Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “test procedure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Testing of Small Graphite Samples for Nuclear Qualification

Accurately determining the mechanical properties of small irradiated samples is crucial to predicting the behavior of the overal irradiated graphite components within a Very High Temperature Reactor. The sample size allowed in a material test reactor, however, is limited, and this poses some difficulties with respect to mechanical testing. In the case of graphite with a larger grain size, a small sample may exhibit characteristics not representative of the bulk material, leading to inaccuracies in the data. A study to determine a potential size effect on the tensile strength was pursued under the Next Generation Nuclear Plant program. It focuses first on optimizing the tensile testing procedure identified in the American Society for Testing and Materials (ASTM) Standard C 781-08. Once the testing procedure was verified, a size effect was assessed by gradually reducing the diameter of the specimens. By monitoring the material response, a size effect was successfully identified.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

PLUG-IN HYBRID ELECTRIC VEHICLE AND HYBRID ELECTRIC VEHICLE EMISSIONS UNDER FTP AND US06 CYCLES AT HIGH, AMBIENT, AND LOW TEMPERATURES

The concept of a Plug-in Hybrid Electric Vehicle (PHEV) is to displace consumption of gasoline by using electricity from the vehicle’s large battery pack to power the vehicle as much as possible with minimal engine operation. This paper assesses the PHEV emissions and operation. Currently, testing of vehicle emissions is done using the federal standard FTP4 cycle on a dynamometer at ambient (75°F) temperatures. Research was also completed using the US06 cycle. Furthermore, research was completed at high (95°F) and low (20°F) temperatures. Initial dynamometer testing was performed on a stock Toyota Prius under the standard FTP4 cycle, and the more demanding US06 cycle. Each cycle was run at 95°F, 75°F, and 20°F. The testing was repeated with the same Prius retrofi tted with an EnergyCS Plug-in Hybrid Electric system. The results of the testing confi rm that the stock Prius meets Super-Ultra Low Emission Vehicle requirements under current testing procedures, while the PHEV Prius under current testing procedures were greater than Super-Ultra Low Emission Vehicle requirements, but still met Ultra Low Emission Vehicle requirements. Research points to the catalyst temperature being a critical factor in meeting emission requirements. Initial engine emissions pass through with minimal conversion until the catalyst is heated to typical operating temperatures of 300–400°C. PHEVs also have trouble maintaining the minimum catalyst temperature throughout the entire test because the engine is turned off when the battery can support the load. It has been observed in both HEVs and PHEVs that the catalyst is intermittently unable to reduce nitrogen oxide emissions, which causes further emission releases. Research needs to be done to combat the initial emission spikes caused by a cold catalyst. Research also needs to be done to improve the reduction of nitrogen oxides by the catalyst system.

Seidman, M R↗

Improving energy performance metrics to maximize the benefits of disruptive technologies

Advances in appliance and equipment systems' technologies also cause changes in their technical characteristics that can affect energy consumption and associated greenhouse gas emissions. Energy performance evaluation methods that use testing and metrics can evolve to account for energy consumption contributed from new technological characteristics. However, there is no systematic effort to enable the advancement of test procedures and performance metrics to maximize the energy, climate, and financial benefits of disruptive technologies. Therefore, it is important for countries to regularly update their energy-efficiency policy programs, such as standards and labels, by improving test procedures and metrics to reflect the innovation in emerging technologies as well as to mitigate the risk of deploying obsolete technology. This paper shows how energy performance metrics have been improving in selected appliances and equipment and provides insights to design a systematic effort to improve metrics and test procedures at the speed of ongoing changes in technologies and markets.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Existing and Past Methods of Test and Rating Standards Related to Integrated Heat Pump Technologies

This report evaluates existing and past US methods of test and rating standards related to electrically operated air, water, and ground source air conditioners and heat pumps, 65,000 Btu/hr and under in capacity, that potentiality incorporate a potable water heating function. Two AHRI (formerly ARI) standards and three DOE waivers were identified as directly related. Six other AHRI standards related to the test and rating of base units were identified as of interest, as they would form the basis of any new comprehensive test procedure. Numerous other AHRI and ASHRAE component test standards were also identified as perhaps being of help in developing a comprehensive test procedure.

