Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “vacuum electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Reduced-action-integral approach for photon-photon interactions in vacuum

Electromagnetic waves propagating through vacuum can polarize virtual electron–positron pairs; this polarization, in turn, nonlinearly modifies their propagation. A semi-classical nonlinear wave equation describing the propagation is derived from the Euler–Heisenberg Lagrangian density, which captures vacuum polarization effects up to the one-loop level. In this article, we present a reduced-actionintegral approach that enables rapid modeling of nonlinear phenomena arising from the Euler– Heisenberg Lagrangian. Application of the variational principle to the reduced action provides equations of motion for familiar light-pulse parameters, such as spot size, phase, polarization, and phase-front curvature, without requiring full-field simulations. Three examples demonstrate the utility of the approach: phase modulation, birefringence, and frequency mixing.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Single electrons on solid neon as a solid-state qubit platform

Progress towards the realization of quantum computers requires persistent advances in their constituent building blocks-qubits. Novel qubit platforms that simultaneously embody long coherence, fast operation and large scalability offer compelling advantages in the construction of quantum computers and many other quantum information systems 1-3 . Electrons, ubiquitous elementary particles of non-zero charge, spin and mass, have commonly been perceived as paradigmatic local quantum information carriers. Despite superior controllability and configurability, their practical performance as qubits through either motional or spin states depends critically on their material environment 3-5 . In this work, we report our experimental realization of a qubit platform based on isolated single electrons trapped on an ultraclean solid neon surface in vacuum 6-13 . By integrating an electron trap in a circuit quantum electrodynamics architecture 14-20 , we achieve strong coupling between the motional states of a single electron and a single microwave photon in an on-chip superconducting resonator. Qubit gate operations and dispersive readout are implemented to measure the energy relaxation time T 1 of 15 μs and phase coherence time T 2 over 200 ns. These results indicate that the electron-on-solid-neon qubit already performs near the state of the art for a charge qubit 21 .

36 MATERIALS SCIENCE↗

Synthesis and characterization of electron beam irradiation-induced damage in polycrystalline metal thin films

High-energy physics research, industrial sterilizing, and material processing depend extensively on electron beam accelerators. Exit windows are crucial components of such electron accelerator systems, maintaining vacuum integrity inside the machine while providing mechanical strength, thermal stability, and radiation resistance at the beam-target interface. In this study, thin metallic films of Ni, Ti, Cr, and V were explored for use in electron beam exit windows, and their properties were compared with the properties of their bulk counterparts. Simulation results of metal foils predicted Ti to exhibit less beam power dissipation compared to Ni. However, Ni possesses superior mechanical and structural properties compared to Ti. The performance of these films under electron beam irradiation was examined by depositing thin layers of these films on silicon and metallic substrates using magnetron sputtering and exposing them to e-beam irradiation in a controlled setup. The deposited films were subjected to a dose of approximately 66 kGy at a beam energy of 10 MeV and characterized prior to and postexposure to the beam using field emission scanning electron microscopy, atomic force microscopy, x-ray diffraction (XRD), and nanoindentation. Particular emphasis was given to characteristics like the grain structure, surface morphology, dislocation density, and hardness. XRD patterns revealed irradiation-induced changes in peak intensities, while the crystallinity remained largely unchanged. Nanoindentation results showed that the pristine and irradiated Ti and Ni films were twice as hard when compared to bulk Ti and Ni samples, regardless of the substrate type used (Si or bulk Ti, or Ni). These results emphasize the superior mechanical properties of thin metal films compared to their bulk counterparts. In conclusion, this study advances the optimization of thin film materials for robust and efficient e-beam applications, ensuring improved durability and operational reliability.

