Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “thermal heat”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

The development of an advanced generic solar dynamic heat receiver thermal model

An advanced generic solar dynamic heat receiver thermal model under development which can analyze both orbital transient and orbital average conditions is discussed. This model can be used to study advanced receiver concepts, evaluate receiver concepts under development, analyze receiver thermal characteristics under various operational conditions, and evaluate solar dynamic system thermal performances in various orbit conditions. The model and the basic considerations that led to its creation are described, and results based on a set of baseline orbit, configuration, and operational conditions are presented to demonstrate the working of the receiver model.

Wu, Y. C.↗

Cryogenic thermal diode heat pipes

The development of spiral artery cryogenic thermal diode heat pipes was continued. Ethane was the working fluid and stainless steel the heat pipe material in all cases. The major tasks included: (1) building a liquid blockage (blocking orifice) thermal diode suitable for the HEPP space flight experiment; (2) building a liquid trap thermal diode engineering model; (3) retesting the original liquid blockage engineering model, and (4) investigating the startup dynamics of artery cryogenic thermal diodes. An experimental investigation was also conducted into the wetting characteristics of ethane/stainless steel systems using a specially constructed chamber that permitted in situ observations.

Alario, J.↗

Characterization of thermally heat-treated polyacrylonitrile carbon fibers

This study investigates the graphitization process of polyacrylonitrile (PAN) carbon fibers by subjecting commercial fibers to thermal heat treatment at temperatures ranging from 1400 to 2100 °C in 100 °C increments, using either argon or nitrogen gas atmospheres. Changes in crystallinity, surface morphology, and lattice parameters were analyzed for two commercial carbon fibers using X-ray diffraction, scanning electron microscopy, and Raman spectroscopy. Results indicated minimal changes in surface morphology with increasing heat-treatment temperature; however, crystallinity significantly increased. Crystallinity changes were more strongly dependent on temperature rather than gas atmosphere or fiber type. At intermediate heat-treatment temperatures (1600–1800 °C), fibers treated in argon showed a slight preference for graphitization. The highest level of graphitization was measured at 2100 °C. Crystallite size increased as the intensity ratio of the D1 to G Raman peaks increased, reaching a peak around ~1800 °C, after which the ratio started to decrease. This behavior aligns with Ferrari's three-stage model of carbon crystallization and is consistent with both the Marie-Mering degree of graphitization and Brubaker's Integrated Absolute Differential models, all of which describe the transformation from an amorphous to a more graphitic structure. At the higher heat-treatment temperatures, the changes between atmospheres and fiber types were measured to converge to similar levels of graphitization. In conclusion, this study evaluates the progressive change in commercial grade carbon fibers when heat-treated.

Characterization↗

Thermal Vacuum/Balance Test Results of Swift BAT with Loop Heat Pipe Thermal System

The Swift Burst Alert Telescope (BAT) Detector Array is thermally well coupled to eight constant conductance heat pipes (CCHPs) embedded in the Detector Array Plate PAP), and two loop heat pipes (LHPs) transport heat from the CCHPs to a radiator. The CCHPs have ammonia as the working fluid and the LHPs have propylene as the working fluid. Precision heater controllers, which have adjustable set points in flight, are used to control the LHP compensation chamber and Detector Array xA1 ASIC temperatures. The radiator has AZ-Tek's AZW-LA-II low solar absorptance white paint as the thermal coating, and is located on the anti-sun side of the spacecraft. A thermal balance (T/B) test on the BAT was successfully completed. It validated that the thermal design satisfies the temperature requirements of the BAT in the flight thermal environments. Instrument level and observatory level thermal vacuum (TN) cycling tests of the BAT Detector Array by using the LHP thermal system were successfully completed. This paper presents the results of the T/B test and T N cycling tests.

