Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “testing standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

AGC 4 Graphite Specimen Postirradiation Characterization Plan

This characterization plan describes the thermal, physical, and mechanical measurement techniques that will be used to characterize graphite samples being tested in the fourth Advanced Graphite Creep experiment (AGC-4). Instruments, fixtures, and methods are currently in place for both pre and postirradiation material property measurements of bulk density, thermal diffusivity, coefficient of thermal expansion, elastic modulus, and electrical resistivity. Postirradiation testing procedures used to characterize the samples are described and discussed in the plan. Where they exist, American Society for Testing and Materials (ASTM) International testing standards will apply to the tests. Any departure from ASTM International testing standards or the approved laboratory procedures are documented within this characterization plan. Deviations that occur during testing will be documented in data reports.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Stress Testing the Standard Model of Particle Physics at the Large Hadron Collider

Final technical report for the DOE grant "Stress Testing the Standard Model of Particle Physics at the Large Hadron Collider", awarded to Prof. Aram Apyan at Brandeis University. The work focused on the ATLAS experiment at LHC. During the award period the group worked on ATLAS physics analyses, all-silicon Inner Tracker (ITk) detector upgrade, and reconstruction and calibration.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Investigation of nonlinear mechanical behavior of two superfine-grained graphites with DIC assisted disc splitting test

Using standardized uniaxial tensile test specimens is not practical due to the limited volumes in irradiation capsules, molten salt degradation facilities, or oxidation apparatus. The ASTM International Standard Test Method for Tensile Strength Estimate by Disc Compression of Manufactured Graphite (ASTM D8289) was developed to provide a convenient way for estimating tensile strength. Unlike the traditional uniaxial tensile test in ASTM C749 (International Standard Test Method for Tensile Stress–Strain of Carbon and Graphite), which uses dog-bone shaped specimens larger than 12.95 mm × 120.65 mm, the ASTM D8289 standard uses smaller discs with diameters of 6–12.7 mm. A digital image correlation (DIC) system, which uses a full-field noncontact surface displacement measurement technique, was applied along with the ASTM D8289 disc splitting test on IG-110 samples and compared with previous measurements from Mersen 2114 samples. Results confirmed that the DIC technique can measure the surface displacement/strain on these small (Ø6 mm × 3 mm) graphite specimens with good repeatability. However, Mersen 2114 and IG-110 samples exhibited strain discrepancies when DIC measurements were compared with analytical and finite element simulation values. The loading history and strain results also indicated different mechanical behaviors between Mersen 2114 and IG-110, particularly the nonlinear behavior of the IG-110 samples. Good agreement was observed by comparing the splitting tensile strengths of two superfine-grained grades with results from other work. The specimen size effect is discussed when comparing the splitting tensile strength with corresponding uniaxial tensile strength of these two graphite grades.

Lin, Lianshan [ORNL] (ORCID:0000000203399219)↗

Non-Intrusive Load Monitoring Assessment: Literature Review and Laboratory Protocol

Unlike sub-metering, which requires that individual loads are equipped with their own meters, nonintrusive load monitors (NILM) use algorithms to discern the individual loads from a single metering point. Although a number of these technologies are now commercially available to utilities and homeowners, with several more to become available in the coming years, it is not yet understood how accurately these technologies can disaggregate a home’s electrical load. Pacific Northwest National Laboratory (PNNL) and its partners at the Northwest Energy Efficiency Alliance (NEEA) have identified and acquired six of these technologies and will be testing them in the PNNL Lab Homes as well as the owner-occupied Residential Test Bed operated by NEEA. As a result of this testing, PNNL and NEEA will evaluate the selected NILMs against a repeatable test protocol so that their accuracy can be compared across NILM technologies. In the field deployment in the NEEA Test Bed Homes, PNNL and NEEA will evaluate the real-world accuracy of the NILMs responding to dynamic loads. To evaluate the accuracy of NILM technologies regardless of their intended application, a standardized test protocol is required that applies representative loads and establishes consistent metrics against which the NILM can be evaluated and compared. To establish this standardized test protocol, a literature review was conducted to identify any test protocols or standardized testing approaches currently in use. The literature review indicated that no consistent conventions were currently in place for measuring the accuracy of these technologies. Consequently, PNNL developed a testing protocol and metrics to provide the basis for quantifying and analyzing the accuracy of commercially available NILM technologies. This report discusses the results of the literature review and the proposed test protocol and metrics in more detail.

