Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

System calibration of the 1.4 GHz and 5 GHz radiometers for soil moisture remote sensing

Two microwave radiometers at the frequencies of 1.4 GHz and 5 GHz were mounted on a mobile tower and used for a remote sensing of soil moisture experiment at a Beltsville Agriculture Research Center test site. The experiment was performed in October 1979 over both bare field and fields covered with grass, soybean, and corn. The calibration procedure for the radiometer systems which forms the basis of obtaining the final radiometric data product is described. It is estimated from the calibration results that the accuracy of the 1.4 GHz radiometric measurements is about + or - 3 K. The measured 5 GHz brightness temperatures over bare fields with moisture content greater than 10 percent by dry weight are about 8 K lower than those taken simultaneously at 1.4 GHz. This could be due to either (1) a 5 GHz antenna side lobe seeing the cold brightness of the sky, or (2) the thermal microwave emission from a soil being less sensitive to surface roughness at 5 GHz than at 1.4 GHz.

Wang, J.↗

Smart power supply calibration system

This paper details the development of an automated procedure to conduct calibrations of power supplies at Jet Propulsion Laboratory, California Institute of Technology (JPL). The fundamentals of power supply calibrations is given, and discussion on the method by which this custom software handles that calibration. Additionally, this technique provides real time uncertainty quantification of the calibrations. This automated system has demonstrated a time savings over existing automated techniques in use today.

Umansky, Brandon M.↗

Multi-Axis Accelerometer Calibration System

A low-cost, portable, and simplified system has been developed that is suitable for in-situ calibration and/or evaluation of multi-axis inertial measurement instruments. This system overcomes facility restrictions and maintains or improves the calibration quality for users of accelerometer-based instruments with applications in avionics, experimental wind tunnel research, and force balance calibration applications. The apparatus quickly and easily positions a multi-axis accelerometer system into a precisely known orientation suitable for in-situ quality checks and calibration. In addition, the system incorporates powerful and sophisticated statistical methods, known as response surface methodology and statistical quality control. These methods improve calibration quality, reduce calibration time, and allow for increased calibration frequency, which enables the monitoring of instrument stability over time.

Finley, Tom↗

The LED calibration systems for the mDOM and D-Egg sensor modules of the IceCube Upgrade: Design, production, testing and use in module calibration

The IceCube Neutrino Observatory, instrumenting about 1 km 3 of deep, glacial ice at the geographic South Pole, is due to be enhanced with the IceCube Upgrade. The IceCube Upgrade, to be deployed during the 2025/26 Antarctic summer season, will consist of seven new strings of photosensors, densely embedded near the bottom center of the existing array. Aside from a world-leading sensitivity to neutrino oscillations, a primary goal is the improvement of the calibration of the optical properties of the instrumented ice. This calibration will be applied to the entire archive of IceCube data, improving the angular and energy resolution of the detected neutrino events. For this purpose, the Upgrade strings include a host of new calibration devices. Aside from dedicated calibration modules, several thousand LED flashers have been incorporated into the photosensor modules. We describe the design, production, and testing of these LED flashers before their integration into the sensor modules as well as the use of the LED flashers during lab testing of assembled sensor modules.

Analogue electronic circuits↗

Preliminary Calibration System Report for High-Temperature Irradiation-Resistant Thermocouples

An established calibration procedure is presented for the high-temperature irradiation-resistant thermocouple (HTIR-TC). Standard calibration curves for both an individual (i.e. case by case basis) and common calibrations is shown. The error limits within ±3 σ are ±1% for the individual calibrations and ±2% for the common calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Traceable Ground to On-Orbit Radiometric Calibration System for the Solar Reflective Wavelength Region

