Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “thermal sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Development of Compact, Modular Lunar Heat Flow Probes

Geothermal heat flow measurements are a high priority for the future lunar geophysical network missions recommended by the latest Decadal Survey and previously the International Lunar Network. Because the lander for such a mission will be relatively small, the heat flow instrumentation must be a low-mass and low-power system. The instrument needs to measure both thermal gradient and thermal conductivity of the regolith penetrated. It also needs to be capable of excavating a deep enough hole (approx. 3 m) to avoid the effect of potential long-term changes of the surface thermal environment. The recently developed pneumatic excavation system can largely meet the low-power, low-mass, and the depth requirements. The system utilizes a stem which winds out of a pneumatically driven reel and pushes its conical tip into the regolith. Simultaneously, gas jets, emitted from the cone tip, loosen and blow away the soil. The thermal sensors consist of resistance temperature detectors (RTDs) embedded on the stem and an insitu thermal conductivity probe attached to the cone tip. The thermal conductivity probe consists of a short 'needle' (2.4-mm diam. and 15- to 20-mm length) that contains a platinum RTD wrapped in a coil of heater wire. During a deployment, when the penetrating cone reaches a desired depth, it stops blowing gas, and the stem pushes the needle into the yet-to-be excavated, undisturbed bottom soil. Then, it begins heating and monitors the temperature. Thermal conductivity of the soil can determined from the rate of temperature increase with time. When the measurement is complete, the system resumes excavation until it reaches the next targeted depth.

Lunar↗

Multi-Dimensional Sensors and Sensing Systems

A universal microelectromechanical (MEMS) nano-sensor platform having a substrate and conductive layer deposited in a pattern on the surface to make several devices at the same time, a patterned insulation layer, wherein the insulation layer is configured to expose one or more portions of the conductive layer, and one or more functionalization layers deposited on the exposed portions of the conductive layer to make multiple sensing capability on a single MEMS fabricated device. The functionalization layers are adapted to provide one or more transducer sensor classes selected from the group consisting of: radiant, electrochemical, electronic, mechanical, magnetic, and thermal sensors for chemical and physical variables and producing more than one type of sensor for one or more significant parameters that need to be monitored.

Stetter, Joseph R.↗

Development of X-Ray Microcalorimeter Imaging Spectrometers for the X-Ray Surveyor Mission Concept

Four astrophysics missions are currently being studied by NASA as candidate large missions to be chosen inthe 2020 astrophysics decadal survey.1 One of these missions is the X-Ray Surveyor (XRS), and possibleconfigurations of this mission are currently under study by a science and technology definition team (STDT). Oneof the key instruments under study is an X-ray microcalorimeter, and the requirements for such an instrument arecurrently under discussion. In this paper we review some different detector options that exist for this instrument,and discuss what array formats might be possible. We have developed one design option that utilizes eithertransition-edge sensor (TES) or magnetically coupled calorimeters (MCC) in pixel array-sizes approaching 100kilo-pixels. To reduce the number of sensors read out to a plausible scale, we have assumed detector geometriesin which a thermal sensor such a TES or MCC can read out a sub-array of 20-25 individual 1 pixels. In thispaper we describe the development status of these detectors, and also discuss the different options that exist forreading out the very large number of pixels.

multiplexing↗

Surface temperature measurements using a thin film thermal array

A thin film device was designed and fabricated to measure surface temperatures. An array of eight integrated thermal sensors are mounted on a 0.002 inch (0.05 mm) Kapton film and multiplexed to obtain an area thermal measurement. The device was tested on a flat plate airfoil and demonstrated a temperature variation of 0.55 C maximum and 0.05 C minimum compared to embedded thermocouples. Future improvements are also discussed.

