Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “subcritical experiments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Expanding Benchmarks for Nuclear Data Validation [Slides]

The presentation discusses benchmarking in comparison to experimental truth, the integral experiments that were performed, and that benchmarks are evaluated experiments. It also discusses validation testing, and that the ultimate goal of the validation end product is to improve evaluated nuclear data for applications It does state that validation highlights errors in the Nuclear Data Pipeline that affect applications, for example: Missing Cd Capture Gammas in ENDF/B-VII.1. It acknowledges that additional types of experiments are needed to test data used in applications, and that validation experiments do not have to be complicated and expensive. The presentation also discusses different types of measurements including activation foil and fission chamber measurements, reactor kinetics measurements, and subcritical measurements. The presentation concludes with an experiment summary and states that all applications need validation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Subcriticality Measurements for a Changing Concentration Uranyl Nitrate Solution Tank by Californium Source-Driven Noise Analysis

Subcritical californium source-driven noise analysis (CSDNA) measurements were performed at the Oak Ridge Critical Experiments Facility in 1983 using a stainless-steel tank with an inside diameter of 76.2 cm and a height of 91.4 cm but only filled with a uranyl (93.16 wt.% 235 U) nitrate solution to a height of 76.2 cm for all measurements. The free acid content of the uranyl nitrate solution was less than 0.01 N to minimize hazards in handling. The total available highly enriched uranium for these measurements was 5,296 g. The concentration of the solution was varied from the highest density of 14.71 grams of uranium per liter (g U/L) initially in 16 steps, lowering the concentration to 0.3492 g U/L, and finally using a tank filled with only water. The tank had a Plexiglas lid to minimize evaporation. The Cf source was contained in a re-entrant Lexan tube which could be in the solution parallel to the axis of the cylindrical tank. The detectors were 3 He proportional counters in the solution in shrink-fit tubing to isolate the counters from the fissile solution and adjacent to the outside of the tank. In some cases, the detectors were scintillators adjacent to the outside of the tank. In other cases, the source was external to the tank. Some data presented in this report are from notes and are not in the logbook. The prompt neutron decay constant was obtained from fitting the date from the CSDNA measurements. The purpose of this report is to document the experimental information for the measurements performed so that later, researchers could perform the required uncertainty and calculational analyses and documentation to use these data for an International Nuclear Criticality Safety Benchmark Program (ICSBEP) or a Nuclear Energy Agency benchmark. The prompt neutron decay measurements could be the basis of as International Reactor Physic Benchmark Program. The data from these measurements are available from the Records Management Services Department of Oak Ridge National Laboratory, and the logbook is also available from the ICSBEP at Idaho National Laboratory. Preparation of the present report is part of a larger cooperative effort between Idaho National Laboratory (INL) and Oak Ridge National Laboratory (ORNL) to document more than 15 undocumented critical and subcritical experiments enumerated in ORNL/TM-2019/18 and performed by ORNL at ORCEF and other USDOE critical experiments facilities using more than 500 operational days of critical facility time.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Leak detection in a subcritical boiler

Thermal power plants experience cycling duty leading to the fatigue of the boiler and heat exchanger tubes. As a result, tube failures occur frequently in coal fired fleets leading to forced outages. Furthermore, because the tube leaks have been the major source of unwanted shutdowns and the number of outages is increasing, present work focuses on the detection and isolation of the leak in a subcritical boiler based upon the process data from a commercial coalfired power plant. The mass balance equation around the steam drum was analyzed using timeseries data collected from a 300 MW power plant. The ratio of the feed water mass flow rate to the steam mass flow rate was defined as a key parameter for detecting leaks. The difference in slope between the feedwater and steam mass flow rate during the normal and faulty operations was established as the upper control limit for real time monitoring. To reduce false alarm rates that arise when raw signal is directly compared against the threshold due to common process fluctuations, an optimal filter was derived for smoothing. It was found that the optimal filter reacted much more quickly to process changes than an exponential moving average filter, around 8 h earlier on average. Occurrence of relatively high false alarm rates even in the filtered responses was related to the cycling of the boiler from the base load condition. Variable threshold was established to keep false alarm rates to the minimum while maintaining the leak detection rate. Finally, the leak was located at the economizer and this could readily be isolated by investigating the magnitude of the mass flow rates ratio and the temperature at the economizer outlet.

