Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “utility rate analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Heterogeneity in own-price residential customer demand elasticities for electricity under time-of-use rates: Evidence from a randomized-control trial in the United States

Regulators, policymakers, and stakeholders in several states have raised concerns about the price elasticity of residential customers’ electricity demand, especially as related to different customer subpopulations, management of critical end-uses, and enrollment approaches. This analysis sought to quantify the diversity of residential customer price elasticity in a time-of-use rate across these different dimensions using data generated from a utility pricing experiment. Finally, customers were found to be more elastic during the peak period of critical peak days, who were predicted to own and use air conditioning, and who volunteered for time-of-use (TOU) rates (but those defaulted on were 25% as elastic).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nonlinear Photovoltaic Degradation Rates: Modeling and Comparison Against Conventional Methods

Although common practice for estimating photovoltaic (PV) degradation rate (RD) assumes a linear behavior, field data have shown that degradation rates are frequently nonlinear. This article presents a new methodology to detect and calculate nonlinear RD based on PV performance time-series from nine different systems over an eight-year period. Prior to performing the analysis and in order to adjust model parameters to reflect actual PV operation, synthetic datasets were utilized for calibration purposes. A change-point analysis is then applied to detect changes in the slopes of PV trends, which are extracted from constructed performance ratio (PR) time-series. Once the number and location of change points is found, the ordinary least squares method is applied to the different segments to compute the corresponding rates. The obtained results verified that the extracted trends from the PR time-series may not always be linear and therefore, “nonconventional” models need to be applied. All thin-film technologies demonstrated nonlinear behavior whereas nonlinearity detected in the crystalline silicon systems is thought to be due to a maintenance event. A comparative analysis between the new methodology and other conventional methods demonstrated levelized cost of energy differences of up to 6.14%, highlighting the importance of considering nonlinear degradation behavior

14 SOLAR ENERGY↗

Electricity Costs and Carbon Implications for CO 2 -to-Fuels in Selected Locations in 2030

With the growing interest in converting carbon dioxide (CO 2 ) to fuels and products to reduce overall greenhouse gas emissions and extend carbon from biogenic and other sources, the development of carbon capture and utilization (CO2U) technologies and industry is crucial. The Markets, Resources, and Environmental and Energy Justice of CO 2 -to-Fuels Technologies (short title: MarkeRs & EEJ) project supports this goal by assessing the resource and market potential and infrastructure requirements for mid-term (-2030) and long-term (-2050) deployment of CO2U technologies. The overall project analyzes CO2U economic and resource requirements as well as sustainability and environmental and energy justice (EEJ) metrics. This report focuses on short-term (-2030) aspects of the project. It identifies three CO2U locations in the Midwestern United States and quantifies the costs for potential electricity resources and marginal emissions for each site in the near term (e.g., 2030). We focus on four electricity purchase options, including retail rate, physical power purchase agreement (PPA), financial PPA, and real-time pricing (RTP), for each of the three sites and consider potential policies such as production tax credits (PTCs). We also assess time-dependent hourly marginal electricity costs and the marginal emission rates using modeled scenarios from Cambium (Gagnon et al. 2021).The results of the analysis are expected to inform other projects within the U.S. Department of Energy's CO 2 -to-Fuels Consortium, especially the Economics and Sustainability of CO 2 Utilization Technologies with Techno-Economic Analysis and Life Cycle Analysis (TEA/LCA) project, led by Michael Wang of Argonne National Laboratory and Ling Tao of the National Renewable Energy Laboratory. The project results are also expected to inform the investment and technology communities and policymakers at the U.S. Department of Energy, state, and regional levels and guide investment by government and industry in research and development portfolios.