Dillon-Townes, L. A.↗

Evaluation of the prototype dual-axis wall attitude measurement sensor

A prototype dual-axis electrolytic tilt sensor package for angular position measurements was built and evaluated in a laboratory environment. The objective was to investigate the use of this package for making wind tunnel wall attitude measurements for the National Transonic Facility (NTF) at NASA Langley Research Center (LaRC). The instrumentation may replace an existing, more costly, and less rugged servo accelerometer package (angle-of-attack package) currently in use. The dual-axis electrolytic tilt sensor package contains two commercial electrolytic tilt sensors thermally insulated with NTF foam, all housed within a stainless steel package. The package is actively heated and maintained at 160 F using foil heating elements. The laboratory evaluation consisted of a series of tests to characterize the linearity, repeatability, cross-axis interaction, lead wire effect, step response, thermal time constant, and rectification errors. Tests revealed that the total RMS errors for the x-axis sensor is 0.084 degree, and 0.182 degree for the y-axis sensor. The RMS errors are greater than the 0.01 degree specification required for NTF wall attitude measurements. It is therefore not a viable replacement for the angle-of-attack package in the NTF application. However, with some physical modifications, it can be used as an inexpensive 5-degree range dual-axis inclinometer with overall accuracy approaching 0.01 degree under less harsh environments. Also, the data obtained from the tests can be valuable for wind tunnel applications of most types of electrolytic tilt sensors.

Wong, Douglas T.↗

User requirements and user acceptance of current and next-generation satellite mission and sensor complement, oriented toward the monitoring of water resources

Principal water resources users were surveyed to determine the applicability of remotely sensed data to their present and future requirements. Analysis of responses was used to assess the levels of adequacy of LANDSAT 1 and 2 in fulfilling hydrological functions, and to derive systems specifications for future water resources-oriented remote sensing satellite systems. The analysis indicates that water resources applications for all but the very large users require: (1) resolutions on the order of 15 meters, (2) a number of radiometric levels of the same order as currently used in LANDSAT 1 (64), (3) a number of spectral bands not in excess of those used in LANDSAT 1, and (4) a repetition frequency on the order of 2 weeks. The users had little feel for the value of new sensors (thermal IR, passive and active microwaves). What is needed in this area is to achieve specific demonstrations of the utility of these sensors and submit the results to the users to evince their judgement.

Castruccio, P. A.↗

Thermal coupling apparatus for electroexplosive devices

This paper describes the equipment for nondestructive testing of electroexplosive devices using a thermal coupling technique. The technique utilizes a self-balancing bridge to apply a nominal amount of power to the bridge wire of the device. The bridge wire behaving as a thermal sensor detects heat flow into the device when heat is preferentially directed down the center of the explosive column toward the bridge wire. Thermal equilibrium is upset and the change in power from the self-balancing bridge is measured directly in watts. Faults such as omissions, incorrect materials, contamination, and so on, can be detected by observing the rate of heat flow to the bridge wire. The response is indicative of the thermal resistance and diffusivity of the system. The paper also presents data on electroexplosive devices loaded with inert and explosive materials.

Menichelli, V. J.↗

Pneumatic Proboscis Heat-Flow Probe

Heat flow is a fundamental property of a planet, and provides significant constraints on the abundance of radiogenic isotopes, the thermal evolution and differentiation history, and the mechanical properties of the lithosphere. Heat-flow measurements are also essential in achieving at least four of the goals set out by the National Research Council for future lunar exploration. The heat-flow probe therefore directly addresses the goal of the Lunar Geophysical Network, which is to understand the interior structure and composition of the Moon. A key challenge for heat flow measurement is to install thermal sensors to the depths approximately equal to 3 m that are not influenced by the diurnal, annual, and longer-term fluctuations of the surface thermal environment. In addition, once deployed, the heat flow probe should cause little disturbance to the thermal regime of the surrounding regolith. A heat-flow probe system was developed that has two novel features: (1) it utilizes a pneumatic (gas) approach, excavates a hole by lofting the lunar soil out of the hole, and (2) deploys the heat flow probe, which utilizes a coiled up tape as a thermal probe to reach greater than 3-meter depth. The system is a game-changer for small lunar landers as it exhibits extremely low mass, volume, and simple deployment. The pneumatic system takes advantage of the helium gas used for pressurizing liquid propellant of the lander. Normally, helium is vented once the lander is on the surface, but it can be utilized for powering pneumatic systems. Should sufficient helium not be available, a simple gas delivery system may be taken specifically for the heat flow probe. Either way, the pneumatic heat flow probe system would be much lighter than other systems that entirely rely on the electrical power of the lander.

