Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “utility impact evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Integration of equitable resilience metrics into climate-informed electric utility planning processes: phase one

Working together, Sandia National Laboratories, Southern California Edison (SCE) - an Investor-Owned Utility (IOU) - and the California Public Utilities Commission (CPUC) are studying how electric utilities can use equity and resilience metrics to help inform the prioritization and sequencing of resilience-driven infrastructure investments. To this end, this project evaluated “Social Burden,” an equitable resilience metric which measures the potential impact of disruptions in access to non-electric critical services on people and estimates community resilience to these disruptions. The Social Burden was expanded to incorporate SCE’s existing equity metric and applied to evaluate the potential impacts from a range of climate-informed hypothetical outage scenarios developed under SCE’s 2022 Climate Adaptation Vulnerability Assessment. One baseline (“blue-sky”) state and eight different outage scenarios were evaluated to measure the potential impacts of the outages on non-electric infrastructure, critical services, and people. Key findings include: 1) the Social Burden framework is flexible enough to adapt to and build upon existing utility equity and/or resilience metrics, 2) Social Burden results highlight the high degree of non-electric service redundancy within the SCE service area with most (6/8) hypothetical outage scenarios predicted to increase people’s Social Burden by less than 10%; however, 3) access to critical services and people’s ability to obtain them is unequal and spatially clustered, meaning that there are some hypothetical outage scenarios (2/8) that will exert a higher toll on communities directly experiencing the outage as well as some nearby communities with pre-existing vulnerabilities. The report concludes with recommendations for potential use cases of the expanded Social Burden metric and identifies priority follow-on work. Potential use cases may include incorporating equity into IOU’s prioritization of climate resilience investments. Additionally, Social Burden analysis may provide additional data and insights to augment grid planning, potentially by identifying additional needs and/or prioritizing previously identified needs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Markov chain Monte Carlo (MCMC) Bayesian inference approach to analyze apparent activation barriers and reaction orders from microreactor data

Statistical analysis of steady-state catalytic kinetic data is often limited by data sparsity due to the slow pace at which the data is collected. Data sparsity and limitations in statistical analysis make it difficult to differentiate between mechanistic models and catalytic sites. A Bayesian inference tool is reported for catalysis researchers to estimate error in the determination of reaction orders from steady state microreactor data. The benefits of a Bayesian inference approach are discussed, as an alternative to the more common frequentist approach. The approach incorporates prior knowledge of the system and the data collected to form an error estimate on reaction orders. We investigated the effects of three distinct data treatments—individual fitting of trials, pooled analysis, and constrained regression methods—on the precision and uncertainty of reaction order determinations. To assess the robustness of our findings, we conducted sensitivity analyses to evaluate the influence of Bayesian parameters on uncertainty estimation. Additionally, we utilized synthetic data to illustrate how data quality impacts the precision of uncertainty assessments. We show Bayesian analysis can obtain a more precise estimation of error with a sparse data set than a frequentist analysis. Finally, this work provides strong evidence that the adoption of Bayesian analysis of kinetic data may help researchers make more precise arguments as to the strength of their evidence for a particular mechanistic hypothesis, or in comparing across different catalysts.

42 ENGINEERING↗

Agent-Based Simulation of Price-Demand Dynamics in Multi-Service Charging Station

As the adoption of electric vehicles and hydrogen fuel-cell vehicles grows, understanding how dynamic pricing strategies influence charging and refueling behaviors becomes crucial for optimizing local energy markets. This paper proposes a simulation-based analysis of a hydrogen-electricity integrated charging station that serves both types of vehicles. A multi-agent simulation framework is developed to model the interactions between vehicles and the station, incorporating price- and delay-sensitive behaviors in decision-making. The station can dynamically adjust energy prices, while vehicles optimize their charging or refueling choices based on their utility values. A series of sensitivity analyses are conducted to evaluate how electricity pricing, infrastructure capacity, and waiting behavior impact station performance. Results highlight that moderate electricity prices maximize user participation without sacrificing profit, infrastructure should be right-sized to demand to avoid over- or underutilization, and delay-toleration also affects service outcomes, which may reach the maximum service coverage at the threshold of 45 minutes.

