Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “subsurface contamination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Inertia-induced mixing and reaction maximization in laminar porous media flows

Solute transport and biogeochemical reactions in porous and fractured media flows are controlled by mixing, as are subsurface engineering operations such as contaminant remediation, geothermal energy production, and carbon sequestration. Porous media flows are generally regarded as slow, so the effects of fluid inertia on mixing and reaction are typically ignored. Here, we demonstrate through microfluidic experiments and numerical simulations of mixing-induced reaction that inertial recirculating flows readily emerge in laminar porous media flows and dramatically alter mixing and reaction dynamics. An optimal Reynolds number that maximizes the reaction rate is observed for individual pore throats of different sizes. This reaction maximization is attributed to the effects of recirculation flows on reactant availability, mixing, and reaction completion, which depend on the topology of recirculation relative to the boundary of the reactants or mixing interface. Recirculation enhances mixing and reactant availability, but a further increase in flow velocity reduces the residence time in recirculation, leading to a decrease in reaction rate. The reaction maximization is also confirmed in a flow channel with grain inclusions and randomized porous media. Interestingly, the domain-wide reaction rate shows a dramatic increase with increasing Re in the randomized porous media case. This is because fluid inertia induces complex three-dimensional flows in randomized porous media, which significantly increases transverse spreading and mixing. This study shows how inertial flows control reaction dynamics at the pore scale and beyond, thus having major implications for a wide range of environmental systems.

Chen, Michael A. (ORCID:0000000294614710)↗

Multimodal Instrument Platform for High-Pressure MAS-NMR and IR Spectroscopic Interrogation

This project developed and tested a high-pressure (HP) flow-through instrument platform that combines HP- magic angle spinning nuclear magnetic resonance (MAS-NMR) spectroscopy for interrogating reactivity at interfaces between solid materials and HP fluids with HP- infrared (IR) spectroscopy for measuring fluid composition. Solid-fluid interfacial reactivity is usually dependent on concentrations of species within the fluid; thus, knowledge of the fluid composition measured by IR is critical to understanding solid-fluid interfacial reactivity probed by NMR. This new system adds to PNNL’s core capabilities in Chemical and Material Sciences to support fundamental programs in catalysis, interfacial molecular science, and geosciences, as well as in Earth and Biological Sciences to support energy production and storage, efforts to mitigate the impacts energy production systems, attenuation of contaminant plumes, and design of subsurface engineered systems for energy production and waste disposal.

36 MATERIALS SCIENCE↗

Predictive Integrated Stratigraphic Modeling Report, Center-wide Per- and Polyfluoroalkyl Substances, Potential Release Location 237, Kennedy Space Center, FL

The National Aeronautics and Space Administration (NASA) is investigating the occurrence of per- and polyfluoroalkyl substances (PFAS) Center-wide at Kennedy Space Center (KSC), Merritt Island, Florida (Figure 1-1) as Potential Release Location 237. AECOM Technical Services, Inc. (AECOM) conducted investigation activities in 2020 and 2021 to develop a better understanding of the fate and transport of PFAS in groundwater and surface water at KSC center-wide using PRedictive Integrated Stratigraphic Modeling (PRISM). PRISM uses best practices from the fields of geology, hydrology, and chemistry to acquire a holistic understanding of the subsurface and more accurately predict contaminant migration pathways. Based on the potential magnitude (frequency and areal distribution) of PFAS impacts at KSC, the analyses described herein were designed to provide tools to address the unique behavior of PFAS chemicals.