Reedy, Wayne R.↗

JV Task 112-Optimal Ethanol Blend-Level Investigation

Highway Fuel Economy Test (HWFET) and Federal Test Procedure 75 (FTP-75) tests were conducted on four 2007 model vehicles; a Chevrolet Impala flex-fuel and three non-flex-fuel vehicles: a Ford Fusion, a Toyota Camry, and a Chevrolet Impala. This investigation utilized a range of undenatured ethanol/Tier II gasoline blend levels from 0% to 85%. HWFET testing on ethanol blend levels of E20 in the flex fuel Chevrolet Impala and E30 in the non-flex-fuel Ford Fusion and Toyota Camry resulted in miles-per-gallon (mpg) fuel economy greater than Tier 2 gasoline, while E40 in the non-flex-fuel Chevrolet Impala resulted in an optimum mpg based on per-gallon fuel Btu content. Exhaust emission values for non-methane organic gases (NMOG), carbon monoxide (CO), and nitrogen oxides (NO{sub x}) obtained from both the FTP-75 and the HWFET driving cycles were at or below EPA Tier II, Light-Duty Vehicles, Bin 5 levels for all vehicles tested with one exception. The flex-fuel Chevrolet Impala exceeded the NMOG standard for the FTP-75 on E-20 and Tier II gasoline.

02 PETROLEUM↗

Building a Simplistic Automatic Extruder: Instrument Development Opportunities for the Laboratory

This work presents an automatic extruder as a research experience for undergraduate students. The system offers a user-friendly approach to preparing vesicles, such as liposomes or polymersomes, with a defined size and polydispersity properties crucial for research in biology and macromolecules. It comprises two syringe pumps connected by a membrane filter. The setup is controlled by software. Compared to manual extrusion, this automated system provides advantages, such as precisely controlled variables. The project describes a tool to enhance undergraduate learning in science and engineering laboratories. Building an automatic extruder serves as a simplified model of a complex industrial process. It offers a clear advantage: automating a well-understood manual extrusion process. To make this project accessible, it is broken down into three manageable tasks: software development, hardware assembly, and testing procedures. This breakdown describes the software created, the hardware components used, and the testing procedures conducted for this project. All project data, including software code, testing data, and procedures, are freely available online. This allows undergraduate students to not only begin their own projects but also contribute to this educational instrument’s ongoing development.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Furnace Blower Electricity: National and Regional Savings Potential

Currently, total electricity consumption of furnaces is unregulated, tested at laboratory conditions using the DOE test procedure, and is reported in the GAMA directory as varying from 76 kWh/year to 1,953 kWh/year. Furnace blowers account for about 80percent of the total furnace electricity consumption and are primarily used to distribute warm air throughout the home during furnace operation as well as distribute cold air during air conditioning operation. Yet the furnace test procedure does not provide a means to calculate the electricity consumption during cooling operation or standby, which account for a large fraction of the total electricity consumption. Furthermore, blower electricity consumption is strongly affected by static pressure. Field data shows that static pressure in the house distribution ducts varies widely and that the static pressure used in the test procedure as well as the calculated fan power is not representative of actual field installations. Therefore, accurate determination of the blower electricity consumption is important to address electricity consumption of furnaces and air conditioners. This paper compares the potential regional and national energy savings of two-stage brushless permanent magnet (BPM) blower motors (the blower design option with the most potential savings that is currently available in the market) to single-stage permanent split capacitor (PSC) blower motors (the most common blower design option). Computer models were used to generate the heating and cooling loads for typical homes in 16 different climates which represent houses throughout the United States. The results show that the potential savings of using BPM motors vary by region and house characteristics, and are very strongly tied to improving house distribution ducts. Savings decrease dramatically with increased duct pressure. Cold climate locations will see savings even in the high static pressure duct situations, while warm climate locations will see less savings overall and negative savings in the high static pressure duct situations. Moderate climate locations will see little or no savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-Mileage Courier Fleet Vehicle Laboratory Battery Pack Testing

