Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “thermal systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Renewable Thermal Energy Systems Designed for Industrial Process Solutions in Multiple Industries

Industrial decarbonization is a key area that must be accelerated, to foster the removal of fossil fuels from the provision of heat, especially at low temperatures less than 300 degrees C. This paper looks at the results of two case studies for understanding the economics and potential for renewable thermal energy systems (RTES), particularly in hybrid configurations to provide industrial process heat (IPH). The first case study looks at heat pumps for district heating, and the second, the use of linear Fresnel collectors (LFCs) coupled with phase change material (PCM) thermal energy storage (TES) for direct steam generation (DSG). Using district heat as an input for the heat pump, three cases were run harvesting energy from ambient water (5 degrees C), sewage water (20 degrees C), and a solar collector (35 degrees C). Accounting for elevated costs of infrastructure for each heat source, the levelized cost of heat (LCOH) of the first case study ranged from $4-$15 per million British Thermal Units (MMBTU). For the second case study modeling LFCs with PCM and TES, the results show that a LCOH of $9-$15 per MMBTU is possible, depending on the direct normal irradiance.

concentrated solar thermal↗

Renewable Thermal Energy Systems Designed for Industrial Process Solutions in Multiple Industries: Preprint

Industrial decarbonization is a key area that must be accelerated, to foster the removal of fossil fuels from the provision of heat, especially at low temperatures less than 300 degrees C. This paper looks at the results of two case studies for understanding the economics and potential for renewable thermal energy systems (RTES), particularly in hybrid configurations to provide industrial process heat (IPH). The first case study looks at heat pumps for district heating, and the second, the use of linear Fresnel collectors (LFCs) coupled with phase change material (PCM) thermal energy storage (TES) for direct steam generation (DSG). Using district heat as an input for the heat pump, three cases were run harvesting energy from ambient water (5 degrees C), sewage water (20 degrees C), and a solar collector (35 degrees C). Accounting for elevated costs of infrastructure for each heat source, the levelized cost of heat (LCOH) of the first case study ranged from $4-$10 per million British Thermal Units (MMBTU). For the second case study modeling LFCs with PCM and TES, the results show that a LCOH of $9-$15 per MMBTU is possible, depending on the direct normal irradiance.

concentrated solar thermal↗

Validation and Verification of TEDS Facility HYBRID Modeling

The HYBRID modeling repository is an in-house developed library of models for selected integrated energy systems (IES) modelling. HYBRID models have been developed since 2015 to describe the physical operation of tightly coupled thermal systems including power generators, thermal transport systems, thermal storage, thermal-to-electric conversion systems, and other thermal applications. Here, validation and verification (V&V) capabilities are demonstrated using the Thermal Energy Distribution System (TEDS) at INL. Building upon prior work, the TEDS model has been updated and verified so that it better represents the installed system configuration and the operating control system. The model control system was changed to allow replication of actual experimental procedures. Experimental operations focusing primarily on thermocline tank performance were devised and performed. Several anomalies were found in the operation data of the experiment facility. V&V activities calibrating a selected input parameter are demonstrated on a single component as well as with a single parameter within the thermocline. Calibrating is then demonstrated on multiple components and a multi-parameter metric for the entire system. The validation methodology is successfully applied to validate the model with experimental data. It is also used to confirm a hypothesis behind one of the anomalies in experimental performance.

