Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “transducer error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Porous plug for reducing orifice induced pressure error in airfoils

A porous plug is provided for the reduction or elimination of positive error caused by the orifice during static pressure measurements of airfoils. The porous plug is press fitted into the orifice, thereby preventing the error caused either by fluid flow turning into the exposed orifice or by the fluid flow stagnating at the downstream edge of the orifice. In addition, the porous plug is made flush with the outer surface of the airfoil, by filing and polishing, to provide a smooth surface which alleviates the error caused by imperfections in the orifice. The porous plug is preferably made of sintered metal, which allows air to pass through the pores, so that the static pressure measurements can be made by remote transducers.

Elizabeth B Plentovich↗

Identifying subassemblies by ultrasound to prevent fuel handling error in sodium fast reactors: First test performed in water

Identifying subassemblies by ultrasound is a method that is being considered to prevent handling errors in sodium fast reactors. It is based on the reading of a code (aligned notches) engraved on the subassembly head by an emitting/receiving ultrasonic sensor. This reading is carried out in sodium with high temperature transducers. The resulting one-dimensional C-scan can be likened to a binary code expressing the subassembly type and number. The first test performed in water investigated two parameters: width and depth of the notches. The code remained legible for notches as thin as 1.6 mm wide. The impact of the depth seems minor in the range under investigation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Universal signal conditioning amplifier

A state-of-the-art instrumentation amplifier capable of being used with most types of transducers has been developed at the Kennedy Space Center. This Universal Signal Conditioning Amplifier (USCA) can eliminate costly measurement setup item and troubleshooting, improve system reliability and provide more accurate data than conventional amplifiers. The USCA can configure itself for maximum resolution and accuracy based on information read from a RAM chip attached to each transducer. Excitation voltages or current are also automatically configured. The amplifier uses both analog and digital state-of-the-art technology with analog-to-digital conversion performed in the early stages in order to minimize errors introduced by offset and gain drifts in the analog components. A dynamic temperature compensation scheme has been designed to achieve and maintain 12-bit accuracy of the amplifier from 0 to 70 C. The digital signal processing section allows the implementation of digital filters up to 511th order. The amplifier can also perform real-time linearizations up to fourth order while processing data at a rate of 23.438 kS/s. Both digital and analog outputs are available from the amplifier.

Medelius, Pedro J.↗

Acoustically determined linear piezoelectric response of lithium niobate up to 1100 V

We present a method to measure high voltages using the piezoelectric crystal lithium niobate without using voltage dividers. A 36° Y-X cut lithium niobate crystal was coupled to two acoustic transducers, where direct current voltages were applied from 128–1100 V. The time-of-flight through the crystal was determined to be linearly dependent on the applied voltage. A model was developed to predict the time-delay in response to the applied voltage. The results show a sensitivity of 17 fs/V with a measurement error of 1 fs/V was achievable using this method. The sensitivity of this method can be increased by measuring the acoustic wave after multiple passes through the crystal. This method has many advantages over traditional techniques such as: favorable scalability for larger voltages, ease of use, cost effectiveness, and compactness.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laser measurements of ozone absorption cross sections in the Chappuis band

A sensitive spectrometer has been developed that exploits several He-Ne laser transitions in the visible for precise, high resolution measurements of Chappuis band ozone absorption cross sections at room temperature. An overall uncertainty of better than one percent has been achieved through a combination of transducer calibrations and an experimental technique that unambiguously determines the impurity content of each ozone sample. Results compare favorably with those from most previous analyses in the visible range, though some are obviously lower than this consensus due probably to errors in ozone density measurements.

Anderson, Stuart M.↗

Organic electrochemical transistors for cell-based impedance sensing

Electrical impedance sensing of biological systems, especially cultured epithelial cell layers, is now a common technique to monitor cell motion, morphology, and cell layer/tissue integrity for high throughput toxicology screening. Existing methods to measure electrical impedance most often rely on a two electrode configuration, where low frequency signals are challenging to obtain for small devices and for tissues with high resistance, due to low current. Organic electrochemical transistors (OECTs) are conducting polymer-based devices, which have been shown to efficiently transduce and amplify low-level ionic fluxes in biological systems into electronic output signals. In this work, we combine OECT-based drain current measurements with simultaneous measurement of more traditional impedance sensing using the gate current to produce complex impedance traces, which show low error at both low and high frequencies. We apply this technique in vitro to a model epithelial tissue layer and show that the data can be fit to an equivalent circuit model yielding trans-epithelial resistance and cell layer capacitance values in agreement with literature. Importantly, the combined measurement allows for low biases across the cell layer, while still maintaining good broadband signal.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultrasonic analysis of bolt preloads

