Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “variable capacitance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

81 records · Page 5

Plasma Flow During RF Discharges in VASIMR

The Variable Specific Impulse Magnetoplasma Rocket (VASIMR) plasma source consists of a helical antenna, driven at frequencies of 4 to 19 MHz with powers up to 1 kW, in a magnetic field up to 3 kG. Helium is the current test gas, and future experiments with hydrogen are planned. Plasma density and temperature profiles were measured by a reciprocating Langmuir probe, and plasma flow profiles were measured with a reciprocating Mach probe. Both probes were located about 0.5 m downstream from the helical antenna. The plasma source operated in capacitive and inductive modes in addition to a helicon mode. During capacitive and inductive modes, densities were low and plasma flow was < 0.5 Cs. When the plasma operated in a helicon mode, the densities measured downstream from the source were higher [10(exp 12) / cubic cm ] and plasma flow along the magnetic field was of the order Mach 1. Details of the measurements will be shown.

Jacobson, V. T.↗

Capacitance Probe Resonator for Multichannel Electrometer

A multichannel electrometer voltmeter has been developed that employs a mechanical resonator with voltage-sensing capacitance-probe electrodes that enable high-impedance, high-voltage, radiation-hardened measurement of an Internal Electrostatic Discharge Monitor (IESDM) sensor. The IESDM is new sensor technology targeted for integration into a Space Environmental Monitor (SEM) subsystem used for the characterization and monitoring of deep dielectric charging on spacecraft. The resonator solution relies on a non-contact, voltage-sensing, sinusoidal-varying capacitor to achieve input impedances as high as 10 petaohms as determined by the resonator materials, geometries, cleanliness, and construction. The resonator is designed with one dominant mechanical degree of freedom, so it resonates as a simple harmonic oscillator and because of the linearity of the variable sense capacitor to displacement, generates a pure sinusoidal current signal for a fixed input voltage under measurement. This enables the use of an idealized phase-lock sensing scheme for optimal signal detection in the presence of noise.

Blaes, Brent R.↗

A Kinematic, Flexure-based Mechanism for Precise, Parallel Motion for the Hertz Variable-delay Polarization Modulator (VPM)

We describe the design of the linear motion stage for a Variable-delay Polarization Modulator (VPM) and of a grid flattener that has been built and integrated into the Hertz ground-based, submillimeter polarimeter. VPMs allow the modulation of a polarized source by controlling the phase difference between two linear, orthogonal polarizations. The size of the gap between a mirror and a very flat polarizing grid determines the amount of the phase difference. This gap must be parallel to better than 1% of the wavelength. A novel, kinematic, flexure-based mechanism is described that passively maintains the parallelism of the mirror and the grid to 1.5 pm over a 150 mm diameter, with a 400 pm throw. A single piezoceramic actuator is used to modulate the gap, and a capacitive sensor provides position feedback for closed-loop control. A simple device that ensures the planarity of the polarizing grid is also described. Engineering results from the deployment of this device in the Hertz instrument April 2006 at the Submillimeter Telescope Observatory (SMTO) in Arizona are presented.

Voellmer, G. M.↗

bpshape wk4: a computer program that implements a physiological model for analyzing the shape of blood pressure waveforms

We describe the theory and computer implementation of a newly-derived mathematical model for analyzing the shape of blood pressure waveforms. Input to the program consists of an ECG signal, plus a single continuous channel of peripheral blood pressure, which is often obtained invasively from an indwelling catheter during intensive-care monitoring or non-invasively from a tonometer. Output from the program includes a set of parameter estimates, made for every heart beat. Parameters of the model can be interpreted in terms of the capacitance of large arteries, the capacitance of peripheral arteries, the inertance of blood flow, the peripheral resistance, and arterial pressure due to basal vascular tone. Aortic flow due to contraction of the left ventricle is represented by a forcing function in the form of a descending ramp, the area under which represents the stroke volume. Differential equations describing the model are solved by the method of Laplace transforms, permitting rapid parameter estimation by the Levenberg-Marquardt algorithm. Parameter estimates and their confidence intervals are given in six examples, which are chosen to represent a variety of pressure waveforms that are observed during intensive-care monitoring. The examples demonstrate that some of the parameters may fluctuate markedly from beat to beat. Our program will find application in projects that are intended to correlate the details of the blood pressure waveform with other physiological variables, pathological conditions, and the effects of interventions.

