Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “transformer cores”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Case Study: Field Evaluation of a Low-Cost Circuit-Level Electrical Submetering System

Circuit-level metering technologies provide the ability to monitor individual circuits within an electrical panel in a building, providing detailed power and energy consumption data at a much more granular level than was previously achievable in a cost-effective manner. While the fundamental hardware components of circuit-level—split-core current transformers (CTs) and power monitoring meters—have existed for some time, the new offerings in the market have tightly integrated these components, lower costs, and have streamlined data organization, transport, and access via software solutions accessible through web and application programming interfaces (API). NREL evaluated Meazon’s single-circuit metering system. The evaluation of the equipment under test (EUT) focused on three aspects: (1) accuracy of the data provided by the system, (2) ease of installation of this technology and ease of data integration into existing U.S. General Services Administration (GSA) analytics platforms, and (3) total cost of ownership and cost-effectiveness of the technology. The metering technology was tested in a field deployment where it was installed in low and high-voltage commercial electrical panels in the César E. Chávez Memorial Building in Denver, Colorado. The goals were to assess the metering accuracy, the ease of installation and data retrieval, and the total cost of ownership and cost-effectiveness. This technology proved easy to install by a certified electrician who completed the install of 6 meters in 2 separate panels (120/208 V and 277/480 V) and 2 circuit disconnects (along with associated commissioning) at the César E. Chávez Memorial Building in less than one day. The technology was installed in high- and low-voltage panels and with limited space in the electrical room, demonstrating the applicability of this technology to almost all commercial buildings in the GSA portfolio. Primary considerations for this technology include appropriate sizing of CTs for each circuit, selection of loads/circuits/panels that are of high value for detailed submetering (e.g., tailored for high-load devices), and how GSA would like to integrate these data with its existing energy management infrastructure. Through the field evaluation, we demonstrated data integration from the vendor system into the primary software component on the GSA enterprise-level energy management and information system, GSA Link. Data from the circuit-level metering were integrated into this platform and used to perform FDD. This demonstrated the ability of the EUT to augment existing energy management and information systems in buildings where GSA Link is deployed and provides a pathway for delivering FDD at other buildings throughout the portfolio.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An experimental investigation of vortex breakdown on a delta wing

An experimental investigation of vortex breakdown on delta wings at high angles is presented. Thin delta wings having sweep angles of 70, 75, 80 and 85 degrees are being studied. Smoke flow visualization and the laser light sheet technique are being used to obtain cross-sectional views of the leading edge vortices as they break down. At low tunnel speeds (as low as 3 m/s) details of the flow, which are usually imperceptible or blurred at higher speeds, can be clearly seen. A combination of lateral and longitudinal cross-sectional views provides information on the three dimensional nature of the vortex structure before, during and after breakdown. Whereas details of the flow are identified in still photographs, the dynamic characteristics of the breakdown process were recorded using high speed movies. Velocity measurements were obtained using a laser Doppler anemometer with the 70 degree delta wing at 30 degrees angle of attack. The measurements show that when breakdown occurs the core flow transforms from a jet-like flow to a wake-like flow.

Payne, F. M.↗

Experimental study of the velocity field on a delta wing

An experimental study of the leading edge vortices on delta wings at large angles of incidence is presented. A combination of flow visualization, seven-hole pressure probe surveys and laser velocimeter measurements were used to study the leading edge vortex formation and breakdown for a set of delta wings. The delta wing models were thin flat plates with sharp leading edges having sweep angles of 70, 75, 80, and 85 degrees. The flow structure was examined for angles of incidence from 10 to 40 degrees and chord Reynolds numbers from 85,000 to 640,000. Vortex breakdown was observed on all the wings tested. Both bubble and spiral modes of breakdown were observed. The visualization and wake survey data shows that when vortex breakdown occurs the core flow transforms abruptly from a jet-like flow to a wake-like flow. The result also revealed that probe induced vortex breakdown was more steady than the natural breakdown.

