Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “temperature sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Monitoring the readout temperature in the ICARUS TPC (2023 Italian Students Program Final Report)

Being a Liquid Argon Time Projection Chamber (LAr-TPC) detector, ICARUS exploits a series of three parallel wire planes to measure and collect the ionization charge coming from an event inside the active volume. The wires are read out by A2795 custom boards, arranged in crates located on top of the two liquid Argon vessels. Each board is provided with two temperature sensors that allow temperature monitoring while the experiment is running: this is key in order to ensure data reliability and maintain hardware in safe conditions. Moreover, temperature-related problems may force unplanned shutdowns that result in losing valuable time for the experiment to run. In this work we are discussing the characterization of the ICARUS TPC board temperatures and the system we implemented in order to monitor them effectively. Among the tools used, Grafana results in a valid application for both displaying temperature data and sending alerts to the shifters whenever a pathological situation occurs.

42 ENGINEERING↗

Method and system to measure gas flow

A system for measuring gas flow generally including a passive acoustic wave generator disposed in a gas flow stream to passively generate an audio signal through vortex shedding, a sound capturing instrument disposed outside the gas stream to produce an electrical signal representative of the acoustic signal, a temperature sensor to obtain temperature measurements indicative of the temperature of the gas flow stream and a control system for determining the gas flow, such as velocity or flow rate, as a function of the acquired acoustic and temperature measurements. The acoustic wave generator includes a corrugated flow channel whose geometric design is so tuned to generate an acoustic emission whose frequency signature varies as a function of the gas flow velocity. The control system may acquires time-domain acoustic data, and process that data to obtain a frequency-domain representation from which gas velocity or gas flow rate can be determined.

Cetiner, Mustafa S.↗

Single-photon detection using large-scale high-temperature MgB2 sensors at 20 K

Abstract Ultra-fast single-photon detectors with high current density and operating temperature can benefit space and ground applications, including quantum optical communication systems, lightweight cryogenics for space crafts, and medical use. Here we demonstrate magnesium diboride (MgB 2 ) thin-film superconducting microwires capable of single-photon detection at 1.55 μ m optical wavelength. We used helium ions to alter the properties of MgB 2 , resulting in microwire-based detectors exhibiting single-photon sensitivity across a broad temperature range of up to 20 K, and detection efficiency saturation for 1 μ m wide microwires at 3.7 K. Linearity of detection rate vs incident power was preserved up to at least 100 Mcps. Despite the large active area of up to 400 × 400 μ m 2 , the reset time was found to be as low as ~ 1 ns. Our research provides possibilities for breaking the operating temperature limit and maximum single-pixel count rate, expanding the detector area, and raises inquiries about the fundamental mechanisms of single-photon detection in high-critical-temperature superconductors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-Temperature Gas Sensor Materials with Properties Predicted via First-Principles Calculations with Machine Learning Modeling and Experimental Corroboration

Understanding the temperature dependence of functional properties of sensing materials is vital for their applications in combustion environments. The electron-phonon coupling that derives the electronic structure change with temperatures is a key property of interest as it affects other sensing responses. Herein, we first assess the temperature dependence of band gap renormalization in sensing materials by employing Allen-Heine-Cardona (AHC) theory with density functional theory (DFT) simulations corroborated with experimental observation. As the AHC calculations are impractical for high-throughput screening of materials, we employ data-driven Gaussian process regression to predict the parameters employed in the O’Donnell empirical model from a set of physical features. To mitigate the reliability issues arising from the small size of the dataset, we apply a Bayesian technique to improve the generalizability of the data-driven models as well as to quantify the uncertainty associated with theoretical predictions. These models capture well the overall trend of the O’Donnell parameters with respect to a reduced feature set obtained by transforming the available physical features. Quantifying the associated uncertainty helps us understand the reliability of the predictions and, therefore, the variation of bandgap as a function of temperature for other novel materials. The predicted candidates from machine learning models are further validated by experiments and DFT calculations.

bandgap renormalization↗

On-Line Lead/Water Heat Exchanger Sensor/System Feasibility: CRADA 462 [Abstract Only]

The purpose of this project is to develop and demonstrate the feasibility of a high-temperature sensor for on-line structural health monitoring (OLSHM) of the novel heat exchanger tubes in the Hydromine lead cooled reactor. The high temperature sensor takes advantage of the Hydromine heat exchanger tube design that has a relatively cool inlet temperature (~ 350 °C) and the tube ends are in an Argon gas blanket rather than being submerged in a corrosive fluid and the tube ends are conveniently accessible from the periphery of the heat exchanger shell.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High-Temperature Wireless Sensor Platform Powered by Energy Scavenging