For one of each of the AVTA's plug-in hybrid electric vehicles, battery electric vehicles, and some hybrid electric vehicles tested in high-mileage courier fleets, the high-voltage traction battery packs were removed from the vehicle and tested at the beginning and end of fleet testing. For some vehicles, batteries also were tested at periodic intervals during fleet testing. Standard reference performance tests were conducted to characterize battery degradation over time. This dataset contains results from two or more rounds of battery tests for 21 distinct year/make/model vehicles (see reference ["INL Advanced Vehicle Testing Activity: On-road Logger and Laboratory Battery Pack Testing Vehicle List"](https://avt.inl.gov/sites/default/files/pdf/reports/DatasetVehicleList.pdf) for full list of vehicles). Each round of battery testing included the "Static Capacity Test" and the "Hybrid Pulse Power Characterization (HPPC) Test", conducted according to test procedures published in the United States Advanced Battery Consortium ["Battery Test Manual For Power-Assist Hybrid Electric Vehicles"](https://www.uscar.org/commands/files_download.php?files_id=57), ["Battery Test Manual For Plug-In Hybrid Electric Vehicles"](https://www.uscar.org/commands/files_download.php?files_id=168), and ["Electric Vehicle Battery Test Procedures Manual"](https://www.uscar.org/commands/files_download.php?files_id=5) prior to the time of testing. These tests were performed by Intertek Testing Services, North America. (This dataset will be shared by API; a small sample of the vehicle battery and test data has been extracted and is available for download while the API is being developed.)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-Mileage Courier Fleet Vehicle Laboratory Battery Pack Testing

For one of each of the AVTA's plug-in hybrid electric vehicles, battery electric vehicles, and some hybrid electric vehicles tested in high-mileage courier fleets, the high-voltage traction battery packs were removed from the vehicle and tested at the beginning and end of fleet testing. For some vehicles, batteries also were tested at periodic intervals during fleet testing. Standard reference performance tests were conducted to characterize battery degradation over time. This dataset contains results from two or more rounds of battery tests for 21 distinct year/make/model vehicles (see reference ["INL Advanced Vehicle Testing Activity: On-road Logger and Laboratory Battery Pack Testing Vehicle List"](https://avt.inl.gov/sites/default/files/pdf/reports/DatasetVehicleList.pdf) for full list of vehicles). Each round of battery testing included the "Static Capacity Test" and the "Hybrid Pulse Power Characterization (HPPC) Test", conducted according to test procedures published in the United States Advanced Battery Consortium ["Battery Test Manual For Power-Assist Hybrid Electric Vehicles"](https://www.uscar.org/commands/files_download.php?files_id=57), ["Battery Test Manual For Plug-In Hybrid Electric Vehicles"](https://www.uscar.org/commands/files_download.php?files_id=168), and ["Electric Vehicle Battery Test Procedures Manual"](https://www.uscar.org/commands/files_download.php?files_id=5) prior to the time of testing. These tests were performed by Intertek Testing Services, North America. This dataset is shared by API; a small sample of the vehicle battery and test data has been extracted and is also available for download.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Rapid Quality Assessment in Additive Manufacturing: New Procedure Accelerates Build Quality Assessment. White paper

Accelerated growth of the additive manufacturing (AM) industry in recent years is accompanied by a rising need for methods to quickly assess quality at-scale. Current practices for quality inspection include nondestructive test methods and destructive testing of witness coupons, which are artifacts built alongside the actual part. However, these methods can be costly and time-consuming. Recognizing this need, the Additive Manufacturing Center of Excellence (AM CoE) initiated a project led by its partner, Auburn University, to develop rapid testing procedure using asbuilt samples tested in torsion to quantitatively assess build quality. The presented work developed a rapid testing procedure using as-built samples tested in torsion to quantify small variances for assessing build quality.