Payne, F. M.↗

Diaplectic transformation of minerals: Vorotilov drill core, Puchezh-Katunki impact crater, Russia

The Vorotilov core was drilled in the central uplift of the Puchezh-Katunki astrobleme to a depth of 5.1 km. Impactites are revealed in the rocks of the core beginning from a depth of 366 m: suevites (66 m), allogenic breccias (112 m), and autogenic breccias (deeper than 544 m). These rocks are represented by shocked-metamorphic gneisses, schists, amphibolites of Archean age, and magmatic rocks (dolerites, olivines, and peridotites) that lie between them.

Feldman, V. I.↗

Transformer with integral inductor

In accordance with one embodiment is a transformer with a core comprising a perimeter portion and central intervening portion. The central intervening portion is separated from the perimeter portion by air gaps, creating an opening on either side of the intervening portion. A primary winding and secondary winding are wound around the central intervening portion of the core. The primary winding is capable of electromagnetic interaction with the secondary winding. A pair of ferrite members arranged outward from a central axis of the central intervening portion of the core and increases a series inductance with the primary winding. In accordance with another aspect of the disclosure, each ferrite member may have an air gap associated with the core to facilitate heat dissipation from the transformer.

Rastogi, Sagar K.↗

Relations between the photospheric magnetic field and the emission from the outer atmospheres of cool stars. I - The solar Ca II K line core emission

Observations of a solar active region complex and its surroundings are used to establish a quantitative relation between the Ca II K line core intensity and magnetic flux density. The Ca II K line core intensity is transformed to a Ca II H + K line core flux density to facilitate a comparison of solar and stellar data. A new absolute calibration for the Mount Wilson Ca II H + K fluxes for G-type dwarfs is derived. The minimum Ca II K flux, found in the centers of supergranulation cells in quiet regions on the sun, is identical to the minimum flux that is observed for solar-type stars. An expression is presented for the nonlinear trend between the Ca II H + K line core excess flux density and the absolute value of the magnetic flux density. Models that explain the nonlinearity of the mean trend and the large intrinsic scatter about it are discussed. The solar data define a relation that is similar to the relation between stellar hemisphere-average magnetic flux densities and Ca II H + K excess flux densities.

Schrijver, C. J.↗

Transformational challenge reactor analysis to inform preconceptual core design decisions: Sensitivity study of transient analysis in a hydride-moderated microreactor

The Transformational Challenge Reactor (TCR) program aims to demonstrate a revolutionary design approach enabled by advanced manufacturing and data analytics in the design of nuclear reactors. This article discusses scoping analyses of preconceptual designs to inform TCR design decisions and the evaluation of sensitivities and uncertainties on postulated transient scenarios. The applicability of the systems codes TRACE and RELAP5-3D to TCR transient analysis are examined, and RELAP5-3D models are used to examine the transient response of two candidate core designs at multiple power levels. Then, the uncertainty quantification code RAVEN is used to quantify the effect of several design parameters on reactivity-initiated accident (RIA) progression at hot zero power (HZP) and hot full power (HFP) as well as to assess the impact of uncertainties in transient parameters for the pressurized loss of forced cooling (PLOFC).When results were compared, TRACE and RELAP5-3D showed good agreement in their ability to predict system behavior, but RELAP5-3D calculations were closer to analytical predictions for the RIA. Furthermore, models for a PLOFC accident in two designs (a UO2 and TRISO core) at multiple power levels showed greater temperature margins for the TRISO core at all power levels. Using this information, along with other scoping analyses and constraints, the TCR design team selected a power level of 3 MWth and a TRISO-based core design. For this design RAVEN was applied to vary RIA parameters in RELAP5-3D models at HZP and HFP to understand the effect on figures of merit such as peak power, fuel and coolant temperature, and energy deposition. This sensitivity study found that the inserted reactivity worth was the most important parameter controlling all figures of merit, but for insertion up to 1.5$ no failure of TCR fuel is anticipated. For constant reactivity insertions, the magnitude of the fuel temperature coefficient was found to have the greatest effect on all figures of merit under most circumstances. These results not only demonstrate the anticipated robust safety of the proposed TCR fuel form but also provide a reference for future metal-hydride moderated systems to understand RIA behavior. In the PLOFC, the impact of heat transfer enhancement due to wavy flow channel effects dominated the variance in peak temperatures, and variations in heat exchanger elevation provided the greatest control on natural circulation flow rate. Additionally, no fuel particle failure is anticipated in the PLOFC.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Volume and Mass Estimation of Three-Phase High Power Transformers for Space Applications