This paper reports on the development of key components required for a self-powered oscillator unit designed to wirelessly transmit its signal under full insertion in high-temperature (HT) harsh-environments (HE), such as those present in power plants and industrial settings (metallurgic, oil extraction, molding, and aerospace). The oscillator employed a silicon carbide (SiC) power transistor and HT passive components on a screen-printed alumina circuit board capable of operation beyond 300 °C. The HT oscillator circuit was powered solely by in-situ energy scavenging thermoelectric generator (TEG) modules using passive cooling, eliminating the need for an external power supply or active cooling. In addition, a silicon-based external booster circuit was used to achieve the required TEG voltage regulation to test the TEG-powered HT oscillator circuit. The TEG-powered oscillator circuit was tested inside a non-metallic furnace from room temperature to over 300 °C for transmission of a wireless signal, which was detected outside the furnace at 11 ft (3.4 m). Such a wireless transmitting system powered only by in-situ TEGs, with no requirement for external power or active cooling, is very attractive for flexible, mobile stand-alone control and sensor units targeted for operation in HT HE conditions found in power plants and industrial settings.

20 FOSSIL-FUELED POWER PLANTS↗

Deep Neural Network Assisted Distributed Strain and Temperature Fiber Sensor System for Natural Gas Pipeline Monitoring

Natural gas pipeline integrity monitoring is crucial to detect potential leaks, find structural issues, and prevent environmental damage. This article presents a system of natural gas pipeline monitoring that uses a specialized double Brillouin peak sensing fiber along with the Brillouin optical time domain analysis (BOTDAs) technique. The calibrated sensing fiber coefficients for strain and temperature are 41.8 kHz/ με and 0.9 MHz/°C for peak 1; and 47.2 kHz/ με , and 1.11 MHz/°C for peak 2, respectively. Initially, lab tests were performed by installing a short section of double Brillouin peak fiber (DBPF) on a 1-in steel pipe under pressure up to 1000 per square inch (psi) at elevated temperatures. Simultaneous distributed measurements of temperature and pressure-induced hoop strain were successfully measured. Considering the long processing speed to extract Brillouin frequency shift (BFS), we employ a novel probabilistic deep neural network (PDNN) framework for rapid BFS prediction. Additionally, using the Finite Element Method, the effects of the pipeline pressure on hoop strain were modeled and compared to the experimental hoop strain under the same set of pipeline conditions. Finally, an actual 4-in outer diameter steel natural gas pipeline was used for pilot-scale tests, where hoop strain was measured at various pressure levels. Leaks were simulated to demonstrate accurate pipeline integrity monitoring. At an internal pipe pressure of 1000 psi, hoop strain of approximately 300 με was observed, and the sensitivity was calculated as 0.28 με /psi. The results of this pilot-scale study demonstrated that the system is capable of performing distributed monitoring sufficient to detect pipeline pressure and the presence of leaks to ensure the safe operation of gas pipelines in the field.

03 NATURAL GAS↗

Cross-Scale Land-Atmosphere Experiment (CSLAEX) (Final Report)

It is now well recognized that land-atmosphere interactions play an important role in both weather and climate. These interactions take place over a wide range of spatial and temporal scales. Most of the current formulations of the momentum, heat and moisture transport laws are informed by observations with a limited temporal or spatial scale, and hence may have limited applicability. The objective of this work is to improve the multi-scale representation of the near-surface heat transfer in the ground and in the atmosphere using a combination of modeling and field observations. Our knowledge and predictive capacity in land-atmosphere coupling is limited by our capacity to observe the full-scale spectrum at play. In order to bridge this fundamental gap in our observation capacity I will work to: create the first long-term Integrated Cross-Scale land-Atmosphere Experiment (CSLAEX) since I will work to: measure the components of the surface energy balance at a spatial scale relevant to remote sensing and meteorological applications (5km), along with observations of the nested subscale processes with Distributed Temperature Sensors (DTS). This proposal aims to fill the gaps in modeling and observing land-atmosphere interactions across scales via a novel Cross-Scale Land-Atmosphere Experiment (CSLAEX) to be implemented as part of the Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) site near Lamont, Oklahoma. The proposed research effort aims at exploring land-atmosphere processes across multiple spatial scales and to investigate the effect of landscape heterogeneity using Distributed Temperature Sensor measurements. The novel instrumentation of the Surface Energy Balance and simultaneous observations of the atmospheric state (boundary layer, cloud, convection) available at the DOE ARM SGP site will be used to create CSLAEX. This dataset will be used to frame and evaluate new transport laws and parameterizations for the boundary layer and the land surface, which can be implemented into the Weather and Research Forecasting (WRF) model and Community Atmospheric Model (CAM). The result of this study should impact multiple fields: meteorology, climate, and hydrology.

