At least 91 records · Page 5

2016 Annual Reuse Report for the Idaho National Laboratory Site’s Advanced Test Reactor Complex Cold Waste Ponds

This report describes conditions and information, as required by the state of Idaho, Department of Environmental Quality Reuse Permit I-161-02, for the Advanced Test Reactor Complex Cold Waste Ponds located at Idaho National Laboratory from November 1, 2015–October 31, 2016. The effective date of Reuse Permit I-161-02 is November 20, 2014 with an expiration date of November 19, 2019. This report contains the following information: • Facility and system description • Permit required effluent monitoring data and loading rates • Permit required groundwater monitoring data • Status of compliance activities • Issues • Discussion of the facility’s environmental impacts. During the 2016 permit year, 180.99 million gallons of wastewater were discharged to the Cold Waste Ponds. This is well below the maximum annual permit limit of 375 million gallons. As shown by the groundwater sampling data, sulfate and total dissolved solids concentrations are highest in well USGS-065, which is the closest downgradient well to the Cold Waste Ponds. Sulfate and total dissolved solids concentrations decrease rapidly as the distance downgradient from the Cold Waste Ponds increases. Although concentrations of sulfate and total dissolved solids are significantly higher in well USGS-065 than in the other monitoring wells, both parameters remained below the Ground Water Quality Rule Secondary Constituent Standards in well USGS-065. The facility was in compliance with the Reuse Permit during the 2016 permit year.

2016 Annual Reuse Report for the Idaho National La↗

Coordination and Control of Flexible Building Loads for Renewable Integration; Demonstrations using VOLTTRON

Renewable energy resources such as wind and solar power have a high degree of uncertainty. Large-scale integration of these variable generation sources into the grid is a big challenge for power system operators. Buildings, in which we live and work, consume about 75% of the total electricity in the United States. They also have a large capacity of power flexibility due to their massive thermal capacitance. Therefore, they present a great opportunity to help the grid to manage power balance. In this report, we study coordination and control of flexible building loads for renewable integration. We first present the motivation and background, and conduct a literature review on building-to-grid integration. We also compile a catalog of flexible building loads that have great potential for renewable integration, and discuss their characteristics. We next collect solar generation data from a photovoltaic panel on Pacific Northwest National Laboratory campus, and conduct data analysis to study their characteristics. We find that solar generation output has a strong uncertainty, and the uncertainty occurs at almost all time scales. Additional data from other sources are also used to verify our study. We propose two transactive coordination strategies to manage flexible building loads for renewable integration. We prove the theories that support the two transactive coordination strategies and discuss their pros and cons. In this report, we select three types of flexible building loads—air-handling unit, rooftop unit, and a population of WHs—for which we demonstrate control of the flexible load to track a dispatch signal (e.g., renewable generation fluctuation) using experiment, simulation, or hardware-in-the-loop study. More specifically, we present the system description, model identification, controller design, test bed setup, and experiment results for each demonstration. We show that coordination and control of flexible loads has a great potential to integrate variable generation sources. The flexible loads can successfully track a power dispatch signal from the coordinator, while having little impact on the quality of service to the end-users.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2017 Annual Reuse Report for the Idaho National Laboratory Site's Advanced Test Reactor Complex Cold Waste Ponds

This report describes conditions and information, as required by the state of Idaho, Department of Environmental Quality Reuse Permit I-161-02, for the Advanced Test Reactor Complex Cold Waste Ponds located at Idaho National Laboratory from November 1, 2016–October 31, 2017. The effective date of Reuse Permit I-161-02 is November 20, 2014 with an expiration date of November 19, 2019. A permit modification, I-161-02: Modification 1, became effective March 7, 2017. The modification incorporated clarification to the delivery of analytical reports and chain of custody forms. This report contains the following information: • Facility and system description • Permit required effluent monitoring data and loading rates • Permit required groundwater monitoring data • Status of compliance activities • Issues • Discussion of the facility’s environmental impacts. During the 2017 permit year, 234.05 million gallons of wastewater were discharged to the Cold Waste Ponds which is below the maximum annual permit limit of 375 million gallons. Sulfate and total dissolved solids concentrations continue to remain highest in well USGS-065, which is the closest downgradient well to the Cold Waste Ponds. As shown by the groundwater sampling data, sulfate and total dissolved solids concentrations decrease rapidly as the distance downgradient from the Cold Waste Ponds increases. The concentrations of all permit-required parameters were below their respective groundwater quality standard levels (IDAPA 58.01.11) for all six groundwater monitoring wells. There was one noncompliance with the Reuse Permit during the 2017 permit year. Approximately 600 gallons of cooling water was discharged to ground surface outside of the designated application site. DEQ was notified of the noncompliance.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Parameterization Study of Sew-EZ Materials: Types #6 and #8