AFM↗

Towards the construction of the Mu2e electromagnetic calorimeter at Fermilab

Mu2e will search for the Charge Lepton Flavor Violating (CLFV) conversion of a muon into an electron in the field of a nucleus. A clean discovery signature is provided by the mono-energetic conversion electron (E e = 104.96 MeV). If no events are observed, Mu2e will set a limit on the ratio between the conversion and the nuclear capture rate below 3 × 10$^{-17}$ (at 90% C.L.). In order to confirm that the observed candidate is an electron, the calorimeter resolution requirements are to provide E res < 10%, T res < 500 ps for 100 MeV electrons while working in vacuum and in a high radiation environment and high magnetic field. The calorimeter is made of two annular aluminum disks, each one filled with 674 pure CsI crystals read out by SiPMs. A sophisticated mechanics and cooling system has been developed to support the crystals and cool the sensors. Radiation hard analog and fast digital electronics have been developed. In this paper the QC tests performed on the produced components and the construction status are reported, as well as the results obtained on the large size prototype with test beam data and at a cosmic ray test stand.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Full Technical Report: High-Rate Carbide Growth by Evaporation

Boron carbide (B 4 C) is an attractive inertial confined fusion (ICF) ablator and a unique ultra-hard material with numerous current and potential applications. What makes B 4 C attractive as an ablator is its relatively high density and the ability to form a stable glassy phase combined with excellent chemical and mechanical stability. Despite these advantages, the fabrication of B 4 C ablators has remained a challenge. Magnetron sputtering, our current frontrunner approach for B 4 C deposition, exhibits low deposition rates (< 2 μm/h) and undesirable nodular defects within the film structure that are believed to generate from the dusty plasma around the sputtering source. The goals of this project were to (1) establish alternative plasma-free, electron beam evaporation (EBE) capabilities for the deposition of thin films that are needed in mission-critical programs and; (2) demonstrate the feasibility to deposit B 4 C films at high rates by EBE in a bottom-up geometry and characterize their stoichiometry. In this feasibility study, we initially developed the capability to convert a general-use vacuum chamber into an electron beam evaporator as needed, or on demand. Then, we successfully used this setup to deposit films made of boron carbide and various other materials. By adjusting the deposition parameters and the evaporation source material, we were able to demonstrate the feasibility of reaching deposition rates as high as 8 μm/h, which is about 4 times the maximum rates obtained through sputtering methods. We predict that these values can still be further improved by implementing enhanced thermal control measures for the target source and optimizing electron beam parameters (ie. current, sweeping and frequency) since ceramic materials with similar densities to B 4 C can exhibit deposition rates of about twice this value. We anticipate that the skills and capabilities developed throughout this project will prove relevant not only to the HED and ICF campaigns but also to numerous existing and prospective applications focused on the development of ultra-hard carbide coatings. The fresh set of tools here developed will also facilitate the preparation and research on future new target materials of interest beyond B 4 C.

36 MATERIALS SCIENCE↗

Generation of Terawatt Attosecond Pulses from Relativistic Transition Radiation

When a femtosecond duration and hundreds of kiloampere peak current electron beam traverses the vacuum and high-density plasma interface, a new process, that we call here relativistic transition radiation (RTR), generates an intense ~ 100 as pulse containing ~ 1 terawatt power of coherent vacuum ultraviolet (VUV) radiation accompanied by several smaller femtosecond duration satellite pulses. This pulse inherits the radial polarization of the incident beam field and has a ring intensity distribution. This RTR is emitted when the beam density is comparable to the plasma density and the spot size much larger than the plasma skin depth. Physically, it arises from the return current or backward relativistic motion of electrons starting just inside the plasma that Doppler up shifts the emitted photons. The number of RTR pulses is determined by the number of groups of plasma electrons that originate at different depths within the first plasma wake period and emit coherently before phase mixing.