25 ENERGY STORAGE↗

Property Measurements of the NaCl-PuCl 3 Molten Salt System

Thermal properties of several compositions of the binary NaCl-PuCl 3 salt were measured to confirm the eutectic composition and provide high quality data for use by MSR developers. The PuCl 3 was generated by reducing PuO 2 to plutonium metal in the presence of calcium metal and then chlorinating the metallic plutonium with NH 4 Cl. The resulting PuCl 3 was used to make seven binary NaCl-PuCl 3 compositions with between 59.9 mol % PuCl 3 (Salt 1) and 20.0 mol % PuCl 3 (Salt 7). The eutectic temperature was measured to be 457 ± 4 °C by onset determination in DSC analyses of the seven mixtures, which is consistent with the values in the literature. Additional transitions were observed at approximately 332 and 363 °C in analyses of the PuCl 3 -rich compositions (Salts 1-3) at about 376 and 439 °C in analyses the Na-rich compositions (Salts 4-7). The solid state heat capacity decreased with increasing PuCl 3 content. The liquid state heat capacity was measured for Salt 3 (37.4 mol % PuCl 3 ) and Salt 4 (38.3 mol % PuCl 3 ). A higher heat capacity was measured for Salt 4 and measurements with both salts showed a positive correlation with temperature between 520 and 730 °C. Cells fabricated from nickel and molybdenum for use in DSC measurements at high temperatures could not be adequately sealed because these materials are not sufficiently malleable, even after high temperature annealing. It is recommended that future development focus on corrosion-resistant materials that have mechanical and thermal properties similar to the commercially available gold cells, such as Pt-Rh (80–20) and pure platinum. Those materials are chemically inert, soft, and malleable like gold, but have melting temperatures higher than 1000 °C (Rakhtsaum, 2013). Use of the Pt-Rh alloy should be evaluated first based on superior machinability for making precision parts and its current use in commercial DSC high temperature crucibles. The commercial Pt-Rh cells are not hermetically sealable, but it is expected that cells made from thinner stock can be sealed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

System design and analysis of thermal power dispatch systems for boiling water reactors

Nuclear power plants are crucial to meeting net zero emission goals and achieving energy sustainability. Integrating these plants with clean energy technologies such as high-temperature steam electrolysis (HTSE) may improve the efficiency and economic competitiveness of these plants. Here, the current study investigates the design and operation of a thermal power dispatch (TPD) system for coupling boiling water reactors (BWRs) to HTSE plants. The TPD system extracts a portion of the steam from the reactor’s main steam line and transfers its thermal energy to an HTSE plant through a power transport loop. A TPD system for 5 % steam extraction has been designed and the system performance during steady and transient operations has been analyzed. The TPD system dispatched a total of 197 MW thermal energy to the HTSE plant under nominal design conditions. Saturated steam at 7.17 MPa from the BWR plant was condensed and subcooled to a temperature of 168 °C, while a mass flow rate of 91.1 kg/s of superheated steam was dispatched to the HTSE plant. Furthermore, the system performance during transient operation showed a continuous transition from the initial hot standby mode to the nominal power dispatch level. The transient simulation results emphasized the importance of investigating component level performance for the TPD system design. The current results will guide future works on the development of integrated energy systems for hydrogen production or process heat applications.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Dynamic Human-in-the-Loop Simulated Nuclear Power Plant Thermal Dispatch System Demonstration and Evaluation Study

An Idaho National Laboratory research team performed a human-in-the-loop study with two formerly licensed retired operators to evaluate thermal power dispatch operations supported by the modified GSE Systems GPWR plant simulator. Virtual representations of the analog control panels were presented on touch-screen bays configured to mimic the control room layout in the newly renovated Human Systems Simulation Laboratory. The operators performed 15 scenarios covering normal evolutions to transition the plant from full turbine operation to joint turbine and thermal power dispatch operations in addition to transient response scenarios induced with simulated faults to evaluate the impact of thermal power dispatch system on operator and plant responses. A prototype human-system interface (HSI) was developed and displayed in tandem with the virtual analog panels to support the operators executing the procedurally drive evolutions and transient responses. An interdisciplinary team of operations experts, nuclear engineers, and human factors experts observed the operators performing the scenarios to evaluate the operations. Only a preliminary analysis of the results has been performed. The full analysis will be shared in a milestone report scheduled for release at the end of September; however, some high-level conclusions were readily available. Two high level findings for the system design were captured in the study. The manual control supported by the HSI to transition from standard operations to thermal power dispatch operation imposed a considerable amount of workload on the operators due to tedious manual valve manipulations and system monitoring required to verify their intended effect. An additional operator would be required in the control room to support the daily evolution. Automatic control for the transition was deemed a requirement for plant adoption without imposing additional staffing costs. The second finding was the necessity for an automatic thermal power dispatch system trip isolation function linked to a turbine and reactor trip signal. The operators completed scenarios with automatic isolation functionality and manually required actuation of the thermal power dispatch system. The operator response was sufficiently slower in the manual trip condition, such that operators were unable to manually actuate key post trip safety functions an indicate a degraded control capability that should be avoided. With an automatic trip signal little to no impact of the thermal power dispatch system was identified on the primary plant response and therefore the system could be readily and safely adopted. Together these two findings represent the need to support the adoption of thermal power dispatch capability into existing operations by leveraging automation to augment any additional operator tasking required to control and monitor an additional system beyond existing operations.

