Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “vapor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Vapor-Cell-Based Atomic Electrometry for Detection Frequencies below 1 kHz

Rydberg-assisted atomic electrometry using alkali-metal atoms contained inside a vacuum environment for detecting external electric fields at frequencies below a few kilohertz has been quite challenging due to the low-frequency electric-field-screening effect that is caused by the alkali-metal atoms adsorbed on the inner surface of the container. In this work, we report a very slow electric-field-screening phenomenon with a timescale up to the order of seconds on a rubidium-vapor cell that is made of monocrystalline sapphire. Furthermore, using this sapphire rubidium-vapor cell with an optically induced, internal bias electric field, we demonstrate vapor-cell-based, low-frequency atomic electrometry that responds to the electric field strength linearly. Limited by the given experimental conditions, this demonstrated atomic electrometer uses an active volume of 11 mm 3 and delivers a spectral noise floor of around 0.34 mV/m √Hz and a 3-dB low cutoff frequency of around 770 Hz inside the vapor cell. This work investigates a regime of vapor-cell-basedatomic electrometry that was seldom studied before, which may enable more applications that use atomicelectric-field-sensing technology.

74 ATOMIC AND MOLECULAR PHYSICS↗

Performance and Durability of Proton Exchange Membrane Vapor-Fed Unitized Regenerative Fuel Cells

With a growing demand for electricity, clean hydrogen production and usage can be an asset not only to mitigate emissions but for long-term energy storage as well. Hydrogen gas, a high-density energy carrier, can be made through electrolysis in charging mode and generate electricity via a fuel cell in discharging mode in a unitized regenerative fuel cell (URFC). While URFCs reduce cost by combining the charging and discharging modes into a singular device, switching between modes becomes burdensome, and water management is a major challenge. One way to mitigate these issues is to operate the entire system in the vapor phase. Vapor-phase operation simplifies the physics of the system but will introduce losses within the system, primarily ohmic and mass transport during the charging mode. In this study, we explore the performance of a Proton-Exchange-Membrane (PEM)-URFC under vapor-phase conditions and the impact of different PEMs, feed gases, and relative humidity on the performance and durability. By tailoring operating conditions and membrane, the vapor-URFC achieves a roundtrip efficiency of 42% and a lifetime of 50,000 accelerated stress test cycles for fully humidified feeds. Discussion of vapor-URFC for energy storage and extensions to look at various applications shows the promise of this technology.

25 ENERGY STORAGE↗

Polar Bear™ – Innovative Capture of Storage Tank Vapors

Polar Bear™ is a patented technology developed by the Energy & Environmental Research Center (EERC) to capture storage tank vapors and eliminate methane emissions from upstream oil- and gas-producing facilities. Sparked by early commercial investment, the EERC licensed the technology and extended the intellectual property to storage tanks. Polar Bear™ is uniquely engineered and adapted to individual lower-producing facilities where there is otherwise no economic alternative for capturing tank vapors. A high number of small producing oil and gas wells are distributed across the country. The aggregate contributes to a significant volume of emissions. Because of the lack of economy of scale, gas volumes from these facilities are typically not recovered and contribute to methane emissions. Polar Bear™ provides a fit-for-purpose compression solution that addresses cost by reducing complexity with respect to conventional vapor recovery units and eliminating oil changes. Unique to Polar Bear™ is the capability to separate oxygenated gas from storage tank vapors. Storage tanks are designed to “breathe,” allowing gas to enter and escape during internal level and temperature changes. This infiltration of air into the tank headspace imparts undesirable oxygen content with respect to pipeline gathering. Polar Bear™ separates the vapor stream, allowing oxygen-rich gas to be used as fuel on-site while recovering the liquids-rich portion of the gas where oxygen content is minimized. A prototype system was tested to verify process models, evaluate operational performance, and advance the technology readiness level from 5 to 6. Results provide a good match between experimental measurements and process models, indicating the models are useful for future scale-up and field design. Various mixtures of nitrogen and liquefied petroleum gas were tested to understand the mass balance of nitrogen and how it relates to the potential control of oxygen content. Findings indicate that less than 2000 ppm of oxygen is likely to remain in the liquid portion of the gas in field applications. The research and development prepare the technology for field implementation to eliminate routine and fugitive methane emissions from storage tanks.