42 ENGINEERING↗

Comparison of Measured and Simulated Neutron Counting with 3He Detectors and the Subcritical Water-Moderated UO2 7uPCX Assembly

An experiment designed to compare neutron noise analysis techniques on subcritical assemblies using differing neutron detector designs was developed as a collaborative effort between the Institut de radioprotection et de surete nucleaire (IRSN), Los Alamos (LANL), Lawrence Livermore (LLNL), and Sandia National Laboratories. This experiment has the final goal of characterizing neutron noise analysis accuracy in determining multiplication in light water systems for various neutron detection systems. This experiment utilized the Seven Percent Critical Experiment (7uPCX) facility at Sandia National Laboratories. The 7uPCX is an assembly designed to investigate light water systems with fuel enrichment above 5% and is able to use square or hex grid plates with varying pitches.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

LANL FY21 NCSP Highlights [Slides]

This presentation highlights the activities of Los Alamos National Laboratory (LANL) in fiscal year 2021.These include the celebration of the tenth anniversary of NCERC operations, a large experiment campaign (IER 488 - MUSiC: Measurements of Uranium Subcritical and Critical), preparation for FY22 experiments, the completion of several ongoing experiments, and a control system upgrade project.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Feasibility Study for a Subcritical Assembly at the Oak Ridge National Laboratory

A conceptual design has been completed for a new subcritical assembly at Oak Ridge National Laboratory (ORNL). This subcritical assembly will support the Nuclear Criticality Safety Program (NCSP) training and education program to augment current subcritical assembly capabilities at Sandia National Laboratories (SNL) and at the National Criticality Experiments Research Center (NCERC). The proposed subcritical assembly uses legacy AGN-201M research reactor fuel plates that are available at the Y-12 National Security Complex. This subcritical assembly contains approximately 620 grams of 235 U as UO 2 particulates distributed homogeneously in radiation-stabilized polyethylene. The fuel plates will have a graphite neutron reflector to obtain a core multiplication, $M$, from 10 to 50, corresponding to a k eff of 0.9 to 0.95, respectively. The subcritical assembly will be able to support at least four experiments for the training courses: the addition of fissile material to increase neutron multiplication (mass), a core separation experiment (interaction), the effect of adding moderators to the core (moderation), and the effect of adding neutron absorbers to the core (poison/absorption). The proposed ORNL subcritical assembly will provide additional student bandwidth to support NCSP training courses and to provide for some backup capacity in the event that nuclear facility operations are disrupted at SNL or NCERC due to some unforeseen issue. The subcritical assembly will be designed to be an inherently safe subcritical assembly—subcritical under all normal and abnormal conditions—and it will provide the capability to conduct hands-on training to support NCSP and general nuclear criticality safety (NCS) staff training and qualification goals.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Design of Nuclear Criticality Safety Framework for Hands-on Construction of Fast Systems Over Ranges of Multiplication

Since 1945, Los Alamos National Laboratory (LANL) has performed critical experiments, primarily at the Los Alamos Critical Experiments Facility (LACEF) at Technical Area 18 (TA-18). Since 2011, these experiments have been conducted by the National Criticality Experiments Research Center (NCERC), operated by LANL, at the Device Assembly Facility (DAF) in the Nevada National Security Site (NNSS). These experiments utilize various types of Special Nuclear Material (SNM). Some of these experiments utilize what is referred to as the Rocky Flat Shells, which are called such as they came from the Rocky Flats Plant. These concentric hemi-shells are made of Highly Enriched Uranium (HEU), which is 93 w/o 235U. Fig. 1. Subset of the Rocky Flat Shells LANL is designing a new subcritical hands-on experiment with the goal of achieving a neutron multiplication in the range of 50 to 200, which correlates to Keff values of 0.98 to 0.995. ANSI/ANS-1 is the standard for Conduct of Critical Experiments which governs critical operations at NCERC. Section 3.9 of ANSI/ANS-1 states that when manipulating a critical assembly by hand, the predicted k eff of a known configuration should not exceed 0.95 (a neutron multiplication of 20). This presents a challenge, as this system would have a higher multiplication than 20 and the assembly would have to remain subcritical in normal and credible accident scenarios. To ensure the safety of such an assembly, the different normal and abnormal conditions that could alter the criticality 1 MCNP® and Monte Carlo N-Particle® are registered trademarks owned by Triad National Security, LLC, manager and operator of Los Alamos National Laboratory. Any third party use of such registered marks should be properly of the system must be considered and analyzed. If such a condition is deemed to be credible, it will be further investigated using the Monte Carlo N-Particle (MCNP) transport code. If the results of these simulations show that a k eff larger than one could be possible, modifications to the assembly will be made until such an event is deemed no longer possible.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Subcritical Neutron and Gamma Noise Measurements at the Seven Percent Critical Experiment (7uPCX) [Slides]

