Impedance Measurements of Motor Drives and Supplies in NASA NEAT Facility

Many electrified aircraft configurations consist of a number of power components operating on the same shared electrical bus. Understanding the impedance performance of electrical loads and sources is key to understanding, and designing for, acceptable overall vehicle power quality and power system stability. This paper discusses impedance measurements made on the NASA Electric Aircraft Testbed (NEAT) Electrical Power System (EPS) at NASA Glenn Research Center. First, an overall discussion of the NEAT facility configuration during testing is presented. Then, details of the impedance measurement approach and the various testing configurations are discussed. Next, input impedance measurements at NEAT, including sources (DC supplies) and loads (multiple motor drives, electric machines, and resistive load banks, with long interconnecting cable leads), are performed under a number of conditions, and results, including load model comparisons and stability analysis, are presented and discussed.

electrified aircraft propulsion↗

Impedance Measurements of Motor Drives and Supplies in NASA NEAT Facility

Many electrified aircraft configurations consist of a number of power components operating on the same shared electrical bus. Understanding the impedance performance of electrical loads and sources is key to understanding, and designing for, acceptable overall vehicle power quality and power system stability. This paper discusses impedance measurements made on the NASA Electric Aircraft Testbed (NEAT) Electrical Power System (EPS) at NASA Glenn Research Center. First, an overall discussion of the NEAT facility configuration during testing is presented; then details of the impedance measurement approach and the various testing configurations are discussed. Next, input impedance measurements at NEAT, including sources (DC supplies) and loads (multiple motor drives, electric machines, and resistive load banks, with long interconnecting cable leads), are performed under a number of conditions, and results, including load model comparisons and stability analysis, are presented and discussed.

electrified aircraft propulsion↗

Critical Propulsion and Noise reduction Technologies for Future Commercial Subsonic Engines. Area of Interest 14.3: Separate Flow Exhaust System Noise

This presentation discusses: Project Objectives, Approach and Goal; Baseline Nozzles and Test Cycle Definition; Repeatability and Baseline Nozzle Results; Noise Reduction Concepts; Noise Reduction Tests Configurations of BPR=5 Internal Plug Nozzle adn Acoustic Results; Noise Reduction Test Configurations of BPR=5 External Plug Nozzle and Acoustic Results; and Noise Reduction Tests Configurations of BPR=8 External Plug Nozzle and Acoustic Results.

Janardan, B. A.↗

A portable Ka-band front-end test package for beam-waveguide antenna performance evaluation. Part 2: Tests on the antenna

In part one of this article, a description was given of a Ka-band test package developed to enable testing of the Deep Space Station (DDS) 13 34-m beam-waveguide (BWG) antenna at 32 GHz. Test results were given for the Ka-band test package in an on-the-ground test configuration. This article is a companion article concerned with Ka-band test results for the test package in an on-the-antenna test configuration. Included are Ka-band zenith noise-temperature values, tipping-curve data, and subreflector test results obtained at the Cassegrain focal point, as well as at the final BWG focal point (located in a subterranean pedestal room). Test results show that, through the use of the Ka-band test package, the BWG antenna performance was successfully evaluated at Ka-band. The Ka-band test package operated well in all of the different antenna test configurations.

Otoshi, T. Y.↗

Electrodynamic Shaker Capability Estimation Through Experimental Dynamic Substructuring [Thesis]

Electrodynamic shaker systems are an essential tool in shock and vibration testing of dynamic environments. However, the specific performance capability of these systems is difficult to characterize. The dynamics of the shaker itself, the device under test and the specific test configuration used all couple to create a dynamic response unique to each test. Poorly predicted limitations in shaker capability affect the ability to achieve test specifications, delay testing schedules, and create difficulties for choosing test equipment. To predict shaker capability for a specific test configuration prior to setup, a lumped parameter model of the shaker system and a modal model of a device under test was developed. These models were then analytically coupled using LaGrange multiplier frequency based substructuring to estimate their coupled frequency response functions. The coupled frequency response functions were used to predict electrical inputs required to meet a given test specification. These input requirements were finally compared to a validation test using the specification and setup. Input requirements estimated using the substructuring estimated frequency response functions showed significant error. However, results using an ideal frequency response function showed very little error. These results indicate that with a better method of experimental dynamic substructuring employed it would be possible to accurately predict shaker capability for a given test configuration prior to setup.

42 ENGINEERING↗

Leading-edge deflection optimization for a highly swept arrow wing configuration

Tests were also conducted to determine the sensitivity of the lateral stability derivative C sub l sub beta to geometric anhedral. The optimized leading edge deflection was developed by aligning the leading edge with the incoming flow along the entire span. Owing to the spanwise variation of upwash, the resulting optimized leading edge was a smooth, continuously warped surface. For the particular configuration studied, levels of leading edge suction on the order of 90 percent were achieved with the smooth, continuously warped leading edge contour. The results of tests conducted to determine the sensitivity of C sub l sub beta to geometric anhedral indicate values of delta C sub l sub beta/delta T which are in reasonable agreement with estimates provided by simple vortex lattice theories.