02 PETROLEUM↗

The annual cycle and sources of relevant aerosol precursor vapors in the central Arctic during the MOSAiC expedition

Abstract. In this study, we present and analyze the first continuous time series of relevant aerosol precursor vapors from the central Arctic (north of 80° N) during the Multidisciplinary drifting Observatory for the Study of Arctic Climate (MOSAiC) expedition. These precursor vapors include sulfuric acid (SA), methanesulfonic acid (MSA), and iodic acid (IA). We use FLEXPART simulations, inverse modeling, sulfur dioxide (SO2) mixing ratios, and chlorophyll a (chl a) observations to interpret the seasonal variability in the vapor concentrations and identify dominant sources. Our results show that both natural and anthropogenic sources are relevant for the concentrations of SA in the Arctic, but anthropogenic sources associated with Arctic haze are the most prevalent. MSA concentrations are an order of magnitude higher during polar day than during polar night due to seasonal changes in biological activity. Peak MSA concentrations were observed in May, which corresponds with the timing of the annual peak in chl a concentrations north of 75° N. IA concentrations exhibit two distinct peaks during the year, namely a dominant peak in spring and a secondary peak in autumn, suggesting that seasonal IA concentrations depend on both solar radiation and sea ice conditions. In general, the seasonal cycles of SA, MSA, and IA in the central Arctic Ocean are related to sea ice conditions, and we expect that changes in the Arctic environment will affect the concentrations of these vapors in the future. The magnitude of these changes and the subsequent influence on aerosol processes remains uncertain, highlighting the need for continued observations of these precursor vapors in the Arctic.

Boyer, Matthew↗

The Development of Catalysts for Upgrading of Pyrolysis Vapor for Refinery Feedstocks and Intermediates: Cooperative Research and Development, CRADA Number CRD-12-00497 (Final Report)

Fast pyrolysis of biomass with vapor phase upgrading (VPU) can produce refinery feedstocks or intermediates that can meet the Department of Energy’s goal of cost-competitive hydrocarbon fuels by 2017. A key technical barrier for this technology is the lack of selective, cost effective catalysts that can produce high yields of fuel-appropriate hydrocarbons from the pyrolysis vapors. In overcoming this barrier, it will be important to engage leading catalyst development companies to devote their resources and expertise to the development of these materials. Thus, we propose a Cooperative Research and Development Agreement (CRADA) between the National Renewable Energy Laboratory (NREL), a world leader in biomass pyrolysis research and Johnson Matthey (JM), a world leader in the production of advanced catalyst materials to develop and test novel catalysts for efficient VPU. Through its Intercat Inc. subsidiary in Savannah, Ga., Johnson Matthey is internationally recognized as a leader in zeolite-based vapor phase upgrading in refinery duties and an emerging developer of biomass conversion technologies. The research and development efforts described in the proposed work will build upon existing collaborations between NREL and JM and play to the strengths of both institutions. NREL will analyze the composition of pyrolysis vapors as an input to catalyst design, screen and test catalysts, characterize the resulting oil and conduct techno-economic analysis. Catalyst samples will be produced and funded by JM. JM will design and synthesize catalysts, characterize fresh and used catalysts and develop catalyst supports needed to achieve commercially meaningful lifetimes. The project will span catalyst development and testing from the fundamental stage using quantum mechanical modeling and chemical reaction analysis to catalyst screening to integrated pilot studies.