Wang, Xudong [University of Tennessee, Knoxville (↗

Rapid Evaluation and Response to Impacts on Critical End-Use Loads Following Natural Hazard-Driven Power Outages: A Modular and Responsive Geospatial Technology

The disparate nature of data for electric power utilities complicates the emergency recovery and response process. The reduced efficiency of response to natural hazards and disasters can extend the time that electrical service is not available for critical end-use loads, and in extreme events, leave the public without power for extended periods. This article presents a methodology for the development of a semantic data model for power systems and the integration of electrical grid topology, population, and electric distribution line reliability indices into a unified, cloud-based, serverless framework that supports power system operations in response to extreme events. An iterative and pragmatic approach to working with large and disparate datasets of different formats and types resulted in improved application runtime and efficiency, which is important to consider in real time decision-making processes during hurricanes and similar catastrophic events. This technology was developed initially for Puerto Rico, following extreme hurricane and earthquake events in 2017 and 2020, but is applicable to utilities around the world. Given the highly abstract and modular design approach, this technology is equally applicable to any geographic region and similar natural hazard events. In addition to a review of the requirements, development, and deployment of this framework, technical aspects related to application performance and response time are highlighted.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact Mapping for Geospatial Reasoning and Decision Making

Objective The reported study evaluated a novel approach to aiding geospatial reasoning and decision making. Background Impact mapping aims to alleviate the cognitive demands of geospatial tasks in part by externalizing data in the form of an integrated decision surface. This is achieved by aggregating data across multiple sources of information and visualizing their combined utility rather than objective measurements or individual utility. Previous research has shown that geospatial decisions improve when aided in this manner, but it remains unknown if dynamic decision making, often plagued by fatigue and anchoring bias, would benefit similarly. Method The experiment implemented a systematic manipulation of the presence of a composite impact map and the number of attributes present in a two-stage disaster relief, resource allocation task to investigate when and how impact mapping is beneficial or deleterious to decision makers. Results The presence of the composite impact map increased the utility of selected sites, increased re-planning decisions, reduced information display views, and reduced workload. Generally, the effect of the composite impact map was greater when participants were asked to evaluate more attributes. Conclusion Composite impact maps appear to improve repeated geospatial reasoning and minimize anchoring bias because they alleviate the cognitive demands otherwise necessary to interpret and maintain information from multiple attributes. Application Data visualization techniques, such as impact mapping, can improve repeated geospatial decision making in environments that include high cognitive demand.

Illingworth, David A.↗

Data-Driven Energy Resilience Assessment and Enhancement in Urban Communities: A Case Study in Detroit

This paper presents a data-driven framework for assessing and enhancing energy resilience in urban communities. The resilience assessment is based on two datasets: 1) annual aggregated power outage data and 2) 15-minute interval outage data. High-impact, low-probability (HILP) events are identified within these datasets to evaluate community resilience under extreme conditions. To enhance resilience, an optimization framework utilizing mixed integer linear programming is developed to determine the optimal sizing and placement of solar photovoltaic (PV) systems and battery energy storage systems (BESS). This method offers a cost-effective and practical solution for improving energy resilience in vulnerable communities. Furthermore, a case study of the City of Detroit in Michigan demonstrates the effectiveness of the framework through simulation and validation.

Energy resilience assessment↗

Mechanical and Electrochemical Implications of Drying Temperature on Lithium‐Ion Battery Electrodes

Abstract Lithium‐ion battery (LIB) electrodes are typically produced with n‐methyl‐2‐pyrrolidone, a toxic solvent that is a known carcinogen and reproductive hazard. Accordingly, aqueous processing has been an expanding area of research interest in the field of LIB manufacturing. Although aqueous processing has been widely successful in anode processing, serious challenges remain in processing the cathode. In this work, the drying mechanics of cathode processed with both solvents is investigated though implementation of a chemical‐engineering‐based model to better understand the utilization of heat provided by experimentally determining the heat and mass transfer coefficients. Electrochemical performance is also evaluated to determine the impact of drying temperature on cycling performance. Binder distribution is determined via various methods to confirm differences in binder homogeneity as a function of both solvent and drying temperature. Identified is the large difference in the efficiency in which the heat is used as well as an ideal drying temperature for both aqueous and non‐aqueous processed cathodes. Also identified is the increased sensitivity to processing temperature for aqueous processed electrodes compared to non‐aqueous processed counterparts, pointing to the possibility of tuned drying regimes which would capitalize on the potential cost savings of aqueous processing for cathodes.