54 ENVIRONMENTAL SCIENCES↗

Continuous snow depth, ground interface temperature and shallow soil temperature measurements from 2021-10-1 to 2022-6-14, Seward Peninsula, Alaska

The dataset contains co-located snow depth, ground interface temperature, and shallow soil temperature measured at 98 discrete locations in a watershed located along the Nome-Teller road at mile marker 27 (referred to as T27), and at 53 discrete locations on a hillslope located along the Kougarok road at mile marker 64 (referred to as K64), in Seward Peninsula, Alaska. The dataset aims to understand the local heterogeneity of snow depth, snow temperature, and soil temperature dynamics and their interactions in a discontinuous permafrost region. The dataset is also valuable to train and evaluate machine learning and physical models to predict snow depth or the impact of snow depth on ground surface temperature. At each location, temperatures above and below the ground surface were measured by a pair of vertically deployed distributed temperature profiling probes designed based on Dafflon et al (2022). The probes have high precision temperature sensors spaced at 5 or 10 cm. The mean daily snow depth was estimated by identifying the pair of consecutive sensors with maximum drop of daily temperature high-frequency fluctuations. The ground interface temperature was measured by the sensor located 1-5 cm above the ground surface at 15-minute intervals. The shallow soil temperature was measured by the sensor located 1-5 cm below the ground surface at 15-minute intervals. The dataset includes a description of the probe locations in the "Probe_locations_*.csv" file and the 3 data files (Snow_depths_*.csv, Ground_interface_temperatures_*.csv, Shallow_soil_temperatures_*.csv). * is either T27 or K64, which are the two study sites. In each data file, each column corresponds to a measurement location. Metadata files include data descriptions (_dd.csv) for tabular data. All included files are listed and described in xxxx_flmd.csv. A more detailed description of data processing, along with an updated dataset incorporating multiple seasons and improved snow depth estimation is available at https://doi.org/10.15485/2480365 (Wang et al., 2025a, Wang et al., 2025b).The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Experimental study on the startup of the annular wick type heat pipe using fiber optical temperature measurement technique

This study used optical fiber-distributed temperature sensors to measure the internal and external temperature distributions of a water-cooled heat pipe. The sensor technology used in this study is fiber optical distributed temperature sensing, a distributed sensing technique based on the naturally occurring Rayleigh backscatter in optical fibers. This measurement technique provides maximum spatial resolution for static and semi-static applications. Using this sensor, the temperature distribution of the heat pipe's internal, external, vapor core, and the wick was measured with a spatial resolution of 0.65 mm, a sampling frequency of 40 Hz, and a temperature resolution of 0.1 °C. Through the measured temperature distribution database, the starting phenomenon, the effective length trend, and the limitation onset were observed. From the results, it is found that a high-temperature peak appears at the evaporator if a high initial power (75 W) is imposed on the heat pipe, even after the heat pipe approaches the normal operating status. The peak is not observed in a slower startup (30 W initial power then slowly increased to 75 W). It is also found that the temperature distributions and effective condenser length of the heat pipe highly depend on the cooling conditions. There are variations in the temperature according to the radial direction of the horizontal heat pipe due to gravity. In conclusion, lead and lag of the temperature evolution were observed at the onset of the operating limitations.

42 ENGINEERING↗

An Adaptive Reference Scheme to Extend the Functional Range of Optical Backscatter Reflectometry in Extreme Environments

Optical frequency domain reflectometry (OFDR) measurements are performed by recording the interference pattern of light backscattered by density fluctuations or Bragg gratings along the length of an optical fiber. Changes in local temperature or strain in the fiber cause shifts in the backscattered light spectrum, which can be calibrated to the applied temperature or strain. Comparing the backscattered optical spectra from each reflection site with a reference (unstrained) spectrum allows for quantification of local spectral shifts. While mature OFDR-based technologies can provide high-precision spatially distributed measurements over kilometer lengths, the post-processing approaches used to recover spectral shifts from raw optical intensity data can limit the use of OFDR in harsh environments. This paper presents a novel approach to post-processing OFDR data which extends the usability of optical fibers exposed to harsh environments. This approach is the first to use the spectral shift quality, calculated for two OFDR measurements, to identify an appropriate reference scan from which the spectral shift can be determined. Here, three experimental data sets are used to test the algorithm: (1) an optical fiber heated to >950°C, (2) an aluminum-embedded optical fiber under strain from differential thermal expansion, and (3) an optical fiber exposed to a total neutron flux of 2×10 13 n/cm 2 /s over 40 hours in a nuclear test reactor. Results show that using a metric of quality to select an appropriate reference measurement extends the functional range of OFDR strain and temperature sensors. Furthermore, this algorithm can be applied to existing OFDR data.