09 BIOMASS FUELS↗

Equilibrium vapor pressure properties for absorbent and adsorbent materials

Sorption devices are important tools for the efficient utilization of fuels and waste heat. Amid a tremendous diversity of cycles and applications, all sorption systems have an equilibrium vapor pressure that depends on the sorbent temperature and composition. The vapor pressure properties of working fluids are reported in the literature in a variety of ways, which impedes wide-ranging cross comparisons or screening studies for novel applications. This work compiles equilibrium vapor pressure properties for 123 liquid absorbents with 31 absorbates and 139 solid adsorbents with 16 adsorbates. The adsorption pairs are represented with six functional forms. Additionally, most of the absorption pairs are represented with 10 functional forms, plus several that are represented with custom empirical equations. Because the functional forms used in the literature vary widely, in this work each functional form was generalized. This paper is designed to facilitate comparisons of working fluid properties for screening studies, provide a quick reference to existing research, and present a framework for standardizing the reportage of vapor pressure equilibrium data for existing and future working pairs.

36 MATERIALS SCIENCE↗

Controlling Structure and Properties of Vapor-Deposited Glasses of Organic Semiconductors: Recent Advances and Challenges

The past decade has seen great progress in manipulating the structure of vapor-deposited glasses of organic semiconductors. Upon varying the substrate temperature during deposition, glasses with a wide range of density and molecular orientation can be prepared from a given molecule. Here, we review recent studies that show the structure of vapor-deposited glasses can be tuned to significantly improve the external quantum efficiency and lifetime of organic light-emitting diodes (OLEDs). We highlight the ability of molecular simulations to reproduce experimentally observed structures, setting the stage for in silico design of vapor-deposited glasses in the coming decade. Finally, we identify research opportunities for improving the properties of organic semiconductors by controlling the structure of vapor-deposited glasses.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Disentangling the mechanism of temperature and water vapor modulation on ozone under a warming climate

Temperature and water vapor have been considered as important factors affecting ozone concentrations, however, their synergistic effect on ozone, as well as its response to a warming climate remains unclear. Here, numerical experiments with different combinations of climate and emissions highlighted opposite changes of annual ozone over the contiguous U.S. under scenarios with high vs. low ozone precursor emissions in the future with warming. Comparing the occurrence of heat waves on higher vs. lower ozone days, we found significant suppression of the heat wave exacerbation of ozone by anthropogenic emissions reductions. Variations of ozone with temperature (T) and water vapor (Q) over the western U.S. and southeastern U.S. in the simulations are clearly revealed through the construction of an O 3 -T-Q diagram. Based on the diagram, we further identified a T-dominant regime at higher temperatures where ozone increases with temperature increase, and a Q-dominant regime at lower temperatures where ozone decreases with temperature increase due to the negative effect of water vapor. With larger anthropogenic emission reductions, ozone may increase at a lower rate with temperature in the T-dominant regime, or even decrease with temperature in the Q-dominant regime. Our results show that with large emission reductions, substantial ozone pollution due to warming and increasing heat waves may be counteracted by water vapor, partly turning the ‘climate penalty’ on ozone into ‘climate benefit’. Hence controlling anthropogenic emissions may be an increasingly important strategy in a warmer and wetter climate to improve air quality and public health.

54 ENVIRONMENTAL SCIENCES↗

Improving the Estimation of the Atmospheric Water Vapor Pressure Using Interpretable Long Short-Term Memory Networks: Dataset, Python code, and trained models