99 GENERAL AND MISCELLANEOUS↗

The Internal Compound Parabolic Concentrator (ICPC): a Novel Low Cost Solar Thermal Collection System for Desalination Processes

The research team at UC Merced designed, prototyped, and tested (1) a novel low cost non-tracking solar thermal collector/concentrator called the Integrated Compound Parabolic Concentrator (ICPC) and (2) a low-cost phase-change thermal energy storage system. Together these technologies can significantly reduce the levelized cost of heat from solar thermal sources while also incorporating features of dispatchability and portability. The ICPC allows elevated temperature and efficiency in a low cost, non-tracking collector. The collector has demonstrated 60% ±4% solar to thermal modules efficiency at fluid outlet temperature of 120°C. The raw material cost of the collector system is reduced by utilizing low cost aluminum minichannels. The collector design is also amenable to economic mass production. A 200 tube, 10 kW prototype array was constructed and tested, yielding over 6 kWh/day on average at outlet fluid temperature exceeding 120°C.

14 SOLAR ENERGY↗

A Novel Approach to Investigate Thermal Protection Systems Materials

The Koo Research Group (KRG) at The University of Texas at Austin (UT) and KAI has specialized in “Ablation Research” for more than fifteen years. Recently, the group has developed several incredibly unique capabilities that can advance “Thermal Protection Systems (TPS) Materials Research & Development” using an integrated experimental and numerical approach. The paper aims to introduce the methodology KRG has developed to solve this challenging problem. It will discuss how the KRG develops “Process-Properties-Performance” relationships of novel TPS materials in a systematical approach using (a) processing and fabrication, (b) thermal characterization of properties, (c) aerothermal testing, (d) microstructures characterization and analysis, and (e) numerical modeling. Progress and challenges of this research will also be discussed.

Engineering↗

HYBRID Modeling Validation and Verification Status Matrix

The HYBRID modeling repository is a premier resource for integrated energy systems modeling. HYBRID models have been developed since 2015 to describe the physical operation of tightly coupled thermal systems including power generators, thermal transport systems, thermal storage, thermal-to-electric conversion systems, and other thermal applications. Due to the increased size of the repository, a concise summary matrix of available models is desired. This matrix will consolidate not only the list of available models but also indicate original information sources, publications that have model examples, and level of validation and verification that exists for the models. Validation and verification (V&V) levels begin from simplified algebraic relationship and advance to dynamic data validation. Moving forward, as new models are contributed to HYBRID, their V&V level will be included, updating this matrix.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

AMS Thermal Cooling System (Final Report)

The Alpha Magnetic Spectrometer (AMS) is a U.S. Department of Energy-sponsored particle physics experiment on the International Space Station (ISS). AMS is exploring some of the most fundamental questions in physics such as understanding dark matter, antimatter, the origin of cosmic rays and their characteristics as well as searching for new physics phenomena in the universe. It has recorded more than 200 billion cosmic rays since its launch in May 2011. Over time, anomalies associated with the dedicated cooling system of the AMS Silicon Tracker system were observed, leading to the discovery of progressive deterioration in the functioning of the cooling system's four redundant pumps. The Tracker is crucial to the scientific mission of AMS, as it is the only subdetector that can distinguish matter from antimatter. This report details the successful program of work for the installation of the Upgraded Tracker Thermal Pump System (UTTPS) on AMS. This program included: identifying the root cause of deterioration in the original pumps; design, production, testing, and integration of the new UTTPS cooling system; launch of the UTTPS to ISS; installation of the UTTPS in AMS across a series of four complex extra-vehicular activities (EVAs); and establishment of a dedicated Flight Simulator Laboratory to test the performance of the UTTPS under various thermal conditions. This program was critical to the success of the AMS experiment, and its successful completion will enable AMS to continue taking data through 2030.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optimal electric-distribution-grid planning considering the demand-side flexibility of thermal building systems for a test case in Singapore