Choi, Michael K.↗

Response Of Ceramic Insulation To Aerothermodynamic Heating

Thermal conductivities determined from engineering model used to predict accurately thermal responses of multicomponent insulation on spacecraft. Types of insulation studied include such composite parts as alumina-enhanced thermal barrier backed by low-density fibrous refractory material. Internal responses of various types of multicomponent insulation to aerothermodynamic heating calculated with help of computer program that implements engineering model for thermal conductivity. Transfer of heat by internal radiation plays major role in responses of fibrous materials at high temperatures and incorporated into model and program. Used in future spacecraft and exposed during reentry and aerobraking maneuvers in outer atmosphere to environments even harsher than that of Space Shuttle.

Stewart, David A.↗

Thermally Anisotropic Composites for Heat Redirection and Thermal Management in Building Envelopes

In building envelope systems, thermal management is important from energy conservation and thermal comfort perspectives, and is typically done via insulation, thermal mass, solar control and shading, etc. Thermal anisotropy is commonly utilized in electronics for heat dissipation. This article investigates the feasibility of utilizing thermally anisotropic composites (TACs) to reduce unwanted heat gains and losses through the building envelope by redirecting the heat transfer to or from appropriate heat sinks and sources.Numerical simulations of building envelope components using COMSOL Multiphysics and whole building simulations using EnergyPlus (E+) were performed to estimate the energy savings potential of TACs used in external walls of residential buildings. Application of TACs was compared with baseline walls with cavity insulation as well as with and without exterior continuous insulation (CI). The COMSOL simulations indicated 75% or higher reductions in heat gains when using a TAC coupled with a heat sink compared to an exterior CI case. In terms of energy savings in a hot climate, E+ models estimated cooling energy savings of 19% with a "TAC + heat sink" compared to a baseline wall with only cavity insulation. Further, a small-scale test sample with a TAC-heat sink system was built and tested in a multi-transducer heat flow meter (HFM). The heat sink was a copper tube circulating cold water. The experiments verified the re-direction of heat to a sink and significant reduction in heat transfer through the test specimen. The experiments showed that the heat redirection only occurred in the presence of both thermal anisotropy and water circulation; if either element was missing, the system behaved like a traditional envelope component.

Biswas, Kaushik↗

Thermal control - Heat buses will operate like a public utility

Active thermal control for the NASA space station concept requires long life heat rejection, highly versatile thermal transport, and efficient system integration. By a significant margin, the heat radiator will be the largest and most exposed portion of the space station thermal system. Transport requirements encompass the collection and movement of thermal energy from the space station's heat sources to the radiator heat sink at required temperature levels. In a decentralized thermal system, each space station module would collect and reject all of the waste heat generated, thereby requiring no module interconnections. This scheme does not, however, allow waste heat from one module to be used by another. In a centralized system, heat must be transported across module boundaries. A high capacity monogroove heat pipe has been developed to simplify space radiators design and operation.

Ellis, W. E.↗

Artemis I Space Launch System Base Heat Shield Thermal Protection System Performance

The Space Launch System (SLS) Core Stage base heat shield experienced the highest external heating environments on the entire launch vehicle during Artemis I ascent flight. This result was consistent with design predictions. The base heat shield experiences P50 cork combustion dynamics at low altitudes, plume-induced recirculation at moderate altitudes and then in-space base flow physics out to Main Engine Cut-Off (MECO). The base heat shield thermal protection system (TPS) is composed of a P50 cork ablator which is bonded to a substrate. The heat shield protects the gimbal actuation system, RS-25 turbomachinery systems and other aft section sensitive components during ascent. This paper estimates the base heat shield TPS performance from Artemis I using flight data from the NASA Langley Research Center’s Scientifically Calibrated In-Flight Imagery (SCIFLI) Airborne Multispectral Imager (SAMI), development flight instrumentation (DFI) and other TPS recession flight measurements. Predictions from computational and ground test-derived engineering ablation models and observations are also applied. Since no base heat shield substrate thermocouple data were obtained for Artemis I, an estimate of the TPS performance data is derived here. This data assesses thermal margin of the SLS Core Stage base heat shield and best informs the Artemis II Crewed mission to the moon.