PFAS↗

Calcium carbonate minerals as scavengers of metals and radionuclides: Their role in natural attenuation and remediation

Calcium carbonates (CaCO3) are ubiquitous naturally occurring minerals in subsurface sediments. Calcium carbonate coatings are common in many terrestrial environments and are known to coat a variety of reactive mineral surfaces in soils and sediments, altering their reactivity and chemical behavior. For these reasons, contaminant interactions with CaCO3 minerals are relevant to contaminant fate and transport. Significant advancements have been made recently toward identifying relevant contaminant (e.g., U, I, and Cr) attenuation mechanisms, which may also serve as a basis for in situ remediation strategies. Hence, the objective of this review paper is to 1) describe the state-of-knowledge of calcium carbonate minerals as universal scavengers of metals and radionuclides; 2) provide a state of the science of how calcium carbonate interactions affect contaminant fate and transport in the subsurface environmental systems; and 2) provide insights on the use of calcium carbonate natural attenuation mechanisms and their application to the remediation of complex sites. Knowledge gaps are also identified that, when closed, can advance the use of carbonate minerals for in situ remedy applications.

Qafoku, Nikolla↗

The Effects of Contaminant-Aging on Decontamination Efficacy for Rapid Remediation of Concrete Surfaces - 20412

Understanding the relationship between decontamination efficacy and contaminant aging is imperative for developing effective remediation strategies following a large-scale contamination event. Non-destructive decontamination of concrete following a contamination incident becomes more difficult with increased time between contamination and decontamination because contaminants may chemically bind to concrete and/or penetrate into the concrete subsurface. In this work, we evaluated the decontamination efficacy of two decontamination methods on concrete samples contaminated with soluble Cesium-137 (Cs-137) and silica particles with 0.5 μm and 2 μm diameters. Concrete samples were aged between 1 and 59 days, with half of the coupons receiving 1 mL of artificial rainwater about once every three days. After aging, coupons were either decontaminated or analyzed to determine contaminant penetration depths. Coupons were decontaminated with 0.1 M Potassium Chloride (KCI) solution applied either by flowing solution across the contaminated coupon face or non-destructive power washing. Contaminant depth profiles were created by removing the top surface of the coupon at least 15 times, measuring the activity in each removed layer, normalizing the total activity removed to the measured decontamination efficacy following the last layer removal, and determining the penetration thickness using the coupon dimensions, bulk density, and mass of material removed for each layer. Pressurized washing effectively removed particles, but not soluble cesium, despite the majority of Cs-137 being located within the first millimeter of the subsurface. Soluble cesium removal by flowing 0.1 M KCI solution across the contaminated surface dropped to less than 12% within the first ten days. This drop in Cs-137 removal efficacy occurred within the first five days for coupons experiencing artificial rainfall events. Flowing 0.1 M KCI solution across the contaminated face was ineffective at removing particles, likely because particles had localized in surface depressions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Emergence of Unstable Focused Flow Induced by Variable‐Density Flows in Vertical Fractures

Abstract Fluids with different densities often coexist in subsurface fractures and lead to variable‐density flows that control subsurface processes such as seawater intrusion, contaminant transport, and geologic carbon sequestration. In nature, fractures have dip angles relative to gravity, and density effects are maximized in vertical fractures. However, most studies on flow and transport through fractures are often limited to horizontal fractures. Here, we study the mixing and transport of variable‐density fluids in vertical fractures by combining three‐dimensional (3D) pore‐scale numerical simulations and visual laboratory experiments. Two miscible fluids with different densities are injected through two inlets at the bottom of a fracture and exit from an outlet at the top of the fracture. Laboratory experiments show the emergence of an unstable focused flow path, which we term a “runlet.” We successfully reproduce the unstable runlet using 3D numerical simulations and elucidate the underlying mechanisms triggering the runlet. Dimensionless number analysis shows that the runlet instability arises due to the Rayleigh‐Taylor instability (RTI), and flow topology analysis is applied to identify 3D vortices that are caused by the RTI. Even under laminar flow regimes, fluid inertia is shown to control the runlet instability by affecting the size and movement of vortices. Finally, we confirm the emergence of a runlet in rough‐walled fractures. Since a runlet dramatically affects fluid distribution, residence time, and mixing, the findings in this study have direct implications for the management of groundwater resources and subsurface applications.

