Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “traces”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Quasi-optical beam tracing module development for millimeter-wave high-wavenumber collective scattering on the NSTX-U and EAST tokamaks

A Python3-based beam tracing code utilizing Quasi-Optics has been developed to track both incident and receiving beams in high-k collective millimeter wave scattering systems within magnetic fusion plasmas. In contrast to existing ray tracing codes that solely consider refraction, this beam tracing code incorporates diffraction phenomena, providing a more comprehensive calculation. Here, this enhanced capability allows for a more accurate calculation of the scattering volume and spatial resolution in high-k collective scattering systems, crucial for evaluating system performance and facilitating data analysis. Unlike Geometrical Optics, Quasi-Optics employs the complex eikonal method, representing a Gaussian beam as a collection of coupled rays to accurately preserve diffraction characteristics. The developed code is intended for application in NSTX-Upgrade and EAST high-k beam tracing analyses, targeting frequencies of 693 GHz and 270 GHz, respectively. The high-k system's primary objective is the observation of electron-scale instabilities. Employing a symplectic integrator, the code ensures numerical accuracy, assessed through the conservation of the Hamiltonian. With its precision and efficiency, the code facilitates rapid inter-shot analyses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Monte Carlo Based Ray Tracing Tool for Evaluating Wolter-Type Prescriptions

Evaluating Wolter-like X-ray mirror prescriptions via ray tracing is useful for selecting and optimizing the right mirror prescriptions for a specified application. Moreover, incorporating real metrology data into a ray trace and simulating point spread functions (PSF) allows for performance predictions representative of real manufacturing errors and tolerances. In fulfillment of an internship project, an X-ray ray trace routine using a Monte-Carlo method has been developed to examine different Wolter-like prescriptions and characterize their theoretical performances over a specified field of view. This routine includes the ability to use real metrology data to evaluate the impact of figure error on imaging performance. As a test case, the Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) Wolter-I mirror prescription and an equivalent Wolter-Schwarzschild prescription were traced and imaging performance of a specified field of view were mapped. Here we present the approach used in this routine, showcase example results, and discuss future goals for expanding the routine to address azimuthally varying figure errors and surface roughness.

X-ray optics↗

Dirac traces and the Tutte polynomial

Perturbative calculations involving fermion loops in quantum field theories require tracing over Dirac matrices. A simple way to regulate the divergences that generically appear in these calculations is dimensional regularisation, which has the consequence of replacing 4-dimensional Dirac matrices with d-dimensional counterparts for arbitrary complex values of d. In this work, a connection between traces of d-dimensional Dirac matrices and computations of the Tutte polynomial of associated graphs is proven. The time complexity of computing Dirac traces is analysed by this connection, and improvements to algorithms for computing Dirac traces are proposed.

Renormalization and Regularization↗

Trace elements and their isotopes in streams and rivers

The occurrence and speciation of trace elements in streams and rivers are controlled by interconnected hydrogeological, biogeochemical, and anthropogenic factors that include rock weathering, climate, vegetation, and land use within the watershed. This chapter provides a broad overview of trace element abundance, speciation, and mobility in streams and rivers, including an assessment of how trace elements are partitioned into dissolved, colloidal, and particulate phases. We also discuss how trace elements are mobilized into stream networks and transformed during transport. Select isotopic systems are reviewed to provide examples of how isotopic analyses can be used to understand geochemical and anthropogenic processes.

Herndon, Elizabeth [ORNL] (ORCID:0000000291945493)↗

Analysis of dislocation configurations in SiC crystals through X-ray topography aided by ray tracing simulations

