Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “steam flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Characterization of steam impulse turbine for two-phase flow

The characterization of a steam impulse Terry turbine operating with single- and two-phase air–water ingestion has been performed; the air mass fraction ranged from 1.0 (single-phase air) down to 0.05. The two-phase characteristics were obtained over a range of turbine inlet pressures and turbine rotational speeds. Here, the torque produced and the mixture flow rate through the turbine were recorded. Based upon experimental air/water measurements, the turbine Affinity Laws have been modified to include the effects of two-phase flow.

42 ENGINEERING↗

Simulation of Boiling Two-Phase Flow in a Helical Coil Steam Generator Using the Spectral Element Code Nek-2P

To enable the design of a light water small modular reactor, the boiling flow inside a helical coil steam generator has been simulated with the two-fluid model in Nek-2P. Nek-2P is the multiphase branch of the spectral element code Nek5000. Details of the implementation of the two-fluid model and the included closure models are discussed. The presented closure models include interactions for momentum, heat, and mass transfer between phases. Models for the drag, lift, and turbulent dispersion forces are included. The complete model is fully consistent in the limits of both phasic volume fractions approaching zero and is able to simulate flows of dispersed vapor, continuous liquid, dispersed liquid, continuous vapor, or any combination thereof. The closure models and their implementation in Nek-2P have been validated by comparing to experimental data for a boiling flow, demonstrating excellent agreement. Results from the simulation of the helical coil indicate strong phasic separation driven by the effects of buoyancy and inertia. Finally, significant differences were observed in the results compared to simulations performed using Star-CCM+, although these differences were somewhat expected.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Once-Through Steam Generator Model Analysis Using Python and Advanced Optimization Tools (Summer Internship Report)

This study focuses on the parametric analysis of design parameters for a once-through steam generator (OTSG) model, using python and advanced optimization tools to facilitate applications such as the flowing autoclave steam generator (FASG) test cases. Building on previous research involving another OTSG with a different design, this project aims to enhance our understanding of how steam generators (SGs) behave and how their outputs are influenced by changes in design. The reason for this design change is to allow for more precise modeling and optimization of SG performance, to provide a comparative analysis between the two designs, and to set up the model for integration with the FASG test case. The OTSG python-model is a mathematical representation (including fluid flow and heat transfer equations/models/correlations) of a steam-generating unit in a pressurized water reactor-type small modular reactor system. Design studies involve changing the model’s input design parameters to observe the resulting effects on the output of the system. By using advanced optimization tools, such as the Risk Analysis Virtual Environment (RAVEN) developed at Idaho National Laboratory, detailed design parametric studies and model optimization were performed. Six input parameters—pressure, temperature, and mass flow rate for the inlet of the primary-side (hot fluid) and secondary-side (cold fluid), respectively, of the SG—were randomly perturbed via RAVEN’s Monte Carlo Sampler module, using uniform distributions (i.e., ±1%, ±5% and ±10% relative changes) for 600 samples. The analysis provides valuable insights into SG optimization and can be used for sensor placement optimization to effectively monitor and obtain experimental data in other tests.

20 FOSSIL-FUELED POWER PLANTS↗

Flow Instabilities in boiling channels and their suppression methodologies—A review

Small modular reactors (SMRs) are gaining significant attention as a promising solution for clean and sustainable nuclear-power generation. However, the operation of SMRs is subject to various challenges, including two-phase flow instabilities. Flow instability has the potential to trigger flow-induced vibration and cyclic fluctuations in local thermal stress. These instabilities frequently manifest because of the complex interplay among a multitude of factors, encompassing thermal-hydraulic conditions, the geometric configuration of the steam generator, and operational parameters. These conditions could subsequently lead to premature critical heat flux, equipment malfunctions, and other safety concerns. Here, the endeavor to address steam-generator flow instabilities is of utmost importance in augmenting the sustainability and efficiency of contemporary energy production. This study offers a comprehensive review of instabilities in two-phase flow, with a particular focus on the influential factors impacting the stability of flow boiling. Furthermore, it delves into the processes of identifying, characterizing, and ameliorating these instabilities, emphasizing pivotal findings, methodologies employed, and avenues for prospective research. The primary parameters of concern encompass the efficient transfer of thermal energy, the optimization of mass-flow rates, and the establishment of favorable boundary conditions, all in the context of steam generator design to alleviate instability for water-cooled SMRs. These discernments bear substantial ramifications for enhancing reactor performance and ensuring operational safety.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Pressure Drop-Flow Rate Curves for Single Phase Steam in Steam Generator U-tubes During Severe Accidents

