At least 91 records · Page 5

Normal incidence spectrophotometer using high density transmission grating technology and highly efficiency silicon photodiodes for absolute solar EUV irradiance measurements

New developments in transmission grating and photodiode technology now make it possible to realize spectrometers in the extreme ultraviolet (EUV) spectral region (wavelengths less than 1000 A) which are expected to be virtually constant in their diffraction and detector properties. Time dependent effects associated with reflection gratings are eliminated through the use of free standing transmission gratings. These gratings together with recently developed and highly stable EUV photodiodes have been utilized to construct a highly stable normal incidence spectrophotometer to monitor the variability and absolute intensity of the solar 304 A line. Owing to its low weight and compactness, such a spectrometer will be a valuable tool for providing absolute solar irradiance throughout the EUV. This novel instrument will also be useful for cross-calibrating other EUV flight instruments and will be flown on a series of Hitchhiker Shuttle Flights and on SOHO. A preliminary version of this instrument has been fabricated and characterized, and the results are described.

Ogawa, H. S.↗

A Single Chip VLSI Implementation of a QPSK/SQPSK Demodulator for a VSAT Receiver Station

This thesis presents a VLSI implementation of a QPSK/SQPSK demodulator. It is designed to be employed in a VSAT earth station that utilizes the FDMA/TDM link. A single chip architecture is used to enable this chip to be easily employed in the VSAT system. This demodulator contains lowpass filters, integrate and dump units, unique word detectors, a timing recovery unit, a phase recovery unit and a down conversion unit. The design stages start with a functional representation of the system by using the C programming language. Then it progresses into a register based representation using the VHDL language. The layout components are designed based on these VHDL models and simulated. Component generators are developed for the adder, multiplier, read-only memory and serial access memory in order to shorten the design time. These sub-components are then block routed to form the main components of the system. The main components are block routed to form the final demodulator.

Kwatra, S. C.↗

In-Situ Spectrometry of Neutrons

High energy charged particles of extra-galactic, galactic and solar origin collide with spacecraft structures in Earth orbit outside the atmosphere and in interplanetary travel beyond the Earth's magnetosphere. These primaries create a number of secondary particles inside the structures that can produce a significant ionizing radiation environment. This radiation is a threat to long term inhabitants or travelers for space missions and produces an increased risk of cancer and DNA damage. The primary high energy cosmic rays and trapped protons collide with common spacecraft materials such as aluminum and silicon and create secondary particles inside structures that are mostly protons and neutrons. Charged protons are readily detected and instruments are already in existence for this task. Neutrons are electrically neutral and therefore much more difficult to measure and detect. These neutrons are reported to contribute 30-60% of the dose inside space structures and cannot be ignored. Currently there is no compact, portable and real time neutron detector instrumentation available for use inside spacecraft or on planetary surfaces where astronauts will live and work. We propose to design and build a portable, low power and robust neutron spectrometer that will measure the neutron spectrum from 10 KeV to 500 MeV with at least 10% energy resolution in the various energy intervals. This instrument will monitor the existing neutron environment both inside spacecraft structures and on planetary surfaces to determine the safest living areas, warn of high fluxes associated with solar storms and assist the NSBRI Radiation Effects Team in making an accurate assessment of increased cancer risk and DNA damage to astronauts. The instrument uses a highly efficient proportional counter Helium 3 tube at the lowest energy intervals where .equivalent damage factors for tissue are the highest (10 KeV-2 MeV). The Helium 3 tube may be shielded with a cadmium absorber to eliminate the much less damaging, but more prevalent, thermal and epithermal neutrons and to make the structure of the spectrum more accurate in the 20 KeV-2 MeV range; or a pair of tubes, one shielded and one unshielded, can be combined so that the difference in their counts yields the thermal neutron contribution. The spectrometer also uses a 5mm lithium drifted bulk silicon solid state detector in the medium energy range of 2-20 Mev and two standard silicon surface barrier detectors separated by tens of millimeters behind a I cm thick polyethylene moderator in a stack or telescope arrangement for the high energy neutrons (>20 MeV). In the medium and high energy regions equivalent damage factors are lower but hits from one or a small number of neutrons may prove to be important. The silicon detector systems for medium and high energy neutrons will discriminate against charged particles by using a plastic cesium iodide scintillator of an appropriate geometry monitored by a silicon PIN photodiode.