Silicon carbide as a wide bandgap semiconductor is of great research interest for its widespread deployment in a range of electronic and optoelectronic devices, particularly in power electronics. However, defects in silicon carbide crystals are still major concerns that is hampering the development of high-performance devices. X-ray topography, particularly using the synchrotron beam has been instrumental in characterizing and analyzing defect configurations in silicon carbide crystals to optimize crystal growth as well as understand the effect of defects on device performance. Here, in recent years, the use of ray-tracing simulation technique based on the orientation contrast mechanism to simulate contrast of defects observed on actual X-ray topographs has proven to be an effective approach to investigate the nature of crystallographic defects in various semiconductors. This review discusses the principle of ray-tracing simulation and its application and modifications to incorporate the effects of surface relaxation and photoelectric absorption to better simulate different dislocations observed in 4H–SiC as well as 6H–SiC crystals of various orientations. The adaptation to weak beam topography and plane wave topography is also discussed. The application of ray-tracing simulation in dislocation characterization of silicon carbide of different polytypes is systematically reviewed including different types of dislocations observed in both off-axis wafers and axial-sliced samples through synchrotron X-ray topography under various beam conditions, recording geometries and reflections. The result of ray-tracing simulation is further utilized in other studies including the investigation of effective penetration depth of all types of dislocations lying on the basal plane on grazing-incidence X-ray topography.

Engineering↗

Rapid and automated separation of uranium ore concentrates for trace element analysis by inductively coupled plasma – optical emission spectroscopy/triple quadrupole mass spectrometry

The present study documents an automated approach to performing elemental analysis on a large group uranium ore concentrate (UOC) samples. In this work, 17 UOC samples, 2 quality control samples, and 26 process blanks were purified sequentially through a single 500 μL Uranium and TEtra Valent Actinides (UTEVA®) column. For each sample, the trace elemental impurities were separated from its dissolved uranium matrix on the UTEVA column and collected for analysis by inductively coupled plasma – optical emission spectroscopy / triple quadrupole mass spectrometry (ICP-OES/TQMS). The UTEVA column was subsequently regenerated prior to separation of the following sample. The column was efficiently regenerated, for each UOC, even after processing ~50 mg of uranium, cumulatively. The validity of the method was established by determining the trace impurities of two quality control uranium reference samples (CRM 124–1 and CUP-2). The current trace element measurements from the 17 UOC samples were compared to previously reported values from an interlaboratory comparison exercise, when available. The methodology employed here produces trace elemental analysis with excellent correlation to the previously reported data for many of the elements / samples, particularly when viewed through the context of existing geochemical comparisons tools (e.g. chondrite normalized variation plots).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rapid quantitative analysis of trace elements in plutonium alloys using a handheld laser-induced breakdown spectroscopy (LIBS) device coupled with chemometrics and machine learning

Here, we present the first reported quantification of trace elements in plutonium via a portable laser-induced breakdown spectroscopy (LIBS) device and demonstrate the use of chemometric analysis to enhance the handheld device's sensitivity and precision. Quantification of trace elements such as iron and nickel in plutonium metal via LIBS is a challenging problem due to the complex nature of the plutonium optical emission spectra. While rapid analysis of plutonium alloys has been demonstrated using portable LIBS devices, such as the SciAps Z300, their detection limits for trace elements are severely constrained by their achievable pulse power and length, light collection optics, and detectors. In this paper, analytical methods are evaluated as a means to circumvent the detection constraints. Three chemometric methods often used in analytical spectroscopy are evaluated; principal component regression, partial least-squares regression, and artificial neural networks. These models are evaluated based on goodness-of-fit metrics, root mean-squared error, and their achievable limits of detection (LoDs). Partial least squares proved superior for determining content of iron and nickel in plutonium metal, yielding LoDs of 15 and 20 ppm, respectively. These results of identifying the undesirable trace elements in plutonium components are critical for applications such as fabricating radioisotope thermoelectric generators or nuclear fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quantification of trace iodine using laser-induced breakdown spectroscopy for real-time monitoring of nuclear off-gas streams