Post measurement synchronization of noise signals allowed for the investigation of previously unseen correlations. Noise of gamma, thermal and fast neutron signals performed similarly in estimating the prompt neutron decay constant at various subcritical states. The CPSD amplitude terms displayed different magnitudes. The neutron-based amplitudes suffered more from changes in detector efficiency as the number of fuel rods in the system increased. The time lag between 3 He tubes is observable using the CPSD phase angle and agreed with a simplified diffusion estimation.

3He detectors↗

A New Era of Nuclear Criticality Experiments: The First 10 Years of Radiation Test Object Operations at NCERC

The work presented in this paper focuses on the first 10 years (2011–2020) of radiation test object (RTO) operations at the National Criticality Experiments Research Center. RTOs are subcritical configurations of special nuclear material that are built by hand. These configurations are utilized for benchmark experiments, detector testing/characterization, and training. An overview of the types of measurements used in RTO operations is given as well as a history of RTO operations at Los Alamos National Laboratory from 1944–2011.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Prompt Fission Uranium Neutron Spectrum (PFUNS) Experiment: Critical Configurations and Irradiations

The objective of the Prompt Fission Uranium Neutron Spectrum (PFUNS) experiment is to reduce the uncertainty of the Prompt Fission Neutron Spectrum (PFNS) of 235 U above 8 MeV. The experiment was performed at the DOE National Criticality Experiments Research Center (NCERC) at the Nevada National Security Site. To meet the experiment objective, activation foils were placed in a central void region of a critical configuration consisting of concentric highly enriched uranium (HEU) metal hemishells. The set of activation foils were chosen based on threshold reactions to neutron energies across the fission spectrum, but especially those in the high energy tail of the fission spectrum. PFUNS was performed on the Planet critical assembly machine at NCERC and uses the Rocky Flats (RF) HEU hemishells. PFUNS has similarities to the Measurement of Uranium Subcritical and Critical (MUSiC) experiment conducted at NCERC in 2021, which also used RF hemishells, but contains a large central cavity to allow for a sample plate to be inserted. This large void means that much more HEU is needed to achieve a critical configuration (108 kg for PFUNS versus 59 kg for MUSiC). This work describes the 2024 experiment execution of four critical configurations and two irradiations for the PFUNS project.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Subcritical Neutron and Gamma Noise Measurements at the Seven Percent Critical Experiment (7uPCX)

As part of a collaborative international effort organized by Lawrence Livermore National Laboratory (LLNL), with key participants from L’Institut de radioprotection et de sûreté nucléaire (IRSN), Los Alamos National Laboratory (LANL), and Sandia National Laboratories (SNL), a series of high-multiplication subcritical neutron and gamma noise measurements were planned and executed. The primary aim of this research was to advance detector technology, assess the validity of gamma noise for subcriticality measurements, and nuclear criticality safety, focusing on collecting list-mode or time-series data from various reactor configurations with multiplication values ranging from 20 to 310. This comprehensive dataset enabled a detailed comparative analysis of multiple detector systems and the results of both neutron and gamma noise measurements. In this work we focus on experimentally comparing the results from neutron and gamma noise measurements. We note good agreement between estimations of the prompt neutron decay constant and demonstrate the effects of changing reactor geometry on the efficiency of the differing methods.

