Evaluation of thermal loading on a methane injector at high pressure and temperature

Experimental and numerical analyses are conducted to determine the surface temperature on a methane fuel injector used to produce a high enthalpy test stream for a combustion-fed subscale wind tunnel facility. It was found that the ratio of the methane fuel injection velocity to the air stream velocity is a significant factor in the production of high injector surface temperatures which lead to rapid deterioration of the fuel injector structure. The numerical code utilized for the computational analysis was found to be representative of the experimentally measured data since the experimental trends were reproduced by the numerical simulation. The quantitative accuracy of the numerical predictions could not be assessed from the data gathered because of the difficulty of making a noninterfering injector surface temperature measurement. The numerical code can be used for parametric evaluation of combustor parameters and thus will serve as an important tool in the design of such fuel injector systems.

Harvin, Stephen F.↗

Free vibration of thermally loaded panels including initial imperfections and post-buckling effects

A combined theoretical and experimental approach is developed to consider the small amplitude free vibration characteristics of fully clamped panels under the influence of uniform heating. Included in this study are the effects of higher modes, in-plane boundary elasticity, initial imperfections, and post-buckling. Comparisons between theory and experiment reveal excellent agreement.

Murphy, K. D.↗

Bolted Double-Lap Composite Joints Under Mechanical and Thermal Loading

This study concerns the determination of the contact stresses and contact region around bolt holes and the bolt load distribution in single- and double-lap joints of composite laminates with arbitrarily located bolts under general mechanical loading conditions and uniform temperature change. The unknown contact stress distribution and contact region between the bolt and laminates and the interaction among the bolts require the bolt load distribution, as well as the contact stresses, to be as part of the solution. The present method is based on the complex potential theory and the variational formulation in order to account for bolt stiffness, bolt-hole clearance, and finite geometry of the composite laminates.

Kradinov, V.↗

The Effect of Asymmetric Mechanical and Thermal Loading on Membrane Wrinkling

Large, tensioned membranes are being considered for future gossamer spacecraft systems. Examples include sunshields, solar sails, and membrane optics. In many. cases a relatively flat membrane with minimal wrinkling is desired. Developing methods to predict and measure membrane wrinkling is important to the future development of gossamer spacecraft. Numerical and experimental data are presented for a 0.5 m square, tensioned membrane. The membrane is subjected to symmetric and asymmetric mechanical loading. Data are also presented for a symmetrically loaded membrane subjected to spot heating in the center. The numerical model shows good agreement with the experiment for wrinkle angle data. There is. also reasonable agreement for the wrinkled area for both isothermal and elevated temperature tests.

Blandino, Joseph R.↗

Effect of Cyclic Thermal Loads on Fatigue Reliability in Polymer Matrix Composites

Technological solutions that will ensure the economic viability and environmental compatibility of a future High Speed Civil Transport plane are currently being sought. Lighter structural materials for both airframe primary structures and engine structure components are being investigated. We believe that such objectives can be achieved through the use of high-temperature composites as well as other conventional, lighter weight alloys. One of the prime issues for these structural components is assured long-term behavior with a specified reliability. An investigation was conducted to describe a computational simulation methodology for predicting fatigue life, reliability, and probabilistic long-term behavior of polymer matrix composites. A unified time-, stress-, and load-dependent Multi- Factor Interaction Equation (MFIE) model developed at the NASA Lewis Research Center was used to simulate the long-term behavior of polymer matrix composites.