The planning of district-scale electric grids, i.e., distribution grids, has traditionally relied on finding the most cost-effective design such that they are able to supply the peak loads in a district. With the advent of electric demand side flexibility (DSF), there is the opportunity to reshape peak loads such that the investment cost of the electric grid decreases in exchange for a minor increase in the operation cost. This paper formulates an optimal planning approach for the electric grid at the district scale, which incorporates the DSF from thermal building systems, e.g., heating ventilation and air-conditioning (HVAC) systems. The problem is formulated as a mixed-integer linear program (MILP) and aims at minimizing the investment cost for the grid along with the operation cost of the flexible loads. This is subjected to the fixed electricity demand and thermal comfort constraints of building occupants. To this end, linear models for the thermal comfort in the buildings and the power flow in electric grid are considered. The approach is tested on a district planning test case based in Singapore, where the results show up to 30.9 % reductions in investment cost and up to 3.7 % reduction in total annualized cost. Urban planning authorities, developers and utility companies can all benefit from the presented approach to make optimized investment decisions. For building operators, the results point to the need of adopting their control systems for DSF.

Troitzsch, Sebastian↗

A transmissive concentrator photovoltaic module with cells directly cooled by silicone oil for solar cogeneration systems

Hybrid concentrator photovoltaic-thermal systems can cogenerate electricity and heat by beam-splitting incoming concentrated light onto photovoltaic cells and a thermal receiver to increase total conversion efficiency and potentially reduce system cost. To demonstrate this, we have designed and prototyped a transmissive spectrum-splitting concentrator photovoltaic module that maximizes solar energy conversion by utilizing the entire solar spectrum. Visible light is collected using infrared-transmissive triple-junction photovoltaic cells to achieve an in-band module efficiency of 43.3% for light of wavelength λ < 873 nm, while 44.2% of out-of-band light with λ > 873 nm is transmitted through for collection by a thermal receiver. During testing on a dual-axis tracked parabolic concentrator dish at up to 166 suns, cell temperatures were maintained at 119 °C or below via a novel active cooling method. This cooling system strictly flows silicone oil directly across both sides of the cells, without inhibiting optical transmission, as verified through experimentation and simulation. The module was validated outdoors for 572 sun·hrs, and achieved a maximum thermal receiver temperature of 180 °C. 86.1% of incident solar power is collected at 166 suns average concentration collectively among the electrical, cooling, and thermal receiver subsystems. The remaining 13.9% is lost to mirror reflectivity, dish shadowing, receiver reflection, and thermal losses. The ability to directly cool the cells with an inert silicone oil offers the potential for reduced system cost relative to previous transmissive hybrid concentrator photovoltaic-thermal systems, including microfluidic-cooled designs. This solar cogeneration capability is valuable in a wide range of commercial and industrial applications.

14 SOLAR ENERGY↗

Comparison Between Pin-by-Pin Subchannel and System Level Thermal Hydraulic Results for High Burnup Loss-of-Coolant Applications