Criticality↗

Experimental Investigation of Subcritical Neutron and Gamma Noise Methods at the Seven Percent Critical Experiment (7uPCX)

As part of a collaborative international effort organized by the Lawrence Livermore National Laboratory (LLNL), with key participants from the Institut de radioprotection et de sûreté nucléaire (IRSN), Los Alamos National Laboratory (LANL), and the Sandia National Laboratories (SNL), a series of high-multiplication subcritical neutron and gamma noise measurements was planned and executed. The primary aim of this article was to advance detector technology, assess the validity of gamma noise for subcriticality measurements, and nuclear criticality safety, focusing on collecting list-mode or time-series data from various reactor configurations with multiplication values ranging from 20 to 310. This comprehensive dataset enabled a detailed comparative analysis of multiple detector systems and the results of both neutron and gamma noise measurements. In this work, we focus on experimentally comparing the results from neutron and gamma noise measurements. We note good agreement between estimations of the prompt neutron decay constant and demonstrate the effects of changing reactor geometry on the efficiency of the differing methods. Our results agree well with independent experimental measurements and simulations performed by LLNL.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Progress Update on the MUSIC Critical Benchmark

The Measurement of Uranium Subcritical and Critical (MUSiC) experiment was carried out from December 2020 through April 2021 at the National Criticality Experiments Research Center (NCERC). This measurement campaign featured bare configurations of the Rocky Flats highly-enriched uranium (HEU) shells, with each configuration having different numbers of these shells. The goal of the experiment was to test multiple neutron multiplicity detectors and measurement methods for a large range of neutron multiplication values. The large range of multiplications allows researchers to see when the combination of detectors and methods break down as the configurations reach the delayed supercritical window. The critical configurations were the extreme end of the multiplication range in MUSIC configurations. A critical benchmark in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook is planned to help further validate nuclear data. Even though there are many benchmarks focusing on the fast spectrum for highly-enriched uranium, an additional benchmark that is well documented and up to the modern standard of the handbook would be a welcome addition. Given that there are no other materials such as moderators or significant reflectors, and its similarity to Lady Godiva, it is possible that this could be very useful for validation of 235 U nuclear data in the future.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Feasibility Study for a Proposed Subcritical Assembly at Oak Ridge National Laboratory [Slides]

To provide additional NCS training bandwidth, a simple feasibility study was performed for a proposed, inherently safe, subcritical assembly at ORNL for the US Department of Energy (DOE)/National Nuclear Security Administration (NNSA) NCSP training and education (T&E) program. The NCSP performs subcritical, delayed critical and prompt supercritical experiments to support the NCSP T&E program. ORNL performed a study to examine the feasibility of a subcritical assembly with existing fuel that meets the ANSI/ANS-8.26 standard. Section 7.4 of the standard requires NCS staff to participate in hands-on experiments meant to “…demonstrate how varying the properties of a fissionable material system can affect neutron multiplication.” This training is performed to ensure NCS, and operations staff are aware of the risks involved with conducting operations with fissionable materials outside reactors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Critical and Californium Source-Driven Noise Analysis Subcritical Measurements with an Unreflected Cylindrical Tank of Mixed Uranium-Plutonium Nitrate Solution