42 ENGINEERING↗

WE-A-210-00: Educational: Diagnostic Ultrasound QA

This presentation will focus on the present role of ultrasound medical physics in clinical practices. The first part of the presentation will provide an overview of ultrasound QC methodologies and testing procedures. A brief review of ultrasound phantoms utilized in these testing procedures will be presented. The second part of the presentation will summarize ultrasound imaging technical standards and professional guidelines by American College of Radiology (ACR), American Institute of Ultrasound in Medicine (AIUM), American Association of Physicists in Medicine (AAPM) and International Electrotechnical Commission (IEC). The current accreditation requirements by ACR and AIUM for ultrasound practices will be described and the practical aspects of implementing QC programs to be compliant with these requirements will be discussed. Learning Objectives: Achieve familiarity with common ultrasound QC test methods and ultrasound phantoms. Understand the coverage of the existing testing standards and professional guidelines on diagnostic ultrasound imaging. Learn what a medical physicist needs to know about ultrasound program accreditation and be able to implement ultrasound QC programs accordingly.

60 APPLIED LIFE SCIENCES↗

WE-A-210-01: Overview of Methods and Accreditation Updates

This presentation will focus on the present role of ultrasound medical physics in clinical practices. The first part of the presentation will provide an overview of ultrasound QC methodologies and testing procedures. A brief review of ultrasound phantoms utilized in these testing procedures will be presented. The second part of the presentation will summarize ultrasound imaging technical standards and professional guidelines by American College of Radiology (ACR), American Institute of Ultrasound in Medicine (AIUM), American Association of Physicists in Medicine (AAPM) and International Electrotechnical Commission (IEC). The current accreditation requirements by ACR and AIUM for ultrasound practices will be described and the practical aspects of implementing QC programs to be compliant with these requirements will be discussed. Learning Objectives: Achieve familiarity with common ultrasound QC test methods and ultrasound phantoms. Understand the coverage of the existing testing standards and professional guidelines on diagnostic ultrasound imaging. Learn what a medical physicist needs to know about ultrasound program accreditation and be able to implement ultrasound QC programs accordingly.

60 APPLIED LIFE SCIENCES↗

Correlating Dynamometer Testing to In-Use Fleet Results of Plug-In Hybrid Electric Vehicles

Standard dynamometer test procedures are currently being developed to determine fuel and electrical energy consumption of plug-in hybrid vehicles (PHEV). To define a repeatable test procedure, assumptions were made about how PHEVs will be driven and charged. This study evaluates these assumptions by comparing results of PHEV dynamometer testing following proposed procedures to actual performance of PHEVs operating in the US Department of Energy’s (DOE) North American PHEV Demonstration fleet. Results show PHEVs in the fleet exhibit a wide range of energy consumption, which is not demonstrated in dynamometer testing. Sources of variation in performance are identified and examined.

33 ADVANCED PROPULSION SYSTEMS↗

PLAN-TA9-2443(U), Rev. B Remediated Nitrate Salt (RNS) Surrogate Formulation and Testing Standard Procedure

This document identifies scope and some general procedural steps for performing Remediated Nitrate Salt (RNS) Surrogate Formulation and Testing. This Test Plan describes the requirements, responsibilities, and process for preparing and testing a range of chemical surrogates intended to mimic the energetic response of waste created during processing of legacy nitrate salts. The surrogates developed are expected to bound1 the thermal and mechanical sensitivity of such waste, allowing for the development of process parameters required to minimize the risk to worker and public when processing this waste. Such parameters will be based on the worst-case kinetic parameters as derived from APTAC measurements as well as the development of controls to mitigate sensitivities that may exist due to friction, impact, and spark. This Test Plan will define the scope and technical approach for activities that implement Quality Assurance requirements relevant to formulation and testing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Long-Term Creep Behavior of a CoCrFeNi Medium-Entropy Alloy

We report that current research shows that high-entropy alloys (HEAs) can offer superior oxidation resistance compared to more traditional austenitic stainless steels with equivalent tensile mechanical performance. While many reports have been published on creep of CoCrFeNiMn, few focus on the CoCrFeNi family of low to medium entropy alloys. In this manuscript, uniaxial tensile creep test results for more than 46,000 accumulated hours are presented on the equiatomic CoCrFeNi alloy. The alloy was manufactured at NETL using a vacuum induction melt solidification approach with a computationally designed homogenization cycle. After completing the homogenization cycle, the ingot was first hot forged and then hot rolled into 10 mm thick plate, a product form that is relevant to many industries. Creep tests were performed in the temperature range of 600-650 °C using applied stresses from 120 to 189 MPa. This study builds upon previous results on the CoCrFeNiMn family of high-entropy alloys and offers a modicum of clarification about performance compared to small button melts by using ASTM standard test procedures and mechanical test specimens. The apparent creep activation energy and creep stress exponent were similar to those for CoCrFe medium-entropy and CoCrFeNiMn high-entropy alloys. The post-test creep microstructure showed some Cr segregation, which has also been noted for other CoCrFe alloys. The CoCrFeNi alloy also presents a double minimum or two minimum creep rate phenomena.