09 BIOMASS FUELS↗

The Effect of Cell Geometry and Trigger Method on the Risks Associated with Thermal Runaway of Lithium-Ion Batteries

Consideration of thermal runaway heat output variability is paramount for the development of safe lithium-ion battery assemblies. This study utilizes data gathered from fractional thermal runaway calorimetry (FTRC) experiments to conduct a comparative analysis of thermal runaway heat output for three cell formats (18650, 21700, and 33600) as a function of trigger method (heaters, internal short-circuiting device, and nail penetration). The analysis is based on comparisons for the calculated total energy yield, fractional energy yield, heat rate, and heat flux. This study reveals that nail penetration tends to result in higher thermal runaway heat output for larger cells (21700 & 33600); these experiments also tended to result in higher fractions of the total energy being released through the cell body. The smaller cells (18650) did not appear to have significant variation in heat output as a function of trigger method. This finding suggests that, for this cell type, worst-case scenario heat output could be achievable in assembly level testing regardless of the utilized trigger method. This study also demonstrates successful translation of FTRC results, as recorded in the Battery Failure Databank, into meaningful analysis that breaks down the influence of specific conditions on thermal runaway heat output.

calorimetry↗

A comparison of building system parameters between affordable and market-rate housing in New York City

Low-income households in the United States experience higher than average energy burdens (defined as the proportion of household income spent on energy utilities), and many of these households struggle to simultaneously pay for rent, energy, and basic household necessities. The analysis presented here in this study examines whether the underlying characteristics of buildings and their energy systems could contribute to this disparity for affordable housing residents in New York City. It combines an energy audit dataset of 7,328 multifamily buildings with a database of properties receiving local, state, or federal housing subsidies. The results of this analysis indicate that the building-level installed equipment in large (greater than 50,000 square feet) affordable housing buildings in New York City is more efficient than that in market-rate buildings, but this trend largely disappears when considering overall building characteristics, such as location, size, or age. Significant differences in the types of systems installed in affordable and market-rate housing are also observed, as well as the types of energy efficiency recommendations made by energy auditors. However, these latter data were not normalized by building system characteristics, as that analysis is much more difficult to interpret for categorical data such as heating system type. These findings indicate that retrofit policies and building performance standards focused on affordable housing will likely need to account for underlying differences in building characteristics between affordable and market-rate housing to achieve intended impacts.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Growth mechanism of glucose-based hydrochar under the effects of acid and temperature regulation

Improving the tailorability of hydrochar synthesis is an effective way to enhance its performance and utilization efficiency. In this study, the growth rate, morphology, and molecular structure of hydrochar were controlled by regulating the pH and temperature of the hydrothermal carbonization process. Growth process analysis indicates that hydrochar has three growth periods: induction, rapid, and stable growth periods. It is mainly controlled by 5-hydroxymethylfurfural (HMF), which is formed by converting glucose and its transformation products. Further, the regulation of acid can significantly shorten the induction period of hydrochar, even under low-temperature conditions (<180 °C), and increase the growth rate of hydrochar. However, the degree of hydrochar adhesion varies: the lower the temperature, the greater the degree of its adhesion. Molecular structural analysis demonstrates that hydrochar mainly consists of furan structural domains and aromatic clusters, and its surface is rich in oxygen-containing functional groups. The degree at which hydrochar was aromatized was improved by increasing the reaction temperature (160–220 °C); whereas the regulation of acid reduced it and increased the content of oxygen-containing functional groups on the hydrochar surface. Based on these results, it is proposed that hydrochar formation has five stages and three growth periods with or without acid regulation.