Non-NASA Center↗

Degradation behavior of CIGS solar Cells: A parametric analysis

A parametric study of the effect of bulk and interface properties on device characteristics as a function of heat and light stress under open-circuit and short-circuit conditions is developed for Cu(In,Ga)(S,Se) 2 solar cells using SCAPS-1D simulator. The variables and interdependencies modeled include: (1) conduction band offset (CBO) between buffer and absorber; (2) buffer ionized donor density; (3) CIGS shallow acceptor density; (4) CIGS deep acceptor density; (5) CIGS shallow donor density; (6) ionized acceptor concentration in the ordered vacancy compound (OVC) CIGS/buffer interface; and (7) back contact work-function. An increase in absorber shallow acceptor or a decrease in shallow donor density results in an increase in net carrier density and open-circuit voltage (V OC ). Further, a decrease in V OC is observed with an increase in the deep acceptors or neutral midgap defects in the CIGS due to higher charge carrier recombination. A change of CBO from spike to cliff condition is a dominant mechanism of decreasing VOC with an interface defect density of 10 12 cm -2 . The minimum depletion width is found to be specifically sensitive to CBO and interface defect density. An inflection in the capacitance–voltage curves (in reverse bias) is observed with simultaneous increase in bulk deep acceptor density and shallow donor density near the back contact.

14 SOLAR ENERGY↗

High–Performance NiCo 2 O 4 /Graphene Quantum Dots for Asymmetric and Symmetric Supercapacitors with Enhanced Energy Efficiency

For the sustainable growth of future generations, energy storage technologies like supercapacitors and batteries are becoming more and more common. However, reliable and high-performance materials’ design and development is the key for the widespread adoption of batteries and supercapacitors. Quantum dots with fascinating and unusual properties are expected to revolutionize future technologies. However, while the recent discovery of quantum dots honored with a Nobel prize in Chemistry, their benefits for the tenacious problem of energy are not realized yet. In this context, herein, chemical-composition tuning enabled exceptional performance of NiCo 2 O 4 (NCO)/graphene quantum dots (GQDs) is reported, which outperform the existing similar materials, in supercapacitors. A comprehensive study is performed on the synthesis, characterization, and electrochemical performance evaluation of highly functional NCO/GQDs in supercapacitors delivering enhanced energy efficiency. The high-performance, functional NCO/GQDs electrode materials are synthesized by the incorporation of GQDs into NCO. The effect of variable amount of GQDs on the energy performance characteristics of NCO/GQDs in supercapacitors is studied systematically. In-depth structural and chemical bonding analyses using X-ray diffraction (XRD) and Raman spectroscopic studies indicate that all the NCO/GQDs composites crystallize in the spinel cubic phase of NiCo 2 O 4 while graphene integration evident in all the NCO/GQDs. The scanning electron microscopy imaging analysis reveals homogeneously distributed spherical particles with a size distribution of 5–9 nm validating the formation of QDs. The high-resolution transmission electron microscopy analyses reveal that the NCOQDs are anchored on graphene sheets, which provide a high surface area of 42.27 m 2 g –1 and high mesoporosity for the composition of NCO/GQDs-10%. In addition to establishing reliable electrical connection to graphene sheets, the NCOQDs provide reliable 3D-conductive channels for rapid transport throughout the electrode as well as synergistic effects. Chemical-composition tuning, and optimization yields NCO/GQDs-10% to deliver the best specific capacitance of 3940 Fg –1 at 0.5 Ag –1 , where the electrodes retain ≈98% capacitance after 5000 cycles. The NCO/GQD-10%//AC asymmetric supercapacitor device demonstrates outstanding energy density and power density values of 118.04 Wh kg –1 and 798.76 W kg –1 , respectively. The NCO/GQDs-10%//NCO/GQDs-10% symmetric supercapacitor device delivers excellent energy and power density of 24.30 Wh kg –1 and 500 W kg –1 , respectively. These results demonstrate and conclude that NCO/GQDs are exceptional and prospective candidates for developing next-generation high-performance and sustainable energy storage devices.

25 ENERGY STORAGE↗

Sensitivity analysis in multipole-accelerated panel methods for potential flow

In the design of an airframe, the effect of changing the geometry on resulting computations is necessary for design optimization. The geometry is defined in terms of a series of design variables, including design variables to define the wing planform, tail, canard, pylon, and nacelle. Design optimization in this research is based on how these design variable affect the potential flow. The potential flow is computed as a function of the geometry and location of a series of panels describing the airframe, which are in turn a function of the design variables. Multipole accelerated panel methods improve the computational complexity of the problem and thus are an attractive approach. To utilize the methods in design optimization, it was necessary to define the appropriate sensitivity derivatives. The overhead incurred from finding the sensitivity derivatives in conjunction with the original computation should be small. This research developed the background for multipole-accelerated panel methods and the framework for finding sensitivity derivatives in the methods. Potential flow panel codes are commonly used for powered-lift aerodynamic predictions for three dimensional geometries. Given an airframe which has been discretized into a series of panels to define the airframe geometry, potential is computed as a function of the influence of all panels on all other panels. This is a computationally intensive problem for which efficient solutions are desired to improve the computational time and to allow greater resolution by use of more panels. One such solution is the use of hierarchical multipole methods which entail approximations of the effects of far-field terms. Hierarchical multipole methods have become prevalent in molecular dynamics and gravitational physics, and have been introduced into the fields of capacitance calculations, computational fluid dynamics, and electromagnetics. The methods utilize multipole expansions to describe the effect of bodies (i.e. particles, astrophysical bodies, panels, etc.) within a sphere on points distant from the sphere, where the influence diminishes as a function of distance. The expansions are exact with infinite series, however, for practical computations, the series are truncated and accuracy is selected based on the number of terms retained in the expansions. A hierarchical tree structure groups bodies together based on proximity to allow definition of multipole expansions for each group. The multipole expansions are then used to compute the effect of the bodies in a group on distant bodies.