Environmental Sciences & Ecology↗

Effects of Desiccation and Freezing on Microbial Ionizing Radiation Survivability: Considerations for Mars Sample Return

Increasingly, national space agencies are expanding their goals to include Mars exploration with sample return. To better protect Earth and its biosphere from potential extraterrestrial sources of contamination, as set forth in the Outer Space Treaty of 1967, international efforts to develop planetary protection measures strive to understand the danger of cross-contamination processes in Mars sample return missions. We aim to better understand the impact of the martian surface on microbial dormancy and survivability. Radiation resistance of microbes is a key parameter in considering survivability of microbes over geologic times on the frigid, arid surface of Mars that is bombarded by solar and galactic cosmic radiation. We tested the influence of desiccation and freezing on the ionizing radiation survival of six model microorganisms: vegetative cells of two bacteria (Deinococcus radiodurans, Escherichia coli) and a strain of budding yeast (Saccharomyces cerevisiae); and vegetative cells and endospores of three Bacillus bacteria (B. subtilis, B. megaterium, B. thuringiensis). Desiccation and freezing greatly increased radiation survival of vegetative polyploid microorganisms when applied separately, and when combined, desiccation and freezing increased radiation survival even more so. Thus, the radiation survival threshold of polyploid D. radiodurans cells can be extended from the already high value of 25 kGy in liquid culture to an astonishing 140 kGy when the cells are both desiccated and frozen. However, such synergistic radioprotective effects of desiccation and freezing were not observed in monogenomic or digenomic Bacillus cells and endospores, which are generally sterilized by 12 kGy. This difference is associated with a critical requirement for survivability under radiation, that is, repair of genome damage caused by radiation. Deinococcus radiodurans and S. cerevisiae accumulate similarly high levels of the Mn antioxidants that are required for extreme radiation resistance, as do endospores, though they greatly exceed spores in radioresistance because they contain multiple identical genome copies, which in D. radiodurans are joined by persistent Holliday junctions. We estimate ionizing radiation survival limits of polyploid DNA-based life-forms to be hundreds of millions of years of background radiation while buried in the martian subsurface. Our findings imply that forward contamination of Mars will essentially be permanent, and backward contamination is a possibility if life ever existed on Mars.

59 BASIC BIOLOGICAL SCIENCES↗

Sediment and groundwater metagenomes from subsurface microbial communities from the Oak Ridge National Laboratory Oak Ridge Reservation, Oak Ridge, Tennessee, USA

We report 26 subsurface sediment and 9 groundwater metagenomes from the Oak Ridge Reservation at Oak Ridge, TN, USA. Samples were collected from various depths and phases (attached vs planktonic) to study subsurface microbial metabolism, the effect of contamination on microbial communities, and differences across groundwater and sediment microbial communities.

Lui, Lauren M↗

OB200-DV-1 Treatability Testing: Final Results

The Hanford Site in Washington state previously generated plutonium for nuclear weapons. During operations, radionuclide byproducts and chemical process fluids were intentionally and/or unintentionally released to the subsurface, resulting in more than 800 contaminated waste sites across the Central Plateau, where historical chemical separations and waste management activities took place. As the Hanford Site mission transitioned from operations to site cleanup, remediation of the vadose zone and groundwater became a priority. However, given the depth of the unsaturated zone contamination above the groundwater, the unique nature of the waste, and the continuing impacts on groundwater quality, technologies needed to be identified and evaluated for in situ remediation in the deep vadose zone (DVZ). A laboratory treatability study has been completed to evaluate site-relevant effectiveness for nine in situ technologies that may be used to treat continuing sources of contaminants in specific areas of the Central Plateau waste sites that are grouped into the 200-DV-1 Operable Unit (OU). The 200-DV-1 OU was established in 2010 to address 43 Central Plateau waste sites with complex DVZ remediation challenges. Eight of these technologies were identified through a prescreening effort that evaluated remedial technologies potentially applicable to DVZ contamination in the Central Plateau . These eight technologies were selected for further study based on site specific knowledge gaps about their effectiveness. A ninth technology was added to the treatability study based on new information from separate laboratory investigations (conducted following the prescreening effort) demonstrating the technology’s potential effectiveness (see Section 1.2 for more information) and value for inclusion in the treatability study.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Carbon Tetrachloride Degradation Results for 200-ZP-1 Operable Unit