The reported experiments were performed by Oak Ridge National Laboratory (ORNL) at the Battelle Northwest Laboratory’s (now Pacific Northwest National Laboratory) critical experiments facility at Hanford, Washington in 1981 and used 16 days of critical facility time, not including 10 days for setup and removal of ORNL equipment. These measurements were to assess the capability of the Cf source-driven noise analysis (CSDNA) method to measure the subcriticality (keff) of mixed U-Pu nitrate solutions. In addition to the CSNDA measurements, measurements were also performed near delayed criticality where CSDNA measurements cannot be performed. This report documents the experiments that were not reported at that time by presenting the ORNL experimental results and any online analysis performed during and shortly after the measurements. The mixed nitrate solution had a U concentration at 188 grams per liter (g/L), a Pu concentration of 280 g/L, free acid normality of 2.80, H ion molarity of 5.9 and a specific gravity of 1.754 g/cm 3 , a 240 Pu isotopic content of 7.981 wt. %, and a 235 U isotopic content of 0.724 wt. %. The stainless-steel tank for the solution had an inside diameter of 35.38 cm, an outside diameter of 35.53 cm, a height of 56.72 cm, and bottom thickness of 0.9525 cm. A Zircaloy pipe with a 3.1496 cm outside diameter, a 2.7788 cm inside diameter, and bottom thickness of 0.635 cm was available for insertion of the Cf source in the center of the fissile solution. The Cf source was also located at the outside surface of the tank (solution height varied from 10 to 53 cm) and in the center of the solution (solution height varied from 10 to 60.7 cm). The CSDNA measurements were not analyzed online to determine the subcritical neutron multiplication factors. At all subcritical states, the break frequency noise analysis data was fitted to obtain the prompt neutron decay constant. The neutron multiplication factors were determined for the two configurations of the measurements near delayed criticality. The subcritical neutron multiplication factors from the CNSDA measurements can be obtained with further analysis. However, the near delayed critical configuration, the prompt neutron decay constants, the count rates, and the measured cross and auto power spectral densities can be calculated directly for benchmarking. Much of data presented in this report are from ORNL notes—not in the ORNL logbooks. For the final benchmark analysis, the data from the Battelle Northwest Laboratory (which operated the critical facility in 1981) critical facility logbook should be consulted and be incorporated where appropriate. The purpose of this report is to document the experimental information for the measurements performed so that at a later date researchers could perform the required uncertainty and calculational analyses and documentation to use these data for an International Criticality Safety Benchmark Program (ICSBEP) or Nuclear Energy Agency benchmark. The data from these measurements are available from the ORNL Records Management Services Department, and the logbook is available from ICSBEP at Idaho National Laboratory. Preparation of the present report is part of a larger cooperative effort between Idaho National Laboratory (INL) and Oak Ridge National Laboratory (ORNL) to document more than 15 undocumented critical and subcritical experiments enumerated in ORNL/TM-2019/18 and performed by ORNL at ORCEF and other USDOE critical experiments facilities using more than 500 operational days of critical facility time.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nuclear Criticality Safety Pipeline Course with Hands-On Experimental Training at Lawrence Livermore's Inherently Safe Subcritical Assembly Training Center

The Nuclear Criticality Safety Divisions at Lawrence Livermore National Laboratory (LLNL) and Los Alamos National Laboratory (LANL) have partnered with Prof. Massimiliano Fratoni of the University of California Berkeley to offer a semester long course on nuclear criticality safety. This course is part of a larger pipeline project among many of the Department of Energy (DOE) laboratories designed to stimulate student interest in the field of criticality safety. The course focuses on teaching the fundamentals of criticality safety, familiarity with national and consensus standards, and preparing criticality safety evaluations. Students also receive hands-on experience with special nuclear material by performing experiments with the Inherently Safe Subcritical Assembly (ISSA) at LLNL. Guest lectures are taught remotely and in-person by criticality safety engineers at LLNL and LANL, giving students an opportunity to interact with professionals in the field. The students complete a semester long project involving developing and writing a criticality safety evaluation. As universities tend to focus heavily on nuclear power and advanced nuclear reactor design, this course gives students a better understanding and perspective of what criticality safety entails. The goal of this pipeline course is to introduce students to criticality safety as another available field for nuclear engineers. It is also a way for criticality safety programs to identify talented students who have the interest and aptitude to work in criticality safety for hire upon graduation. LLNL and LANL have both hosted past students as summer students, participated in student's graduate projects, and hired students as criticality safety engineers. This has provided a unique opportunity for criticality safety programs to spot young talent with better retention outcomes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nuclear data covariances are critical input to determine upper sub-critical limits and to design experiments to increase it [Slides]

This presentation discusses how Upper Subcritical Limits (USL) are key parameters to determine operational limits in nuclear criticality safety evaluations. It also discusses an example of plutonium casting operation using tantalum at LANL PF-4. The Whisper tool at Los Alamos relies on many inputs, including covariance data, leading the presentation to ask if an existing benchmark data be used in Whisper to adjust nuclear data and covariances to justify a higher USL. If not, Whisper can be used to help design an optimal new benchmark experiment. The presentation also seeks to determine what the possible impacts are on USL and operational limits for plutonium casting. In conclusion, nuclear data covariances are used for by Whisper for: GSSL adjustment of nuclear data and covariances, identification of most similar existing benchmark experiments to application, simulation of Upper Subcritical Limit of application, and input to optimization techniques for designing most appropriate new benchmark experiment(s) to meet requirements. This requires a complete set of nuclear data covariances, benchmarks and k-effective sensitivity profiles (for both benchmarks and applications). The presentation concludes by asking if end users should trust results that depend on current covariance data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