aerothermodynamics↗

Development of Passive Fuel Cell Thermal Management Heat Exchanger

The NASA Glenn Research Center is developing advanced passive thermal management technology to reduce the mass and improve the reliability of space fuel cell systems for the NASA Exploration program. The passive thermal management system relies on heat conduction within highly thermally conductive cooling plates to move the heat from the central portion of the cell stack out to the edges of the fuel cell stack. Using the passive approach eliminates the need for a coolant pump and other cooling loop components within the fuel cell system which reduces mass and improves overall system reliability. Previous development demonstrated the performance of suitable highly thermally conductive cooling plates that could conduct the heat, provide a sufficiently uniform temperature heat sink for each cell of the fuel cell stack, and be substantially lighter than the conventional thermal management approach. Tests were run with different materials to evaluate the design approach to a heat exchanger that could interface with the edges of the passive cooling plates. Measurements were made during fuel cell operation to determine the temperature of individual cooling plates and also to determine the temperature uniformity from one cooling plate to another.

Burke, Kenneth A.↗

Heat Pipe Thermal Conditioning Panel

The technology involved in designing and fabricating a heat pipe thermal conditioning panel to satisfy a broad range of thermal control system requirements on NASA spacecraft is discussed. The design specifications were developed for a 30 by 30 inch heat pipe panel. The fundamental constraint was a maximum of 15 gradient from source to sink at 300 watts input and a flux density of 2 watts per square inch. The results of the performance tests conducted on the panel are analyzed.

Saaski, E. W.↗

An Innovative Very Low Thermal Power Waste Heat Recovery System for Thermal Control of Deep Space Missions: A Thermal Flask in Space

Future missions to deep space, such as those to the outer planets (Jupiter, Saturn, etc.), which would rely on solar photovoltaic power, would need extremely large solar arrays to produce sufficient power for their operations because solar intensity is so low at those locations. Hence any additional power that would be needed for thermal control is extremely limited. Previous deep space missions like Juno (to Jupiter) required almost 200 W of electrical power for thermal control. This is prohibitively large for many future mission concepts, and leads to them needing very large solar arrays. For Saturn, where the solar flux is 1/4th the flux at Jupiter, this would entail an extremely large increase in the solar array size to accommodate the need for thermal survival power, which would be prohibitively large in size and mass, and very expensive. Hence there is a need to come up with a thermal architecture and design options that would not need such prohibitively large thermal power levels. One solution relies on harvesting the pre-existing waste heat from all the heat dissipation that would be present from operation of electronics, instruments, etc. for their own functionality. For example, for a generic Saturn mission, the various electronics would already dissipate about 200 Watts of heat that is simply "thrown away" to space from the spacecraft surfaces. The amount of thermal power that would be required for the safe thermal control of components within the spacecraft in deep space would be roughly of this magnitude for this class of spacecraft. So it makes good sense to try to harvest the waste heat and employ it to maintain the temperatures of all the components within their allowable limits. In particular, propulsion systems typically need to be kept above their freezing limits, around room temperature (15 C). Electronics needs to be kept typically above -40 C and batteries above -20 C. The next question becomes how to harvest this waste heat and direct it to the components that would need it for their survival. The proposed system utilizes a mechanically pumped, single phase fluid loop to pick up the waste heat from components attached to this loop's tubing and then directed to a thermal flask that has tubing attached to it. The thermal flask is cylindrically shaped and contains essentially all systems and components in the spacecraft within it, with the exception of the solar array, antennae, thrusters and various apertures of instruments, etc. to allow them an unobstructed view of space. Waste heat from the heat-dissipating components warms up the fluid and is carried to the flask surface and deposited on it via the fluid loop's flow. The entire flask is covered with Multi-Layered Insulation (MLI) to minimize the heat loss from the flask and allow it to remain warm. Hence the flask essentially creates a thermal environment within which the spacecraft components reside. The temperature of the components within the flask is then essentially the same as the temperature of the flask. This approach could be a very enabling feature for deep space missions. This paper describes the approach utilized for this thermal architecture, along with its mechanical and implementation aspects. Additionally it will compare and contrast this approach with the more conventional solutions utilized earlier.