47 OTHER INSTRUMENTATION↗

High Temperature Electrochemical Sensors for In-Situ Corrosion Monitoring in Coal-Based Power Generation Boilers

In this project, we successfully achieved the goals we proposed: 1. optimization and development of electrochemical sensor, 2. sensor construction and package, 3. sensor testing @Longview Power Plant and data analysis, 4. lab-scale sensor optimization and corrosion database development, 5. electrochemical and corrosion monitoring validation and 6. TEA.

01 COAL, LIGNITE, AND PEAT↗

Biodegradable Temperature & pH Sensors VIASTIMULI-Responsive Polymers

Soil sensors play a key role in agriculture, and for good reason; knowledge about soil conditions enables farmers to make informed decisions about resource expenditure and crop selection for areas of land. On an industrial agriculture scale, though, this is difficult; the average U.S. farm is approximately 500 acres. To put that in perspective, if you’ve driven past Concannon Winery, all that land is only about 200 acres. This is why modern state-of-the-art soil sensors need to be equipped to not only collect precise and accurate data, but also to transmit that data large distances.

36 MATERIALS SCIENCE↗

Additive Manufacturing of Miniaturized Peak Temperature Monitors for In-Pile Applications

Passive monitoring techniques have been used for peak temperature measurements during irradiation tests by exploiting the melting point of well-characterized materials. Recent efforts to expand the capabilities of such peak temperature detection instrumentation include the development and testing of additively manufactured (AM) melt wires. In an effort to demonstrate and benchmark the performance and reliability of AM melt wires, we conducted a study to compare prototypical standard melt wires to an AM melt wire capsule, composed of printed aluminum, zinc, and tin melt wires. The lowest melting-point material used was Sn, with a melting point of approximately 230 °C, Zn melts at approximately 420 °C, and the high melting-point material was aluminum, with an approximate melting point of 660 °C. Through differential scanning calorimetry and furnace testing we show that the performance of our AM melt wire capsule was consistent with that of the standard melt-wire capsule, highlighting a path towards miniaturized peak-temperature sensors for in-pile sensor applications.

36 MATERIALS SCIENCE↗

Comparison of fiber-optic distributed temperature sensing and high-sensitivity sensor spatial surveying of stream temperature

Measuring surface water temperature spatial variability is needed to estimate the interaction between surface water and groundwater, evaluate fish habitat and thermal inertia, and to estimate streamflow frequency and duration. Fiber optic distributed temperature sensing (FO-DTS) has been used in rivers and lakes, providing high-resolution and sensitive temperature monitoring over large temporal and spatial scales. However, in streams with cobbly or bedrock-lined streambeds and variable bathymetry, use of FO-DTS to measure temperature close to the surface water and groundwater interface can be challenging if even feasible. FO-DTS can also be costly, involve difficult installations, and require an advanced understanding of the technology, calibration, and data processing. In this study, we compared FO-DTS stream temperature survey results to an alternative temperature survey method employing a towed transect of high-resolution temperature loggers spaced at 1-m and transported in the stream along the study reach, to measure the spatial distribution of stream-water temperature in East Fork Poplar Creek near Oak Ridge, Tennessee, USA. We assessed the applicability and limitations of the two methods, and quantitatively compared in-situ temperature survey results measured simultaneously with each method. Regression results showed strong temporal and spatial correlation between the two methods. Differences were only elevated near the stream banks in areas that were coincident with correlation slope deviations from unity, which was attributed to shallower water and lower data density. Kriging standard errors were also low at channel center with minor increases near the stream banks. Furthermore, the results suggested that the array of the individual temperature sensors can provide a practical alternative to FO-DTS for thermal characterization of surface water, providing slightly lower spatial and temporal resolution, but with higher accuracy of temperature measurement, with greater simplicity, and with a broader range of conditions where it may be applied.

54 ENVIRONMENTAL SCIENCES↗