Maurer, Richard H.↗

Broadband Wavefront Sensing for JWST Fine Phasing

An application of broadband image-based wavefront sensing is considered for JWST fine phasing. The wavefront sensing error is derived as a function of filter bandpass and then applied to determine the appropriate filter specifications for observatory fine-phasing. These specifications are defined by considering an optimization in the trade space consisting of detector integration time vs. filter bandpass subject to wavefront sensing error budget constraints.

Dean, Bruce↗

A detector for high frequency modulation in auroral particle fluxes

A high time resolution electron detector has been developed for use in sounding rocket studies of the aurora. The detector is used to look for particle bunching in the range 50 kHz-10 MHz. The design uses an electron multiplier and an onboard frequency spectrum analyzer. By using the onboard analyzer, the data can be transmitted back to ground on a single 93-kHz voltage-controlled oscillator. The detector covers the 50 kHz-10 MHz range six times per second and detects modulation on the order of a new percent of the total electron flux. Spectra are presented for a flight over an auroral arc.

Spiger, R. J.↗

Fabrication and Characterization of Superconducting NbN Nanowire Single Photon Detectors

We report on the fabrication and characterization of high-speed, single photon detectors using superconducting NbN nanowires at a wavelength of 1064 nm. A 15 by 15 micron detector with a detector efficiency of 40% has been measured. Due to kinetic inductance, the recovery time of such large area detectors is longer than that of smaller or single wire detectors. The recovery time of our detectors (50 ns) has been characterized by measuring the inter-arrival time statistics of our detector.

single proton detectors↗

Fabrication and Characterization of Superconducting NbN Nanowire Single Photon Detectors

This viewgraph presentation describes the fabrication of large area superconducting Niobium Nitride nanowire single photon detectors. The topics include: 1) Introduction and Motivation; 2) Operation of SNSPD Detectors; 3) NbTiN Deposition; 4) Fabrication Details; 5) Backside Coupled SNSPD; 6) Measurement Apparatus; 7) Electrical Response of a 15x15 micrometer SNSPD to 1064nm radiation; 8) Detector Efficiency vs Bias Current; 9) Interarrival Time Plot; 10) Detector Linearity; and 11) Conclusion.

single proton dectectors↗

Vacuum UV performance of silicon detectors

The sensitivity, time-varying response, and spatial sensitivity of four silicon detectors of vacuum UV were measured by passing a typical flux of 3 x 10 photons/s at the Lyman alpha line of 1215.7 A through an exit aperture of 0.55 mm x 0.8 mm. The detectors tested were: (1) a Fairchild FPM 200 silicon planar passivated photodiode with the window removed so that radiation could directly impinge on the center of the 1.0 mm square silicon chip, (2) a Fairchild FPM 100 silicon NPN planar passivated phototransistor, (3) the Hewlett-Packard 5082-4204 silicon planar PIN photodiode, and (4) the United Detector Technology PIN Spot/2 special sensitive silicon Schottky surface photodiode with the window removed.