Carbon tetrachloride (CT) contamination in the 200-ZP-1 Operable Unit (OU) at the Hanford Site originated from large-volume discharges to the subsurface during plutonium production operations between 1955 and 1973. Contamination migrated through more than 70 meters of unsaturated sediment to reach the underlying unconfined aquifer, where it persists as a large and complex groundwater plume. The 200-ZP-1 OU Record of Decision (ROD) requires that groundwater CT concentrations be reduced to 3.4 µg/L within 125 years. Current groundwater modeling projections estimate that the existing pump-and-treat, even when combined with monitored natural attenuation (specifically hydrolysis), will not achieve this target within the designated timeframe. A fundamental contributor to this shortfall is the extremely slow rate of CT hydrolysis under Hanford aquifer conditions, which has been estimated to have a half-life of 630 years. If faster-acting biotic and abiotic degradation processes are operating within the aquifer, their contribution to CT mass reduction could have a meaningful impact. However, site-specific measurements of these processes and their rates have not previously been performed. This report documents the results of a two-phase laboratory investigation designed to characterize and quantify the capacity of site-specific 200-ZP-1 OU sediments and groundwater to support natural attenuation of CT through biotic and abiotic pathways. In this context, degradation capacity is defined as the intrinsic potential of the subsurface matrix to transform CT under optimized, controlled conditions. System capacity is evaluated in two ways: (1) as rate-limited capacity, which establishes the maximum kinetic velocity of CT transformation and is measured using half-lives and first order rate constants; and (2) as mass limited capacity, which defines the total contaminant mass the batch experimental system can degrade before reactants are exhausted, representing the maximum amount of contaminant the microbial community and reactive mineral phases can transform under the experimental conditions.

abiotic degradation↗

Zero-Valent Iron Permeable Reactive Barrier to Remediate Volatile Organic Compounds in Groundwater - 20209