Spacecraft historically have had sub-1kW(sub e), electrical requirements for GN&C, science, and communications: Galileo at 600W(sub e), and Cassini at 900W(sub e), for example. Because most missions have had the same order of magnitude power requirements, the Power Distribution Systems (PDS) use existing, space-qualified technology and are DC. As science payload and mission duration requirements increase, however, the required electrical power increases. Subsequently, this requires a change from a passive energy conversion (solar arrays and batteries) to dynamic (alternator, solar dynamic, etc.), because dynamic conversion has higher thermal and conversion efficiencies, has higher power densities, and scales more readily to higher power levels. Furthermore, increased power requirements and physical distribution lengths are best served with high-voltage, multi-phase AC to maintain distribution efficiency and minimize voltage drops. The generated AC-voltage must be stepped-up (or down) to interface with various subsystems or electrical hardware. Part of the trade-space design for AC distribution systems is volume and mass estimation of high-power transformers. The volume and mass are functions of the power rating, operating frequency, the ambient and allowable temperature rise, the types and amount of heat transfer available, the core material and shape, the required flux density in a core, the maximum current density, etc. McLyman has tabulated the performance of a number of transformers cores and derived a "cookbook" methodology to determine the volume of transformers, whereas Schawrze had derived an empirical method to estimate the mass of single-phase transformers. Based on the work of McLyman and Schwarze, it is the intent herein to derive an empirical solution to the volume and mass estimation of three-phase, laminated EI-core power transformers, having radiated and conducted heat transfer mechanisms available. Estimation of the mounting hardware, connectors, etc. is not included.

Kimnach, Greg L.↗

Transformer and an associated method thereof

A transformer having an insulation system is presented. The transformer includes a magnetic core having an opening. Also, the transformer includes a plurality of primary windings disposed extending through the opening of the magnetic core. Further, the insulation system includes a first insulation substantially encapsulating the plurality of primary windings and impregnating spaces between the plurality of primary windings, and a second insulation disposed around the first insulation, where the second insulation has at least one of a predetermined dielectric strength and a predetermined thickness configured to isolate a first voltage signal in the plurality of primary windings from the magnetic core.

Chen, Qin↗

United States cool surfaces deployment plan

Solar-reflective building envelope surfaces, such as cool roofs and walls, can be especially helpful in disadvantaged communities that often have poorly insulated older homes, aging or absent air conditioning units, steep utility bills, polluted air, and high vulnerability and exposure to extreme heat. With support from the U.S. Department of Energy, our project seeks to dramatically increase the climate-appropriate deployment of cool surfaces across the United States with an emphasis on their application to disadvantaged communities. First, we sought to identify cool-surface deployment barriers, opportunities, and models by (a) reviewing the history of cool-surface deployment activities, (b) interviewing cool-surface stakeholders, (c) researching successful energy-efficiency/green building deployment models; and (d) interviewing the actors who have implemented these models. Second, we conducted a workshop to engage stakeholders in development of a deployment plan. Third, we asked several U.S. federal agencies (a) how cool surfaces and cool surface stakeholders could support their missions and (b) how agency activities could support cool-surface deployment. Fourth, we identified a set of transformative ideas that form the core of the deployment plan. Transformative ideas include but are not limited to initiatives to (a) launch an educational campaign to make the general public and building professionals aware of how cool roofs and walls exclude unwanted solar heat; (b) create a “Cool Roof Prize” stimulating the development of affordable, high-performance cool asphalt roofing shingles; (c) conduct high-profile, large-scale demonstration programs that bring cool surfaces to disadvantaged heat-vulnerable communities; and (d) support local, regional, and state climate action (heat mitigation) plans with cool surfaces.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Volcano‐like Activity Trends in Au@Pd Catalysts: The Role of Pd Loading and Nanoparticle Size