NILM↗

Mechanical behavior analysis using small-size graphite disc compression testing with digital image correlation methods

The ASTM International Standard Test Method for Tensile Stress-Strain of Carbon and Graphite (ASTM C749) requires dog-bone shaped specimens. Unfortunately, specimen sizes required in ASTM C749 are much too large for irradiation within a test reactor and are incompatible with irradiation capsule volumes, molten salt degradation facilities, or oxidation apparatus. The ASTM International Standard Test Method for Tensile Strength Estimate by Disc Compression of Manufactured Graphite (ASTM D8289) was developed as an alternative that provides a means for testing tensile properties using smaller specimens when geometric constraints are present. However, the important stress–strain relation throughout the test loading history that could be recorded using ASTM C749 is lost by using ASTM D8289 because of the difficulties involved with using traditional strain gauges or extensometers on such a small specimen. In this work, a digital image correlation (DIC) method, which uses a full-field noncontact surface displacement measurement technique, was applied along with the ASTM D8289 splitting tensile test on eight small samples of graphite grade Mersen 2114 to track their deformation during compressive loading. Initial results showed that the DIC technique can measure the surface displacement/strain on these small (Ø6 × 3 mm) graphite specimens with high accuracy and good repeatability, indicating that the DIC technique, combined with the small-disc splitting tensile test in ASTM D8289, can capture the strain evolution in the test. In conclusion, further comparison of measured strains with analytical and numerical simulation results provides additional understanding of the mechanical behaviour of this nuclear graphite material in complex stress states.

36 MATERIALS SCIENCE↗

Binary pseudo-random array standards for calibration of 3D optical surface profilers used for metrology with aspheric x-ray optics

High-accuracy surface metrology is vitally important in manufacturing ultra-high-quality free-form mirrors designed to manipulate x-ray light with nanometer-scale wavelengths. The current and potential capabilities of x˗ray mirror manufacturing are limited by inherent imperfections of the integrated metrology tools. Metrology tools are currently calibrated with super-polished flat test-standard/reference mirrors. This is acceptable for fabrication of slightly curved x-ray optics. However, for even moderately curved aspherical x-ray mirrors the flat-reference calibration is not sufficiently accurate. For micro-stitching interferometry developed for surface measurements with curved x-ray mirrors, the tool aberration errors are known to be transferred into the optical surface topography of x-ray mirrors. Our approach to improving metrology is to thoroughly calibrate the measuring tool and apply the results of the calibration to deconvolution of the measured data. Here we explore the application of a recently developed technique for calibrating the instrument transfer function (ITF) of 3D optical surface profilers to metrology with significantly curved x-ray optics. The technique, based on test standards patterned with two-dimensional (2D) binary pseudo-random arrays (BPRAs), employs the unique properties of the BPRA patterns in the spatial frequency domain. The inherent 2D power spectral density of the pattern has a deterministic white-noise-like character that allows direct determination of the ITF with uniform sensitivity over the entire spatial frequency range and field of view of an instrument. The high efficacy of the technique has been previously demonstrated in application to metrology with flat and slightly curved optics. Here, we concentrate on development of an efficient fabrication process for production of highly randomized (HR) BPRA test standards on flat and 500-mm spherical optical substrates. We also compare and discuss the results of the ITF calibration of an interferometric microscope when using the HR BPRA standards on flat and curved substrates.

Munechika, Keiko↗

Vehicle to Grid Communication Standards Development, Testing and Validation - Status Report

In the US, more than 10,000 electric vehicles (EV) have been delivered to consumers during the first three quarters of 2011. A large majority of these vehicles are battery electric, often requiring 220 volt charging. Though the vehicle manufacturers and charging station manufacturers have provided consumers options for charging preferences, there are no existing communications between consumers and the utilities to manage the charging demand. There is also wide variation between manufacturers in their approach to support vehicle charging. There are in-vehicle networks, charging station networks, utility networks each using either cellular, Wi-Fi, ZigBee or other proprietary communication technology with no standards currently available for interoperability. The current situation of ad-hoc solutions is a major barrier to the wide adoption of electric vehicles. SAE, the International Standards Organization/International Electrotechnical Commission (ISO/IEC), ANSI, National Institute of Standards and Technology (NIST) and several industrial organizations are working towards the development of interoperability standards. PNNL has participated in the development and testing of these standards in an effort to accelerate the adoption and development of communication modules.