Thermally induced steam generator tube rupture (TI-SGTR) can occur in pressurized water reactors (PWRs) with U-tube steam generators (SGs) during high pressure severe accident sequences resulting in containment bypass. Robust natural circulation patterns including in-vessel natural circulation and countercurrent flow to and from the SGs of superheated steam and other hot gases heats cooler structures in the reactor coolant system (RCS). The buoyancy driven flows return cooler and denser gases back to the core slowing the progression of some core degradation phenomena and failure of the lower head. As much as 50 percent of the decay energy and energy produced from core degradation oxidation reactions can be transported from the core to SGs resulting in the heat up and thermal creep of RCS pressure boundary components including hot leg nozzles, pressurizer surge line, and the SG tubes, many of which contain flaws. The creep failure of an individual tube is dependent on the transitory heating of the tube, a function of the mass flow rate through the tube and local temperature history of steam entering the tube. Buoyancy driven natural circulation flow rates are determined by changes in gravitational head, a combination of changes in fluid density due to heat transfer and change in elevation, and irreversible pressure drops resulting primarily from friction loss in the flow paths and other form losses. The nonuniform flow distribution in U-tubes of varying lengths and heights during single-phase liquid and two-phase natural circulation has been extensively studied in scaled test facilities and verified numerically in previous works. We hypothesize the countercurrent natural circulation of single-phase superheated steam in U-tube SGs is governed by the same characteristic pressure drop-flow rates curves of single-phase liquid and two-phase natural circulations in U-tubes connected to common plena derived in. Secondly, we propose flow distribution is a function of U-tube geometry - height, length, hydraulic diameter, etc., and the larger SGs of Combustion Engineering (CE) style 2 x 4 PWRs, which are the focus of this study, will show greater nonuniformity in tube by tube flow rates and ratio of forward flowing tubes to reverse flowing tubes. This work derives characteristic pressure drop-flow rate curves for single-phase superheated steam in CE-type SGs during a high pressure station blackout (SBO) sequence with failed auxiliary feedwater (AFW) and dry secondary side which is closely related to the TI-SGTR event. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Large Eddy Simulation of the Flow Behavior in a Simplified Helical Coil Steam Generator

Large eddy simulation (LES) is conducted for the flow over the shell side of a helical coil steam generator (HCSG) heat exchanger. Simulations are conducted on a simplified experimental test section that represents a one-column region of the helical coils using half-rods. Although the rods are wall-bounded, the flow still exhibits the turbulent characteristics and fluctuations from vortex shedding that one would expect from crossflow around a cylinder. The spectral element, computational fluid dynamics (CFD) code Nek5000, is used to capture the physics, and the results are compared with particle image velocimetry (PIV) measurements. In order to ensure that the turbulence is resolved, analysis is conducted by using the Taylor length scales and normalized wall distance. Sensitivity to the inlet boundary conditions (BCs) and the spatial discretization for different polynomial order solutions are also studied, finding only minor differences between each case. Pressure drop and velocity statistics show reasonable agreement with PIV. Proper orthogonal decomposition (POD) analysis reveals that the primary modes are similar between experiment and simulation, although the LES predicts higher turbulent kinetic energy than does PIV. Overall, the study establishes the resolution and resources required in order to conduct a high-fidelity simulation over 12 helical rods.

Lai, Jonathan K.↗

Dynamic Behavior of Oval-Twisted Helical Tube Heat Exchanger: Numerical Study with RELAP5-3D