This study evaluated the potential of laser-induced breakdown spectroscopy (LIBS) for real-time monitoring of trace gas-phase iodine, which is an element of high significance in nuclear applications due to its long radioactive half-life (as iodine-129), volatility, and biological impact. In anticipation of iodine evolving into off-gas systems in molten salt reactor and nuclear fuel recycling applications, this research aimed to assess LIBS performance in flowing argon and helium matrices; optimize measurement parameters using a multichannel spectrometer; and perform calibrations to assess predictive capabilities and limits of detection (LODs). Experimental results successfully measured gas-phase iodine in flowing argon and helium; however, trace iodine was not detected in air. Optimal delay times were determined to be 10 µs for argon and 1 µs for helium, which are consistent with the expected shorter plasma lifetime in helium relative to argon. An emission line survey was provided with the 206.16, 804.37, 902.24, and 905.83 nm peaks, which were identified as the strongest emission peaks. Calibration models were successfully built in both helium and argon, achieving LODs down to 3 ppm in helium and 5 ppm in argon. The iodine emission at 905.83 nm emerged as the most robust for calibration and was subsequently applied to a time series dataset in argon. The predictive trace confirmed the feasibility of employing LIBS for continuous, online quantification of trace iodine in flowing gas systems.

Andrews, Hunter B. [Oak Ridge National Laboratory ↗

Trace Anomaly as Signature of Conformality in Neutron Stars

We discuss an interpretation that a peak in the sound velocity in neutron star matter, as suggested by the observational data, signifies strongly coupled conformal matter. Here, the normalized trace anomaly is a dimensionless measure of conformality leading to the derivative and the nonderivative contributions to the sound velocity. We find that the peak in the sound velocity is attributed to the derivative contribution from the trace anomaly that steeply approaches the conformal limit. Smooth continuity to the behavior of high-density QCD implies that the matter part of the trace anomaly may be positive definite. We discuss a possible implication of the positivity condition of the trace anomaly on the M–R relation of the neutron stars.

79 ASTRONOMY AND ASTROPHYSICS↗

MemGaze: Rapid and Effective Load-Level Memory Trace Analysis

A major challenge of memory analysis tools is combining high-resolution analysis and low overhead measurement. Currently, hardware/software-based analysis of load-level sequences incurs time slowdowns of O(100×). We present MemGaze, a tool for low-overhead, high-resolution memory analysis. MemGaze uses Intel’s Processor Tracing (PT) instruction ptwrite to collect sampled and compressed memory address traces for load-level, sequence-aware analysis of data reuse. We describe multi-resolution analysis for locations vs. operations, accesses vs. spatio-temporal reuse, and reuse (distance, rate, volume) vs. access patterns. Both trace size and resolution are controllable. We use MemGaze to elucidate the memory effects of different data structures and algorithms. For sampled traces that are ˜1% of a full one, analysis metrics have 1-25% MAPE for histograms of varying dynamic sequence lengths. With current suboptimal kernel support (PT runs continuously), MemGaze’s time overhead is typically 10–95%; 7× at worst. However, when PT runs only during samples, overhead is 10–35% on memory intensive regions and correlates with executed ptwrites.

Kilic, Ozgur O.↗

Coupling of CTF and TRACE for Modeling of Transients

This report documents the improvements that have been made to the capabilities for coupling CTF to systems codes-specifically, the US Nuclear Regulatory Commission (NRC) TRACE code. An initial systems coupling capability had been set up previously using a nonoverlapping domain approach with the codes exchanging data at the core boundaries. The present work adds a new approach using overlapping domains, in which the system code models the core as well. A new input format has been added to allow the user to specify the physical quantities to be exchanged and their location in the system model, which gives the flexibility of applying one-way or two-way coupling between the codes using the desired data exchanges. In addition to applying thermal-hydraulics (T/H) boundary condition (BC) values obtained from TRACE, a capability was added to allow CTF to apply flow resistance feedback to TRACE to match the CTF core pressure drop. Support was added for executing parallel CTF models within the CTF-systems coupling. The system coupling capability was successfully applied to a parallel MSLB transient, demonstrating that both the one-way and two-way coupling behaved as expected and provided substantial improvements to numerical stability and routine compared to the previous nonoverlapping domain coupling. An initial capability was also developed for performing restart calculations in CTF which will be used in the future for restarting CTF-TRACE simulations at specific points in the transient simulation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An Integrated Framework for Memory-Centric Analysis: From Trace Collection to Co-Design