This milestone report summarizes recent work to investigate higher fidelity modeling and simulation practices for large-break loss-of-coolant accident (LBLOCA) analysis in high-burnup pressurized water reactor (PWR) cores. Because of current industry interest in extending fuel cycle lengths ranging from 18 to 24-months, the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program has been investigating the susceptibility of high-burnup core designs to fuel fragmentation, release, and dispersal (FFRD) during accident conditions such as LBLOCA. This work has prioritized developing and demonstrating a methodology for calculating core-wide susceptibility to FFRD and addressing uncertainties identified in the analysis and the US Nuclear Regulatory Commission (NRC) Research Information Letter on FFRD. Part of this investigation seeks to quantify differences between system-level thermal hydraulic behavior and higher fidelity subchannel modeling methods to identify potential safety concerns or opportunities to minimize FFRD susceptibility. To this end, the NEAMS subchannel code, CTF, is being used, along with the NRC system analysis code TRACE, for analysis of LBLOCA in a core containing high-burnup fuel. This project includes two thrusts: (1) improving on the existing TRACE model for a 4-loop PWR for LBLOCA so that the model is higher fidelity and consistent with current USNRC best practices, and (2) using CTF to perform pin-resolved modeling of the core region of the reflood phase of a LBLOCA in a high-burnup PWR.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Renewable Thermal Energy Systems: Systemic Challenges and Transformational Policies (Report 2)

Two important challenges for RTES are the need for significant further innovation and deployment, particularly in the United States. In the face of continued success of other renewable energy technologies, such as solar photovoltaics (PV) and land-based wind energy for electricity, it is worthwhile to evaluate the current state of select RTES technologies in the context of technology innovation systems and energy transitions. This report marks a departure from the existing body of research we are aware of and have contributed to relating to RTES applications for industrial process heat in the United States. Our objectives for this report are fourfold: 1) Begin considering the challenges of RTES deployment in the United States through application of socio-technical and transitions frameworks; 2) Begin applying the theory of RTES as configurational technology innovation systems in the United States and for industrial process heat specifically; 3) Review RTES innovation, policies, and market formation activities in the contexts of Objectives 1 and 2; 4) Identify future paths for RTES research. Ultimately, the challenges associated with scaling the deployment of RTES in the United States are related to the need to develop a well-functioning innovation system that can overcome resistance from a highly stable socio-technical regime within a shrinking window of time to address the climate crisis, U.S. industrial competitiveness, and volatile energy commodity price shocks. Current efforts toward scaling for RTES applications in industry and buildings emphasize the need for further cost reductions, but not for interventions that support actors and their interactions and that increase the legitimacy of the technologies. As a result, there are significant opportunities to analyze the social contexts of RTES that can then be used to inform the design of effective, transformational policy portfolios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Smart Manufacturing Pathways for Industrial Decarbonization and Thermal Process Intensification

Rapid decarbonization is fast becoming the primary environmental and sustainability initiative for many economic sectors. Industry consumes more than 30 % of all primary energy in the United States and accounts for nearly 25 % of all greenhouse gas (GHG) emissions. More than 70 % of energy consumed by the industrial sector is related to thermal processes, which are also the largest contributors of carbon emissions, overwhelmingly due to the combustion of fossil fuels. Thermal process intensification (TPI) seeks to dramatically improve the energy performance of thermal systems through technology pillars focusing on alternative energy sources and processes, supplemental technologies, and waste heat management. The impacts of TPI have significant overlap with the goals of industrial decarbonization (ID) that seeks to phase out all GHG emissions from industrial activities. Emerging supplemental technologies such as smart manufacturing (SM) and the industrial internet of things (IoT) enable significant opportunities for the optimization of manufacturing processes. Combining strategies for TPI and ID with SM and IoT can open and enhance existing opportunities for saving time and energy via approaches such as tighter control of temperature zones, better adjustment of thermal systems for variations in production levels and feedstock properties, and increased process throughput. Data collected by smart processes will also enable new advanced solutions such as digital twins and machine learning algorithms to further improve thermal system savings. Herein, this paper examines the individual pathways of TPI, ID, and SM and how the combination of all three can accelerate energy and GHG reductions.