Two material types identified by Sew-EZ were tested in various configurations, and under various conditions, by Sandia National Laboratories (SNL). The primary focus of this study was to assess the filtration performance of these two materials and identify if they perform similarly to certified N95 respirators. Testing was conducted on two systems which use distinctly different techniques to characterize the aerosol penetration characteristics of materials: a) R&D Filtration System: A large-scale R&D filtration system was used with testing parameters that mimicked NIOSH guidelines, where possible. Efficiency data as a function of particle size was attained using NaC1 as the test aerosol and a Scanning Mobility Particle Sizer (SMPS) for measurements. A more detailed system description can be found in Omana et al. 2020. b) Automated Tester: A commercial, automated filter tester (100Xs, Air Techniques International) was used to provide penetration/efficiency data for Sew EZ materials. The 100Xs aerosolizes a polydisperse NaC1 aerosol with a consistent concentration and size profile. The 100Xs manual (Air Techniques International 2018) states, "The aerosol particle size and distribution are designed to meet all requirements as defined in the relevant sections of NIOSH 42 CFR, Part 84 (pg. 32)."

36 MATERIALS SCIENCE↗

Introduction to ALERT: A User-Interface Tool for Resilient Optimization

As the cyber-physical systems grow in complexity, there is a need for proactive resilience strategies that involve online, adaptive control actions to best prepare for any impending adversarial events. In this technical effort, supported by RD2C LDRD initiative, the project team designed and demonstrated online strategies – referred to as ALERT controls – for proactive and adaptive tuning of existing optimal controls in a microgrid, with quantifiably assured margins of resilience to various cyber-physical adversarial events. This ALERT functionality is made available to the end-users, e.g., the system operators, via an interactive user-interface. The end-users will not only be able to use the interface to visualize the system’s operation under various cyber-physical adversarial scenarios, but also evaluate the amount of tolerance the system has against selected adversarial perturbations of interest (e.g., malfunctioning sensors, suspected attacked measurements) via the adversarial plots. In this technical report, we briefly outline the algorithmic modules of the developed ALERT control technology, and introduce the user-interface tool that allows end-users (e.g., microgrid operators) to enter their system description, specify various operational and resilience requirements, and evaluate the impact of the control decisions via illustrative plots.

97 MATHEMATICS AND COMPUTING↗

Advanced Hydrogen Turbine Development

Siemens has developed a roadmap to achieve the DOE goals for efficiency, cost reduction, and emissions through innovative approaches and novel technologies which build upon worldwide IGCC operational experience, platform technology, and extensive experience in G-class operating conditions. In Phase 1, the technologies and concepts necessary to achieve the program goals were identified for the gas turbine components and supporting technology areas and testing plans were developed to mitigate identified risks. Multiple studies were conducted to evaluate the impact in plant performance of different gas turbine and plant technologies. 2015 gas turbine technologies showed a significant improvement in IGCC plant efficiency, however, a severe performance penalty was calculated for high carbon capture cases. Thermodynamic calculations showed that the DOE 2010 and 2015 efficiency targets can be met with a two step approach. A risk management process was instituted in Phase 1 to identify risk and develop mitigation plans. For the risks identified, testing and development programs are in place and the risks will be revisited periodically to determine if changes to the plan are necessary. A compressor performance prediction has shown that the design of the compressor for the engine can be achieved with additional stages added to the rear of the compressor. Tip clearance effects were studied as well as a range of flow and pressure ratios to evaluate the impacts to both performance and stability. Considerable data was obtained on the four candidate combustion systems: diffusion, catalytic, premix, and distributed combustion. Based on the results of Phase 1, the premixed combustion system and the distributed combustion system were chosen as having the most potential and will be the focus of Phase 2 of the program. Significant progress was also made in obtaining combustion kinetics data for high hydrogen fuels. The Phase 1 turbine studies indicate initial feasibility of the advanced hydrogen turbine that meets the aggressive targets set forth for the advanced hydrogen turbine, including increased rotor inlet temperature (RIT), lower total cooling and leakage air (TCLA) flow, higher pressure ratio, and higher mass flow through the turbine compared to the baseline. Maintaining efficiency with high mass flow Syngas combustion is achieved using a large high AN2 blade 4, which has been identified as a significant advancement beyond the current state-of-the-art. Preliminary results showed feasibility of a rotor system capable of increased power output and operating conditions above the baseline. In addition, several concepts were developed for casing components to address higher operating conditions. Rare earth modified bond coat for the purpose of reducing oxidation and TBC spallation demonstrated an increase in TBC spallation life of almost 40%. The results from Phase 1 identified two TBC compositions which satisfy the thermal conductivity requirements and have demonstrated phase stability up to temperatures of 1850 C. The potential to join alloys using a bonding process has been demonstrated and initial HVOF spray deposition trials were promising. The qualitative ranking of alloys and coatings in environmental conditions was also performed using isothermal tests where significant variations in alloy degradation were observed as a function of gas composition. Initial basic system configuration schematics and working system descriptions have been produced to define key boundary data and support estimation of costs. Review of existing materials in use for hydrogen transportation show benefits or tradeoffs for materials that could be used in this type of applications. Hydrogen safety will become a larger risk than when using natural gas fuel as the work done to date in other areas has shown direct implications for this type of use. Studies were conducted which showed reduced CO{sub 2} and NOx emissions with increased plant efficiency. An approach to maximize plant output is needed in order to address the DOE turbine goal for 20-30% reduction of combined cycle cost from the baseline. A customer advisory board was instituted during Phase 1 to obtain important feedback regarding the future direction of the project. he technologies being developed for the Hydrogen Turbine will also be utilized, as appropriate, in the 2010 time frame engine and the FutureGen Plant. These new technologies and concepts also have the potential to accelerate commercialization of advanced coal-based IGCC plants in the U. S. and around the world, thereby reducing emissions, water use, solid waste production and dependence on scarce, expensive and insecure foreign energy supplies. Technology developments accomplished in Phase 1 provide a solid foundation for ensuring successful completion in Phase 2 and providing that the challenging program goals will be achieved.