43 PARTICLE ACCELERATORS↗

Ultraviolet spectroscopy of pressurized and supercritical carbon dioxide

Abstract Carbon dioxide (CO 2 ) is prevalent in planetary atmospheres and sees use in a variety of industrial applications. Despite its ubiquitous nature, its photochemistry remains poorly understood. In this work we explore the density dependence of pressurized and supercritical CO 2 electronic absorption spectra by vacuum ultraviolet spectroscopy over the wavelength range 1455-2000 Å. We show that the lowest absorption band transition energy is unaffected by a density increase up to and beyond the thermodynamic critical point (137 bar, 308 K). However, the diffuse vibrational structure inherent to the spectrum gradually decreases in magnitude. This effect cannot be explained solely by collisional broadening and/or dimerization. We suggest that at high densities close proximity of neighboring CO 2 molecules with a variety of orientations perturbs the multiple monomer electronic state potential energy surfaces, facilitating coupling between binding and dissociative states. We estimate a critical radius of ~4.1 Å necessary to cause such perturbations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Photoelectron spectroscopy of CsK2Sb photocathode at Synchrotron Radiation Facility using vacuum transport system

As accelerators and electron microscopes become more advanced, high-performance photocathodes are required. In particular, Cesium potassium antimonide (CsK 2 Sb) photocathode is of interest because of its low emittance, excitability in visible light, and high quantum efficiency (QE). The challenge is its high susceptibility to environment that lead to low operating vacuum pressure and short lifetime/low extraction charge. To resolve these issues, it is necessary to understand the molecular structure of the cathode and its degradation mechanism. In this study, we transported CsK 2 Sb photocathode to a beamline of synchrotron radiation facility using a vacuum transport system for molecular structure analysis. Specifically, the cathode was deposited in an evaporation system at Nagoya University. We transported it to Aichi Synchrotron Radiation Center (Aichi SR) located 15 km away, and analyzed it in the depth direction by X-ray photoelectron spectroscopy (XPS) at BL7U. Based on the results, we quantitatively evaluated the composition ratios and stoichiometry of the cathode elements (Sb, K, Cs). A Cs ex-cess state of surface was observed at the surface, and it is consistent with previous studies. The intended atomic structure of CsK 2 Sb was formed only at a few nanometres of the surface on the Mo substrate. On the other hand, the CsK 2 Sb cathode structure on the graphene substrate was preserved further in the depth direction.

47 OTHER INSTRUMENTATION↗

Intense laser interaction with micro-bars

Intense laser fields interact very differently with micrometric rough surfaces than with flat objects. The interaction features high laser energy absorption and increased emission of MeV electrons, ions, and of hard x-rays. In this work, we irradiated isolated, translationally-symmetric objects in the form of micrometric Au bars. The interaction resulted in the emission of two forward-directed electron jets having a small opening angle, a narrow energy spread in the MeV range, and a positive angle to energy correlation. Our numerical simulations show that following ionization, those electrons that are pulled into vacuum near the object’s edge, remain in-phase with the laser pulse for long enough so that the Lorentz force they experience drive them around the object’s edge. After these electrons pass the object, they form attosecond duration bunches and interact with the laser field over large distances in vacuum in confined volumes that trap and accelerate them within a narrow range of momentum. The selectivity in energy of the interaction, its directionality, and the preservation of the attosecond duration of the electron bunches over large distances, offer new means for designing future laser-based light sources.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The fixed probe storage ring magnetometer for the Muon g-2 experiment at Fermi National Accelerator Laboratory

The goal of the FNAL E989 experiment is to measure the muon magnetic anomaly to unprecedented accuracy and precision at the Fermi National Accelerator Laboratory. To meet this goal, the time and space averaged magnetic environment in the muon storage volume must be known to better than 70 ppb. A new pulsed proton nuclear magnetic resonance (NMR) magnetometer was designed and built at the University of Washington, Seattle to track the temporal stability of the 1.45 T magnetic field in the muon storage ring at this precision. It consists of an array of 378 petroleum jelly based NMR probes that are embedded in the walls of muon storage ring vacuum chambers and custom electronics built with readily available modular radio frequency (RF) components. We give NMR probe construction details and describe the functions of the custom electronic subsystems. The excellent performance metrics of the magnetometer are discussed, where after 8 years of operation the median single shot resolution of the array of probes remains at 650 ppb.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessment of Blocking Contacts in Suppressing Polarization Effects in CsPbBr 3 Perovskite Detectors

