interest. The purpose of enlarged parameter bounds that correlate spatially with predefined targets is to let the inversion explore a larger solution space, thus increasing the potential to resolve otherwise hidden anomalies. Application of the method is based on a carbon-sequestration baseline (pre-injection) crosswell electromagnetic (EM) field survey at the Containment and Monitoring Institute Field Research Station (Alberta, Canada), where impeded measurements led to generally reduced sensitivities for the interwell region. Synthetic-data proofs of concept use augmented bounds designed to boost the resolution of artificial plume targets, indicating an enhanced illumination compared to constant bounds. Comparative field data inversions with spatially variable bounds constructed from prior resistivity and velocity information highlight non-horizontal baseline structures.

3-D electrical resistivity imaging↗

LVDT gage for fracture-toughness tests in liquid hydrogen

Linear-variable differential transformer replaces conventional resistance strain gages to measure crack-mouth-opening displacement. LVDT is superior in tests under liquid hydrogen, where boiling of hydrogen on resistive is suited to broad temperature range and hostile environments such as nuclear reactors.

Pierce, W. S.↗

The role of plasma wave turbulence in the formation of shock waves in collisionless plasmas

A data set containing measurements for approximately 100 shock crossings was compiled, and plasma wave profiles were plotted in conjunction with magnetic field data. Three emissions analyzed include upstream electron plasma oscillations, ion acoustic noise, and low frequency electromagnetic noise. The data demonstrate that the observed waves are consistent with generation by the kinetic cross-field streaming instability. Reanalysis of shock overshoots prompted by the presence of plasma feet upstream of nominally subcritical shocks leads to the conclusion that no firm evidence exists for a sharp subcritical supercritical transition. Electron plasma oscillations persist up to the ramps of subcritical shocks and begin decaying at the front edge of the feet of supercritical shocks. Their intensity is anticorrelated with the amplitude of the foot ion acoustic noise. Wave measurements support the predicted predominance of lower hybrid-like modes over ion acoustic noise in the production of resistive (plasma) heating. Evidence for variable shock normal angles is seen upstream from nominally quasiparallel shocks. The first cases of very strong electron heating observed at the terrestrial bow shock were discovered.

Mellott, M. M.↗

Baroreflex-mediated heart rate and vascular resistance responses 24 h after maximal exercise

INTRODUCTION: Plasma volume, heart rate (HR) variability, and stimulus-response relationships for baroreflex control of forearm vascular resistance (FVR) and HR were studied in eight healthy men after and without performing a bout of maximal exercise to test the hypotheses that acute expansion of plasma volume is associated with 1) reduction in baroreflex-mediated HR response, and 2) altered operational range for central venous pressure (CVP). METHODS: The relationship between stimulus (DeltaCVP) and vasoconstrictive reflex response (DeltaFVR) during unloading of cardiopulmonary baroreceptors was assessed with lower-body negative pressure (LBNP, 0, -5, -10, -15, -20 mm Hg). The relationship between stimulus (Deltamean arterial pressure (MAP)) and cardiac reflex response (DeltaHR) during loading of arterial baroreceptors was assessed with steady-state infusion of phenylephrine (PE) designed to increase MAP by 15 mm Hg alone and during application of LBNP (PE+LBNP) and neck pressure (PE+LBNP+NP). Measurements of vascular volume and autonomic baroreflex responses were conducted on two different test days, each separated by at least 1 wk. On one day, baroreflex response was tested 24 h after graded cycle exercise to volitional exhaustion. On another day, measurement of baroreflex response was repeated with no exercise (control). The order of exercise and control treatments was counterbalanced. RESULTS: Baseline CVP was elevated (P = 0.04) from a control value of 10.5 +/- 0.4 to 12.3 +/- 0.4 mm Hg 24 h after exercise. Average DeltaFVR/DeltaCVP during LBNP was not different (P = 0.942) between the exercise (-1.35 +/- 0.32 pru x mm Hg-1) and control (-1.32 +/- 0.36 pru x mm Hg-1) conditions. However, maximal exercise caused a shift along the reflex response relationship to a higher CVP and lower FVR. HR baroreflex response (DeltaHR/DeltaMAP) to PE+LBNP+NP was lower (P = 0.015) after maximal exercise (-0.43 +/- 0.15 beats x min-1 x mm Hg-1) compared with the control condition (-0.83 +/- 0.14 beats x min-1 x mm Hg-1). CONCLUSION: Expansion of vascular volume after acute exercise is associated with altered operational range for CVP and reduced HR response to arterial baroreceptor stimulation.