Chamis, Christos C.↗

Effect of Mechanical and Thermal Loading Histories on Residual Properties of SiCf/SiC Ceramic Matrix Composites

Silicon Carbide based Ceramic Matrix Composites (CMCs) are attractive materials for use in high-temperature structural applications in the aerospace and nuclear industries. Under high stresses and temperatures, creep degradation is the dominant damage mechanism in CMCs. Consequently, chemical vapor infiltration (CVI) SiCf/SiC ceramic matrix composites (CMC) incorporating SylramicTM-iBN SiC fibers coated with boron nitride (BN) interphase and CVI-SiC matrix were tested to examine creep behavior in air at a range of elevated temperatures of (2200 - 2700 F). Samples that survived creep tests were evaluated via RT fast fracture tensile tests to determine residual properties, with the use of acoustic emission (AE) to assess stress dependent damage initiation and progression. Microscopy of regions within the gage section of the tested specimens was performed. Observed material degradation mechanisms are discussed.

creep↗

Application of Thermal Loads to a Numerical Model

A detailed aerothermal model requires the application of the heat flux profile over all exposed aerodynamic surfaces. These loads are created using both engineering methods (e.g., FORTRAN codes implementing correlations) and CFD simulations (e.g., solutions to Navier-Stokes equations). The goal is to define the spatial and temporal dependency of the heat flux upon the model.

cfd↗

Addressing energy storage needs at lower cost via on-site thermal energy storage in buildings

Cost-effective energy storage is a critical enabler for the large-scale deployment of renewable electricity. Significant resources have been directed toward developing cost-effective energy storage, with research and development efforts dominated by work on lithium ion (Li-ion) battery technology. Though Li-ion batteries have many attractive qualities, it is not clear whether they can provide an affordable levelized cost of storage (LCOS) for certain applications, such as buildings. Buildings consume most of the world's electricity, and as much as 50% of their consumption goes toward meeting thermal loads. Thermal energy storage (TES) can provide a cost-effective alternative to Li-ion batteries for buildings; however, two questions remain to be answered. First, how much of total building energy storage requirements can be met via thermal storage for building loads? Second, can the LCOS for TES be favorable compared with Li-ion batteries? In this perspective, using the United States as a case study, we show that the total requirement for TES in buildings is in the range of ~1200–4500 electrical GW h, depending on the fraction of solar versus wind in the generation mix. Furthermore, we show that with at least 25% wind generation, all of the storage needed by buildings to support the grid can be met by TES. We also introduce a framework to calculate LCOS for on-site TES in buildings to enable a direct comparison with electrical storage technologies such as Li-ion batteries. This is not trivial, because the input energy type for TES (electricity) differs from the output energy type (thermal energy), and the efficiency can depend on ambient conditions. Our LCOS analysis shows that in many situations, TES can be more cost-effective for buildings than Li-ion batteries. We conclude our perspective by discussing future research and development opportunities that can significantly advance the deployment of TES for buildings to help enable a renewable electricity-dependent grid.

25 ENERGY STORAGE↗

Comparison of Thermal Management Approaches for Integrated Traction Drives in Electric Vehicles

The continuous push to increase power densities of electric vehicle (EV) traction drive systems necessitates combining electric motor and power electronics into one unit. A single, compact traction drive unit with fewer interconnecting components also facilitates fast, automated assembly of electric vehicles, driving production costs down and enabling wider adoption of EVs. There are a number of challenges associated with the integration of power electronics with the electric machine, including thermal management of the combined traction drive system. However, one important benefit of integration from the thermal management system perspective is the potential for using a single fluid loop instead of two separate cooling systems for the electric machine and the power electronics/inverter. This paper reviews several integration approaches and, employing finite element analysis (FEA), compares thermal management solutions for the combined electric machine and power electronics systems. Namely, three different scenarios are modeled: (1) independent component (motor and power electronics) cooling, which is compared to the combined cooling system approach for (2) radially and (3) axially integrated power electronics modules into the motor enclosure. Temperature distributions for selected thermal loads and thermal resistances from the key heat-generating components to the cooling fluid are compared for each scenario.

47 OTHER INSTRUMENTATION↗

Nonlinear analysis of laminated fibrous composites

A computerized analysis of the nonlinear behavior of fibrous composite laminates including axial loading, thermal loading, temperature dependent properties, and edge effects is presented. Ramberg-Osgood approximations are used to represent lamina stress-strain behavior and percent retention curves are employed to model the variation of properties with temperature. Balanced, symmetric laminates comprised of either boron/epoxy, graphite/epoxy, or borsic-aluminum are analyzed using a quasi-three-dimensional finite element analysis. Results are presented for the interlaminar stress distributions in cross-ply, angle-ply, and more complex laminates. Nonlinear stress-strain curves for a variety of composite laminates in tension and compression are obtained and compared to other existing theories and experimental results.