33 ADVANCED PROPULSION SYSTEMS↗

Determination of Water Content in Bio-Oils by Volumetric Karl Fischer Titration: Laboratory Analytical Procedure (LAP)

The water content of bio-oils is a key metric for several reasons. Water is typically the most concentrated single component of fast pyrolysis oils, though this will be much lower in catalytic fast pyrolysis and upgraded products. Reduced water content is preferable in bio-oil as water can contribute to phase separation, corrosivity, and instability. Additionally, lower water is beneficial for physical properties such as energy density. The percentage of water can also be used to correct the calculation for organic oxygen when determining total oxygen content of bio-oils via combustion-based ultimate analysis. The procedure described here is specifically written for the analysis of bio-oils, and is based on ASTM E203, Standard Test Method for Water Using Volumetric Karl Fischer Titration. This standard test method is specified for measuring the mass % water in pyrolysis liquid biofuels in ASTM D7544, Standard Specification for Pyrolysis Liquid Biofuel. Although the standard method is prescribed for the analysis of pyrolysis liquids for use in industrial and commercial burners, the method is not specifically written for this product. The method described with this Laboratory Analytical Procedure (LAP) provides specific guidance for the analysis of bio-oils. Both organic and aqueous phases can be measured with this technique.

09 BIOMASS FUELS↗

Combined Transmission and Distribution Test System to Study High Penetration of Distributed Solar Generation

Transmission and distribution (T&D) standard test systems are currently defined separately, and are critical for researchers and engineers to test new solutions. Growing installation of energy resources in distribution and sub-transmission systems is creating higher interactions between T&D systems. This paper proposes a standard test system to study T&D interactions for high penetration of solar photovoltaic (PV) generation. The proposed test system can be used to study and propose solutions to problems such as reverse power flows and voltage control affected by PV variability. The proposed test system combines the transmission IEEE 118 bus system, with the distribution IEEE 123-node feeder. The original test systems are significantly enhanced by adding high penetration of solar PV generation with corresponding full-year minute-resolution chronological data. Conventional generation chronology is achieved by adding dispatch and unit commitment data for AC optimal power flow solutions. And chronological load data is added in both aggregated and disaggregated fashions. Sample applications of the data are provided highlighting voltage control challenges, and the proposed system is made available openly online.

Samaan, Nader A.↗

Test-Based Modeling of Photovoltaic Inverter Impact on Distribution Systems

Distributed PV has important effects on overcurrent, overvoltage and islanding protection. These effects are more difficult to analyze because the faulted behavior of PV inverters is less well understood than for rotating machines. Full transient models of the inverter can be accurate, but that approach requires inverter design details and simulation software that doesn’t easily interoperate with utility protection system software. Further, anomalous model behaviors often emerge at different grid conditions, and these are difficult to fix in a proprietary model. Testing provides another approach to characterize inverters, validate models or answer questions of application. This earlier work found major impacts from the inverter design, firmware, operating point and balance-of-system components. Our objective is to characterize PV inverters from black-box testing, leading to standard test reports that could provide parameter sets for widely-implemented models in software tools. The tool vendors can then develop standard inverter models, as they did for rotating machines and exciters. Besides fully detailed transient models, inverters can be represented with steady-state current sources, dynamically controlled current sources or non-linear frequency-dependent black boxes. Type-test data could support the last three kinds of model. Short circuit and sag tests would encompass the basic fault types, reporting the maximum transient and rms currents over all power levels and points-on-wave within four time ranges : 1) 0 to 1 cycles, for close and latch consideration 2) 1 to 4 cycles, for equipment withstand 3) 4 to 30 cycles, for interrupt ratings 4) 30 cycles and beyond, for backup protection analysis Open circuit tests would vary output power and power factor, and report the maximum rms voltage from 1 to 10 cycles after the event. Without models, the type-test data could also provide upper limits on the expected overvoltages and overcurrents.

Wieserman, Laura M.↗

Binary pseudo-random array standards for calibration of 3D optical surface profilers used for metrology with significantly curved x-ray optics