03 NATURAL GAS↗

Review of LLNS Contractor Assurance System (CAS)

The focus of the review was to evaluate the LLNS Contractor Assurance System (CAS) system description document and implementation plan. The team reviewed the description document and the near and long term strategy improvement plans for the defined enhancements to the LLNS CAS. Review emphasis was placed on the CAS functional elements of Assessments, Issues Management, and Performance Measures, as well as the related CAS attributes of Requirements, Policies and Procedures, Risk Methodology, and Continuous Improvement. The approach taken by the team was to review the pertinent LLNL CAS documents, interview key CAS Process Owners, and interview selected line managers. The reviews were conducted in such a manner to achieve an understanding of the overall objective of the CAS and the processes within; and the soundness of the improvement plans for each of the elements/related attributes. The team then identified suggested recommendations for consideration as the overall implementation process for improvements move forward. The team appreciates the work that went into the development of the CAS Implementation Plan. It provided a meaningful starting place for this AIM team as it included sufficient information to quickly gain an understanding of the current LANS CAS processes and improvement initiatives. The team found that the July 2007 CAS Description Document did not provide a level of detail which would provide the reader an understanding of the elements and attributes of the CAS, how they are integrated, and how they help Managers manage the performance of their activities. Consider revising the document to include a level of detail that would provide value to the LLNS Board of Governors, LSO, and LLNL Managers. The team also found the description document to focus almost exclusively on describing the LLNS approach and initiatives associated with the 17 key attributes of Contract Clause H-4. While these discussions are appropriate for inclusion in the description document, by themselves, they do not clearly address the requirements and criteria in Attachment 1 and Appendix A to DOE 226.1A. It would seem that a comprehensive written CAS description document would address not only the expectations of Clause H-4, but that it would also address the requirements and criteria from DOE O 226.1A.

99 GENERAL AND MISCELLANEOUS↗

AN EXPERIMENTAL STUDY OF THE STABILITY OF VESSEL-SPANNING BUBBLES IN CYLINDRICAL & ANNULAR & OBROUND & AND CONICAL CONTAINERS