Convective heat transfer characteristics and theoretical thermal stress behaviors are numerically calculated using RELAP5-3D for the helical-coiled once-through steam generator (H-OTSG) and the novel heat exchanger design known as the oval-twisted helically coiled heat exchanger (OTHCHX) under (1) fluctuating wall temperature conditions, (2) square-wave pulsating flow conditions, and (3) the combined effects of fluctuating wall temperature and square-wave pulsating flow conditions. Heat transfer coefficient models for the H-OTSG and OTHCHX were developed based on existing data and implemented into RELAP5-3D, successfully capturing the N⁢uavg behavior within 8% to 10% of the reported data. Under fluctuating wall temperature conditions, the OTHCHX displayed higher N⁢u avg behavior than the H-OTSG. As 𝑓 increased, the $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ decreased. The $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ was higher for the OTHCHX than for the H-OTSG under fluctuating wall temperature conditions. Under pulsating flow conditions, the H-OTSG and OTHCHX displayed much higher 𝑁⁢𝑢 𝑎𝑣𝑔 than under constant flow conditions. The H-OTSG displayed a higher $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ over the OTHCHX. Under combined fluctuating wall temperature and pulsating flow conditions, the augmented heat transfer behavior from the pulsating flow was counteracted by the wall temperature fluctuations, producing slightly higher 𝑁⁢𝑢 𝑎𝑣𝑔 over constant wall temperature, constant flow conditions, but much lower than only constant pulsating flow under constant wall temperature conditions. The effects of simultaneous wall temperature fluctuations and square-wave pulsating flow caused higher $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ than that of only wall temperature fluctuations or pulsating flow. As the Reynolds number (Re) increased, $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ increased. However, when 𝑓=𝑓$_{\dot{m}}$, the $𝜎^{𝑚⁢𝑎⁢𝑥}_{𝑡⁢ℎ}$ showed decreasing values as Re increased. In conclusion, the results indicate that thermal-fluid resonance can help mitigate thermal stresses.

Thermal stress↗

Flow instabilities in helical-coil steam generators for small modular reactors: A review

Here, this study covers the research and discoveries in two-phase flow-boiling instabilities available in the literature—specifically for a helical-coil steam generator (HCSG), including experimental findings, theoretical research, computational models, and system code analyses—supporting research and development of representative small modular reactors (SMRs). Like other new and advanced reactor systems, water-cooled SMRs require experimental data from both integral and separate thermal-hydraulics test facilities for the verification and validation (V&V) of the computational models and computer codes in order to design and obtain regulatory approval. The complex dynamics of two-phase flow-boiling instabilities includes flow regimes physics phenomena, flow-channel geometries, heat-transfer behavior, and interactions among the solid–liquid-gas within the system boundary, all of which are pivotal for understanding the design and operational challenges of SMRs. This study focuses on identifying the relevant knowledge gaps on boiling instabilities—specifically for a HCSG—and provides insights about future research direction optimizing the transport of thermal energy, mass-flow rates, and boundary conditions that ensure the adequate heat-transfer performance, operational stability, and safety associated with SMR systems.

20 FOSSIL-FUELED POWER PLANTS↗

Preliminary analysis of loss-of-coolant accident in Fukushima nuclear accident

Loss-of-Coolant Accident (LOCA) in Boiling Water Reactor (BWR) especially on Fukushima Nuclear Accident will be discussed in this paper. The Tohoku earthquake triggered the shutdown of nuclear power reactors at Fukushima Nuclear Power station. Though shutdown process has been completely performed, cooling process, at much smaller level than in normal operation, is needed to remove decay heat from the reactor core until the reactor reach cold-shutdown condition. If LOCA happen at this condition, it will cause the increase of reactor fuel and other core temperatures and can lead to reactor core meltdown and exposure of radioactive material to the environment such as in the Fukushima Dai Ichi nuclear accident case. In this study numerical simulation has been performed to calculate pressure composition, water level and temperature distribution on reactor during this accident. There are two coolant regulating system that operational on reactor unit 1 at this accident, Isolation Condensers (IC) system and Safety Relief Valves (SRV) system. Average mass flow of steam to the IC system in this event is 10 kg/s and could keep reactor core from uncovered about 3,2 hours and fully uncovered in 4,7 hours later. There are two coolant regulating system at operational on reactor unit 2, Reactor Core Isolation Condenser (RCIC) System and Safety Relief Valves (SRV). Average mass flow of coolant that correspond this event is 20 kg/s and could keep reactor core from uncovered about 73 hours and fully uncovered in 75 hours later. There are three coolant regulating system at operational on reactor unit 3, Reactor Core Isolation Condenser (RCIC) system, High Pressure Coolant Injection (HPCI) system and Safety Relief Valves (SRV). Average mass flow of water that correspond this event is 15 kg/s and could keep reactor core from uncovered about 37 hours and fully uncovered in 40 hours later.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Method of calculating blade-to-blade plane flow in centrifugal pump

Steam filament solution determines velocity distribution due to potential flow in the blade-to-blade plane of the radial impeller. This is used to determine the mass-averaged relative fluid angle, which is in turn used in an axisymmetric program to obtain steam surfaces of the assumed axisymmetric flow.