59 BASIC BIOLOGICAL SCIENCES↗

Decay Dose Shielding Analysis with Hybrid Unstructured Mesh/Constructive Solid Geometry Monte Carlo Calculation and ADVANTG Acceleration

Here, the target segments of the Oak Ridge National Laboratory Second Target Station (STS) neutron production facility become highly activated due to spallation reactions or nuclei transmutation by primary protons and emitted neutrons. Once the target segments are removed from their location within the core vessel, decay dose rates must be accurately quantified to determine the shielding configurations of remote-handling tools and transport casks and to aid in planning maintenance activities. For this analysis, we utilized a hybrid unstructured mesh (UM)/constructive solid geometry approach for calculating spallation products and neutron fluxes, activation calculations using the AARE package that includes the CINDER2008 activation code to calculate the decay photon source at different cooling times, and the ADVANTG code to accelerate the final decay photon transport calculation. Both Type 316 stainless steel (SS-316) and lead were investigated as candidates for shielding materials. The decay photon transport calculation through the thick SS-316 or lead shields exhibited between 25 and 30 orders-of-magnitude attenuations in the radial direction, depending on the shield. Such a difficult shielding calculation required advanced variance reduction. ADVANTG has some missing features, which limits its usability in spallation neutron source applications. It does not support volumetric sources created for MCNP6.2 UM capability. An approximate source was created for this problem. Not only was this approximate source needed for running the ADVANTG calculation to generate the weight windows, but also it was essential to develop source biasing (SB) parameters that were crucial for dramatically accelerating the decay photon transport in this problem. With this approximate source, the analysis was completed in a very reasonable computational time, and the design of the STS remote-handling equipment was finalized. This paper compares the efficiency of Monte Carlo simulations with different weight window and SB parameters calculated using different approximate ADVANTG calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Commercial, industrial, and institutional discount rate estimation for efficiency standards analysis: Sector-level data 1998–2023

Underlying each of the U.S. Department of Energy’s (DOE’s) federal appliance and equipment energy conservation standards are a set of complex analyses of the projected costs and benefits of regulation. Any new or amended standard must be designed to achieve significant additional energy conservation, provided that it is technologically feasible and economically justified (42 U.S.C. 6295(o)(2)(A)). DOE determines economic justification based on whether the benefits exceed the burdens, considering a variety of factors, including the economic impact of the standard on consumers of the product and the savings in lifetime operating cost compared to any increase in price or maintenance expenses (42 U.S.C. 6295(o)(2)(B)). As part of this determination, DOE conducts a life-cycle cost (LCC) analysis, which models the combined impact of appliance first cost and operating cost changes on a representative commercial building sample to identify the fraction of customers achieving LCC savings or incurring net cost at the considered efficiency levels. Thus, the commercial discount rate value(s) used to calculate the present value of energy cost savings within the LCC model implicitly plays a role in estimating the economic impact of potential standard levels. This report provides an in-depth discussion of the commercial discount rate estimation process relying on the Capital Asset Pricing Model (CAPM) to estimate a business’ cost of equity, and by adding a risk adjustment factor to the risk-free rate associated with long-term U.S. Treasury bonds to estimate their cost of debt. It is an update to previous reports on estimating commercial discount rates from firm-level and sector-level financial data (e.g., Fujita, 2021, 2016). Major topics covered in this report include the following: • Discount rate estimation methods and rationale • Data sources used and data limitations • Discount rate distributions for use in standards analysis • Discount rate estimation methods and distributions specific to the small business subgroup analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Searching for the Highest- z Dual Active Galactic Nuclei in the Deepest Chandra Surveys

We present an analysis searching for dual active galactic nuclei (AGN) among 62 high-redshift (2.5 < z < 3.5) X-ray sources selected from the X-UDS, AEGIS-XD, CDF-S, and COSMOS-Legacy Chandra surveys. We aim to quantify the frequency of dual AGN in the high-redshift Universe, which holds implications for black hole merger timescales and low-frequency gravitational wave detection rates. We analyze each X-ray source using BAYMAX, an analysis tool that calculates the Bayes factor for whether a given archival Chandra AGN is more likely a single or dual point source. We find no strong evidence for dual AGN in any individual source in our sample. We increase our sensitivity to search for dual AGN across the sample by comparing our measured distribution of Bayes factors to that expected from a sample composed entirely of single point sources and find no evidence for dual AGN in the sample distribution. Although our analysis utilizes one of the largest Chandra catalogs of high-z X-ray point sources available to study, the findings remain limited by the modest number of sources observed at the highest spatial resolution with Chandra and the typical count rates of the detected sources. Our nondetection allows us to place an upper limit on the X-ray dual AGN fraction at 2.5 < z < 3.5 of 4.8% at the 95% confidence level. Expanding substantially on these results at X-ray wavelengths will require future surveys spanning larger sky areas and extending to fainter fluxes than has been possible with Chandra. We illustrate the potential of the AXIS mission concept in this regard.