Ohlhaber, R. L.↗

Gravity and Extreme Magnetism SMEX

Gas accreting ont,o black holes and neutron stars form a dynamic system generating X-rays with spectroscopic signatures and varying on time scales determined by the system. The radiation from various parts of these systems is surely polarized and compact sources have been calculated to give rise to net polarization from the unresolved sum of the radiation from the systems. Polarization has been looked to for some time as also bearing the imprint of strong gravity and providing complementary information that could resolve ambiguities between the physical models that can give rise to frequencies, time delays, and spectra. In the cases of both stellar black holes and supermassive black holes the net polarizations predicted for probable disk and corona models are less than 10 needed. This sensitivity can be achieved, even for sources as faint as 1 milliCrab, in the Gravity and Extreme Magnetism SMEX (GEMS) mission that uses foil mirrors and Time Projection Chamber detectors. Similarities have been pointed out between the timing and the spectral characteristics of low mass X-ray binaries and stellar black hole sources. Polarization measurements for these sources could play a role in determining the configuration of the disk and the neutron star.

Swank, Jean↗

Field-Programmable Gate Array Implementation of a Single Photon-Counting Receive Modem

We present a field-programmable gate array (FPGA) implementation of a single photon-counting receive modem for a pulse position modulated signal. The modem is compliant with the Consultative Committee for Space Data Systems (CCSDS) High Photon Efficiency (HPE) Optical Communications Coding and Synchronization standard and is capable of a maximum data rate of 267 Mbps. The system is designed on a commercial off-the-shelf FPGA platform and utilizes superconducting nanowire single photon counting detectors, analog to digital converters (ADC s) to sample the detectors, and two FPGAs. Symbol timing recovery, photon counting, convolutional deinterleaving, and codeword synchronization areis performed in the first FPGA. The second FPGA performs iterative decoding on each codeword of the serially concatenated pulse position modulated (SCPPM) signal. A digital filter is included to compensate for timing jitter of the detector, and the decoder throughput can be modified adjusted through reconfigurable parallelization. The decoder also implements a resource-efficient, algorithmic polynomial interleaver and deinterleaver. Both FPGAs can be reconfigured to switch between pulse position modulation (PPM)-16 and PPM-32 with code rates 1/3, 1/2, and 2/3. In this paper, we describe the receiver architecture and FPGA implementation of the timing recovery loop and SCPPM decoder, FPGA utilization for the different modes, and receive modem characterization test results.

Field-programmable Gate Array↗

The First Multichroic Polarimeter Array on the Atacama Cosmology Telescope: Characterization and Performance

The Atacama Cosmology Telescope Polarimeter (ACTPol) is a polarization sensitive receiver for the 6-meter Atacama Cosmology Telescope (ACT) and measures the small angular scale polarization anisotropies in the cosmic microwave background (CMB). The full focal plane is composed of three detector arrays, containing over 3000 transition edge sensors (TES detectors) in total. The first two detector arrays, observing at 146 gigahertz, were deployed in 2013 and 2014, respectively. The third and final array is composed of multichroic pixels sensitive to both 90 and 146 gigahertz and saw first light in February 2015. Fabricated at NIST, this dichroic array consists of 255 pixels, with a total of 1020 polarization sensitive bolometers and is coupled to the telescope with a monolithic array of broad-band silicon feedhorns. The detectors are read out using time-division SQUID multiplexing and cooled by a dilution refrigerator at 110 meter Kelvins. We present an overview of the assembly and characterization of this multichroic array in the lab, and the initial detector performance in Chile. The detector array has a TES detector electrical yield of 85 percent, a total array sensitivity of less than 10 microns Kelvin root mean square speed, and detector time constants and saturation powers suitable for ACT CMB observations.

Ho, S. P.↗

Radiation-Resistant Photon-Counting Detector Package Providing Sub-ps Stability for Laser Time Transfer in Space

We are reporting on a design, construction and performance of photon-counting detector packages based on silicon avalanche photodiodes. These photon-counting devices have been optimized for extremely high stability of their detection delay. The detectors have been designed for future applications in fundamental metrology and optical time transfer in space. The detectors have been qualified for operation in space missions. The exceptional radiation tolerance of the detection chip itself and of all critical components of a detector package has been verified in a series of experiments.

radiation hardness↗

Photodetector Array For Neural Network

Integrated circuit performs 1,024 threshold operations in parallel. Designed for use in postprocessing output of optical correlator in optoelectronic neural network. Overall function of device to put out digital signals indicative of location(s) of bright spot(s) on detector plane. Response time less than commercial charge-coupled-device (CCD) imaging detector operating at standard television frame rate.