25 ENERGY STORAGE↗

Statistical Design of Experiments Enables Rapid Exploration of Perfluorobutane Sulfonate Degradation

The phase-out of long-chain PFAS has led to the proliferation of highly recalcitrant short-chain analogs, and mineralization technologies for these short-chain PFAS are needed to mitigate their deleterious effects on environmental and human health. In this study, we utilize a statistical design of experiments, specifically, response surface methodology, to rapidly evaluate the electrochemical degradation of the short-chain PFAS, perfluorobutane sulfonate (PFBS). We evaluate the impacts of the three primary electrochemical parameters (concentration of PFBS, concentration of supporting electrolyte, and applied current) over multiple orders of magnitude on the three primary reaction outcomes of electrochemical PFBS degradation (incomplete PFBS decomposition, complete PFBS mineralization as fluorine, and anodic energy consumption). Our results correspond with literature and clearly identify the well-known tradeoff between energy consumption and complete mineralization. Intriguingly, partial PFBS decomposition and energy consumption demonstrate nonlinear dependencies in the current/supporting electrolyte concentration space and the current/PFBS concentration space, respectively. These findings highlight the utility of the response surface methodology model to efficiently interrogate a large parameter space, identifying both common results and less-obvious interactions between electrochemical parameters and their influences on reaction outcomes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigating Benefits and Challenges of Converting Retiring Coal Plants into Nuclear Plants

A coal-to-nuclear (C2N) transition means siting a nuclear reactor at the site of a recently retired coal power plant. Three overarching questions from the C2N transition guide this research: where in the United States are retired coal facilities located and what factors make a site feasible for transition; what factors of technology, cost, and project timeline drive investor economics over such a decision; and how will C2N impact local communities? The study team evaluated the siting characteristics of recently retired plants and those operating coal-fired power plant sites run by a utility or an independent power producer utilizing publicly available data to screen U.S. coal power plant sites to nuclear-feasible locations. After screening all retired coal sites to a set of 157 potential candidates and screening operating sites to a set of 237 candidates, the study team estimates that 80% of retired and operating coal power plant sites that were evaluated have the basic characteristics needed to be considered amenable to host an advanced nuclear reactor. For the recently retired plant sites evaluated, this represents a capacity potential of 64.8 GWe to be backfit at 125 sites. For the operating plant sites evaluated, this represents a capacity potential of 198.5 GWe to be backfit at 190 sites. This report evaluates a case study for the detailed impacts and potential outcomes from a C2N transition. Based on the nuclear technology choices and sizes evaluated to replace a large coal plant of 1,200 MWe generation capacity at the case study site, nuclear overnight costs of capital could decrease by 15% to 35% when compared to a greenfield construction project, through the reuse of infrastructure from the coal facility. Nuclear replacement designs can have a lower capacity size because nuclear power plants run at higher capacity factors than coal power plants. In the case study replacing coal capacity with 924 GWe of nuclear capacity, the study team found regional economic activity could increase by as much as $\$275 million$ and add 650 new, permanent jobs to the region of analysis. The evaluated site choice in the report is hypothetical for analysis purposes only and based on available data and documented assumptions. Consequently, the findings only inform at a general level. A community, investor, or other interested stakeholder can use these results to set up a detailed, in-depth analysis for a specific application of interest, such as evaluating a C2N transition of a specific coal power plant and a specific nuclear technology design. The report was subjected to independent peer reviews by experts in systems engineering and regional economic modeling to evaluate analysis and assumptions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Do Mandates Deliver Cost Reductions for Energy Storage?