79 ASTRONOMY AND ASTROPHYSICS↗

Mechanisms of metabolic adaptation in the duckweed Lemna gibba: an integrated metabolic, transcriptomic and flux analysis

Abstract Background Duckweeds are small, rapidly growing aquatic flowering plants. Due to their ability for biomass production at high rates they represent promising candidates for biofuel feedstocks. Duckweeds are also excellent model organisms because they can be maintained in well-defined liquid media, usually reproduce asexually, and because genomic resources are becoming increasingly available. To demonstrate the utility of duckweed for integrated metabolic studies, we examined the metabolic adaptation of growing Lemna gibba cultures to different nutritional conditions. Results To establish a framework for quantitative metabolic research in duckweeds we derived a central carbon metabolism network model of Lemna gibba based on its draft genome. Lemna gibba fronds were grown with nitrate or glutamine as nitrogen source. The two conditions were compared by quantification of growth kinetics, metabolite levels, transcript abundance, as well as by 13 C-metabolic flux analysis. While growing with glutamine, the fronds grew 1.4 times faster and accumulated more protein and less cell wall components compared to plants grown on nitrate. Characterization of photomixotrophic growth by 13 C-metabolic flux analysis showed that, under both metabolic growth conditions, the Calvin-Benson-Bassham cycle and the oxidative pentose-phosphate pathway are highly active, creating a futile cycle with net ATP consumption. Depending on the nitrogen source, substantial reorganization of fluxes around the tricarboxylic acid cycle took place, leading to differential formation of the biosynthetic precursors of the Asp and Gln families of proteinogenic amino acids. Despite the substantial reorganization of fluxes around the tricarboxylic acid cycle, flux changes could largely not be associated with changes in transcripts. Conclusions Through integrated analysis of growth rate, biomass composition, metabolite levels, and metabolic flux, we show that Lemna gibba is an excellent system for quantitative metabolic studies in plants. Our study showed that Lemna gibba adjusts to different nitrogen sources by reorganizing central metabolism. The observed disconnect between gene expression regulation and metabolism underscores the importance of metabolic flux analysis as a tool in such studies.

59 BASIC BIOLOGICAL SCIENCES↗

Phosphate‐functionalized Zirconium Metal–Organic Frameworks for Enhancing Lithium–Sulfur Battery Cycling

Abstract Lithium–sulfur batteries are promising candidates for next‐generation energy storage devices due to their outstanding theoretical energy density. However, they suffer from low sulfur utilization and poor cyclability, greatly limiting their practical implementation. Herein, we adopted a phosphate‐functionalized zirconium metal–organic framework (Zr‐MOF) as a sulfur host. With their porous structure, remarkable electrochemical stability, and synthetic versatility, Zr‐MOFs present great potential in preventing soluble polysulfides from leaching. Phosphate groups were introduced to the framework post‐synthetically since they have shown a strong affinity towards lithium polysulfides and an ability to facilitate Li ion transport. The successful incorporation of phosphate in MOF‐808 was demonstrated by a series of techniques including infrared spectroscopy, solid‐state nuclear magnetic resonance spectroscopy, and X‐ray pair distribution function analysis. When employed in batteries, phosphate‐functionalized Zr‐MOF (MOF‐808‐PO4) exhibits significantly enhanced sulfur utilization and ion diffusion compared to the parent framework, leading to higher capacity and rate capability. The improved capacity retention and inhibited self‐discharge rate also demonstrate effective polysulfide encapsulation utilizing MOF‐808‐PO4. Furthermore, we explored their potential towards high‐density batteries by examining the cycling performance at various sulfur loadings. Our approach to correlate structure with function using hybrid inorganic–organic materials offers new chemical design strategies for advancing battery materials.