The CsPbBr 3 perovskite has garnered significant attention as a room-temperature semiconductor for hard radiation detection due to straightforward synthesis, scalable crystal growth, low cost, and excellent energy resolution. However, despite these advantages, at ambient temperature, CsPbBr 3 devices may experience performance deterioration and irreversible failure due to “polarization” induced by electromigration of ions to electrical connections on the device. In this study, we tested several contact materials and their optimization deposition techniques to assess the stability of high-performance CsPbBr 3 γ-ray detectors. Metals, with low work functions (Ti, In, Sn, Sb, Pb, Bi, Al, Au, and TiC) and high-work-function (Au or Pt) contacts, were used to form different Schottky junctions using vacuum thermal evaporation, electron-beam evaporation, and sputtering methods. These detectors were tested in intermittent and continuous modes to assess their stability. Among the tested detectors, the Bi/CLB/Pt electrode configuration demonstrated superior stability, operating effectively for 11 months under periodic testing and 16 days under continuous testing. In contrast, other configurations functioned only for a few months under intermittent conditions. Upon incorporating a ~40-nm-thick TiC passivation layer on the anode side (Bi/TiC/CLB/Pt), the CLB device operated continuously for 36 days without degradation. In many cases, the failure mode of the devices was due to the degradation of the anode. Here, the chemical changes in the fresh and deteriorated anodes were characterized using scanning electron microscopy and energydispersive X-ray spectroscopy

CsPbBr3 perovskite↗

Flexible atomic layer deposition system for coating porous materials

In this paper, we describe an atomic layer deposition (ALD) system that is optimized for the growth of thin films on high-surface-area, porous materials. The system incorporates a moveable dual-zone furnace allowing for rapid transfer of a powder substrate between heating zones whose temperatures are optimized for precursor adsorption and oxidative removal of the precursor ligands. The reactor can both be evacuated, eliminating the need for a carrier gas during precursor exposure, and rotated, to enhance contact between a powder support and the gas phase, both of which help us to minimize mass transfer limitations in the pores during film growth. The capabilities of the ALD system were demonstrated by growing La 2 O 3 , Fe 2 O 3 , and LaFeO 3 films on a 120 m 2 g -1 MgAl 2 O 4 powder. Analysis of these films using scanning transmission electron microscopy and temperature-programmed desorption of 2-propanol confirmed the conformal nature of the oxide films.

36 MATERIALS SCIENCE↗

The effect of filament peaking on electron beam weld quality

Electron beam welding uses high intensity beams that are generated by an electron emitting cathode under high vacuum conditions. The cathode, typically a ribbon or wire filament of refractory metal, must be heated to sufficiently high temperatures for electron emission to occur and must be carefully controlled to produce the desired beam current while at the same time optimizing filament lifetime. Traditional methods for doing this in commonly used triode gun assemblies consist of first finding the filament knee point in the filament current versus beam current relationship that produces the desired beam current for a given beam voltage. The filament current is then increased by some amount, typically 5–10%, per conventional wisdom to produce a peaked beam. This investigation studies and quantifies the beam and weld quality produced by underkneed and overpeaked filaments using electron beam diagnostics to measure the power density distribution of these beams. Underkneed filaments are shown to have power densities that drop off very quickly below the traditional knee, resulting in poor weld penetration. Kneed filaments do not reach the full beam intensity and also produce shallow welds. Increasing the filament current 10% above the traditional knee was shown to produce a circular Gaussian-like beam with peaked intensity optimized for welding and for filament lifetime. Further increases in the filament current that produce overpeaked beams do not significantly change the beam or weld quality and would only contribute to a reduced filament lifetime.