Jackson, E. D.↗

Understanding Environmental Barrier Coating Lifetimes and Performance for Industrial Gas Turbines

Hydrogen or hydrogen blend fuels are expected to replace natural gas in land-based industrial gas turbines (IGTs) to support a greener power economy. Silicon carbide (SiC) base ceramic matrix composites (CMCs) are considered for replacement of Ni-based superalloys to facilitate future efficiency improvements. SiC CMCs require environmental barrier coatings (EBCs) to mitigate volatilization from high-temperature steam, thus making the EBC lifetime critical information for identifying CMC component lifetimes. Here, the goal of this project is to determine the maximum bond coating temperature underneath the EBC for achieving an IGT component lifetime goal of 25,000 h, which is far greater than current CMC component lifetime requirements for aeroturbine applications. To provide data for the lifetime model, laboratory testing used atmospheric plasma-sprayed rare-earth silicate EBCs on monolithic SiC substrates with an intermediate Si bond coating. Specimens exposed to 1-h thermal cycles in flowing air–steam environments and reaction kinetics were assessed from 700 °C to 1350 °C by measuring the thickness of the thermally grown silica scales. The silica growth and phase transformation appear critical in predicting EBC lifetime and several strategies have been explored to reduce the oxide growth rate and improve EBC durability at elevated temperatures. Advanced characterization using Raman spectroscopy has helped clarify this system.

08 HYDROGEN↗

Numerical investigation of the flow inside the helical coil steam generator test section - 18589

A Helical Coil Steam Generator (HCSG) is one type of heat exchangers used for the purpose of increasing the efficiency of heat transfer with low pressure drop in recent design of high temperature reactors (HTRs). To investigate the fluid phenomena around the coil bundle of HCSG, the experimental facility had been designed and computational fluid dynamics (CFD) simulations had been conducted to compare the results of experimental ones. In this study, various types of turbulent models in the commercial CFD code (STAR-CCM+) were tested with various grid sizes on the target Reynolds number, Re{sub D} = 163,000, to enhance the validity of the simulation result. The computational domain used to run the CFD simulation had the same geometry of the experimental test section which had the half-coil shaped ribs on each curved channel wall. The working fluid properties employed in the simulation was scaled to the target Reynolds number at room temperature. The averaged static pressure drop induced by coil bundle inside the test section was obtained between the inlet and outlet of the test section. In addition, flow structures inside the flow channel were examined going through the velocity field distribution around the coil and the effect of vortical structures in the flow channel. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Film condensation with high heat fluxes and scaled experiments using pure steam for reactor containment cooling

Condensation tests were performed using a newly developed test facility for scaling the passive containment cooling system (PCCS) to a small modular reactor (SMR). The PCCS of the SMR plays a pivotal role in ensuring greater safety, reliability, and compactness than what is afforded by traditional reactors. Therefore, a well-designed PCCS is essential to SMRs. However, previous studies and test data were unsuitable for scaling, due to high variation in the test geometry and operating conditions. This study intends to close this research gap by using a novel designed scaled test facility consisting of vertical condensing test sections featuring 1-, 2-, and 4-inch-diameter condensing tubes with annular water cooling, and by applying superheated and saturated steam with different steam mass flow ranges of 5–25 g/s. Further, the primary test data, including axial temperatures, mass flow rates, and pressures, were used in conjunction with a standard data reduction method to estimate critical parameters such as heat fluxes, heat transfer coefficients, and condensation rates. These scaled test data would support improving empirical correlations and validating condensation models to identify scaling distortion for SMR PCCSs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Design of a Test Article and Test Facility to Investigate Flow-Induced Vibration of a Helical Coil Steam Generator

NuScale Power LLC (NuScale) is developing a small modular reactor (SMR) with unique design features and arrangements that require testing to provide quality data for safety analysis codes and design validation, as well as for technology maturation. A multi-phase testing program is underway at NuScale to demonstrate that its unique helical coil steam generator design is not susceptible to flow-induced vibration during operation. The phases of the testing program include modal testing of individual tubes during test article fabrication and modal and flow testing after test article completion. NuScale has contracted SIET S.p.A. in Piacenza, Italy for the design and fabrication of the test article and test facility. In-fabrication testing was performed at the site of test article build in Cremosano, Italy. Modal testing and flow testing of the completed test article will be performed at SIET’s facilities in Piacenza. This paper discusses the design of the test article and test facility, including supporting systems, required to generate the quality data required to support NuScale’s comprehensive vibration assessment program as part of the overall licensing effort for NuScale’s first-of-a-kind small modular light water reactor.

