Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ultrahigh vacuum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Ultrahigh vacuum, high temperature, low cycle fatigue of coated and uncoated Rene 80

A study was conducted on the ultrahigh vacuum strain controlled by low cycle fatigue behavior of uncoated and CODEP B-1 aluminide coated Rene' 80 nickel-base superalloy at 1000 C (1832 F) and 871 C (1600 F). The results indicated little effect of coating or temperature on the fatigue properties. There was, however, a significant effect on fatigue life when creep was introduced into the strain cycles. The effect of this creep component was analyzed in terms of the method of strainrange partitioning.

Kortovich, C. S.↗

Tribological reactions of perfluoroalkyl polyether oils with stainless steel under ultrahigh vacuum conditions at room temperature

The reaction between three types of commercial perfluoroalkyl polyether (PFPE) oils and stainless steel 440C was investigated experimentally during sliding under ultrahigh vacuum conditions at room temperature. It is found that the tribological reaction of PFPE is mainly affected by the activity of the mechanically formed fresh surfaces of metals rather than the heat generated at the sliding contacts. The fluorides formed on the wear track act as a boundary layer, reducing the friction coefficient.

Mori, Shigeyuki↗

Thermal fatigue behavior of T-111 and ASTAR 811C in ultrahigh vacuum

The thermal fatigue behavior of the tantalum alloys T-111 (Ta-8W-2Hf) and ASTAR 811C (Ta-8W-1Re-0.7Hf-0.025C) has been evaluated using completely reversed push-pull fatigue tests conducted in ultrahigh vacuum with independently programmed temperature and strain cycles. Test results showed that cycling of the test temperature simultaneously with the mechanical strain in most cases significantly reduced the cycles to failure of both alloys compared to isothermal testing. Notched specimens had reduced lives under isothermal conditions, but the presence of a notch or use of a 1-h holdtime provided only a small further decrease in life for the temperature cycled tests. Compressive stress at the maximum temperature produced longer lives than tensile stress. ASTAR 811C was more fatigue resistant than T-111 isothermally and did not have as great a decrease in life with thermal cycling. Results are analyzed by partition of plastic strains into creep and creep-independent components and considering where each component was active in the hysteresis cycle.

Sheffler, K. D.↗

An ultrahigh vacuum multipurpose specimen chamber with sample introduction system for in situ transmission electron microscopy investigations

A commercial transmission electron microscope (TEM), with flat-plate upper pole piece configuration of the objective lens, and top-entry specimen introduction was modified by introducing an ultrahigh vacuum (UHV) specimen chamber for in situ TEM experimentation. The pumping and design principles and special features of this UHV chamber, which makes it possible to obtain 5 x 10 to the -10th mbar pressure at the site of the specimen, while maintaining the airlock system that allows operation in the 10 to the -10th mbar range within 15 min after specimen change, are described. Design operating pressures and image quality (resolution of metal particles smaller than 1 nm in size) were achieved. Schematic drawings and design dimensions are included.

Heinemann, K.↗

Polarized tip-enhanced Raman spectroscopy at liquid He temperature in ultrahigh vacuum using an off-axis parabolic mirror

Tip-enhanced Raman spectroscopy (TERS) combines inelastic light scattering well below the diffraction limit down to the nanometer range and scanning probe microscopy and, possibly, spectroscopy. In this way, topographic and spectroscopic as well as single- and two-particle information may simultaneously be collected. While single molecules can now be studied successfully, bulk solids are still not meaningfully accessible. It is the purpose of the work presented here to outline approaches toward this objective. We describe a home-built, liquid helium cooled, ultrahigh vacuum TERS. The setup is based on a scanning tunneling microscope and, as an innovation, an off-axis parabolic mirror having a high numerical aperture of ~0.85 and a large working distance. The system is equipped with a fast load-lock chamber, a chamber for the in situ preparation of tips, substrates, and samples, and a TERS chamber. Base pressure and temperature in the TERS chamber were ~3 × 10 –11 mbar and 15 K, respectively. Polarization dependent tip-enhanced Raman spectra of the vibration modes of carbon nanotubes were successfully acquired at cryogenic temperature. The new features described here including very low pressure and temperature and the external access to the light polarizations, thus the selection rules, may pave the way toward the investigation of bulk and surface materials.