Zacny, Kris↗

Thermal Properties of Microstrain Gauges Used for Protection of Lithium-Ion Cells of Different Designs

The purpose of this innovation is to use microstrain gauges to monitor minute changes in temperature along with material properties of the metal cans and pouches used in the construction of lithium-ion cells. The sensitivity of the microstrain gauges to extremely small changes in temperatures internal to the cells makes them a valuable asset in controlling the hazards in lithium-ion cells. The test program on lithium-ion cells included various cell configurations, including the pouch type configurations. The thermal properties of microstrain gauges have been found to contribute significantly as safety monitors in lithium-ion cells that are designed even with hard metal cases. Although the metal cans do not undergo changes in material property, even under worst-case unsafe conditions, the small changes in thermal properties observed during charge and discharge of the cell provide an observable change in resistance of the strain gauge. Under abusive or unsafe conditions, the change in the resistance is large. This large change is observed as a significant change in slope, and this can be used to prevent cells from going into a thermal runaway condition. For flexible metal cans or pouch-type lithium-ion cells, combinations of changes in material properties along with thermal changes can be used as an indication for the initiation of an unsafe condition. Lithium-ion cells have a very high energy density, no memory effect, and almost 100-percent efficiency of charge and discharge. However, due to the presence of a flammable electrolyte, along with the very high energy density and the capability of releasing oxygen from the cathode, these cells can go into a hazardous condition of venting, fire, and thermal runaway. Commercial lithium-ion cells have current and voltage monitoring devices that are used to control the charge and discharge of the batteries. Some lithium-ion cells have internal protective devices, but when used in multi-cell configurations, these protective devices either do not protect or are themselves a hazard to the cell due to their limitations. These devices do not help in cases where the cells develop high impedance that suddenly causes them to go into a thermal runaway condition. Temperature monitoring typically helps with tracking the performance of a battery. But normal thermistors or thermal sensors do not provide the accuracy needed for this and cannot track a change in internal cell temperatures until it is too late to stop a thermal runaway.

Jeevarajan, Judith↗

Developing Multilayer Thin Film Strain Sensors With High Thermal Stability

A multilayer thin film strain sensor for large temperature range use is under development using a reactively-sputtered process. The sensor is capable of being fabricated in fine line widths utilizing the sacrificial-layer lift-off process that is used for micro-fabricated noble-metal sensors. Tantalum nitride films were optimized using reactive sputtering with an unbalanced magnetron source. A first approximation model of multilayer resistance and temperature coefficient of resistance was used to set the film thicknesses in the multilayer film sensor. Two multifunctional sensors were fabricated using multilayered films of tantalum nitride and palladium chromium, and tested for low temperature resistivity, TCR and strain response. The low temperature coefficient of resistance of the films will result in improved stability in thin film sensors for low to high temperature use.

Wrbanek, John D.↗

Applications of HCMM satellite data

The thermal properties of Lake Ontario as they relate to water equality, lake hydrology and energy exchange were investigated as well as the urban heat island problem in selected areas adjacent to the lake. The HCMM thermal sensor was fully calibrated for several underflight data. Actual surface water temperature maps were generated for all of Lake Ontario using the calibration procedure developed. Major water quality changes associated with the thermal bar as located by HCMM thermal data were observed from satellite and aerial data and verified by ground truth.