Atmospheric water vapor pressure is an essential meteorological control on land surface and hydrologic processes. It is not as frequently observed as other meteorologic conditions, but often inferred through the August–Roche–Magnus formula by simply assuming dew point and daily minimum temperatures are equivalent or by empirically correlating the two temperatures using an aridity correction. The performance of both methods varies considerably across different regions and during different time periods; obtaining consistently accurate estimates across space and time remains a great challenge. We applied an interpretable Long Short-Term Memory (iLSTM) network conditioned on static, location specific attributes to estimate daily vapor pressure for 83 FLUXNET sites in the United States and Canada. This data package includes all raw data of the 83 FLUXNET sites, input data for model training/validation/test, trained models and results, and python codes for the manuscript "Improving the Estimation of the Atmospheric Water Vapor Pressure Using an Interpretable Long Short-term Memory Network". Specifically, it consists of five parts. - First, "1_Daymet_data_83sites.zip" includes raw data downloaded from Daymet for the 83 sites used in the paper according to their longitude and latitude, in which vapor pressure is used. It also includes a pre-processed CSV data file combining all data from the 83 sites which is specifically used for the paper. - Second, "2_Fluxnet2015_data_83sites.zip" includes raw half hourly data of the 83 sites downloaded from FLUXNET2015 data portal, pre-processed daily data of the 83 sites, a CSV file including combined pre-processed daily data of the 83 sites, and a CSV file including the information (site ID, site name, latitude, longitude, data available period) of the 83 sites. - Third, "3_MODIS_LAI_data_83sites_raw.zip" includes raw leaf area index (LAI) data downloaded from the AppEEARs data portal. - Fourth, "4_Scripts.zip" includes all scripts related to model training and post-processing of a trained model, and a jupyter notebook showing an example for model post-processing. Two typo errors in files titled "run2get_args.py" and "postprocess.py" were corrected on March 27, 2024 to avoid confusions. - Finally, "Trained_models_and_results.zip" includes three folders and three files with suffix ".npy", and each folder corresponds to one file with suffix ".npy" with the same title. Each of the three folders include all trained models associated with one iLSTM model configuration (35 models for each configuration, details are described in the paper). Each file with suffix ".npy" includes the post-processed results of the corresponding 35 models under one iLSTM model configuration.

54 ENVIRONMENTAL SCIENCES↗

Literature Review on Next Generation Solvent Isopar ® L Vapor Pressure Curve and the Partitioning of its Modifier and Extractant

The Next Generation Solvent (NGS) is set to replace the Original Caustic Side Solvent Extractant (CSSX) at the Salt Waste Processing Facility (SWPF). The Savannah River National Laboratory (SRNL) was requested by Savannah River Mission Completion (SRMC), formerly Savannah River Remediation (SRR), to perform a literature review on the following topics to address flammability concerns with the current solvent: Isopar ® L vapor pressure curve for NGS, partitioning ratio for the extractant MaxCalix and the modifier Cs-7SB, and high cesium concentration impacts on NGS radiolysis and potential solvent degradation rates in high cesium concentrations. The following conclusions and recommendations are made based on previous experimental work and literature: (1) Current SWPF flammable gas generation calculations use an Isopar ® L vapor pressure curve based on experimental testing with the Original CSSX solvent. No such testing to date has been performed with NGS. It is suggested that the decrease in Cs-7SB concentration for NGS compared to the Original CSSX solvent would lead to a slightly higher vapor pressure at all temperatures in SWPF vessels. A bounding NGS vapor pressure curve has been provided; it is recommended to see if these values would challenge current flammability controls and to perform testing if needed.(2) The partitioning ratio for Cs-7SB is known in the Original CSSX solvent with dilute nitric acid and caustic solutions. No tests could be found for the partitioning of Cs-7SB to dilute boric acid solutions; however, a similar partitioning ratio is expected. Due to the lipophilic alkyl chains on MaxCalix, it is expected to be even less soluble than BOBCalixC6 in the aqueous phase and should not be considered a significant contributor to the f organic term. Additionally, the reaction rate of N,N’,N’’-Tris(3,7-dimethyloctyl)guanidine (TiDG) or its degradation products with a hydrogen radical should be estimated/determined if they are found to be significant contributors to the f organic term. (3) NGS is expected to see much higher Cs concentrations at SWPF in comparison to its use at the Modular CSSX Unit (MCU). These higher Cs concentrations could influence radiolytic degradation rates of the solvent. NGS appears to be fairly stable to radiolytic degradation based on previous testing and its use at MCU. However, there has not been radiolytic flammable gas generation testing with NGS to date. There is a risk that the continued use of G-values obtained for flammable gases produced from the irradiation of the Original CSSX solvent is not bounding for NGS, but this is considered a very low risk due to the similarities in the composition of the solvents, as well as the conservatisms in the experimental design of the Original CSSX testing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Moisture Performance of Unvented Attics With Vapor Diffusion Ports and Buried Ducts in Hot, Humid Climates