Liu, Bingqian↗

Atomic Layer Deposition of Nickel Using Ni(dmamb)2 and ZnO Adhesion Layer Without Plasma

Abstract In this study, a novel deposition technique that utilizes diethylzinc (C 4 H 10 ZnO) with H 2 O to form a ZnO adhesion layer was proposed. This technique was followed by the deposition of vaporized nickel(II) 1-dimethylamino-2-methyl-2-butoxide (Ni(dmamb) 2 ) and H 2 gas to facilitate the deposit of uniform layers of nickel on the ZnO adhesion layer using atomic layer deposition. Deposition temperatures ranged from 220 to 300 °C. Thickness, composition, and crystallographic structure results were analyzed using spectroscopic ellipsometry, scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), and X-ray diffraction (XRD), respectively. An average growth rate of approximately 0.0105 angstroms per cycle at 260 °C was observed via ellipsometry. Uniform deposition of ZnO with less than 1% of Ni was displayed by utilizing the elemental analysis function via SEM, thereby providing high-quality images. XPS revealed ionizations consistent with nickel and ZnO through the kinetic and binding energies of each detected electron. XRD provided supplemental information regarding the validity of ZnO by exhibiting crystalline attributes, revealing the presence of its hexagonal wurtzite structure.

Baker, Kaiya↗

Bifacial Photovoltaic Module Degradation Dynamics

In a comprehensive study conducted at NREL's 75 kW bifacial single-axis-tracked field, accelerated degradation was observed in four out of five bifacial silicon photovoltaic (PV) module technologies when compared to their monofacial counterparts. Root cause analysis of accelerated bifacial degradation involved various analytical tools and techniques. This included employing RdTools to identify rates of power loss, conducting measurements on fielded and control modules using infrared imaging, electroluminescence (EL) and photoluminescence (PL), quantum efficiency (QE) analysis, IV-curves assessment, as well as utilizing handheld Raman and reflectance measurement targeted at anti-reflective coating. Most cases pointed to carrier lifetime degradation causing Voc loss and simultaneous Isc loss. In some cases, Isc further decreases likely due to optical effects from encapsulant degradation. The outcomes and methodologies employed in this investigation are documented in this publication. This study's significance is further emphasized by placing the findings within the broader context of the performance and degradation of various bifacial systems, as identified in the PV Fleets data.

bifacial↗

Insurance in the Operation of Photovoltaic Plants

This paper provides an overview of property and casualty insurance industry functions, insurance terminology descriptions, and special insurance coverage considerations for photovoltaic (PV) system owners, asset managers, operators, PV operation-and-maintenance service providers, utilities, and other parties. The paper includes the results of an analysis of 6 years of property and casualty insurance claims for PV equipment and discusses considerations for purchasing property and casualty insurance for owners and operators of PV systems. PV is a relatively new asset type, and insurance companies are revisiting rates and offerings as actuarial data become available. This paper seeks to inform decisions that optimize the balance of the cost of insurance with enabling benefits to finance, permitting, utility connections, and the operation of PV plants.