This paper covers an investigation into the feasibility of analyzing bolt preloads by ultrasonic techniques. Various techniques were evaluated and a pulse echo inteferometric method was selected for experimental testing. In agreement with theoretical predictions, the interferometer response was found to be linearly related to tensile stresses oriented parallel to the bolt axis. Under rather idealized conditions, bolt loads can be determined with errors of less than 1%. The ultimate operational accuracy depends on a number of variables, such as bolt dimensions and geometry, bolt temperature, uniformity of stresses, and bolt materials, but load analyses to within + or - 3% are readily achievable. Best results are obtained with the ultrasonic transducer contact coupled to a small flat area near the center of the bolt head. The transducer can be applied and measurements made without interfering with normal wrenching operations. Prototype instrumentation is described and calibration results are tabulated for numerous bolt sizes and materials.

Rollins, F. R., Jr.↗

SU-G-JeP1-07: Development of a Programmable Motion Testbed for the Validation of Ultrasound Tracking Algorithms

Purpose: To develop an advanced testbed that combines a 3D motion stage and ultrasound phantom to optimize and validate 2D and 3D tracking algorithms for real-time motion management during radiation therapy. Methods: A Siemens S2000 Ultrasound scanner utilizing a 9L4 transducer was coupled with the Washington University 4D Phantom to simulate patient motion. The transducer was securely fastened to the 3D stage and positioned to image three cylinders of varying contrast in a Gammex 404GS LE phantom. The transducer was placed within a water bath above the phantom in order to maintain sufficient coupling for the entire range of simulated motion. A programmed motion sequence was used to move the transducer during image acquisition and a cine video was acquired for one minute to allow for long sequence tracking. Images were analyzed using a normalized cross-correlation block matching tracking algorithm and compared to the known motion of the transducer relative to the phantom. Results: The setup produced stable ultrasound motion traces consistent with those programmed into the 3D motion stage. The acquired ultrasound images showed minimal artifacts and an image quality that was more than suitable for tracking algorithm verification. Comparisons of a block matching tracking algorithm with the known motion trace for the three features resulted in an average tracking error of 0.59 mm. Conclusion: The high accuracy and programmability of the 4D phantom allows for the acquisition of ultrasound motion sequences that are highly customizable; allowing for focused analysis of some common pitfalls of tracking algorithms such as partial feature occlusion or feature disappearance, among others. The design can easily be modified to adapt to any probe such that the process can be extended to 3D acquisition. Further development of an anatomy specific phantom better resembling true anatomical landmarks could lead to an even more robust validation. This work is partially funded by NIH grant R01CA190298.

60 APPLIED LIFE SCIENCES↗

A signal filter with zero phase lag

Rotorcraft and rotorcraft models are tested at the NASA Ames National Full-Scale Aerodynamics Complex (NFAC). The models tested in the NFAC wind tunnels are controlled by a remote control console located in a control room. Certain critical information must be displayed on the control console to monitor the rotor to insure that the rotor is within operational limits. The signal for these parameters is complex (with ac and dc components) and is derived from pitch and flapping transducers on the rotor head. The pitch and flapping cyclics are derived from resolver circuits that indicate the magnitude and phase of the cyclics. Conventional filter circuits used to separate the ac and dc components have a phase lag on the ac component, which will introduce an error in the cyclic vector. To overcome this error, a filter with zero phase lag needed to be developed. This paper discusses a rotorcraft circuit that was designed to have an ac/dc filter with zero phase lag over the frequency range.

Forsyth, T. J.↗

Quantifying energy and mass transfer in crop canopies: sensors for measurement of temperature and air velocity

Here we report on the in situ performance of inexpensive, miniature sensors that have increased our ability to measure mass and energy fluxes from plant canopies in controlled environments: 1. Surface temperature. Canopy temperature measurements indicate changes in stomatal aperture and thus latent and sensible heat fluxes. Infrared transducers from two manufacturers (Exergen Corporation, Newton, MA; and Everest Interscience, Tucson, AZ, USA) have recently become available. Transducer accuracy matched that of a more expensive hand-held infrared thermometer. 2. Air velocity varies above and within plant canopies and is an important component in mass and energy transfer models. We tested commercially-available needle, heat-transfer anemometers (1 x 50 mm cylinder) that consist of a fine-wire thermocouple and a heater inside a hypodermic needle. The needle is heated and wind speed determined from the temperature rise above ambient. These sensors are particularly useful in measuring the low wind speeds found within plant canopies. 3. Accurate measurements of air temperature adjacent to plant leaves facilitates transport phenomena modeling. We quantified the effect of radiation and air velocity on temperature rise in thermocouples from 10 to 500 micrometers. At high radiation loads and low wind speeds, temperature errors were as large as 7 degrees C above air temperature.