This paper describes the combination of a Mie scattering spectral BSDF and BTDF albedo standard whose calibration is traceable to the NIST SIRCUS Facility or the NIST STARR II Facility. The Space-based Calibration Transfer Spectroradiometer (SCATS) sensor uses a simple, invariant optical configuration and dedicated narrow band spectral channel modules to provide very accurate, polarization-insensitive, stable measurements of earth albedo and lunar disk albedo. Optical degradation effects on calibration stability are eliminated through use of a common optical system for observations of the Sun, Earth, and Moon. The measurements from space would be traceable to SI units through preflight calibrations of radiance and irradiance at NIST's SIRCUS facility and the invariant optical system used in the sensor. Simultaneous measurements are made in multiple spectral channels covering the solar reflective wavelength range of 300 nm to 2.4 microns. The large dynamic range of signals is handled by use of single-element, highly-linear detectors, stable discrete electronic components, and a non imaging optical configuration. Up to 19 spectral modules can be mounted on a single-axis drive to give direct pointing at the Earth and at least once per orbit view of the Sun and Moon. By observing the Sun on every orbit, the most stringent stability requirements of the system are limited to short time periods. The invariant optical system for both radiance and irradiance measurements also give excellent transfer to-orbit SI traceability. Emerging instrumental requirements for remotely sensing tropospheric trace species have led to a rethinking by some of the paradigm for Systeme International d'Unites (SI) traceability of the spectral irradiance and radiance radiometric calibrations to spectral albedo (sr(exp -1)) which is not a SI unit. In the solar reflective wavelength region the spectral albedo calibrations are tied often to either the spectral albedo of a solar diffuser or the Moon. This new type of Mie scattering diffuser (MSD) is capable of withstanding high temperatures, and is more Lambertian than Spectralon(tm). It has the potential of covering the entire solar reflective wavelength region. Laboratory measurements have shown that the specular reflectance component is negligible, and indicate that internal absorption by multiple scattering is small. This MSD, a true volume diffuser, exhibits a high degree of radiometric stability which suggests that measurements at the National Institute of Standards and Technology (NIST) could provide a spectral albedo standard. Measurements have been made of its radiometric stability under a simulated space environment of high energy gamma rays, high energy protons, and UV radiation from ambient down to the vacuum ultraviolet H Lyman alpha at 121.6 nm for its eventual use in space as a solar diffuser.

Heath, Donald F.↗

Broadband Stability of the Habitable Zone Planet Finder Fabry–Pérot Etalon Calibration System: Evidence for Chromatic Variation

The comblike spectrum of a white light–illuminated Fabry–Pérot etalon can serve as a cost-effective and stable reference for precise Doppler measurements. Understanding the stability of these devices across their broad (hundreds of nanometers) spectral bandwidths is essential to realizing their full potential as Doppler calibrators. However, published descriptions remain limited to small bandwidths or short time spans. We present an ∼6 month broadband stability monitoring campaign of the Fabry–Pérot etalon system deployed with the near-infrared Habitable Zone Planet Finder (HPF) spectrograph. We monitor the wavelengths of each of ∼3500 resonant modes measured in HPF spectra of this Fabry–Pérot etalon (free spectral range = 30 GHz, bandwidth = 820–1280 nm), leveraging the accuracy and precision of an electro-optic frequency comb reference. These results reveal chromatic structure in the Fabry–Pérot mode locations and their evolution with time. We measure an average drift on the order of 2 cm s{sup –1} day{sup −1}, with local departures up to ±5 cm s{sup –1} day{sup −1}. We discuss these behaviors in the context of the Fabry–Pérot etalon mirror dispersion and other optical properties of the system and the implications for the use of similar systems for precise Doppler measurements. Our results show that this system supports the wavelength calibration of HPF at the ≲10 cm s{sup −1} level over a night and the ≲30 cm s{sup −1} level over ∼10 days. Our results also highlight the need for long-term and spectrally resolved study of similar systems that will be deployed to support Doppler measurement precision approaching ∼10 cm s{sup −1}.

42 ENGINEERING↗

Evaluation of anomalies observed on film from S-190A flight system calibration test

Due to a persistent problem of scratched film from testing of the Skylab S-190A system, a series of tests were designed to identify the cause of the film scratching. The procedures followed in this test for pretest handling and packaging of the film, the makeup of the rolls for processing, and the results of the processed film evaluation are reported.

Bourque, P. F.↗