Coe, P. L., Jr.↗

Influence of configuration effects on multiple burst simulation testing

During the initial phase of a lightning strike attachment on an aircraft, fast current pulses (rise time approximately 100 ns, I(sub max) approximately few kA) were measured, which can create equipment upsets or disturbances. This threat, made of repetitive pulses and usually called 'multiple bursts', can be reproduced at the equipment interfaces assuming that the transfer function of the structure was determined. The normalized waveform H (10 kA - 100 ns rise time) is the reference for one of these pulses. The importance of the coaxial return path termination for the injection of the wave H is emphasized. According to the constitutive materials of the test bed, and the adaptation of the line, the natural oscillations of the structure and the internal coupling mechanisms can be modified. As a conclusion, various test configurations in relation with the nature of the test bed and the characteristics of the generator are detailed, for a more accurate ground simulation of the attachment phase.

Emanuely, J. L.↗

Flow-Field Survey in the Test Region of the SR-71 Aircraft Test Bed Configuration

A flat plate and faired pod have been mounted on a NASA SR-71A aircraft for use as a supersonic flight experiment test bed. A test article can be placed on the flat plate; the pod can contain supporting systems. A series of test flights has been conducted to validate this test bed configuration. Flight speeds to a maximum of Mach 3.0 have been attained. Steady-state sideslip maneuvers to a maximum of 2 deg have been conducted, and the flow field in the test region has been surveyed. Two total-pressure rakes, each with two flow-angle probes, have been placed in the expected vicinity of an experiment. Static-pressure measurements have been made on the flat plate. At subsonic and low supersonic speeds with no sideslip, the flow in the surveyed region is quite uniform. During sideslip maneuvers, localized flow distortions impinge on the test region. Aircraft sideslip does not produce a uniform sidewash over the test region. At speeds faster than Mach 1.5, variable-pressure distortions were observed in the test region. Boundary-layer thickness on the flat plate at the rake was less than 2.1 in. For future experiments, a more focused and detailed flow-field survey than this one would be desirable.

Mizukami, Masashi↗

Mode Projection for Target Mode Identification

A method for projecting flight configuration eigenvectors onto the vector space of the test configuration eigenvectors is proposed. The underlying concept of the proposed method is that any flight configuration eigenvectors that can be replicated by a linear combination of test configuration eigenvectors, is correlated, if the constituent test eigenvectors are themselves correlated. Therefore, the modal test target mode shapes should be those test modes that combine to form the important modes of the flight configurations. This approach also recognizes that it is the deformed shapes that dictate what sections of the structure are “highly strained” (in a relative sense, within each mode shape), and that these “highly strained” sections require an accurate stiffness representation to achieve an accurate model correlation.

modal testing↗

Mode Projection Method for Target Mode Identification

A method for projecting flight configuration eigenvectors onto the vector space of the test configuration eigenvectors is proposed. The underlying concept of the proposed method is that any flight configuration eigenvectors that can be replicated by a linear combination of test configuration eigenvectors, is correlated, if the constituent test eigenvectors are themselves correlated. Therefore, the modal test target mode shapes should be those test modes that combine to form the important modes of the flight configurations. This approach also recognizes that it is the deformed shapes that dictate what sections of the structure are “highly strained” (in a relative sense, within each mode shape), and that it is these highly strained sections that require an accurate stiffness representation to achieve an accurate model correlation.

Modal Testing↗

Mode Projection Method for Target Mode Identification

A method for projecting flight configuration eigenvectors onto the vector space of the test configuration eigenvectors is proposed. The underlying concept of the proposed method is that any flight configuration eigenvectors (that can be replicated by a linear combination of test configuration eigenvectors) is correlated if the constituent test eigenvectors are themselves correlated. Therefore, the modal test target mode shapes should be those test modes that combine to form the important modes of the flight configurations. This approach also recognizes that it is the deformed shapes that dictate what sections of the structure are “highly strained” (in a relative sense, within each mode shape), and that these “highly strained” sections require an accurate stiffness representation to achieve an accurate model correlation.

Jeffrey A Peck↗

In Vitro Thrombogenicity Testing of Biomaterials in a Dynamic Flow Loop: Effects of Length and Quantity of Test Samples

Abstract The results of in vitro dynamic thrombogenicity testing of biomaterials and medical devices can be significantly impacted by test conditions. To develop and standardize a robust dynamic in vitro thrombogenicity tool, the key test parameters need to be appropriately evaluated and optimized. We used a flow loop test system previously developed in our laboratory to investigate the effects of sample length and the number of samples per test loop on the thrombogenicity results. Porcine blood heparinized to a donor-specific target concentration was recirculated at room temperature through polyvinyl chloride (PVC) tubing loops containing test materials for 1 h at 200 mL/min. Four test materials (polytetrafluoroethylene (PTFE), latex, PVC, and silicone) with various thrombotic potentials in two sample lengths (12 and 18 cm) were examined. For the 12-cm long materials, two different test configurations (one and two samples per loop) were compared. Thrombogenicity was assessed through percent thrombus surface coverage, thrombus weight, and platelet count reduction in the blood. The test system was able to effectively differentiate the thrombogenicity profile of the materials (latex > silicone > PVC ≥ PTFE) at all test configurations. Increasing test sample length by 50% did not significantly impact the test results as both 12 and 18 cm sample lengths were shown to equally differentiate thrombotic potentials between the materials. The addition of a second test sample to each loop did not increase the test sensitivity and may produce confounding results, and thus a single test sample per loop is recommended.