14 SOLAR ENERGY↗

Distributed Solar Utility Tariff and Revenue Impact Analysis: A Guidebook for International Practitioners

Depending on a range of technical, economic, policy, regulatory, and market-related factors, the adoption of DPV may have a net positive or negative financial impact on utilities and ratepayers. This guidebook provides a methodological approach for quantifying the net financial impact of DPV on utilities (in the form of “net revenue losses”) and ratepayers (in the form of “net tariff impacts”). Written for technical staff at utilities, regulatory bodies, energy ministries, research institutes, and civil society organizations who wish to better understand the financial impacts of DPV in their jurisdiction, this guidebook can be used to inform important decisions regarding DPV compensation, tariff design, and regulatory cost allocations, among other aspects. It is focused exclusively on customer-sited DPV systems and adopts a primarily cost-based (as opposed to an equally valid value-based) perspective to understanding DPV financial impacts. The approach for calculating net revenue losses can be applied in nearly any utility jurisdiction, regardless of institutional arrangements, business models, or regulatory paradigms.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An economic assessment of behind-the-meter photovoltaics paired with batteries on the Hawaiian Islands.

Due to natural variability and uncertainty, the ever-increasing penetration of solar generation in Hawaii presents challenges to power grid operators to maintain reliable system operation. Demand response (DR) has the potential to be a cost-effective tool for Hawaii to reach its aggressive renewable energy goals while maintaining the reliability of power grids. The Hawaii Public Utilities Commission has approved the Hawaiian Electric Company's revised portfolio of DR programs. The companies have released a grid services purchase agreement and subscribed an initial tranche of load into their DR programs. This paper presents innovative analytical methods and comprehensive economic assessment for distributed photovoltaics (PV) paired with battery energy storage systems (BESSs) for two new DR programs, including fast frequency response and capacity grid service. Optimal dispatch and sizing methods are proposed for the paired system considering different tariff schedules and PV compensation programs across five islands. It was found that while the best resource configuration and potential economic benefits vary with tariff structure, a BESS paired with PV can be optimally dispatched to generate multiple value streams simultaneously. Compensation from DR programs is an important value stream to help increase the cost-effectiveness of the integrated system.

Battery energy storage system↗

Sampling Rate Comparison for Distribution System Voltage Measurements

Measurement of the voltage delivered by an electric distribution is a relatively straight forward task. When determining the harmonic distortion in the voltage, matters associated with what orders of the 50/60 Hz harmonics to be analyzed dictate the sampling rate. A study addressing this matter is presented.

42 ENGINEERING↗

Safety-Related Instrumentation and Control Pilot Upgrade (Initial Scoping Phase Implementation Report)

This research report (1) describes the process followed and products developed during the SR I&C Pilot Project Initial Scoping Phase, and (2) captures lessons learned. Exelon Generation and LWRS collaborated to develop a Digital Transformation Strategy as part of a larger Advanced Concept of Operations. The proposed SR I&C Pilot Upgrade provides a foundation stone for this Digital Transformation that will improve plant safety, reliability, and operational performance while lowering plant Total Cost of Ownership (TCO). Initial Scoping Phase activities for this Pilot Project have been performed in accordance with industry processes that have been adapted to better support digital upgrades. These processes include IP-ENG-001, Standard Design Process (SDP), NISP-EN-04, Standard Digital Engineering Process (SDEP), and Electric Power Research Institute (EPRI) Report 3002011816, Digital Engineering Guide (DEG). Completing Initial Scoping Phase Engineering and Operations, Licensing, and Project Management Activities was necessary to sufficiently bound the scope, schedule, and estimated cost of the Project to enable utility management to authorize moving into the Conceptual Design Phase. A significant finding of the Business Case Analysis (BCA) methodology developed and applied as part of this effort was that the growth rate of material costs for sustaining the operation of obsolete SR I&C equipment is accelerating. This directly contributed to the Project Economic Analysis created to justify continuing the Project. Project Initial Scoping Phase lessons learned have also been captured to assist the larger industry in understanding the Digital Transformation Strategy and SR I&C Pilot Project Initial Scoping Phase efforts. This is in keeping with the public/private partnership that has been established between the Department of Energy (DOE) and Exelon for this effort with engagement from the NRC. By addressing first-of-a-kind (FOAK) risks and capturing lessons learned, the SR I&C Pilot Upgrade Project addresses technical, regulatory, and business risks to enable subsequent implementers of similar upgrade.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