The memory wall phenomenon—where advances in processor performance significantly outpace those in memory subsystems—poses a fundamental challenge for contemporary computing systems. In memory-bound applications, memory subsystem behavior dominates performance, yet existing analysis approaches present significant limitations: detailed microarchitectural simulators require days to weeks to simulate modest workloads; hardware performance counters provide only aggregate statistics that obscure temporal and spatial access patterns; and scaled simulation approaches face challenges in capturing certain behaviors that emerge at larger scales. These limitations reflect a processor-centric design philosophy increasingly misaligned with memory-bound workloads where detailed understanding of memory access patterns, cache hierarchy interactions, and contention is critical for effective optimization. This paper presents an integrated framework for memory-centric analysis that enables effective hardware-software co-design. We describe practical trace collection techniques, including hardware-assisted processor tracing with minimal overhead and portable software-based instrumentation with statistical sampling. We present multi-perspective analysis methods that examine memory behavior from temporal, sequential, spatial, and relational viewpoints, revealing distinct optimization opportunities invisible in aggregate metrics. We detail an architectural modeling framework that uses sampled traces with temporal interpolation and confidence-based filtering to evaluate cache and memory configurations. Evaluation on representative benchmarks demonstrates that this framework achieves practical accuracy (L2 cache errors of 2.64\%, confidence-filtered L3 errors of 9.92\%, bandwidth errors of 7.33\%) while providing substantial speedup (26.8×) over cycle-accurate simulation, enabling rapid design space exploration. We demonstrate how this integrated framework enables systematic identification of both hardware optimizations (memory controller tuning, bank partitioning, NUMA configuration) and software optimizations (data layout restructuring, prefetching strategies, memory-aware scheduling). Through this comprehensive treatment of the memory-centric analysis pipeline—from trace collection through architectural modeling to co-design application—we provide researchers and practitioners with practical techniques for addressing memory bottlenecks in contemporary computing systems.

Gajaria, Dhruv Mayur↗

Versatile soil gas concentration and isotope monitoring: optimization and integration of novel soil gas probes with online trace gas detection

Abstract. Gas concentrations and isotopic signatures can unveil microbial metabolisms and their responses to environmental changes in soil. Currently, few methods measure in situ soil trace gases such as the products of nitrogen and carbon cycling or volatile organic compounds (VOCs) that constrain microbial biochemical processes like nitrification, methanogenesis, respiration, and microbial communication. Versatile trace gas sampling systems that integrate soil probes with sensitive trace gas analyzers could fill this gap with in situ soil gas measurements that resolve spatial (centimeters) and temporal (minutes) patterns. We developed a system that integrates new porous and hydrophobic sintered polytetrafluoroethylene (sPTFE) diffusive soil gas probes that non-disruptively collect soil gas samples with a transfer system to direct gas from multiple probes to one or more central gas analyzer(s) such as laser and mass spectrometers. Here, we demonstrate the feasibility and versatility of this automated multiprobe system for soil gas measurements of isotopic ratios of nitrous oxide (δ18O, δ15N, and the 15N site preference of N2O), methane, carbon dioxide (δ13C), and VOCs. First, we used an inert silica matrix to challenge probe measurements under controlled gas conditions. By changing and controlling system flow parameters, including the probe flow rate, we optimized recovery of representative soil gas samples while reducing sampling artifacts on subsurface concentrations. Second, we used this system to provide a real-time window into the impact of environmental manipulation of irrigation and soil redox conditions on in situ N2O and VOC concentrations. Moreover, to reveal the dynamics in the stable isotope ratios of N2O (i.e., 14N14N16O, 14N15N16O, 15N14N16O, and 14N14N18O), we developed a new high-precision laser spectrometer with a reduced sample volume demand. Our integrated system – a tunable infrared laser direct absorption spectrometry (TILDAS) in parallel with Vocus proton transfer reaction mass spectrometry (PTR-MS), in line with sPTFE soil gas probes – successfully quantified isotopic signatures for N2O, CO2, and VOCs in real time as responses to changes in the dry–wetting cycle and redox conditions. Broadening the collection of trace gases that can be monitored in the subsurface is critical for monitoring biogeochemical cycles, ecosystem health, and management practices at scales relevant to the soil system.