Flow-induced vibration, helical coil, steam genera↗

Enabling Staged Pressurized Oxy-Combustion: Improving Flexibility and Performance at Reduced Cost

Introduction: The staged pressurized oxy-combustion (SPOC) process, developed by Washington University in St. Louis (WUSTL), is an oxy-combustion carbon capture technology that employs a steam power cycle to generate electricity. As with atmospheric-pressure oxy-combustion processes, carbon dioxide (CO 2 ) capture rates of 90% or higher can be achieved. The staged-combustion approach of the SPOC process, when operated at elevated gas pressure, allows for near elimination of flue gas recycle (FGR) and leads to significant improvements in efficiency and reduced costs. The primary goal of this project was to investigate the potential for SPOC for flexible operation beyond the capabilities of conventional coal-fired power plants, particularly those employing carbon capture and storage (CCS). Oxy-combustion differs from conventional coal combustion in that the combustion of coal is carried out using oxygen as opposed to air. The resultant flue gas is a mixture of primarily CO 2 and water, greatly simplifying CO 2 capture. As SPOC does the oxy-combustion process under pressure, it is higher efficiency and lower cost than atmospheric oxy-combustion. The project was led by the Electric Power Research Institute, Inc., with the assistance of WUSTL, Doosan Babcock (DBL – boiler plant original equipment manufacturer), and Air Liquide (AL – air separation experts). The specific objectives of the project were to: (1) Evaluate the SPOC concept and develop a risk-based approach to the heating surface layout ensuring that performance (gas and steam side), manufacturing, transportation, and plant erection considerations were fully accounted for in the system design. (2) Improve the technology to ensure its performance and cost potential are substantially better than today’s baseline pulverized coal power plant with post-combustion capture (PCC) or atmospheric oxy-combustion, and show progress toward performance commensurate with projected commercial operation, including 90% or more CO 2 capture. (3) Address critical technology gaps and improving overall system performance for the technology. (4) Perform combustion tests at scale under commensurate pressure to the commercial operating system validate combustor and advance the SPOC combustion modeling tools that will facilitate full-scale design. Combustion Testing: Testing was initially carried out at atmospheric pressure with methane to ensure that all systems were correctly operating. Following this, the testing then proceeded to moderate pressure operation at 4 bara, where different stoichiometric conditions were used across an extended heat input range, showing that a stable flame could be maintained. Testing then proceeded at 10 and 15 bara where it was shown that the ignition system needed to be replaced at these operating conditions. When testing recommenced, a similar stable flame shape was achieved, without any methane support, and the full 100 kWth coal oxy-combustion was demonstrated. Heat flux measurements showed 400 kW/m 2 (0.126 MMBtu/hr-ft 2 ) from the flame, within the 450 kW/m 2 (0.142 MMBtu/hr-ft 2 ) preferred limit defined by DBL for the full-scale design case. Carbon monoxide and carbon-in-ash measurements showed that complete combustion was possible with ultra-low excess oxygen at 1 vol % in the product flue gas. This allowed the full-scale models to be calculated based on this level of excess oxygen, improving the performance of the system as lower feed oxygen is produced in the air separation unit (ASU), saving auxiliary power. Full-Scale Design: The full-scale design is sized to deliver 550 MWe net electrical power output to allow direct comparison with the National Energy Technology Laboratory (NETL) baseline cases using the same Montana Powder River Basin (PRB) fuel. The cases used for direct comparison are: Case S12A (supercritical [SC] coal without CO 2 capture), Case S12B (SC coal with PCC at 90% CO 2 capture, and Case S12F (atmospheric oxy-combustion SC coal with 90% CO 2 capture). The SPOC stages were configured to be identical arrangements, allowing for a more straightforward design, construction, and control strategy. Each stage consists of two PVs, the first being the combustor PV module and the second being the convective PV module. The combustor module is the tallest vessel, with local coal feeding equipment and the burner FGR and oxygen plenums at the top and ash management at the bottom. The combustor module is effectively an open cross section with membrane tubes around the circumference – this unobstructed slender profile ensures that the relatively slower burnout mechanism needed for the low-speed turbulent mixing burner can proceed unimpeded and that molten ash will not attach to any surfaces at an angle to the predominant flue gas flow. The steam turbine used in the SPOC design is essentially the same unit utilized in the atmospheric oxy-combustion case except the degree of heat recovery possible allows the low-pressure (LP) feedwater heater train to be eliminated. This is a result of being able to capture the latent heat of evaporation of the moisture