In 2013, California implemented a mandate directing the state’s investor-owned utilities to procure 1325 MW of energy storage, to help integrate nondispatchable renewable sources of energy and assist the state in meeting its environmental goals. This paper evaluates this policy’s impact of both battery deployment, and cost, finding that as of 2019, the state was effective in spurring nearly 500 MWh of battery storage deployment over what would have been installed in absence of the policy. This additive deployment would have the effect of reducing global battery cell costs by roughly $1.00/ kWh, based on learning by doing. To support these findings, we utilize both a difference in differences estimation, and a synthetic control analysis, both of which allow us to compare battery deployment in California, to deployment in other states. To pair deployment to cost reduction, we use a learning curve analysis, which links battery shipments to cell and storage block costs. For policymakers, these results provide evidence to the effectiveness of mandates in promoting storage deployment and help explain how these policies can induce downstream effects.

Boff, Daniel S.↗

Measuring the Stress Factors for Photovoltaic (PV) Backsheet Degradation

Back sheet failure has resulted in power loss and large-scale recall of photovoltaic modules, resulting in billions of dollars in lost revenue. The light exposure on the backside of a photovoltaic module comes primarily from reflected light which alters the distribution of natural sunlight. Because of this, modelling the backside exposure and duplicating the exposure is much more difficult than modeling the frontside exposure. This project aims to study how various back sheets and junction box materials degrade under different conditions and to develop Python code to help model and predict degradation. The stress factors for back-sheet degradation must be quantified to extrapolate accelerated stress tests to the field. Test samples were placed in the A3, A4, and A5 conditions, as defined in IEC 62788-7-2, to assess the temperature and humidity dependence of ultraviolet (UV) induced degradation. We are utilizing a custom chamber with exposure from 0.5 UV-suns to 5 UV-suns to understand the dependence of degradation on light intensity. A group of samples put in the A3 condition had glass filters with 50% UV cut-offs of 320 nm, 335 nm, and 360 nm to assess the wavelength dependence of UV degradation. All this data is necessary to assess the impact of non-standard UV light exposure. The material evaluation tests include gloss measurements, attenuated total internal reflectance Fourier transform infrared spectroscopy (ATR-FTIR), UV-visible reflectance/transmittance utilizing a Cary Ci7000 spectrophotometer, and a nano-indenter for surface hardness and modulus measurements. Alongside the experimental work, there is a computational effort using raytracing and Python open-source tools in PVDeg , PVLib, and Bifacial_Radiance. This code will create specific exposure scenarios and enable the evaluation of chamber degradation relative to field degradation. Equation 1 is a strawman equation used to model degradation on the backside of a PV module. We will create simplified code, based on the results of ray-tracing calculations, which uses a view factor approach to provide fast calculations for the most common exposure scenarios.

14 SOLAR ENERGY↗

Surrogate-assisted optimization under uncertainty for design for remanufacturing considering material price volatility

Remanufacturing is a well-established end-of-life (EOL) strategy that promises significant savings in energy and carbon emissions. However, the current design practices are not remanufacturing-inclusive, i.e., the majority of products are designed for a single life cycle. As a result, potential products that can sustain multiple life cycles are deprived of additional benefits of being designed for remanufacturing, such as reduced material usage, lower cost, and improved environmental impact. Moreover, the uncertainty in design, material selection, and economics are not considered to produce remanufacturable designs. Accordingly, this research proposes a design for remanufacturing (DfRem) framework that accounts for design uncertainty and material price volatility. The framework systematically explores the design space, performs design optimization under uncertainty, followed by topology optimization to provide additional mass savings, and finally, a price volatility analysis for plausible design material choices. The candidate designs are evaluated based on their design mass, material price volatility, failure mode characteristics, carbon footprint, and embodied energy impacts. The proposed framework's utility is demonstrated via the use of an engine cylinder head case study subjected to thermo-mechanical loads along with fatigue and wear failure. Considering grey cast iron and aluminum alloy as the design material choices, it was found that the cast iron design reduced the initial design mass by 6% as opposed to a 5% decrease for aluminum. On the other hand, about 8% area of the cast iron design failed due to fatigue, compared to 3% for aluminum. Here, we further observed that although the aluminum design provided better mechanical performance than the cast iron design, this material was more expensive and volatile in price.