Non-NASA Center↗

Development of rapidly solidified oxidation resistant alloys

The development of iron-base alloys that contain low concentrations of expensive and/or strategic metals, but that are very resistant to oxidation at elevated tempratures was investigated. Rapid solidification processing was employed to make alloys that are uniform in composition, that comprise very fine grains 10 microns and that contain a uniform dispersion of very fine ( 0.5 microns) nonmetallic inclusions. Each of these factors contribute to the oxidation behavior of alloys. The compositional and processing variables that yield the optimum oxidation resistance are described.

Yurek, G. J.↗

Heat pipe heat rejection system

A prototype of a battery heat rejection system was developed which uses heat pipes for more efficient heat removal and for temperature control of the cells. The package consists of five thermal mock-ups of 100 amp-hr prismatic cells. Highly conductive spacers fabricated from honeycomb panels into which heat pipes are embedded transport the heat generated by the cells to the edge of the battery. From there it can be either rejected directly to a cold plate or the heat flow can be controlled by means of two variable conductance heat pipes. The thermal resistance between the interior of the cells and the directly attached cold plate was measured to be 0.08 F/Watt for the 5-cell battery. Compared to a conductive aluminum spacer of equal weight the honeycomb/heat pipe spacer has approximately one-fifth of the thermal resistance. In addition, the honeycomb/heat pipe spacer virtually eliminates temperature gradients along the cells.

Kroliczek, E. J.↗

In situ deposits of copper and copper oxide containing condensation polyimide films

Novel copper-polyimide composites have been synthesized via simultaneous thermal decomposition of solid solutions of bis (trifluoroacetylacetonato) copper (II) and thermal cyclodehydration of polyimide acid. In contrast to conventional filled polymer composites which are prepared by dispersion of particles or fibers in a polymer matrix this study has yielded in general uniform Cu or CuO dispersions of very small particle size that reside near the film surface that was exposed to the atmosphere during curing. The nature of the copper deposit, the thickness of the copper deposit, and the polyimide overlayer which bonds the copper to the polymer substrate depend on the curing atmosphere used. A variety of analytical surface methods along with thermogravimetric analysis and variable temperature (surface and volume) electrical resistivity measurements have been used to characterize these thin, flexible copper doped polyimide films.

Porta, G. M.↗

Magnetic-Field-Response Measurement-Acquisition System

A measurement-acquisition system uses magnetic fields to power sensors and to acquire measurements from sensors. The system alleviates many shortcomings of traditional measurement-acquisition systems, which include a finite number of measurement channels, weight penalty associated with wires, use limited to a single type of measurement, wire degradation due to wear or chemical decay, and the logistics needed to add new sensors. Eliminating wiring for acquiring measurements can alleviate potential hazards associated with wires, such as damaged wires becoming ignition sources due to arcing. The sensors are designed as electrically passive inductive-capacitive or passive inductive-capacitive-resistive circuits that produce magnetic-field-responses. One or more electrical parameters (inductance, capacitance, and resistance) of each sensor can be variable and corresponds to a measured physical state of interest. The magnetic-field- response attributes (frequency, amplitude, and bandwidth) of the inductor correspond to the states of physical properties for which each sensor measures. For each sensor, the measurement-acquisition system produces a series of increasing magnetic-field harmonics within a frequency range dedicated to that sensor. For each harmonic, an antenna electrically coupled to an oscillating current (the frequency of which is that of the harmonic) produces an oscillating magnetic field. Faraday induction via the harmonic magnetic fields produces an electromotive force and therefore a current in the sensor. Once electrically active, the sensor produces its own harmonic magnetic field as the inductor stores and releases magnetic energy. The antenna of the measurement- acquisition system is switched from a transmitting to a receiving mode to acquire the magnetic-field response of the sensor. The rectified amplitude of the received response is compared to previous responses to prior transmitted harmonics, to ascertain if the measurement system has detected a response inflection. The "transmit-receive-compare" of sequential harmonics is repeated until the inflection is identified. The harmonic producing the amplitude inflection is the sensor resonant frequency. Resonant frequency and response amplitude are stored and then correlated to calibration data.