Bhandari, Pradeep↗

Internal heating and thermal constraints on the mantle

Numerical simulations have been carried out to study the average temperature and thermal structure of an internally heated mantle. It is found that in an incompressible mantle the hottest parts are localized in regions of slow flow in the middle and upper mantle, whereas in a compressible mantle they occur over laterally extensive regions near the core-mantle boundary (CMB). For chondritic concentrations of heat-producing elements (hpe's), the average thermal conductivity in the mantle must be high to avoid heating the core, and the temperature of the CMB is low to avoid large-scale melting. The mantle may have been extensively molten in the Archaean.

Leitch, A. M.↗

Entry heating and thermal protection

The book provides a documentation of progress in entry heating and thermal protection as related to two very challenging and very dissimilar applications, viz., the Jovian atmospheric probe as a key element of the Galileo mission, and the Space Shuttle. The Jovian atmospheric probe presents what might be the ultimate challenge in terms of the severity of entry. Success of the Galileo probe depends upon a design based on computational analysis largely unverified by experiment. Topics of interest include methods for predicting off-stagnation-point flowfields for planetary entry probes, modeling of radiative heating in base region of Jovian entry probe, gas heating with pressure gradients for the Space Shuttle, external tank laminar and rarefied aeroheating, and a study of the aerothermal entry environment for the Galileo probe.

Olstad, W. B.↗

NCSU Industrial Assessment Center

Renewable energy technologies are becoming more attractive and gaining more attention as the world becomes increasingly aware of the negative impacts of global warming and greenhouse gas (GHG) emissions. Two such emerging technologies are geothermal heat pumps (GHP) and solar thermal heating which can be used for heating and cooling of buildings. GHP systems are a well-studied technology that have been proven to be more efficient than traditional air-source heat pumps for space conditioning of buildings. Solar thermal heating has become more common as a way to heat domestic hot water (DHW) in homes, but the two technologies are not often combined. This study presents the findings of combining an open-loop GHP with 100 ft2 of flat plate solar thermal panels and a 5,655-gallon sensible water storage tank for space heating and DHW heating needs of a residential home in Bozeman, MT, USA. The goal of this system was to use energy from the solar panels and storage tank first to decrease pumping energy from the GHP well. The open loop system was designed to be a backup system to the solar thermal panels and sensible storage tank. An actual home was modeled to determine potential energy and cost savings of such a system compared to a traditional propane boiler. Then, a case study was performed on the installed system from January to June 2021. Results obtained from April 2nd to June 5th, 2021 indicated that the combination system supplied all necessary heat, and that heat was supplied from the thermal storage tank 55% of the time. This represents a savings of 330 kWh of energy and $36 compared to operating just the open loop geothermal system. From April 2nd to June 5th the combination system consumed a total of 2,510 kWh of energy and cost $274 to operate. Based on data obtained, there is significant potential for energy savings compared to a propane boiler, however only small potential for cost savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Temperature and density structure of the corona and inner solar wind

A combined theoretical and observational approach is used to construct models of the inner corona applicable to quiet open-field regions and coronal holes. These models, extending from the top of the transition region at about 1.003 solar radii out to 3 solar radii, are calculated by employing parameters that describe the coronal geometry and heating. Thermal conductivity, heating, radiative losses, and solar-wind convection are included in the full energy-balance equation, which is integrated to obtain density and temperature models; the unknown heating term is parameterized in terms of the mechanical flux incident at the base and the characteristic scale height for the dissipation of this flux; and boundary conditions at the base are fixed by EUV-derived models of the transition region. Two representative models, one for a coronal hole and one for a quiet region, are examined in detail as illustrative examples of the technique used. It is noted that the models obtained predict most of the pertinent observations reasonably well but significantly overestimate the radio emission at 80 and 160 MHz and significantly underestimate the intensity of the Fe XV line at 284 A, especially in coronal holes.

Kopp, R. A.↗