This report provides a summary of experiments that were performed by Fauske & Associates on the stability of vessel-spanning bubbles. The report by Fauske & Associates, An Experimental Study of the Stability of Vessel-Spanning Bubbles in Cylindrical, Annular, Obround and Conical Containers, is included in Appendix A. Results from the experiments confirm that the gravity yield parameter, Y{sub G}, correctly includes container size and can be applied to full-scale containers to predict the possibility of the formation of a stable vessel spanning bubble. The results also indicate that a vessel spanning bubble will likely form inside the STSC for KE, KW, and Settler sludges if the shear strengths of these sludges exceed 1820, 2080, and 2120 Pa, respectively. A passive mechanism installed in the STSC is effective at disrupting a rising sludge plug and preventing the sludge from plugging the vent filter or being forced out of the container. The Sludge Treatment Project for Engineered Container and Settler Sludge (EC/ST) Disposition Subproject is being conducted in two phases. Phase 1 of the EC/ST Disposition Subproject will retrieve the radioactive sludge currently stored in the K West (KW) Basin into Sludge Transport and Storage Containers (STSCs) and transport the STSCs to T-Plant for interim storage. Phase 2 of the EC/ST Disposition Subproject will retrieve the sludge from interim storage, treat and package sludge for disposal at the Waste Isolation Pilot Plant. The STSC is a cylindrical container; similar to previously used large diameter containers. A STSC (Figure 1) with a diameter of 58 inches will be used to transport KE and KW originating sludge (located in Engineered Containers 210, 220, 240, 250, and 260) to T-Plant. A STSC with an annulus (Figure 2) will be used to transport Settler Tank sludge, located in Engineered Container 230. An obround small canister design was previously considered to retrieve sludge from the basin. The obround design was selected in Small Canister Design Selection, PRC-STP-00052. However, the small canister was not selected for transporting the sludge. The STSC was selected for sludge loading and transport to T-Plant as discussed in Decision Report for Direct Hydraulic Loading of Sludge into Sludge Transport and Storage Containers, PRC-STP-00112. The STSC will be directly loaded with sludge as described in the Preliminary STP Container and Settler Sludge Process System Description and Material Balance, HNF-41051.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Revised International Standard for Gearboxes in Wind Turbine Systems

Gearbox and wind turbine design and application standards have contributed significantly to improvements in reliability over the past two decades. The International Electrotechnical Commission (IEC) 61400-4 standard of wind turbine gearbox design is currently being revised by a joint working group (JWG) of experts in IEC TC 88 (wind energy) and International Organization for Standardization (ISO) TC60 (gears) to further that effort. Experts from ISO TC4 (rolling bearings) and ISO TC28 (lubricants) have actively participated. This revision has implemented lessons learned from industry use of edition 1 since its publication in 2012. The main document, IEC 61400-4, was pared down to essential design requirements and application-specific recommendations along with a design verification framework. The JWG leveraged concurrent development of other standards, such as IEC 61400-8 on wind turbine structures, to replace edition 1 content. These are described along with how this works with the IEC Renewable Energy certification scheme for wind turbines (IECRE-WE). The JWG recognized the interest in maintaining informative parts of edition 1 including annexes on wind turbine architecture and loads, bearing and gear arrangements, bearing selection, lubrication system descriptions and lubricant performance recommendations. This information was retained in two technical reports: IEC/TR 61400-4-2 Lubrication and IEC/TR 61400-4-3 Explanatory Notes. Additionally, a technical specification, IEC/TS 61400-4-1, was drafted to provide a reliability calculation method for comparing different design options or conditions. Salient elements of these documents are described. All four documents were recently distributed for IEC/ISO review, ballot, and comment. Publication is expected in 2023.

gearbox↗

A Revised International Standard for Gearboxes in Wind Turbine Systems: Preprint

Gearbox and wind turbine design and application standards have contributed significantly to improvements in reliability over the past two decades. The International Electrotechnical Commission (IEC) 61400-4 standard of wind turbine gearbox design is currently being revised by a joint working group (JWG) of experts in IEC TC 88 (wind energy) and International Organization for Standardization (ISO) TC60 (gears) to further that effort. Experts from ISO TC4 (rolling bearings) and ISO TC28 (lubricants) have actively participated. This revision has implemented lessons learned from industry use of edition 1 since its publication in 2012. The main document, IEC 61400-4, was pared down to essential design requirements and application-specific recommendations along with a design verification framework. The JWG leveraged concurrent development of other standards, such as IEC 61400-8 on wind turbine structures, to replace edition 1 content. These are described along with how this works with the IEC Renewable Energy certification scheme for wind turbines (IECRE-WE). The JWG recognized the interest in maintaining informative parts of edition 1 including annexes on wind turbine architecture and loads, bearing and gear arrangements, bearing selection, lubrication system descriptions and lubricant performance recommendations. This information was retained in two technical reports: IEC/TR 61400-4-2 Lubrication and IEC/TR 61400-4-3 Explanatory Notes. Additionally, a technical specification, IEC/TS 61400-4-1, was drafted to provide a reliability calculation method for comparing different design options or conditions. Salient elements of these documents are described. All four documents were recently distributed for IEC/ISO review, ballot, and comment. Publication is expected in 2023.