Leathrum, James F., Jr.↗

COTS Ceramic Chip Capacitors: An Evaluation of the Parts and Assurance Methodologies

Commercial-Off-The-Shelf (COTS) multilayer ceramic chip capacitors (MLCCs) are continually evolving to reduce physical size and increase volumetric efficiency. Designers of high reliability aerospace and military systems are attracted to these attributes of COTS MLCCs and would like to take advantage of them while maintaining the high standards for long-term reliable operation they are accustomed io when selecting military qualified established reliability (MIL-ER) MLCCs. However, MIL-ER MLCCs are not available in the full range of small chip sizes with high capacitance as found in today's COTS MLCCs. The objectives for this evaluation were to assess the long-term performance of small case size COTS MLCCs and to identify effective, lower-cost product assurance methodologies. Fifteen (15) lots of COTS X7R dielectric MLCCs from four (4) different manufacturers and two (2) MIL-ER BX dielectric MLCCs from two (2) of the same manufacturers were evaluated. Both 0805 and 0402 chip sizes were included. Several voltage ratings were tested ranging from a high of 50 volts to a low of 6.3 volts. The evaluation consisted of a comprehensive screening and qualification test program based upon MIL-PRF-55681 (i.e., voltage conditioning, thermal shock, moisture resistance, 2000-hour life test, etc.). In addition, several lot characterization tests were performed including Destructive Physical Analysis (DPA), Highly Accelerated Life Test (HALT) and Dielectric Voltage Breakdown Strength. The data analysis included a comparison of the 2000-hour life test results (used as a metric for long-term performance) relative to the screening and characterization test results. Results of this analysis indicate that the long-term life performance of COTS MLCCs is variable -- some lots perform well, some lots perform poorly. DPA and HALT were found to be promising lot characterization tests to identify substandard COTS MLCC lots prior to conducting more expensive screening and qualification tests. The results indicate that lot- specific screening and qualification are still recommended for high reliability applications. One significant and concerning observation is that MIL- type voltage conditioning (100 hours at twice rated voltage, 125 C) was not an effective screen in removing infant mortality parts for the particular lots of COTS MLCCs evaluated.

Brusse, Jay A.↗

Role of physical countermaneuvers in the management of orthostatic hypotension: efficacy and biofeedback augmentation

OBJECTIVE: To evaluate the efficacy of various physical countermaneuvers in reducing orthostatic hypotension and its associated symptoms and to assess the efficacy of biofeedback training in enhancing the effectiveness of physical countermaneuvers. MATERIAL AND METHODS: In nine study subjects with neurogenic orthostatic hypotension, four training sessions on physical countermaneuvers were performed after tilt-up, three with visual feedback on the effect of physical countermaneuvers on blood pressure and other cardiovascular variables. Blood pressure change and orthostatic symptoms during tilt-up were determined, as were the changes in total peripheral resistance, stroke index, and heart rate. RESULTS: The five female and four male patients had a mean age of 53 years and a mean duration of symptoms of 4.2 years. On an orthostatic symptom scale of 0 to 10, these patients had a mean symptom score of 7.3. The increment in systolic blood pressure was better for some maneuvers (such as leg crossing and a combination) than others (such as neck flexion and abdominal contraction). Three patterns of responses to biofeedback were found. Simple maneuvers such as squatting did not improve with training; visual feedback was needed for maneuvers such as thigh contraction, and performance declined without biofeedback; the third pattern, seen in maneuvers such as leg crossing, showed continued improvement with training, even without biofeedback. A survey at 3 to 4 months after training revealed continued use of physical maneuvers (3.8 +/- 3.1 per day), increased standing time with each episode of presyncopal symptoms (8.3 +/- 5.8 minutes), and continued global symptomatic improvement. Total peripheral resistance, but not heart rate or stroke index, showed significant regression with blood pressure improvement. CONCLUSION: Physical countermaneuvers are efficacious in reducing orthostatic hypotension, can be augmented by use of biofeedback, and may significantly improve the functional outcome. The major mechanism of improvement is an increase in total peripheral resistance, presumably by reducing the vascular capacitance.

NASA Program Space Physiology and Countermeasures↗