36 MATERIALS SCIENCE↗

Automating the Solar Interconnection Technical Evaluation Process: PREconfiguring and Controlling Inverter SEt-Points (PRECISE)

Utilities are receiving an increasing number of interconnection requests for distributed solar photovoltaic (PV) systems from their customers, requiring a solution to quickly and intelligently perform technical assessments of these requests and to manage these new renewable energy assets. In this paper, we present a stand-alone interconnection tool, PREconfiguring and Controlling Inverter SEt-points (PRECISETM), and how it overcomes the challenges of accelerating technical evaluations and leverages smart inverter functionality to provide local voltage support on an as-needed basis. The paper details the purpose and architecture of PRECISE, including tools, data source requirements, the model-based interconnection evaluation process, and technical results. PRECISE is an integrated software tool that customizes PV inverter settings for utilities by modeling and assessing impacts on local voltages and the need for advanced inverter functions (AIFs) (e.g., volt-VAR and volt-watt). PRECISE maximizes the use of readily available utility data sets to make fast online assessments of incoming PV interconnection requests and makes accept/reject recommendations along with custom settings for AIFs.

ENERGY PLANNING, POLICY, AND ECONOMY,SOLAR ENERGY↗

Response to Bovine Viral Diarrhea Virus in Heifers Vaccinated with a Combination of Multivalent Modified Live and Inactivated Viral Vaccines

Bovine viral vaccines contain both live or inactivated/killed formulations, but few studies have evaluated the impact of vaccinating with either live or killed antigens and re-vaccinating with the reciprocal. Commercial dairy heifers were utilized for the study and randomly assigned to three treatment groups. Treatment groups received a commercially available modified-live viral (MLV) vaccine containing BVDV and were revaccinated with a commercially available killed viral (KV) vaccine containing BVDV, another group received the same KV vaccine and was revaccinated with the same MLV vaccine, and yet another group served as negative controls and did not receive any viral vaccines. Heifers in KV/MLV had higher virus neutralizing titers (VNT) at the end of the vaccination period than heifers in MLV/KV and control groups. The frequency of IFN-γ mRNA positive CD4+, CD8+, and CD335+ populations, as well as increased mean fluorescent intensity of CD25+ cells was increased for the MLV/KV heifers as compared to KV/MLV and controls. The data from this study would suggest that differences in initial antigen presentation such as live versus killed could augment CMI and humoral responses and could be useful in determining vaccination programs for optimizing protective responses, which is critical for promoting lifetime immunity.

60 APPLIED LIFE SCIENCES↗

Long-Term Assessment of Commercial Building Energy and Carbon Emissions in the Northwestern Region Under Future Weather Trend

The future climate significantly impacts building performance and increases uncertainties in energy simulations. A rising temperature trend is expected to heighten cooling loads during summer and result in more carbon emissions. Understanding the impact of future climate on building performance is significant for policymakers to make informed decisions. Building retrofit measures can improve building energy efficiency and reduce operational carbon emissions, yet their effects under future climate conditions have not been fully investigated so far. Thus, we proposed an assessment methodology for evaluating long-term energy consumption and operational carbon reduction potential using a building stock dataset. For this study, commercial buildings in the northwestern (NW) region were utilized to assess the impacts of future climate and building retrofit. In addition, we selected Montana with a cold and dry climate as an example to analyze and discuss the carbon emission reduction potential in buildings. The main findings are: (1) Under future climate trends, changes in energy use intensity (EUI) will fluctuate due to variations in heating and cooling degree-days (HDDs and CDDs) and increasing HDDs will lead to increasing EUI. (2) After applying annual building retrofitting, the long-term EUI reduction potential of buildings in the NW region will decrease with the increasing retrofitting degree, and the short-term EUI reduction potential will be impacted by the change of heating and cooling degree days. (3) In Montana, the long-term carbon intensity reduction potential of retrofitted buildings will decrease under future climate trends with the increasing renewable energy penetration.

building energy modeling↗

Salt Hydrate Eutectic Thermal Energy Storage for Building Thermal Regulation (Final Technical Report)