ENGINEERING,WIND ENERGY↗

Long Reach Manipulator for PCV Repair at Fukushima Daiichi - 17082

Various Research and Development (R and D) efforts related to the retrieval of damaged fuel debris at Fukushima Daiichi Nuclear Power Plant in Japan have been made since the accident occurred in March 2011. Since 2012, the Primary Containment Vessel (PCV) Repair Project has been one of the major improvement tasks required in the reactor buildings in order to start fuel debris retrieval activities. The primary purpose of this project is to create a water boundary in the lower sections of the PCV using remote handling methods. A designated long reach remote manipulator for this project, called the Fukushima Repair Manipulator (FRM), has been developed to perform inspection, light demolition, and deployment of various tools to supply sealing material to fill the vent tubes as a part of the PCV Repair Project. The FRM is a single hydraulic manipulator which has 7 degrees of freedom, over 9 m reach, tool change capability and a payload of 50 kg at maximum reach. These features provide a safe, robust, efficient and allow for flexible operations in limited access and visibility around the operating area. This paper will provide a system description of this manipulator and planned remote operations for the PCV Repair Project. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

BiFeO(3): Synchrotron Radiation Structure Refinement And Magnetoelectric Geometry

Presently BiFeO{sub 3} focuses attention due to its multiferroic nature. This phase shows a highly distorted perovskite crystal structure, with R3c crystal symmetry. Details of the crystallographic structure are required input for a detailed explanation of its remarkable magnetoelectric properties. Present report contributes a high-resolution synchrotron radiation diffraction analysis of the BiFeO{sub 3} crystal structure. Single-phased sample was obtained by conventional solid-state reaction under bismuth atmosphere. XRD experiment was performed on beamline 2-1, Stanford Synchrotron Radiation Laboratory, with 12 keV X-rays. For data Rietveld processing, Fullprof software package was applied. Obtained cell parameters (in {angstrom}, hexagonal system description) were a = 5.57414(4); c = 13.85882(12). Group-theoretical analysis of BiFeO{sub 3} linear magnetoelectric tensor is presented. Only transverse effect is allowed by symmetry. Axial-symmetry polycrystal ceramics cannot show linear magnetoelectric coupling.

36 MATERIALS SCIENCE↗

Wave packet dynamics in various two-dimensional systems: A unified description

In this article we present an exact and unified description of wave packet dynamics in various 2D systems in the presence of a transverse magnetic field. We consider an initial minimum-uncertainty Gaussian wave packet and find that its long-term dynamics displays the universal phenomena of spontaneous collapse and quantum revival. We estimate the timescales associated with these phenomena based on very general arguments for various materials, whose carrier dynamics is described either by the Schrödinger equation or by the Dirac equation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

First experiment with the double solenoid RIBRAS system

A description of the double solenoid system (RIBRAS) operating since 2004 in one of the beam lines of the Pelletron Laboratory of the Institute of Physics of the University of Sao Paulo is presented. The recent installation of the secondary scattering chamber after the second solenoid is reported and the first experiment in RIBRAS using both solenoids is described.

43 PARTICLE ACCELERATORS↗

Percolation theory and quantum critical systems: A new description of the critical behavior in Ce(Ru{sub 0.24}Fe{sub 0.76}){sub 2}Ge{sub 2}

The onset of ordering in quantum critical systems is characterized by a competition between the Kondo shielding of magnetic moments and the ordering of these moments. We show how a distribution of Kondo shielding temperatures—resulting from chemical doping—leads to critical behavior whose main characteristics are given by percolation physics. With the aid of Monte Carlo computer simulations, we are able to infer the low temperature part of the distribution of shielding temperatures in heavily doped quantum critical Ce(Ru{sub 0.24}Fe{sub 0.76}){sub 2}Ge{sub 2}. Based on this distribution, we show that the ordering dynamics—such as the growth of the correlation length upon cooling—can be understood by the spawning of magnetic clusters. Our findings explain why the search for universal exponents in quantum critical systems has been unsuccessful: the underlying percolation network associated with the chemical doping of quantum critical systems has to be incorporated in the modeling of these quantum critical systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Hydrodynamic description for ballistic annihilation systems

The problem of the validity of a hydrodynamic description for a system in which there are no collisional invariants is addressed. Hydrodynamic equations have been derived and successfully tested against simulation data for a system where particles annihilate with a probability p, or collide elastically otherwise. The response of the system to a linear perturbation is analyzed as well.