Renieri, G. D.↗

Design Environment for Multifidelity and Multidisciplinary Components

One of the greatest challenges when developing propulsion systems is predicting the interacting effects between the fluid loads, thermal loads, and structural deflection. The interactions between technical disciplines often are not fully analyzed, and the analysis in one discipline often uses a simplified representation of other disciplines as an input or boundary condition. For example, the fluid forces in an engine generate static and dynamic rotor deflection, but the forces themselves are dependent on the rotor position and its orbit. It is important to consider the interaction between the physical phenomena where the outcome of each analysis is heavily dependent on the inputs (e.g., changes in flow due to deflection, changes in deflection due to fluid forces). A rigid design process also lacks the flexibility to employ multiple levels of fidelity in the analysis of each of the components. This project developed and validated an innovative design environment that has the flexibility to simultaneously analyze multiple disciplines and multiple components with multiple levels of model fidelity. Using NASA's open-source multidisciplinary design analysis and optimization (OpenMDAO) framework, this multifaceted system will provide substantially superior capabilities to current design tools.

Platt, Michael↗

Plastic set of smooth large radii of curvature thermal conductance specimens at light loads

Thermal contact conductance test data at high vacuum were obtained from two Armco iron specimens having smooth, large radii of curvature, convex, one-half wave length surfaces. The data are compared with calculations based on two macroscopic elastic deformation theories and an empirical expression. Major disagreement with the theories and fair agreement with the empirical expression resulted. Plastic deformation of all the contacting surfaces was verified from surface analyzer statistics. These results indicate that the theoretical assumption of macroscopic elastic deformation is inadequate for accurate prediction of heat transfer with light loads for Armco iron specimens similar to those used in this investigation.

Mckinzie, D. J., Jr.↗

Plastic set of smooth large radii of curvature thermal conductance specimens at light loads.

Thermal contact conductance test data at high vacuum were obtained from two Armco iron specimens having smooth, large radii of curvature, convex, one-half wave length surfaces. The data are compared with calculations based on two macroscopic elastic deformation theories and an empirical expression. Major disagreement with the theories and fair agreement with the empirical expression resulted. Plastic deformation of all the contacting surfaces was verified from surface analyzer statistics. These results indicate that the theoretical assumption of macroscopic elastic deformation is inadequate for accurate prediction of heat transfer with light loads for Armco iron specimens similar to those used in this investigation.

Mckinzie, D. J., Jr.↗

Solar thermal heating and cooling. A bibliography with abstracts

This bibliographic series cites and abstracts the literature and technical papers on the heating and cooling of buildings with solar thermal energy. Over 650 citations are arranged in the following categories: space heating and cooling systems; space heating and cooling models; building energy conservation; architectural considerations, thermal load computations; thermal load measurements, domestic hot water, solar and atmospheric radiation, swimming pools; and economics.

Arenson, M.↗

ComStock Measure Documentation: Ideal Thermal Air Loads

This study provides hypothetical thermal heating and cooling loads for ComStock models representing the U.S. commercial building stock. This measure scenario removes all HVAC models from the baseline ComStock building model and instead uses "ideal air" to meet loads. "Ideal air" can be thought of as an HVAC unit that mixes air at the zone exhaust condition with the specified amount of outdoor air, and then adds or removes heat and moisture at 100% efficiency to produce a supply air stream at the specified conditions. The resulting ideal thermal loads are represented under the "district" fuel type for both heating and cooling and can be found in both annual and timeseries results in the ComStock public dataset. This measure scenario does not represent any real technology or improvement, but rather, serves as a resource for thermal heating and cooling loads for buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