The US DOE-SRS, the US EPA, and the South Carolina Department of Health and Environmental Control determined it was appropriate to perform a non-time critical removal action at the P-Area Groundwater Operable Unit at the SRS to reduce the mass and downgradient transport of trichloroethylene in the P-Area groundwater plume. Contaminated groundwater discharges to a nearby stream, Steel Creek, within the SRS boundaries, resulting in trichloroethylene concentrations above the maximum contaminant level. Impact to surface water is limited in areal extent and supported by recently collected characterization data. The P-Area Groundwater Operable Unit encompasses the groundwater beneath an industrial area within SRS, P Area, where the P-Reactor once operated. The boundaries of the P-Area Groundwater Operable Unit extend northwest to Steel Creek, northeast toward PAR Pond, and southeast to Meyers Branch. Groundwater in the Upper Three Runs Aquifer of the P-Area Groundwater Operable Unit has been impacted by reactor and facility operations between 1954 and 1991, including tritium and volatile organic compounds. The P-Area surface units contributing to groundwater contamination were remediated as part of the P-Area Operable Unit in 2011. The P-Reactor closure is one of the first of its kind in the DOE Complex and is one of only a few full-sized production reactors in the US to undergo completion of final closure activities. The nature and extent of groundwater contamination was determined using a variety of investigative approaches such as groundwater monitoring wells, direct-push technology, and surface water samples. Groundwater contamination associated with trichloroethylene is primarily exhibited in a narrow plume that extends from the source area at P-Reactor and west to Steel Creek. Maximum contaminant level exceedances in groundwater occur over an area of ∼6.9 hectares for trichloroethylene with concentrations as high as 7.7 milligrams per liter. To the west of the P-Area facility area, the trichloroethylene groundwater plume is controlled by a buried geologic feature, assumed to be an old stream bed, that further narrows the groundwater plume in what has been designated as the 'neck area.' This narrowing of the groundwater plume provides an ideal location for a treatment barrier. The non-time critical removal action alternative chosen is to install a zero-valent iron permeable reactive barrier within the neck area of the trichloroethylene groundwater plume, perpendicular to groundwater flow direction. This technology will provide a treatment barrier that will reduce trichloroethylene groundwater concentrations by 90% and has an anticipated useful life of at least 25 years. A pre-design investigation was performed in the neck area to confirm site lithology, hydrogeology, geochemistry, and extent of trichloroethylene contamination prior to a final design. A treatability study, conducted as part of the pre-design investigation, indicated that the subsurface and groundwater in the PArea Groundwater Operable Unit is compatible with the zero-valent iron and will not lead to excessive buildup from mineralization/precipitation or biofouling. Probabilistic modeling was conducted using field and laboratory data to determine the expected performance of the zero-valent iron permeable reactive barrier. The model simulations indicated that a 3.81-centimeter thick barrier would provide greater than 90% reduction of trichloroethylene groundwater concentration. The final design of the zero-valent iron permeable reactive barrier is a barrier that will extend 80.5 linear meters in a 'zigzag' orientation to best transect the trichloroethylene plume and account for varying groundwater flow. The barrier will be installed from 13.7 meters below ground surface to 41.1 meters below ground surface for 65.8 linear meters and from 13.7 meters below ground surface to 36.6 meters below ground surface for 14.6 linear meters, the base of which is 'keyed' into a low permeability zone. The barrier is designed to a thickness of 10.2 centimeters, which was determined to reduce the trichloroethylene groundwater concentrations by greater than 90% with a safety factor of 2.67. A total of approximately 689 metric tons of zero-valent iron will be injected through 22 injection wells spaced 3.66 meters apart, using guar to suspend the zero-valent iron. Zero-valent iron permeable reactive barrier construction will be monitored through 23 installed resistivity receivers offset 7.32 meters from the zerovalent iron permeable reactive barrier. The zero-valent iron will be energized with a low-voltage 100 Hertz signal during injection and will be monitored using the resistivity receivers to ensure complete coalescence of the zero-valent iron permeable reactive barrier. The zero-valent iron was sized to have a hydraulic conductivity greater than the natural subsurface, thus promoting groundwater flow through the barrier. As contaminated groundwater contacts the zero-valent iron, volatile organic compounds, including trichloroethylene, are immediately degraded to harmless compounds such as ethylene. The performance of the zero-valent iron permeable reactive barrier will be monitored using three upgradient monitoring well clusters, six downgradient monitoring well clusters, and four in-wall monitoring wells. The in-wall monitoring wells will indicate immediate reduction of trichloroethylene mass in the groundwater and allow analyses of the zero-valent iron permeable reactive barrier health. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Calibration and Uncertainty Estimation Using the Ensemble Kalman Filter with a Large Subsurface Flow and Transport Model - 20321

At routinely monitored groundwater contamination sites, periodically measured environmental conditions such as groundwater levels and contaminant concentrations are used to inform and confirm a conceptual site model (CSM) and guide the development and calibration of a numerical groundwater flow and transport model. The calibration of groundwater flow and transport models after each measurement (sampling) event can illuminate deficiencies in a CSM, identify areas where additional monitoring is warranted, and predict the behavior of the system to guide decision making. However, manual and automated (e.g. PEST) model calibration tools can be time-consuming and computationally expensive to implement after each sampling event. Perhaps as a result, such calibration tools generally utilize all available monitoring data simultaneously rather than sequentially assimilating monitoring data one sampling event at a time as the results from sampling become available. A more real-time data assimilation approach may reduce parameter uncertainty, quantify the value of additional monitoring data, and produce a usable model more quickly and with less effort. To mitigate the potential time-consuming aspects of manual and widely applied automated calibration techniques, a data assimilation algorithm called the ensemble Kalman filter (EnKF) was evaluated as a relatively efficient method of model calibration and uncertainty assessment via the sequential integration of monitoring data into a model. The EnKF was able to successfully and efficiently assimilate monitoring and modeling data to calibrate a complex flow and transport model at a real-world site with significant subsurface heterogeneity, uncertainty, and 12 years of monitoring data (over 4,000 individual measurements of groundwater levels and over 2,500 measurements of contaminant concentrations). Starting with an uncalibrated model data from annual sampling events were sequentially assimilated, and the resultant predication errors and estimated parameter uncertainties were tracked. After all monitoring data were assimilated, both flow and transport residuals at the end of the EnKF process were comparable to those produced via a concurrent PEST calibration effort but required fewer model simulations. Both uncertainty and prediction errors decreased over time. In a real-time application, the adequacy of the model could be assessed after each sampling event. The benefits of such a real-time approach to utilizing monitoring data include reduced costs (in the form of model updates or site characterization efforts), early flagging of possible errors in the CSM, and a reduced risk of overfitting and corresponding increased confidence in model predictions. This tool may be particularly useful compared to other calibration techniques (e.g. manual, PEST) when model runtimes are long, calibration parameters are many, or parameter uncertainty is large. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of Dose- and Risk-Based Groundwater Cleanup Levels for Low Energy Beta Radioisotopes