High-accuracy metrology is vitally important in manufacturing ultra-high-quality free-form mirrors designed to manipulate X-ray light with nanometer-scale wavelengths. The current capabilities and possibility for improvements in X-ray mirror manufacturing are limited by inherent imperfections of the integrated metrology tools. In the case of Fizeau interferometry, metrology tools are currently calibrated with super-polished flat test-standard/reference mirrors. This is acceptable for measuring slightly curved X-ray optics. However, for even moderately curved aspherical X-ray mirrors the flat-reference calibration is not sufficiently accurate and stitching Fizeau interferometer-based surface metrology is used to mitigate the problem. But still, the retrace and aberration errors, as well as the limited spatial resolution, described with the instrument transfer function (ITF), can be transferred into the optical surface topography of X-ray mirrors obtained in stitching metrology. For ITF calibration, we have developed an original technique, based on test standards structured as two-dimensional (2D) highly-randomized (HR) binary pseudo-random arrays (BPRAs). The technique employs the unique properties of the HR BPRA patterns in the spatial frequency domain., i.e. the inherent 2D power spectral density of the HR BPRA pattern has a deterministic white-noise-like character that allows direct determination of the ITF with uniform sensitivity over the entire spatial frequency range and field-of-view of an instrument. Here, we explore technological, metrological, and analytical aspects essential for calibration of the retrace and aberration errors of Fizeau interferometers using different types of tilted test samples, including a super-polished reference mirror for the re-trace calibration and the uniformly redundant array (URA) BPRA standards for the geometrical distortion (aberration) calibration. While the first method was previously demonstrated by researchers at DIAMOND Light Source, a method based on the URA BPRA is described and demonstrated here for the first time. We outline the design and fabrication process used in fabrication of URA BPRA test standards, and present the results of application of the URA BPRA standards demonstrating the high efficacy of our approach to geometrical distortion calibration of Fizeau interferometers. We also discuss the possible sources of unexpected peculiarities of the systematic errors, including an astigmatic character of the retrace error, observed with Fizeau interferometers at the Advanced Light Source X-Ray Optics Laboratory.

Munechika, Keiko↗

Gaseous contaminant transfer in membrane-based air-to-air energy exchangers

Membrane-based air-to-air energy exchangers (M–AAEEs) transfer heat and moisture between building exhaust air and fresh ventilation air streams through a membrane, thereby reducing the energy required for conditioning the fresh ventilation air. Energy exchangers are typically used in buildings with relatively clean building exhaust air, such as office buildings and schools. Recently interest in using energy exchangers in a wider range of buildings has grown, to reduce the energy consumption associated with the heating, ventilating, and air-conditioning (HVAC) systems in these buildings. However, if the building exhaust air is not clean, as would be the case for laboratories or factories, new risks are encountered when using energy exchangers. It is possible that gaseous contaminants in the exhaust air may also transfer along with the moisture through the membranes, contaminating the incoming fresh ventilation air. Current test standards provide a test procedure to determine the contamination of the fresh ventilation air by measuring the transfer of an inert tracer gas in an energy exchanger. However, the tracer gas test may not represent the transfer of common indoor air contaminants due to differences in their transport properties. Therefore, in this study, an experimental facility is developed to determine the transfer of seven different contaminants through two membranes (porous and dense) at different flow rates. Contaminant transfer is quantified using a parameter called the exhaust contaminant transfer ratio (ECTR), which gives the fraction of the contaminants transferred from the exhaust air to the fresh ventilation air. A theoretical model based on the effectiveness-number of transfer units (ε-NTU) correlation and moisture transfer resistance of the membrane is presented to determine transfer through porous membranes and validated with experimental results. The major contribution of this paper is that it presents a simple method to predict the transfer of different contaminants through a porous membrane based on the moisture transfer resistance of the membrane at different operating conditions. It is found that as contaminant diffusivity decreases, ECTR generally also decreases, and as the flow rate increases, ECTR decreases, which is consistent with the predictions from the correlation.

42 ENGINEERING↗

Tribology and Tool Wear of Hot Dip Galvanized Zinc Magnesium Alloys on Cold Rolled Steel Sheets

Recently zinc based coatings on cold rolled steel with improved functionality in terms of forming and/or corrosion behaviour have been intensively investigated in the steel industry. One of the most promising products are zinc magnesium alloys produced in hot dip galvanizing process. These coatings were already introduced in construction industry a few years ago. With some modifications the improved properties of the coating are also interesting for automotive industry. In the present work the tribological potential of hot dip galvanized zinc magnesium coatings (HDG/ZM) produced at an industrial line under regular production, was studied in terms of sliding properties, adhesive and abrasive tool wear.First a short introduction into surface morphology of HDG/ZM will be given. For the tribological characterization of the material, which is the main topic of the contribution, different tests were performed on hot dip galvanised zinc magnesium material and results were compared with classic hot dip galvanized zinc coating (HDG/Z). The investigations are mainly based on the strip draw test which allows the determination of the friction coefficient directly by using a constant contact pressure. Deep drawing property was tested by forming model cups. The abrasive tool wear was tested using a standard test for material used in automotive industry. The adhesive tool wear was investigated by characterizing the coating material transferred to the tool in the strip draw test.All performed tests show an improved drawability of HDG/ZM compared to classical HDG/Z reference material. However the most promising difference between HDG/ZM and HDG/Z is that galling was found to be less for HDG/ZM than for HDG/Z. Therefore HDG/ZM is an interesting system not only with respect to corrosion protection but also in terms of tribology and provides clear advantages in formability.