54 ENVIRONMENTAL SCIENCES↗

Trace Gases, Meteorological Parameters, and GPS data for TRACER-MAP

This dataset includes trace gas, meteorological, and GPS measurements made on Mobile Air Quality Laboratory 2 (MAQL2) for the TRACER-MAP sampling campaign. Trace gas measurements include nitric oxide (NO), nitrogen dioxide (NO2), reactive nitrogen compounds (NOy), ozone (O3), sulfur dioxide (SO2), and carbon monoxide (CO). All trace gases are in units of ppbv, excluding CO which is in ppmv. The dataset also includes the photolysis rate of NO2 (jNO2), latitude and longitude, wind speed (WS), wind direction (WD), ambient relative humidity (RH), ambient pressure (press), and ambient temperature (temp). Units for trace gases are in parts per billion (ppbv), latitude and longitude are in decimal degrees (dd), jNO2 is in per second (per sec), pressure is in millibar (mbar), relative humidity is in percent, the temperature is in degrees C, wind direction is in degrees, and wind speed is in meters per second. All data is 5 minutes averaged.

54 ENVIRONMENTAL SCIENCES↗

An algorithm for constrained maximization of the trace of a matrix

The 'trace' of a rectangular matrix is defined as the trace of a square matrix obtained by appending null rows (or columns) at the bottom (or right) end. The problem of maximizing the trace of a matrix, by permutations and mergers of rows and columns with constraints on the resulting size of the matrix, is of interest in comparison of maps and image-change detection. This correspondence presents an algorithm based on dynamic programming for efficient maximization of trace.

Ramapriyan, H. K.↗

Trace elements as quantitative probes of differentiation processes in planetary interiors

The characteristic trace element signature that each mineral in the source region imparts on the magma constitutes the conceptual basis for trace element modeling. It is shown that abundances of trace elements in extrusive igneous rocks may be used as petrological and geochemical probes of the source regions of the rocks if differentiation processes, partition coefficients, phase equilibria, and initial concentrations in the source region are known. Although compatible and incompatible trace elements are useful in modeling, the present review focuses primarily on examples involving the rare-earth elements.

Drake, M. J.↗

Analysis and composition of a model trace gaseous mixture for a spacecraft

Growing concern over trace gaseous contaminant accumulations in the enclosed atmospheres of long duration spacecraft missions has prompted the development of a trace contaminant data base on the basis of gas, lithium hydroxide, and charcoal samples collected on Space Shuttle missions. A model trace contaminant gas mixture containing 14 compounds was chosen with the aid of a FORTRAN program, on the strength of contaminant chemical and toxicological categories, frequency of occurrence, and worst-case concentration. The model gas mixture can be used to test trace contaminant control hardware for a manned spacecraft environment.

Schwartz, M. R.↗

A simulation model for the analysis of Space Station gas-phase trace contaminants

A simulation model for the analysis of gas-phase trace contaminants in the cabin air of the NASA Space Station Reference Configuration was developed at the NASA Langley Research Center. The model predicts changes in trace contaminant concentrations from both physical and chemical sources and sinks as a function of time. Simulations were performed in which values for relative humidity, temperature, radiation intensity, pressure, and initial species concentrations were constrained to values for these parameters measured and modeled in the continental tropics at the earth's surface. Species concentrations simulated using the model compared favorably with concentrations in the continental tropics which demonstrated that the chemical mechanism in the trace contaminant model approximates changes in atmospheric species concentrations. The sensitivity of initial species concentrations to producing changes in additional species concentrations was also assessed. Results from the model indicated that chemical reactions will be important in determining the composition of cabin air in the Space Station. It is anticipated that the trace contaminant model will be useful in assessing the impact of experiments and commercial operations on the composition of the cabin air in the Space Station.

Brewer, Dana A.↗