Woodward, Stanley E.↗

VIIP Bedrest Analog Roadmap

The objective is to define successive bed rest campaigns leading to a potential VIIP (Vision Impairment and Intracranial Pressure) countermeasure. To determine if the analog is successful, changes need to occur in the following outcome measures (dependent variables): Intracranial pressure; Retinal nerve fiber layer; Choroidal engorgement; Globe flattening; Axial biometry; Optic nerve sheath diameter distention; Cycloplegic refraction; Visual acuity. Study parameters (independent variables) to include: CO2; Sodium; Exercise (resistive & aerobic); Strict tilt angle.

Villarreal, Jennifer D.↗

Extended Analytic Device Optimization Employing Asymptotic Expansion

Analytic optimization of a thermoelectric junction often introduces several simplifying assumptionsincluding constant material properties, fixed known hot and cold shoe temperatures, and thermallyinsulated leg sides. In fact all of these simplifications will have an effect on device performance,ranging from negligible to significant depending on conditions. Numerical methods, such as FiniteElement Analysis or iterative techniques, are often used to perform more detailed analysis andaccount for these simplifications. While numerical methods may stand as a suitable solution scheme,they are weak in gaining physical understanding and only serve to optimize through iterativesearching techniques. Analytic and asymptotic expansion techniques can be used to solve thegoverning system of thermoelectric differential equations with fewer or less severe assumptionsthan the classic case. Analytic methods can provide meaningful closed form solutions and generatebetter physical understanding of the conditions for when simplifying assumptions may be valid.In obtaining the analytic solutions a set of dimensionless parameters, which characterize allthermoelectric couples, is formulated and provide the limiting cases for validating assumptions.Presentation includes optimization of both classic rectangular couples as well as practically andtheoretically interesting cylindrical couples using optimization parameters physically meaningful toa cylindrical couple. Solutions incorporate the physical behavior for i) thermal resistance of hot andcold shoes, ii) variable material properties with temperature, and iii) lateral heat transfer through legsides.

Thermoelectric Generators↗

Utilizing 3D-DIC on Mars 2020 Rover Wheel Assembly: Test-Analysis Correlation

Following the successful implementation of full-field photogrammetry, more specifically three-dimensional Digital Image Correlation (3D-DIC), on the Mars 2020 Heat Shield Structural Failure Review assessment, 3D-DIC was selected as one of the primary measurement techniques for the Mars 2020 Rover wheel assembly qualification test at the NASA Jet Propulsion Laboratory (JPL). To validate the Rover wheel landing loads simulations, it was extremely important to have high confidence in the wheel models. Due to the large deformations and strains that the wheel would be subject to during landing, traditional instrumentation such as linear variable displacement transducers (LVDTs), electrical-resistance strain gages and string potentiometers, would not be sufficient on their own to provide all the necessary validation data. Therefore, the NASA Engineering and Safety Center (NESC) provided the 3D-DIC expertise and support to measure the high deformation and strain in the wheel flexures and qualify the overall structural response of the Mars 2020 rover wheel assembly. There were two key objectives for the photogrammetry technique: (1) monitor the wheel response in real-time, guarding against anomalous behavior and failure, and (2) provide test data for test-analysis correlation to validate and/or improve the high-fidelity computational model. The contents of this paper will focus on the challenges of applying 3D-DIC to the Mars 2020 Rover wheel assembly and how these challenges were overcome. Examples of test-analysis correlation during the stiffness characterization and structural qualification will be presented and discussed in detail. Experimental results were compared with the analysis and showed excellent agreement between the predicted behavior and helped validate the high-fidelity models.

Mars 2020 Rover Wheel↗