42 ENGINEERING↗

Thermal Modeling and Simulation of the Packed-bed Thermal Energy Storage Combined with INL Thermal Energy Distribution System

Dynamic Energy Transport and Integration Lab (DETAIL) at Idaho National Laboratory is to support experimental demonstration and validation research on Nuclear-Renewable Hybrid Energy System [1]. The Thermal Energy Distribution System (TEDS) is a thermal-hydraulic flow loop in DETAIL with its own dedicated control system to support the integration of co-located multiple experimental systems, where a packed-bed thermal energy storage (TES) is installed as a thermal buffer and storage unit. Among various TES options, the packed-bed TES is adopted in TEDS because it offers a low-cost single-tank thermal storage option compared to the traditional two-tank TES. However, since the TES tank is filled with granular fillers having different thermophysical properties from those of TES tank wall, there is a potential thermo-mechanical issue to be carefully addressed like thermal ratcheting which may pose a significant design concern for the packed-bed TES tank. Thermal ratcheting is a thermomechanical process caused by the repeated rearrangement of granular filler inside a TES tank during continuous thermal cycling operation of the packed-bed TES system. If the thermally induced stress exceeds the yield strength of a TES tank wall, catastrophic consequences may happen like rupture of the TES tank. Thus, it is important to understand the phenomenon to ensure the robust operation of the packed-bed TES tank. Given that thermal ratcheting is caused by complex interaction of thermal transport in the porous bed and solid mechanics, the accurate prediction of transient thermal behavior of the packed-bed TES tank, which is the focus of this paper, is critical to the reliable thermal ratcheting analysis. This paper discusses the numerical modeling, simulation, and validation studies that are ongoing at INL to investigate the transient thermal behavior of the packed-bed TES. Of particular concern is the transient thermal process occurring in the packed-bed TES unit that is operated in conjunction with the INL TEDS. The main goal of this research is three-fold: (i) provide preliminary insights into the transient thermal behavior of the TEDS TES tank, (ii) support the thermal measurement and validation plan for TEDS experiment, and (iii) provide transient thermal boundary conditions to support the reliable thermal ratcheting analysis of the TEDS TES tank. For the transient thermal modeling and analysis, a CFD model was developed, and the validity of the modeling approach was examined via comparing the numerical simulation results with the experimental data obtained from various design characteristics of packed-bed TES tanks. Then, the present modeling method was applied for the transient thermal analysis of the TEDS TES tank, and the results are discussed along with the potential improvement of data acquisition strategy for the future TEDS experiments for more precise validation study.

25 ENERGY STORAGE↗

GIS-Based Graphical User Interface Tools for Analyzing Solar Thermal Desalination Systems & High-Potential Implementation

This project developed a user-friendly, open-source, software that enables a comparative evaluation of solar thermal desalination technology options and employs geospatial data layers to identify regions of high-potential for solar thermal desalination. This was accomplished by integrating solar models with desalination models and enhancing their utility by providing GIS-based data inputs. The developed Solar Energy Desalination Analysis Tool (SEDAT) enables techno-economical evaluation of desalination technologies and selection of regions with the highest potential for using solar energy to power desalination plants. It simplifies the planning, design, and valuation of solar thermal and solar hybrid desalination systems in the U.S. and worldwide. SEDAT uses Dash for integrating various layers of large volumes of GIS data with Python-based models of solar energy generation and desalination technologies. It derives time-series of energy generation and water production, with details of plant performance and suggestions for improving the solar-desalination coupling. It is a one of-a-kind tool of analysis representing a definitive advancement in the state-of-the-art. Of solar desalination modeling This report summarizes the various phases of the tool’s development, and presents examples of the results.

14 SOLAR ENERGY↗

Thermal storage system with coupled tanks

Methods and apparatus are disclosed for high-efficiency thermal storage with a fluid-filled “battery” tank positioned within a fluid-filled “reservoir” tank. Fluid loops couple the tanks to a heat pump and a building. The heat pump can charge the battery tank or deliver thermal energy (cold or heat) to a building, using the reservoir tank or ambient air as a thermal energy source. The battery tank can discharge energy to the building jointly with the heat pump or, at periods of peak electricity usage, with the heat pump switched off. Operating modes allow significant savings in electricity usage and mitigate the “duck curve.” Low duty cycle usage of the reservoir enables efficient underground thermal storage with less digging than conventional geothermal technologies. Additional efficiency is achieved with phase change materials installed inside a tank or in a tank wall, providing temperature regulation. Control methods are disclosed.

15 GEOTHERMAL ENERGY↗