Engineering↗

CFD Simulations of the IHF 13-Inch Nozzle Flow: 55° Sphere-Cone Model, Manufactured Fences and Gaps

Introduction to Arc-Jets and Testing - Arc-jets are primary facilities to test the performance of thermal protection systems (TPS) in an aerothermodynamic heating environment - Free jet test configuration with stagnation coupon or wedge models—conical nozzles - Semi-free jet test configuration with panel test articles—semi-elliptical nozzles A large-scale sphere-cone model, though similar to stagnation models, enables testing TPS materials in combinations of heat flux, pressure and shear different from those accessible in various stagnation and wedge tests

Arc-jets↗

Hazard Analysis for the Mark III Space Suit Assembly (SSA) Used in One-g Operations

This Hazard Analysis document encompasses the Mark III Space Suit Assembly (SSA) and associated ancillary equipment. It has been prepared using JSC17773, "Preparing Hazard Analyses for JSC Ground Operation", as a guide. The purpose of this document is to present the potential hazards involved in ground (23 % maximum O2, One-g) operations of the Mark III and associated ancillary support equipment system. The hazards listed in this document are specific to suit operations only; each supporting facility (Bldg. 9, etc.) is responsible for test specific Hazard Analyses. A "hazard" is defined as any condition that has the potential for harming personnel or equipment. This analysis was performed to document the safety aspects associated with manned use of the Mark III for pressurized and unpressurized ambient, ground-based, One-g human testing. The hazards identified herein represent generic hazards inherent to all standard JSC test venues for nominal ground test configurations. Non-standard test venues or test specific configurations may warrant consideration of additional hazards analysis prior to test. The cognizant suit engineer is responsible for the safety of the astronaut/test subject, space suit, and suit support personnel. The test requester, for the test supported by the suit test engineer and suited subject, is responsible for overall safety and any necessary Test Readiness Reviews (TRR).

Mitchell, Kate↗

Interfacial stress state present in a 'thin-slice' fibre push-out test

An analysis of the stress distributions along the fiber-matrix interface in a 'thin-slice' fiber push-out test is presented for selected test geometries. For the small specimen thicknesses often required to displace large-diameter fibers with high interfacial shear strengths, finite element analysis indicates that large bending stresses may be present. The magnitude of these stresses and their spatial distribution can be very sensitive to the test configuration. For certain test geometries, the specimen configuration itself may alter the interfacial failure process from one which initiates due to a maximum in shear stress near the top surface adjacent to the indentor, to one which involves mixed mode crack growth up from the bottom surface and/or yielding within the matrix near the interface.

Kallas, M. N.↗

IOTA Pre-Bake Test Development

The poster presentation prepared for the IOTA (Integrable Optics Test Accelerator) Pre-Bake Test Development project consists of introducing the background of the project, the work completed, and the new test configurations available with the newly designed assembly. It explains the scale of the projects, both within the IOTA ring assembly and test assembly, and describes the purpose in baking or incrementing and holding exterior heat on the beampipe to reduce impurities in the vacuum. The originally designed test, Configuration One, uses RCA scans on the interior of the pipe, increments and holds heat for a set amount of time, and is scanned again to check for water evaporation. Configuration Two begins with the same test for Configuration One but has a second cross section of beampipe separated by a gate valve. After configuration one is complete, the gate valve opens, and after a period of cooling the other side is heated, molecular movement is scanned and observed.

Seagrave, Kayla [DuPage Coll.]↗

Performance of a 12-GHz fiber-optic system for beam-waveguide antenna stability testing

A 12-GHz fiber-optic system is a critical part of a test configuration that was proposed for measuring the fractional frequency stability of the Deep Space Station (DSS)-13 beam-waveguide (BWG) antenna. This fiber-optic system is used to carry Ku-band (12-GHz) signals from a reference antenna to the DSS-13 BWG pedestal room. Tests performed only on the fiber-optic system portion of the overall test configuration showed that the 12-GHz fiber-optic system (installed at DSS-13) has a frequency stability of about 1.1 x 10(exp -16) for sampling time tau = 1000 sec for a nighttime run. This preliminary result establishes the lowest noise floor that can probably be achieved for the test configuration that will be used to measure the frequency stability of the DSS-13 BWG antenna.

Otoshi, T. Y.↗