36 MATERIALS SCIENCE↗

Fiber/matrix debonding evaluation of SiCf/SiC composites using micropillar compression technique

Third-generation silicon carbide (SiC) composites reinforced by SiC fibers (Hi-Nicalon S [HNS] and Tyranno SA3 [SA3]) are attractive for use in next generation reactors owing to their high strength and chemical inertness at high temperatures, as well as enhanced radiation tolerance under neutron irradiation environments. To optimize composite performance, the interfacial mechanical properties of chemical vapor–infiltrated (CVI) SiC f /SiC composites are investigated in this effort by using a slant interface micropillar compression testing procedure. The micropillar test specimens, containing an inclined pyrolytic carbon (PyC) interphase, are prepared using a focused ion beam. The novel microcompression testing successfully quantifies the debond shear strength and internal friction coefficient of micropillar test samples by using the Mohr-Coulomb formulation. Furthermore, according to four types of SiCf/SiC composite microcompression test results, interfacial properties and debond mechanisms are significantly affected by the PyC layer thickness, the local bonding mechanism of the PyC interphase on the SiC fiber surface, and the surface roughness of fibers. Regardless of PyC thicknesses, SA3-reinforced CVI SiC f /SiC composites are found to have much higher debond shear strengths than HNS-reinforced SiC f /SiC CVI composites. By using this micropillar compression technique alongside analytical methods, we uncover new understandings of PyC interface properties. Additionally, the micropillar test results obtained are correlated with macroscopic mechanical properties of neutron-irradiated CVI SiCf/SiC composites.

42 ENGINEERING↗

Steady-State Thermal Performance Evaluation of Steel-Framed Wall Assembly with Local Foam Insulation

During January and May, 2009, two configurations of steel-framed walls constructed with conventional 2 4 steel studs insulated with R-19 ~14cm. (5.5-in. thick) and R-13 ~9cm. (3.5-in. thick) fiberglass insulation batts were tested in the Oak Ridge National Laboratory (ORNL) guarded hot-box using ASTM C1363 test procedure. The first test wall used conventional 2 4 steel studs insulated with 2.5-cm. (1-in.) thick foam profiles, called stud snugglers. These stud snugglers converted the 2 4 wall assembly into a 2 6 assembly allowing application of R-19 fiberglass insulation. The second wall tested for comparison was a conventional 2 4 steel stud wall using R-13 insulation batts. Further, numerical simulations were performed in order to evaluate the steady-state thermal performance of various wood- and steel-framed wall assemblies. The effects of adding the stud-snugglers to the wood and steel studs were also investigated numerically. Different combinations of insulation and framing factor were used in the simulations.

09 BIOMASS FUELS↗

RG217 V2-V2 Coaxial Cable Acceptance Test

The ECSE Solid State Pulsed Power unit is a high current, high power solid-state pulse modulator. The RG217 V2-V2 Coaxial Cable Assembly is the interface cable between the Solid State Pulser and the load. This document covers the testing procedure for the RG217 V2-V2 Coaxial Cable Assembly. This assembly is comprised of RG217 Coaxial Cable with a LRU Connector on either end. This test procedure verifies the cable is undamaged and assembled correctly, the correct cable connectors are installed properly onto the cable, and that the entire assembly meets conductivity and holdoff voltage requirements. This procedure will verify that the RG217 Coaxial Cable Assembly meets all assembly and functional requirements. In particular, this procedure verifies the Cable Shield and Center Conductor meet conductivity requirements by testing their resistances. Additionally, this procedure ensures the RG217 Coaxial Cable Assembly meets holdoff voltage requirements by applying high voltage and verifying the RG217 Coaxial Cable Assembly does not experience any breakdowns or arcing.

42 ENGINEERING↗