The addition of palladium (Pd) to preformed gold nanoparticles (Au NPs) enables the formation of core‐shell structures with enhanced catalytic performance in oxidation reactions. However, predicting the precise palladium content required to achieve maximum catalytic activity remains difficult based on current understanding. Herein, Pd was systematically introduced onto titania‐supported Au NPs (2, 6, and 10 nm) to evaluate their performance in benzyl alcohol oxidation. A volcano‐like trend in catalytic activity was observed, where activity increased with Pd addition, peaked, and then declined. The Pd loading required for maximum activity depended on Au NP size: ≈40 at% Pd/Au for 2.6 nm, ≈20 at% Pd/Au for 6.4 nm, and ≈12.5 at% Pd/Au for 10.6 nm. For Au NPs > 6 nm, peak activity aligned with monolayer Pd coverage, while for smaller NPs (2–3 nm), optimal Pd content was below monolayer predictions. X‐ray absorption spectroscopy revealed a core‐shell structure at low Pd content, but higher Pd loadings led to Pd diffusion into the Au core. This structural transformation likely caused activity decline, indicating that AuPd alloying negatively impacts catalysis. These results highlight that core‐shell Au@Pd catalysts outperform AuPd alloys and provide crucial insights for designing highly active bimetallic catalysts.

X-ray absorption spectroscopy↗

Challenges to Rural Service Transformers on Increased Electric Vehicle Charging Infrastructure

As Electric Vehicle (EV) electric charging demand increases so to does the corresponding load requirements for charging the vehicles. The expansion of power distribution assets is therefore a critical issue to address on whether rural service transformers can handle the increase in EV load demand. Large-scale EV deployment is likely to cause problems in the localized distributions systems bringing challenges such as increased load demand, increased system losses, and additional voltage drops. This paper investigates how rural service transformer resiliency plays an important role in these challenges. EV charging can create new load peaks exceeding the service transformer's rated capacity, thereby accelerating equipment aging. EV charging can also both positively and negatively affect transformer aging. The core purpose of this paper is to investigate that change in service life of rural service transformers.

Mukherjee, Srijib↗

Additive manufacturing of amorphous metal soft magnetic composites

Soft magnet alloys are used as magnetic cores for electric motors, transformers, wind turbines and other power generation systems. Soft magnetic cores are expensive and time consuming to manufacture in the complex shapes required for next-generation devices using conventional press and sinter powder metallurgy. The objective of this effort is to additively manufacture high performance soft magnets, with reduced cost and reduced material waste and 10x lower energy (core) loss at the high operating frequencies of many electric machines. Laser powder bed fusion additive manufacturing is used as the fabrication method. Electrical steel and amorphous alloys atomized powders are used as a feedstock materials. Magnetic cores are printed in topology optimized structures such as the Hilbert curve because this has been shown to reduce energy losses by minimizing the eddy currents that circulate within the magnet at high frequencies. In our project, we succeed in printing FeSi 3.5wt% and FeSi 6.5wt% electrical steels, and iron-based soft magnetic amorphous alloys in the shape of Hilbert and Peano curve topology optimized structures. We found that the Peano curve has a higher cut-off frequency than the Hilbert curve, and that amorphous alloys have high cut-off frequencies and higher mechanical hardness than electrical steels. Processing conditions such as laser power, scan speed, and hatching pattern were optimized to achieve high density prints, and optimize magnetic performance. We find that the printing of amorphous alloy soft magnetic cores may be technoeconomically feasible for large scale applications such as transformers, for which supply chain issues and the labor costs of manual fabrication of magnetic cores is prohibitive in some cases.

36 MATERIALS SCIENCE↗

Direct-Current Monitor With Flux-Reset Transformer Coupling

Circuit measures constant or slowly-varying unidirectional electrical current using flux-reset transformer coupling. Measurement nonintrusive in sense that no need for direct contact with wire that carries load current to be measured, and no need to install series resistive element in load-current path. Toroidal magnetic core wrapped with coil of wire placed around load-current-carrying wire, acts as transformer core, load-current-carrying wire acts as primary winding of transformer, and coil wrapped on core acts as secondary winding.

Canter, Stanley↗