Low-energy beta-emitting radionuclides that were released historically during reactor operations and plutonium separations activities at some U.S. Department of Energy sites have migrated into the groundwater, forming contaminant plumes that are subject to federally regulated remediation actions. At the Hanford Site, the low-energy beta-emitting radionuclides include iodine-129, technetium-99, chlorine-36, carbon-14, and tritium (H-3). All are highly mobile in the subsurface, and except for tritium, and have very long half-lives—thousands to millions of years. The geochemistry and transport behavior of these contaminants in the subsurface present significant challenges for remediation of groundwater to federal drinking water standards (DWS)—the appropriate or relevant and applicable requirements (ARARs) for cleanup. For some of the low-energy beta-emitter contaminants, particularly iodine-129, cleanup and restoration of groundwater to DWS may not be attainable within a reasonable timeframe using currently available treatment technologies.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Influence of physical and chemical hydrology on bioremediation of a U-contaminated aquifer informed by reactive transport modeling incorporating 238 U/ 235 U ratios

Microbially-catalyzed reductive immobilization of aqueous uranium (U) as a solid phase has been proposed as a U remediation technique. Both laboratory and field experiments have demonstrated that this reduction reaction alters the 238 U/ 235 U ratio, producing a 238 U-enriched U(IV) solid. In contrast, other major U reactive transport processes fractionate these isotopes much less. This suggests the potential to quantify the extent of bioreduction occurring in groundwater containing U using the 238 U/ 235 U ratio, which would substantially improve upon current practices largely relying on U concentration measurements alone. Current reactive transport models for uranium dynamics include only concentration measurements, which are strongly influenced by highly coupled reactive transformation and aqueous transport processes. The complex physical and chemical behavior of U potentially compromises such quantitative analysis of U storage and release. Here we report the first numerical reactive transport model which explicitly incorporates variations in the 238 U/ 235 U ratio of U and demonstrates improved interpretation of the principal chemical reactions and groundwater transport processes affecting the subsurface mobility and distribution of this widespread contaminant. Recent U bioreduction studies performed in a contaminated aquifer in Rifle, Colorado, USA applied Rayleigh distillation models to interpret U stable isotope fractionation observed as a result of acetate amendment. These simplified models were unable to resolve the spatiotemporal pattern of U isotope fractionation recorded in the aqueous solutes. Here, we employ the multi-component, isotope-enabled CrunchTope reactive transport software to interpret these measured U isotope ratios, and demonstrate accurate reproduction of observed trends in both geochemistry and 238 U/ 235 U ratios for two consecutive years of field experiments. Overall, our results indicate that accurately modeling both the U concentration and isotope ratio distributions greatly constrains the parameter space of the model. We find that the transport properties of U in the Rifle aquifer are governed by the presence of low-permeability regions, which the isotopes are uniquely sensitive to. When U reduction is spatially constrained by these low-permeability regions, the shift in the 238 U/ 235 U ratio becomes more muted. Accurate modeling of observed U isotope ratios thus provides a powerful means to better understand bioremediation, and the current study serves to advance the application of this novel method.