Source record↗

Assessing High Resolution Thermal Monitoring of Complex Intertidal Environments From Space: the Case of ECOSTRESS at Rias Baixas, NW Iberia

Currently, thermal sensors on satellites and other orbital platforms with high spatial resolution designed to monitor the oceans are often insufficient to assess the surface temperature of small bodies of water or within the coastal boundary layer. As the accuracy and sensitivity of remote sensing satellites improve, the demand for more accurate and up-to-date basic data sets for calibration increases. The quality of the thermal data collected by ECOSTRESS on the International Space Station allows the characterization of thermal stress levels in coastal ecosystems with a high spatial resolution of 70 m and a return time from hours to 5 days. This study focused on the calibration of ECOSTRESS estimates with in situ surface temperature data from sensors installed at 3 cm depth in the sediment on the intertidal muddy sandflats of three of the Rías Baixas in Galicia, NW Iberian Peninsula, from 2019 to 2021. A final number of 45 ECOSTRESS temperature images were analyzed. From these, 20% contained substantial georeferencing errors which had to be corrected manually with GIS software tools. We applied the Fourier's law of Heat Conduction to derive surface estimates from loggers sub-surface measurements that could be directly compared with ECOSTRESS data. Overall, a good calibration which explained more than 80% of ECOSTRESS temperature estimates for the whole dataset was obtained, but with an intrinsic cold bias around 1.39 °C. When temperatures at a depth of 3 cm were used, the linear fit became worse and the negative bias increased to 1.49 °C. Closer inspection revealed that night measurements were responsible for this larger deviation, as ECOSTRESS estimates became much colder compared to within sediment measurements because of the combined effect of the instrument intrinsic bias and nocturnal surface cooling. The best calibration was obtained when surface estimates were calculated just for the nighttime, as the cold bias decreased to 0.93 °C. More importantly, during hot daytime conditions in emersion above 20 °C, ECOSTRESS data matched surface temperature estimates, probably because of a better performance of ECOSTRESS algorithm at dry surfaces with lower emissivity. Thus, during the most ecologically relevant periods when high temperatures could drive thermal stress in many commercially-important bivalve species, ECOSTRESS provides accurate surface estimates that can be used to derive sub surface temperatures at the depths at which the different burrowing organisms live. We thus conclude that this instrument constitutes an important global tool to examine thermal stress at an unprecedented spatial scale for complex sea-land boundary systems.

ECOSTRESS↗

Ground-based measurement of surface temperature and thermal emissivity

Motorized cable systems for transporting infrared thermometers have been used successfully during several international field campaigns. Systems may be configured with as many as four thermal sensors up to 9 m above the surface, and traverse a 30 m transect. Ground and canopy temperatures are important for solving the surface energy balance. The spatial variability of surface temperature is often great, so that averaged point measurements result in highly inaccurate areal estimates. The cable systems are ideal for quantifying both temporal and spatial variabilities. Thermal emissivity is also necessary for deriving the absolute physical temperature, and measurements may be made with a portable measuring box.

Owe, M.↗

Thermal Design and Analysis for the Cryogenic MIDAS Experiment

The Materials In Devices As Superconductors (MIDAS) spaceflight experiment is a NASA payload which launched in September 1996 on the Shuttle, and was transferred to the Mir Space Station for several months of operation. MIDAS was developed and built at NASA Langley Research Center (LaRC). The primary objective of the experiment was to determine the effects of microgravity and spaceflight on the electrical properties of high-temperature superconductive (HTS) materials. The thermal challenge on MIDAS was to maintain the superconductive specimens at or below 80 K for the entire operation of the experiment, including all ground testing and 90 days of spaceflight operation. Cooling was provided by a small tactical cryocooler. The superconductive specimens and the coldfinger of the cryocooler were mounted in a vacuum chamber, with vacuum levels maintained by an ion pump. The entire experiment was mounted for operation in a stowage locker inside Mir, with the only heat dissipation capability provided by a cooling fan exhausting to the habitable compartment. The thermal environment on Mir can potentially vary over the range 5 to 40 C; this was the range used in testing, and this wide range adds to the difficulty in managing the power dissipated from the experiment's active components. Many issues in the thermal design are discussed, including: thermal isolation methods for the cryogenic samples; design for cooling to cryogenic temperatures; cryogenic epoxy bonds; management of ambient temperature components self-heating; and fan cooling of the enclosed locker. Results of the design are also considered, including the thermal gradients across the HTS samples and cryogenic thermal strap, electronics and thermal sensor cryogenic performance, and differences between ground and flight performance. Modeling was performed in both SINDA-85 and MSC/PATRAN (with direct geometry import from the CAD design tool Pro/Engineer). Advantages of both types of models are discussed. Correlation of several models to ground testing and flight data (where available) is presented. Both SINDA and PATRAN models predicted the actual thermal performance of the experiment well, even without post-flight correlation adjustments of the models.