Energy efficiency measures, such as cool roofs, radiant barriers, interior radiative control coatings, and buried ducts are increasing in popularity and are promoted by energy codes because of their energy-saving potential. However, these strategies can also pose moisture risks in attics by lowering surface temperatures and increasing condensation potential and moisture accumulation. Of particular concern in hot-humid climates is dripping condensation on cold air-conditioning ductwork in the summer - commonly referred to as duct "sweating" - which threatens the attic floor with conditions conducive to mold growth and rot. One strategy to mitigate these moisture issues is to wrap ductwork in thicker duct-wrap insulation with an integrated exterior vapor barrier, but thick duct wrap can be difficult to come by, expensive, and unwieldy to work with. This study explores an alternative strategy of reducing moisture issues while embracing energy efficiency by using unvented attics with vapor diffusion ports and buried ductwork in hot-humid climates. Vapor diffusion ports have been studied so far in a wide range of U.S. climates, mostly in the context of conditioned attics. In this study, the strategy is implemented in the novel context of hot-humid climates with ductwork sitting atop blown-in attic floor insulation in unconditioned attics. Using a combination of field experiments and hygrothermal modeling, the findings of this project indicate that an unvented attic with vapor diffusion ports and buried ducts may be a key part of a successful low-cost method for reducing the attic moisture load by venting excess moisture out of the attic, keeping duct-jacket surfaces above dew point temperature, and keeping the roof deck safe from winter moisture accumulation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigation of microorganisms in cannabis after heating in a commercial vaporizer

There are concerns about microorganisms present on cannabis materials used in clinical settings by individuals whose health status is already compromised and are likely more susceptible to opportunistic infections from microbial populations present on the materials. Most concerning is administration by inhalation where cannabis plant material is heated in a vaporizer, aerosolized, and inhaled to receive the bioactive ingredients. Heating to high temperatures is known to kill microorganisms including bacteria and fungi; however, microbial death is dependent upon exposure time and temperature. It is unknown whether the heating of cannabis at temperatures and times designated by a commercial vaporizer utilized in clinical settings will significantly decrease the microbial loads in cannabis plant material. To assess this question, bulk cannabis plant material supplied by National Institute on Drug Abuse (NIDA) was used to assess the impact of heating by a commercial vaporizer. Initial method development studies using a cannabis placebo spiked with Escherichia coli were performed to optimize culture and recovery parameters. Subsequent studies were carried out using the cannabis placebo, low delta-9 tetrahydrocannabinol (THC) potency and high THC potency cannabis materials exposed to either no heat or heating for 30 or 70 seconds at 190°C. Phosphate-buffered saline was added to the samples and the samples agitated to suspend the microorganism. Microbial growth after no heat or heating was evaluated by plating on growth media and determining the total aerobic microbial counts and total yeast and mold counts. Overall, while there were trends of reductions in microbial counts with heating, these reductions were not statistically significant, indicating that heating using standard vaporization parameters of 70 seconds at 190°C may not eliminate the existing microbial bioburden, including any opportunistic pathogens. When cultured organisms were identified by DNA sequence analyses, several fungal and bacterial taxa were detected in the different products that have been associated with opportunistic infections or allergic reactions including Enterobacteriaceae, Staphylococcus, Pseudomonas, and Aspergillus.

59 BASIC BIOLOGICAL SCIENCES↗

The Influence of Water Vapor on the Electrochemical Shift of an Ionic Liquid Measured by Ambient Pressure X-ray Photoelectron Spectroscopy