47 OTHER INSTRUMENTATION↗

Precision gage measures ultrahigh vacuum levels

Ionization gage in which internally generated X rays are minimized is described. This gage permits the measurement of gas pressures in ultrahigh systems of micro-pico torr /10-18/.

Hudson, J. B.↗

Combining molecular beam epitaxy and low-energy electron microscopy with in situ magnetic susceptibility measurements within an integrated ultrahigh vacuum system

Quantum two-dimensional materials, including ultrathin superconducting films, are of great current research interest. These films are typically fabricated under ultra-high vacuum (UHV) conditions and are sensitive to the environment—prone to oxidation and contamination when exposed to the atmosphere. This hampers the study of their intrinsic properties by standard ex situ techniques. Here, we present a variable-temperature mutual inductance probe system integrated under UHV with molecular beam epitaxy (MBE) synthesis and low-energy electron microscopy, enabling nondestructive in situ characterization of superconducting thin films. The system employs a reflection-type configuration and reaches a low temperature (∼4 K) using a high-cooling-power, vibration-isolated cryocooler. In conclusion, we demonstrate the system performance by measuring the superconducting critical temperature in a copper-oxide thin film.

2D materials↗

An improved Orbitron ionization gage measures ultrahigh vacuum

Ionization gage with improved signal-to-noise ratio has a helical coil electrode which separates the solid cathode ion collector from the volume where ionization of gas molecules takes place. Helical coil increases lifetime of electrons and reduces secondary emission from the collector.

Gosselin, C. M.↗

Quadrupole ionization gage measures ultrahigh vacuum

Quadrupole system, energized with a 200 MHz electric field, restrains ionizing electrons within the center of the ionization gage. Oscillatory trajectory of the electrons increases the probability of ionizing the gas molecules, lowers background X-ray level, and increases the signal-to-noise ratio.

Schwarz, H. J.↗

Gas Surface Interactions Occurring on Materials Within Ultrahigh Vacuum

The physical adsorption of nitrogen on the chemically cleaned surfaces of Pyrex, 347 stainless steel and polycrystalline nickel was investigated over the pressure range 1 x 10 to the minus 12th power to 3 x 10 to the minus 7th power torr and for temperatures 77.4 and 87.4 K. The adsorption data were linearized by the Dubinin-Radushkevich equation. The metal surfaces were cleaned by electron impact desorption (EID) and the desorbed gases analyzed by mass spectrometry. Work function measurements were also used to indicate changes in the surface condition following an EID dose. At least a monolayer of gas was observed to desorb from the metal surfaces. The isotherms revealed that the metal surfaces were very heterogeneous and that the Pyrex surface had been leached. The calculated isosteric heats of adsorption indicated that the relative order of the physical binding of nitrogen to the solids was 347 stainless steel Pyrex nickel. A relationship was observed to exist in the dynamic technique between the equilibration time and the pressure above the absorbed layer. The slope of the log-log plot of these parameters was found to be sensitive to the surface heterogeneity and may be related to the activation energy for surface diffusion of physically absorbed molecules.

Outlaw, R. A.↗

Interaction of sulfur dioxide and carbon dioxide with clean silver in ultrahigh vacuum.

It is shown that when a clean polycrystalline silver surface is subjected to sulfur dioxide at a pressure of 1 nanotorr, sulfur is chemisorbed to the silver. Heating the contaminated silver leads to an estimation of the minimum heat of desorption of 59 kcal/mol. Sulfur Auger peak height and relative function measurements of the surface during exposure show that adsorption occurs during 6 microtorr/sec exposure at 1 nanotorr.

Lassiter, W. S.↗