NASA Program CELSS↗

Ultrasonic transducer with a two-dimensional Gaussian field profile

A transducer is described which generates a two-dimensional Gaussian field by controlling both the position of multiple circular electrodes and the voltage applied to each electrode. The transducer is constructed by depositing concentric rings electrodes onto one flat surface of a circular piezoelectric crystal disk and attaching the rings to an impedance matching network which acts as a voltage divider. Geometrical inter-ring separations and electrical inter-ring impedances are designed to minimize the error between the generated acoustic field, modeled as a piecewise linear function, and the desired Gaussian distribution. Total mean squared error between the averaged far-field data and a Gaussian shape is less than two percent.

Claus, R. O.↗

Electromagnetic Flow Meter Having a Driver Circuit Including a Current Transducer

An electromagnetic flow meter (EMFM) accurately measures both the complete flow rate and the dynamically fluctuating flow rate of a fluid by applying a unipolar DC voltage to excitation coils for a predetermined period of time, measuring the electric potential at a pair of electrodes, determining a complete flow rate and independently measuring the dynamic flow rate during the "on" cycle of the DC excitation, and correcting the measurements for errors resulting from galvanic drift and other effects on the electric potential. The EMFM can also correct for effects from the excitation circuit induced during operation of the EMFM.

Karon, David M.↗

Transmission of Images on High-Temperature Nuclear-Grade Metallic Pipe with Ultrasonic Elastic Waves

Transmission of information using elastic ultrasonic waves on existing metallic pipes provides an alternative communication option for a nuclear facility. The advantages of this approach consist of transmitting information through barriers, such as the containment building wall, with minimal modification of the existing hardware. Because bit rates on the order of kilobits per second are achievable, relatively large volumes of data, such as images, can be transmitted. A viable candidate for an ultrasonic communication channel is a stainless steel pipe of the chemical volume control system (CVCS) that penetrates through the reactor containment building wall through a sealed tunnel. To study ultrasonic communication under simulated nuclear facility conditions of high temperature, a test article was developed by installing heating tapes, temperature controllers, and thermal insulation on a laboratory CVCS-like stainless steel pipe. High temperature and radiation-resilient lithium niobate ultrasonic transducers were utilized for information transmission on the heated pipe. The amplitude shift keying (ASK) digital communication protocol was developed and implemented in a GNU Radio software-defined radio environment. A root-raised-cosine filter was introduced to suppress ultrasonic transducer ringing and thus reduce inter-symbol interference. This resulted in the enhancement of the data transmission bit rate compared to information encoding with square pulses. Demonstrations of communication at high temperature included transmission of a 90-KB image at the bit rate of 10 Kbps with a bit error rate of 10 -3 across a 6-ft-long straight pipe heated up to 230 degrees C. Additional preliminary studies were conducted to evaluate ultrasonic communication system resilience to environmental degradation and damage.

42 ENGINEERING↗

Language Model Combination and Adaptation Using Weighted Finite State Transducers

In speech recognition systems language model (LMs) are often constructed by training and combining multiple n-gram models. They can be either used to represent different genres or tasks found in diverse text sources, or capture stochastic properties of different linguistic symbol sequences, for example, syllables and words. Unsupervised LM adaption may also be used to further improve robustness to varying styles or tasks. When using these techniques, extensive software changes are often required. In this paper an alternative and more general approach based on weighted finite state transducers (WFSTs) is investigated for LM combination and adaptation. As it is entirely based on well-defined WFST operations, minimum change to decoding tools is needed. A wide range of LM combination configurations can be flexibly supported. An efficient on-the-fly WFST decoding algorithm is also proposed. Significant error rate gains of 7.3% relative were obtained on a state-of-the-art broadcast audio recognition task using a history dependently adapted multi-level LM modelling both syllable and word sequences

Liu, X.↗

Sparsely Sampled Phase-Insensitive Ultrasonic Transducer Arrays

Three methods of interpretation of outputs from sparsely sampled two-dimensional array of receiving ultrasonic transducers used in transmission experiments investigated. Methods are: description of sampled beam in terms of first few spatial moments of sampled distribution of energy; use of signal-dependent cutoff to limit extent of effective receiver aperture; and use of spatial interpolation to increase apparent density of sampling during computation. Methods reduce errors in computations of shapes of ultrasonic beams.