36 MATERIALS SCIENCE↗

Revisiting the blocking force test on ferroelectric ceramics using high energy x-ray diffraction

The blocking force test is a standard test to characterise the properties of piezoelectric actuators. The aim of this study is to understand the various contributions to the macroscopic behaviour observed during this experiment that involves the intrinsic piezoelectric effect, ferroelectric domain switching, and internal stress development. For this purpose, a high energy diffraction experiment is performed in-situ during a blocking force test on a tetragonal lead zirconate titanate (PZT) ceramic (Pb{sub 0.98}Ba{sub 0.01}(Zr{sub 0.51}Ti{sub 0.49}){sub 0.98}Nb{sub 0.02}O{sub 3}). It is shown that the usual macroscopic linear interpretation of the test can also be performed at the single crystal scale, allowing the identification of local apparent piezoelectric and elastic properties. It is also shown that despite this apparent linearity, the blocking force test involves significant non-linear behaviour mostly due to domain switching under electric field and stress. Although affecting a limited volume fraction of the material, domain switching is responsible for a large part of the macroscopic strain and explains the high level of inter- and intra-granular stresses observed during the course of the experiment. The study shows that if apparent piezoelectric and elastic properties can be identified for PZT single crystals from blocking stress curves, they may be very different from the actual properties of polycrystalline materials due to the multiplicity of the physical mechanisms involved. These apparent properties can be used for macroscopic modelling purposes but should be considered with caution if a local analysis is aimed at.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-Mileage Courier Fleet Vehicle Laboratory Battery Pack Testing

For one of each of the AVTA's plug-in hybrid electric vehicles, battery electric vehicles, and some hybrid electric vehicles tested in high-mileage courier fleets, the high-voltage traction battery packs were removed from the vehicle and tested at the beginning and end of fleet testing. For some vehicles, batteries also were tested at periodic intervals during fleet testing. Standard reference performance tests were conducted to characterize battery degradation over time. This dataset contains results from two or more rounds of battery tests for 21 distinct year/make/model vehicles (see reference ["INL Advanced Vehicle Testing Activity: On-road Logger and Laboratory Battery Pack Testing Vehicle List"](https://avt.inl.gov/sites/default/files/pdf/reports/DatasetVehicleList.pdf) for full list of vehicles). Each round of battery testing included the "Static Capacity Test" and the "Hybrid Pulse Power Characterization (HPPC) Test", conducted according to test procedures published in the United States Advanced Battery Consortium ["Battery Test Manual For Power-Assist Hybrid Electric Vehicles"](https://www.uscar.org/commands/files_download.php?files_id=57), ["Battery Test Manual For Plug-In Hybrid Electric Vehicles"](https://www.uscar.org/commands/files_download.php?files_id=168), and ["Electric Vehicle Battery Test Procedures Manual"](https://www.uscar.org/commands/files_download.php?files_id=5) prior to the time of testing. These tests were performed by Intertek Testing Services, North America. (This dataset will be shared by API; a small sample of the vehicle battery and test data has been extracted and is available for download while the API is being developed.)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-Mileage Courier Fleet Vehicle Laboratory Battery Pack Testing

For one of each of the AVTA's plug-in hybrid electric vehicles, battery electric vehicles, and some hybrid electric vehicles tested in high-mileage courier fleets, the high-voltage traction battery packs were removed from the vehicle and tested at the beginning and end of fleet testing. For some vehicles, batteries also were tested at periodic intervals during fleet testing. Standard reference performance tests were conducted to characterize battery degradation over time. This dataset contains results from two or more rounds of battery tests for 21 distinct year/make/model vehicles (see reference ["INL Advanced Vehicle Testing Activity: On-road Logger and Laboratory Battery Pack Testing Vehicle List"](https://avt.inl.gov/sites/default/files/pdf/reports/DatasetVehicleList.pdf) for full list of vehicles). Each round of battery testing included the "Static Capacity Test" and the "Hybrid Pulse Power Characterization (HPPC) Test", conducted according to test procedures published in the United States Advanced Battery Consortium ["Battery Test Manual For Power-Assist Hybrid Electric Vehicles"](https://www.uscar.org/commands/files_download.php?files_id=57), ["Battery Test Manual For Plug-In Hybrid Electric Vehicles"](https://www.uscar.org/commands/files_download.php?files_id=168), and ["Electric Vehicle Battery Test Procedures Manual"](https://www.uscar.org/commands/files_download.php?files_id=5) prior to the time of testing. These tests were performed by Intertek Testing Services, North America. This dataset is shared by API; a small sample of the vehicle battery and test data has been extracted and is also available for download.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