Ionic liquids (ILs) are considered to be one of the steppingstones to fabricate next generation electrochemical devices given their unique physical and chemical properties. The addition of water to ILs significantly impact electrochemical related properties including viscosity, density, conductivity, and electrochemical window. Here, we utilize ambient pressure X-ray photoelectron spectroscopy (APXPS) to examine the impact of water on values of the electrochemical shift (S), which is determined by measuring changes in binding energy shifts as a function of an external bias. APXPS spectra of C 1s, O 1s and N 1s regions are examined for the IL 1-butyl-3-methylimidazolium acetate, [C 4 mim][OAc], at the IL/gas interface as a function of both water vapor pressure and external bias. Results reveal that in the absence of water vapor there is an IL ohmic drop between the working electrode and quasi reference electrode, giving rise to chemical specific S values of less than one. Upon introducing water vapor, S values approach one as a function of increasing water vapor pressure, indicating a decrease in the IL ohmic drop as the IL/water mixture becomes more conductive and the potential drop is driven by the electric double layer at the electrode/IL interface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling of vapor-liquid interactions in condensing ejectors

Ejectors are compact mechanical devices that utilize the expansion of a high-pressure primary fluid to entrain and compress a low-pressure secondary fluid by means of momentum transfer between the two streams of fluid. Condensing ejectors feature both momentum and heat transfer through the interaction between the vapor and liquid streams. The goal of this paper is to develop and validate a one-dimensional slug flow model to simulate the vapor–liquid interactions in two types of condensing ejectors – one with primary liquid and secondary vapor flows (Type I), and the other with primary vapor and secondary liquid flows (Type II). Control volume analysis of the mass, momentum, and energy balance in each phase and across the interface was conducted for the ejectors. The slug flow models for both types of ejectors are validated with published results in the literature. The friction coefficient on the inner wall of the ejectors and the interfacial heat transfer coefficient are identified as controlling parameters for the ejector performance in terms of pressure and temperature distributions along the axis. The detailed parametric study shows that the liquid inlet velocity and mixing tube diameter have a significant impact on the performance of the Type I ejectors, and the performance of the Type II ejectors is mainly controlled by the secondary liquid flow inlet temperature.

42 ENGINEERING↗

Recent trends and variability of temperature and atmospheric water vapor over South Asia

This study examines the recent trends and variability of temperature and atmospheric water vapor over South Asia during the summer monsoon season from 1970 to 2022. We employ gridded reanalysis and observational datasets to assess the trends and variability in surface temperature and further investigate the associated physical processes. Our results show that the surface temperature over South Asia has increased by 0.5 °C per decade. Notably, we find a statistically significant major transition in the surface temperature series in 1995, such that 1970–1994 (1995–2022) is associated with anomalous cooling (anomalous warming). Since 1995, not only have the temporal variations in regional surface temperature, atmospheric water vapor, and clear-sky downward longwave radiation been synchronous at interannual scales, but their largest spatial variations have been located mainly over the same region. A diagnosis of the atmospheric moisture budget reveals that the observed changes in water vapor convergence over South Asia are dominated by changes in mean circulation dynamics, while the change in thermodynamics is relatively small. The enhancement of the Somali low-level jet may contribute to increased water vapor in South Asia by modulating low-level circulations.

Atmospheric circulations↗

Experiments on a vapor compression air conditioner with liquid desiccants for efficient dehumidification

Buildings require air conditioning systems that not only cool and dehumidify supply air but also provide sufficient ventilation to ensure indoor air quality and occupant comfort. However, standard recirculation systems-which introduce about a 10 % to 20 % fraction of outdoor air-often fail to deliver air that is precisely cooled and dry, particularly because 80-90 % of the ventilation cooling load is latent. Mixing humid ventilation air with recirculated indoor air increases the energy and costs required to condition the air to comfortable levels. Dedicated outdoor air systems (DOASs) are designed to handle this latent dominated ventilation load and thus need to have efficient humidity removal. Many cooling cycles can perform this task. Here we describe a liquid desiccant DOAS, which combines a vapor compression cycle and a liquid desiccant absorber and desorber pair. We present its performance at 26 operating conditions and a thermodynamic model which can accurately predict the moisture removal efficiency. The model's performance predictions have a mean percentage error of 2.5 % and a coefficient of variation of the root mean square error of 7.5 %. We also compare the performance of this vapor-compression-coupled liquid desiccant system with a standard vapor compression system with the same components but no liquid desiccant. For the 26 conditions tested in this study, this comparison shows that adding liquid desiccants lowers the required evaporator cooling load by 21 %, allows for 25 % lower compressor volumetric capacity, and 25 % lower electricity use. Future work will leverage this model to quantify the reduction in annual electricity use across different climates, including the need for a standard vapor compression system to reheat the air during some of the year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Experimental Study of the Solubility of Rare Earth Chloride Salts (La, Nd, Er) in HCl Bearing Water Vapor from 350 – 425 °C