Patrick H. Johnston↗

SU-D-210-07: The Dependence On Acoustic Velocity of Medium On the Needle Template and Electronic Grid Alignment in Ultrasound QA for Prostate Brachytherapy

Purpose: To analyze the impact on acoustic velocity (AV) of two different media (water and milk) using the needle template/electronic grid alignment test. Water, easily available, makes a good material to test the alignment of the template and grid although water’s AV (1498 m/s at 25°C) is significantly different from tissue (1540 m/s). Milk, with an AV much closer (1548 m/s) to prostate tissue, may be a good substitute for water in ultrasound quality assurance testing. Methods: Tests were performed using a Hitachi ultrasound unit with a mechanical arrangement designed to position needles parallel to the transducer. In this work, two materials – distilled water and homogenized whole milk (AVs of 1498 and 1548 m/s at 25°C) were used in a phantom to test ultrasound needle/grid alignment. The images were obtained with both materials and analyzed for their placement accuracy. Results: The needle template/electronic grid alignment tests showed displacement errors between measured and calculated values. The measurements showed displacements of 2.3mm (water) and 0.4mm (milk), and 1.6mm (water) and 0.3mm (milk) at depths of 7cm and 5cm respectively from true needle positions. The calculated results showed a displacement of 2.36 mm (water); 0.435mm (milk), and 1.66mm (water) and 0.31mm (milk) at a depth of 7cm and 5cm respectively. The displacements in the X and Y directions were also calculated. At depths of 7cm and 5cm, the (ΔX,ΔY) displacements in water were (0.829mm, 2.21mm) and (0.273mm, 1.634mm) and for milk were (0.15mm, 0.44mm) and (0.05mm, 0.302mm) respectively. Conclusion: The measured and calculated values were in good agreement for all tests. They show that milk provides superior results when performing needle template and electronic grid alignment tests for ultrasound units used in prostate brachytherapy.

60 APPLIED LIFE SCIENCES↗

Pulse Shaping and Matched Filters for EMAT Communication System

Electromagnetic acoustic transducer (EMAT) is used as a noncontact sensor for acoustic communication in a stainless-steel plate channel. The acoustic wave multipath propagations within the channel cause intersymbol interference (ISI). ISI highly degrades the signal-to-noise ratio (SNR). The poor SNR will result in a low bitrate and a high bit error rate (BER). In this study, a test platform is designed to estimate the performance of the EMAT communication system. Two periodic-permanent-magnet (PPM) EMATs are designed to be used as a transmitter and a receiver. EMAT generates shear-horizontal (SH) wave propagating through the stainless-steel plate channel. We present methods to minimize the ISI effect and recover the message embedded in the received signals hampered by interference, reverberation and multipath effects. The root raised cosine (RRC) filters are introduced as a pulse-shaping filter for transmission and a matched filter for receiving messages. Amplitude Shift Keying (ASK) method is used for modulating the transmitted binary message. The pulse shaping and matched filters reduced the ISI caused by the undesirable multipath effect significantly to the extent that a 5-kbps bitrate can be achieved without any error (zero BER).

Huang, Xin↗

Excerpt from Oxygen Monitor Clean Testing Report Performed in 2010

The Rosemount X-STREAM Series X2GP is a paramagnetic oxygen analyzer with a 0-25% oxygen measurement range. It claims a drift less than 2% of span (0.10% volume oxygen) per week, and a response time of less than 5 seconds (for the analyzer to report 90% of a step change). Our test equipment was set-up such that the same gas was running through each oxygen analyzer at the same time. This allowed Calibration Error, Calibration Drift, and Loss of Power Testing to be run on all monitors at the same time, eliminating any variability between the analyzers from tolerances in the gas cylinder, ambient temperature, ambient pressure, test duration, etc. An APTech pressure regulator was placed on the gas cylinder manifold and a 23 psia Paroscientific pressure transducer measured the regulator’s outlet pressure. This did not give the inlet pressure on any one analyzer but outlet pressure from the manifold before the stream was split. The APTech pressure regulator was used to keep operating conditions consistent. A DWYER rotameter was installed on each oxygen monitor’s outlet piping. With the exception of Variation of Flow Rate Testing, the rotameter was left fully open for all testing. The flow rate through each oxygen monitor was controlled by a Swagelok needle valve that was installed on each analyzer’s inlet piping. Additionally, a filter was installed in the each monitor’s inlet piping to keep particles from the measurement cells and a Swagelok ball valve was installed on each monitor’s outlet piping to isolate each monitor between tests. No pumps were installed. Each of the cylinders used was at a pressure greater than ambient room barometric pressure. This pressure differential was used to move gas through the testing equipment. The flow rate through each analyzer was controlled by the Swagelok needle valve installed on each analyzer’s inlet piping. Finally, for all tests, a Paroscientific Digiquartz Barometer was used to measure ambient room barometric pressure and a Fluke Thermo-hygrometer was used to measure ambient room temperature.

47 OTHER INSTRUMENTATION↗