Thermal energy storage is anticipated to play an important role in developing the power grid of the future - a power grid that meets increasing demands of users, is resistant to disruptions, but also allows for greater penetration of renewable resources. Specifically, thermal energy storage materials can be integrated into HVAC systems and building envelopes, where they can be used to shift power demands for building climate control from periods of peak demand to periods of low demand. Phase change materials (PCMs) are compelling as low-cost, high energy density thermal energy storage materials for building thermal management. However, there is a lack of high performance low-cost PCMs within the specific temperature ranges which would most effectively allow for power load shifting. Inorganic salt hydrates represent a promising class of PCMs, but their inherent limitations cause them to be currently unavailable for reliable building applications. The overarching goals of this research effort are to: 1) Discover low-cost, high volumetric density salt hydrate eutectic PCMs to store low-quality heat (10 to 40 °C); 2) Introduce a high thermal conductivity matrix to reduce the time constant for energy storage to ~0.1 to 1 hr, incorporate nucleation catalysts to decrease undercooling, and utilize microencapsulation and shape stabilization approaches, minimizing moisture loss/gain, mitigating phase separation, and maintaining stable melting behavior over the lifetime of the compounds; 3) Evaluate the impact these systems have on peak load shifting, and the potential for overall energy savings under different climatic scenarios and building configurations. These goals will be achieved by an integrated research program consisting of six cohesive research subtasks: 1) Materials discovery of eutectic salt hydrate PCMs by using computationally predicted thermodynamic equilibria, coupled with high-throughput experimental validation, 2) Rapid experimental screening of nucleation catalysts identified through robust computational databases, 3) Embedding salt hydrate PCM into a low cost and scalable high conductivity matrix, 4) Microencapsulation of salt hydrate microspheres using hybrid inorganic-polymer microencapsulation approach, 5) Shape stabilization by thermoreversible salt hydrate salogels, and 6) Analysis of end-use using thermal simulations, and characterization of mock-up energy storage finished components.

25 ENERGY STORAGE↗

State Technical Assistance - New Mexico Energy and Conservation Management Division Report [Slides]

The New Mexico Energy and Conservation Management Division (ECMD) sought technical assistance to enhance their ability to evaluate program impacts using the Low-Income Energy Affordability Data (LEAD) tool. NLR assisted ECMD in leveraging the LEAD tool to calculate and analyze energy burden across electric utility service areas, enabling them to assess program outcomes more effectively. To meet ECMD's goals, NLR developed a customized methodology to calculate utility-specific energy burden metrics using census tract data and available utility service area information from the Energy Information Administration (EIA). While acknowledging some limitations in the EIA dataset, NLR estimated the percentage of households within each service territory and incorporated relevant filters such as income, housing characteristics, and other demographics from the LEAD tool. The analysis provided ECMD with a new capability to evaluate program success based on energy savings, reductions in energy burden, and other performance indicators. The data and methodology also support discussions with utilities to improve the accuracy of service territory datasets. ECMD can use the outputs to track program effectiveness and plan future initiatives. NLR offered the possibility of follow-on work, including capacity-building for ECMD to repeat the analysis independently and the option to refine the analysis with updated service.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Model Quality and Measurement Density Impact on Volt/Volt Ampere Reactive Optimization Performance

The operation of the utility grid is being reshaped by the continuous addition of distributed energy resources and advanced metering infrastructure, which challenge existing grid control strategies. Some utilities deploy advanced distribution management systems (ADMS) to assist with the consolidation of various applications and to augment situational awareness in response to the new power delivery dynamics. An ADMS is an integrated software platform that provides utilities with a way to enhance their reliability, control, and optimization with advanced applications, such as volt/VAR optimization (VVO). A VVO application could serve as a vehicle to deliver cost savings by providing the utility with a method to reduce rates by controlling the voltage and decreasing the energy usage in their service territory. Some utilities are reluctant to integrate an ADMS, because it is a significant investment that requires approval from the public regulatory commission and/or their customers. This paper evaluates the impact on VVO performance when using a lower-quality network model supplemented with additional measurements, which could provide an implementation for cost savings. The results show that a better model quality would provide the highest energy savings; however, some level of telemetry is necessary in all scenarios to prevent voltage exceedances.

24 POWER TRANSMISSION AND DISTRIBUTION↗