Langenbacher, Harry↗

Algorithms for the determination of the time delays of the signal when using unequal detectors

In treating the recorded results from detectors at different locations in space, the analysis of the time delays of signals is crucial to locating the sources of detected radiation. Because the correlation method requires the manipulation of awkward matrices to evaluate its accuracy, a solution is outlined based on minimizing the sum of the squares of signal deviations, and the algorithms for evaluating the resulting error are presented.

Novak, B. L.↗

Dead-time effects in pulse-counting Digicon detectors

The Hubble Space Telescope's High Resolution Spectrograph employs two pulse-counting Digicon detectors to record UV spectra. At higher measured count rates, the intervals between photon arrivals become comparable to the response time of the electronics, so that not every pulse will be counted; this 'paired pulse' effect causes departures from linearity and must be corrected for during raw data reduction. Attention is given to two analytic equations that quantify the dead-time losses. The less attenuated spectra are noted to be severely distorted by these losses; a comparison with the undistorted low count rate data allows a detailed analysis to be made of the pulse-counting characteristics over five decades of input event rates. The present equations and calibration methods should be applicable to all kinds of multichannel pulse-counting detectors.

Ebbets, Dennis C.↗

High-Performance X-ray Detection in a New Analytical Electron Microscope

X-ray detection by energy-dispersive spectrometry in the analytical electron microscope (AEM) is often limited by low collected X-ray intensity (P), modest peak-to-background (P/B) ratios, and limitations on total counting time (tau) due to specimen drift and contamination. A new AFM has been designed with maximization of P. P/B, and tau as the primary considerations. Maximization of P has been accomplished by employing a field-emission electron gun, X-ray detectors with high collection angles, high-speed beam blanking to allow only one photon into the detector at a time, and simultaneous collection from two detectors. P/B has been maximized by reducing extraneous background signals generated at the specimen holder, the polepieces and the detector collimator. The maximum practical tau has been increased by reducing specimen contamination and employing electronic drift correction. Performance improvments have been measured using the NIST standard Cr thin film. The 0-3 steradian solid angle of X-ray collection is the highest value available. The beam blanking scheme for X-ray detection provides 3-4 times greater throughput of X-rays at high count rates into a recorded spectrum than normal systems employing pulse-pileup rejection circuits. Simultaneous X-ray collection from two detectors allows the highest X-ray intensity yet recorded to be collected from the NIST Cr thin film. The measured P/B of 6300 is the highest level recorded for an AEM. In addition to collected X-ray intensity (cps/nA) and P/B measured on the standard Cr film, the product of these can be used as a figure-of-merit to evaluate instruments. Estimated minimum mass fraction (MMF) for Cr measured on the standard NIST Cr thin film is also proposed as a figure-of-merit for comparing X-ray detection in AEMs. Determinations here of the MMF of Cr detectable show at least a threefold improvement over previous instruments.

Lyman, C. E.↗

Soft X-ray astronomy proportional counter electronics

The X-ray multiwire proportional counter is designed to measure cosmic X-ray fluxes at sounding rocket altitudes in the energy range of 0.1 to 10 keV. Four instruments will be launched in a Black Brant 4 rocket employing different combinations of detector windows and gas. The detector is constructed with two layers of twelve cells. A columnator is mounted on the face of one layer whose cells are wired together alternately to form two main detector sections. The electronics and gas regulation systems are mounted on the face of the second layer whose cells are wired together to form one anticoincidence detector section. Normally X-rays will have short ionization paths in only one of the main detector cells at a time and won't enter the anticoincidence detector cells. To distinguish between X-rays and charged particles, the instrument includes a coincidence discriminator, an anticoincidence discriminator, and a pulse rise time discriminator.

Gardner, W. R.↗