Electron Beam Welding↗

Collisional Effects on Electron Trajectories in Crossed-Field Devices

Crossed-field diodes (CFDs) are used in multiple high-power applications and are characterized by an applied magnetic field orthogonal to the electric field, induced by the applied voltage across the anode-cathode gap. In vacuum, the Hull cutoff magnetic field (HCMF) represents the maximum applied magnetic field for which an electron from the cathode can reach the anode. This study investigates the effects of non-vacuum conditions on electron trajectories by introducing electron mobility, which represents particle collisions. We used numerical solutions of the electron force law and particle-in-cell simulations (XPDP1) to assess electron motion for various electron mobilities. For magnetic fields above the HCMF in vacuum, reducing the electron mobility increases the time for an electron emitted from the cathode to reach the anode. Reducing mobility below 22 C s/kg eliminates the HCMF for any magnetic field, meaning that an emitted electron will always cross the gap. We derived the magnetic field, mobility, and electron transit time corresponding to this condition by solving for the condition when the electron velocity in the direction across the anode-cathode gap going to zero at the anode. A parametric study of these conditions using theory and XPDP1 is performed under different gap distances, voltages, and magnetic fields.

42 ENGINEERING↗

Combining molecular beam epitaxy and low-energy electron microscopy with in situ magnetic susceptibility measurements within an integrated ultrahigh vacuum system

Quantum two-dimensional materials, including ultrathin superconducting films, are of great current research interest. These films are typically fabricated under ultra-high vacuum (UHV) conditions and are sensitive to the environment—prone to oxidation and contamination when exposed to the atmosphere. This hampers the study of their intrinsic properties by standard ex situ techniques. Here, we present a variable-temperature mutual inductance probe system integrated under UHV with molecular beam epitaxy (MBE) synthesis and low-energy electron microscopy, enabling nondestructive in situ characterization of superconducting thin films. The system employs a reflection-type configuration and reaches a low temperature (∼4 K) using a high-cooling-power, vibration-isolated cryocooler. In conclusion, we demonstrate the system performance by measuring the superconducting critical temperature in a copper-oxide thin film.

2D materials↗

EIC Hadron Beamline Vacuum Studies

Ninety percent of the EIC hadron ring vacuum chamber consists of cold-bore sections running through and interconnecting 4.55 K RHIC superconducting (SC) magnets. The EIC operating specification requires shorter bunches and 3x higher intensity beams which are not appropriate for the present RHIC stainless steel cold-bore beam tube. The intensity and emittance of the hadron beams will degrade due to interactions with residual gas or vacuum instabilities arising from the expected resistive-wall (RW) heating, electron clouds, and beam-induced desorption mechanisms. Without strategies to limit RW heating, major cryogenic system modifications are needed to prevent SC magnet quenches. The SC magnet cold-bore beam tubes will be equipped with a high RRR copper-clad stainless steel screen to significantly reduce RW heating and so the effect on the SC magnet cryogenic heat load and temperature. A thin amorphous carbon film applied to the beam-facing copper surface will suppress electron cloud formation. This paper discusses the vacuum requirements imposed by the EIC hadron beams and the plans to achieve the necessary vacuum and thermal stability that ensure acceptable beam quality and lifetime.

43 PARTICLE ACCELERATORS↗

All-vacuum-deposited inorganic cesium lead halide perovskite light-emitting diodes

Polycrystalline CsPbBr 3 thin films are deposited by vacuum co-evaporation of cesium halide and lead halide precursors, leading to uniform pinhole-free morphology and precise control over the film thickness and precursor stoichiometry. By utilizing the organic hole and electron transport layers, all-vacuum-deposited perovskite LEDs are fabricated. The resulting devices exhibit a maximum luminance of 1800 cd/m 2 , a 531 nm emission wavelength peak with a spectral linewidth of 21 nm, and an external quantum efficiency of 1.1%.

36 MATERIALS SCIENCE↗

Spectroscopic investigation of electron-beam-induced excitation and ionization of air [Abstract]

Time-dependent visible and near-ultraviolet emission spectroscopy was used to track the presence of excited and ionized states induced as an electron beam transited a cavity filled with air at low pressures. An electron beam was produced in vacuum using a Febetron pulsed-power generator modified to produce a peak voltage of 100 kV, a peak current of 4.5 kA, and a pulse width of 100 ns. The beam electrons then passed through thin anode and pressure foils and transited a cavity filled with dry air at either 0.1 Torr or 1 Torr, exciting and ionizing the air along the way. The spectral measurements were combined with information from electrical, interferometric, and imaging diagnostics to reveal different ionization dynamics for the two cases under study.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