In this work, the solubilities of the rare earth chlorides REECl 3 , where REE = (La, Nd, Er), were measured in HCl bearing water vapor from 350 – 425°C with water partial pressures ranging from 8 – 170 bar. Solubility data were fit to the Pitzer-Pabalan quasi-chemical model in order to extract thermodynamic parameters for the formation of the gaseous REE-chloride-water clusters REECl 3 (H 2 O) n . The data show that the solubility of the REE chlorides are orders of magnitude higher than salts such as NaCl or CuCl at low water fugacities, despite their sublimation energies being substantially higher. This enhanced solubility is likely due to the high enthalpy associated with binding a single water molecule to form the species REECl 3 (H 2 O), with derived enthalpies ranging from –378 to –465 kJ/mol. Addition of further water molecules to form higher order clusters (n > 1) involves enthalpy changes of ~ -20 kJ/mol, and are in effect thermodynamically suppressed over the temperature range 350 – 425°C. Despite the enhanced solubility of small REECl 3 water clusters, simulations of boiling processes demonstrate that the REE show highly conservative behavior, partitioning strongly into the dense aqueous phase. Not surprisingly, the presence of phosphates in the system makes this effect even more pronounced, completely immobilizing the REE. This would reduce transport in both the vapor and aqueous phase to negligible levels. However, we suggest that vapor phase transport of the REE may play a significant role in systems having a relatively low partial pressure of water (below the saturation point), where the relatively high stability of the first hydrated REE chloride clusters (REECl 3 (H 2 O) and REECl 3 (H 2 O) 2 ) will give a preference for gas transport of the REE relative to other elements. This can likely happen in systems involving a gas/melt exchange in fumarolic exhalations, where water vapor discharges at relatively low (close to atmospheric) pressures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Theoretical model of dielectrophoretic water vapor condensation during multiphase flow of electrically charged water droplets in air

Water droplet growth in air, influenced by vapor diffusion and electrical charging, has significant implications for indoor air quality, cloud formation, and aerosol dynamics. Here, this study presents a comprehensive theoretical model that describes the growth dynamics of electrically charged water droplets under external electric fields, incorporating diffusion, electrostatic, and dielectrophoretic forces to enhance understanding and practical applications in air dehumidification and environmental control. A theoretical model was established to analyze the growth dynamics of the charged water droplets. The approach extended the thermodynamic framework of the Modified Kelvin-Thomson equation by integrating electrostatic and dielectrophoretic effects, enabling a comprehensive evaluation of vapor concentration near the surface of charged droplets. A sensitivity analysis was performed to assess the roles of droplet size, electric field intensity, surface charge, and vapor concentration on condensation rates. The study progressed beyond the classical diffusion-limited growth of neutral droplets, addressing the behavior of charged droplets in electrohydrodynamic environments. The model highlighted the significance of dielectrophoretic drift flux for dipolar vapor molecules, especially in micron-sized droplets ranging from 10 to 100 µm. Findings demonstrated that, for smaller droplets subjected to elevated electrical charge, average growth rates varied from 0.3 to 1.6 µm/s if the air relative humidity increased from 50 to 100 %. Analytical results are corroborated by numerical simulations, which exhibited strong concordance, thereby validating the proposed theoretical approach. This research introduced an innovative and scalable analytical methodology for electric field-enhanced droplet growth, offering valuable insights into the advancement of energy-efficient air dehumidification, water desalination, and atmospheric water harvesting technologies.

42 ENGINEERING↗