Amundsen, Ruth McElroy↗

Response of GAS payload (G345 and G347) temperatures to various orbiter flight attitudes

At the beginning of the Get-Away Special (GAS) flight program, the GAS Project flew a Flight Verification Payload on STS-3 to make measurements of the vibrations, acoustic and magnetic environments of the canister, and to obtain thermal profiles of internal and external components of the GAS system. These data were used to verify pre-flight thermal models of the GAS system and results have been published in a GSFC Technical Note, X-732-83-8 (Butler, 1983). On somewhat later flights of the Orbiter, STS-7 and STS-8, the Naval Research Laboratory and the Goddard Space Flight Center jointly developed and flew a GAS payload whose primary objective was to evaluate the performance of ultraviolet-sensitive (Schumann) photographic emulsions in the Orbiter environment, including pre-flight integration, on-orbit exposure to the ambient environment of the Orbiter bay and post-flight conditions before removal of the experiment from the vehicle. These emulsions, used in spectrographs to record solar radiations with wavelengths between 100 A and 2000 A, have low gelatin content and no protective gelatin overcoating in order to maximize their UV sensitivity. Consequently, they are extremely sensitive to environmental conditions. Furthermore, they are exposed directly to space during the observations because any intervening protective window or lense would completely absorb the radiations to be studied. which was prepared at the Naval Research Laboratory under the direction of Robert Kreplin (Kreplin et al., 1984 a) also included two thermal sensors, whose output was recorded once an hour with a precision of 0.7O C. The experiment operated nominally on both missions and provided important data confirming that W - sensitive emulsions could tolerate integration and flight on the Shuttle with relatively little deterioration. The results of these studies have already been reported (Kreplin et al, 1984 b). The temperature measurements also were recorded successfully and are the basis for this paper. They are a useful complement to the thermal observations made on STS-3 and provide additional insight into the reaction of a payload to typical thermal environments that GAS experiments are subject to. Our GAS experiment and the circumstances of its flights were particularly useful in terms of modeling the thermal response of the GAS canister and our instrument. The Orbiter was held (except for interruptions for star tracker alignment, satellite deployments, etc., in specific attitudes for sufficiently long periods of time that the thermal response of the instrument to each attitude was well measured. Two types of GAS canister end cap, one, the insulated end cap and the other a silverized teflon covered end-cap, were used on the two flights so that a direct comparison of the thermal performance of the two types was obtained. This report is an attempt to compare these observations with a simple thermal model of the instrument in the GAS canister in order to assess whether such simple models can be useful to experimenters in predicting the thermal response of their payloads.

Werner M. Neuper↗

Instrumentation research at MSFC

Inflight hydrogen detection by mass spectrometer, thermal sensor, uhf telemetry, and addressable time division data system

SENSOR↗

Temperature or pressure controller

Silicon chip thermal sensor coupled into a solid state power source controls temperature or pressure in combustion research. The silicon chip sensing element is embedded in a ceramic support for insulation, and connected to a high resistance bridge which operates the solid state power amplifiers.

Gillett, J. D.↗