238U/235U↗

Deep Learning for Simultaneous Inference of Hydraulic and Transport Properties

Abstract Identification of a heterogeneous conductivity field and reconstruction of a contaminant release history are key aspects of subsurface remediation. These two goals are achieved by combining model predictions with sparse and noisy hydraulic head and concentration measurements. Solution of this inverse problem is notoriously difficult due to, in part, high dimensionality of the parameter space and high computational cost of repeated forward solves. We use a convolutional adversarial autoencoder (CAAE) to parameterize a heterogeneous non‐Gaussian conductivity field via a low‐dimensional latent representation. A three‐dimensional dense convolutional encoder‐decoder (DenseED) network serves as a forward surrogate of the flow and transport model. The CAAE‐DenseED surrogate is fed into the ensemble smoother with multiple data assimilation (ESMDA) algorithm to sample from the Bayesian posterior distribution of the unknown parameters, forming a CAAE‐DenseED‐ESMDA inversion framework. The resulting CAAE‐DenseED‐ESMDA inversion strategy is used to identify a three‐dimensional contaminant source and conductivity field. A comparison of the inversion results from CAAE‐ESMDA with physical flow and transport simulator and from CAAE‐DenseED‐ESMDA shows that the latter yields accurate reconstruction results at the fraction of the computational cost of the former.

Zhou, Zitong↗

Understanding Discrete Fracture Networks Through Spectral Graph Theory

Discrete Fracture Network models (DFNs) are used to simulate fluid flow and particle transport through fracture networks in low permeability rock. Understanding these processes are essential in many subsurface applications, such as environmental restoration of contaminated fractured media, CO 2 sequestration, detection of low-level nuclear tests, and hydrocarbon extraction. Compared with other models, DFNs allow for incorporation of a wider range of network characteristics but have substantially greater computation cost. These networks can be represented with graphs, allowing the use of graph theory tools to study the networks. I used Python to simulate flow and transport on a range of DFNs and analyzed these networks using methods from network analysis and spectral graph theory. My purpose was to find ways to gain insight about flow and transport on DFNs using these graph representations, bypassing the computationally intensive meshing typically required. My work is still in progress, but I have discovered several interesting trends and patterns that I believe could be useful towards my goal. If I am able to bring these results to fruition, they will aid subsurface geologists in extracting flow and transport information about fracture networks more efficiently.

54 ENVIRONMENTAL SCIENCES↗

Mechanical Abrasion as a Low Cost Technique for Contamination-Free Sample Acquisition from a Category IVA Clean Platform

The proposed Mars Sample Transfer Chain Architecture provides Planetary Protection Officers with clean samples that are required for the eventual release from confinement of the returned Martian samples. At the same time, absolute cleanliness and sterility requirement is not placed of any part of the Lander (including the deep drill), Mars Assent Vehicle (MAV), any part of the Orbiting Sample container (OS), Rover mobility platform, any part of the Minicorer, Robotic arm (including instrument sensors), and most of the caching equipment on the Rover. The removal of the strict requirements in excess of the Category IVa cleanliness (Pathfinder clean) is expected to lead to significant cost savings. The proposed architecture assumes that crosscontamination renders all surfaces in the vicinity of the rover(s) and the lander(s) contaminated. Thus, no accessible surface of Martian rocks and soil is Earth contamination free. As a result of the latter, only subsurface samples (either rock or soil) can be and will be collected for eventual return to Earth. Uncontaminated samples can be collected from a Category IVa clean platform. Both subsurface soil and rock samples can be maintained clean if they are collected by devices that are self-contained and clean and sterile inside only. The top layer of the sample is removed in a manner that does not contaminate the collection tools. Biobarrier (e.g., aluminum foil) covering the moving parts of these devices may be used as the only self removing bio-blanket that is required. The samples never leave the collection tools. The lids are placed on these tools inside the collection device. These single use tools with the lid and the sample inside are brought to Earth in the OS. The lids have to be designed impenetrable to the Earth organisms. The latter is a well established art.

Dolgin, B.↗