produced in the combustion (normally lost to the stack). The SPOC system outperforms the NETL atmospheric oxy-combustion baseline case by 3.3% points and the PCC case by 7.5% points. This performance increase is mainly a result of the improved heat recovery possible from the product flue gas and from the reduced auxiliary power consumption from the ASU and the CO 2 compression and purification unit over the atmospheric equivalent. The combined improvement in boiler efficiency and reduction in the steam turbine heat rate resulted in a net improvement in the overall plant efficiency by 0.61%, to 35.6% on a HHV basis. This relatively small improvement in plant efficiency between sub-bituminous and bituminous coals shows the value of useful moisture latent heat recovery offered by the SPOC system when using low rank fuels. Flexibility and Turndown: The SPOC system has inherent high turndown capabilities because of a demonstrated high range of combustion stability and the ability to bypass stages, thereby reducing steam generation rates proportionally without altering firing rates in operating stages. ASU units do not generally offer significant turndown opportunities as they are limited by the performance of the compression plant. The baseline SPOC design has a 2-train ASU configuration, needed to be able to meet the 10,500 tonnes per day duty, that can deliver efficient turndown points between 85–100% load with both trains operating, and at 45–50% load with a single train operating. Outside these operating points, the flexibility and efficiency are limited and may be uncompetitive at loads below 45% as the ASU systems are unable to turndown beyond 85% for the base case and 70% for the flexible case. The ASU cold box for the flexible case was designed to operate at loads between 40-100%, below this operating range the purity of the produced oxygen cannot be guaranteed, resulting in additional load for the CPU equipment. The additional power consumption of these cases yields an uneconomic operating condition with poor efficiency when operating at low loads such as 25% and 12%. To address this flexibility constraint, AL evaluated how the ASU configuration could be altered to deliver efficient oxygen supply over the load range. This involved integrating the compressor duties across both ASU trains into a shared duty arrangement with multiple compressors, strategically sized to deliver the duty required across all load ranges between 40–100% by enabling different combinations of the main air compressors and the booster air compressors. The oxygen purity cannot be guaranteed below 40% load for each train – the power consumption at 25% and 12% loads were estimated based on the multi-compressor configuration at maximum turndown as these load cases were not considered in the flexible ASU design. With a different cold box configuration, i.e. number of trains, the entire load range could be delivered within oxygen purity specifications. Although there is a small efficiency reduction at full load, there are significant improvements in overall plant performance during low-load operation. The exact ASU configuration needed will therefore be dependent on the expected operating profile of the unit. Economic Analysis: Cost estimates for the baseline and the flexible cases were developed using NETL baseline case data for common BOP items and an Association for the Advancement of Cost Engineering International Class 5 (conceptual/screening study) assessment of key components unique to the SPOC system. The capital, operating, and maintenance costs were assessed along with the first-year power cost, levelized cost of electricity, and CO 2 captured and avoided cost for the SPOC cases were compared against the relevant NETL baseline cases in January 2019 dollars. Both SPOC cases achieve a lower cost that the alternative NETL baseline cases (with the flexible SPOC case being slightly higher than the baseline SPOC case due to the compounded impact of higher capital costs and lower efficiency at full load). The SPOC cases deliver a lower cost of CO 2 avoided than the NETL baseline cases due to greater efficiency in generating low-carbon power. However, the cost of CO 2 captured is higher because the higher efficiency of the SPOC process generates less CO 2 , hence less needs to be captured, resulting in a high capital cost being shared over a reduced CO 2 quantity. The flexible ASU adds 1.6% overall to the plant cost in comparison to the baseline case, but the efficiency improvements at loads below 50% are significant. Subsequently, depending on the plant load-profile expectation, the flexible ASU would be beneficial if the plant spends a significant portion of its operating life below 50% load. This kind of operating profile is likely to be required for all fossil plants when more renewable electricity generators are installed on the local grid, particularly solar power that can be predicted ahead of time, allowing for appropriate pricing signals to be incorporated into the diurnal cycle. R&D Recommendations: SPOC, while a promising technology, is a relatively recent concept and, as such, operability issues of combustor design and steam-side integration for such systems at a scale relevant to commercial deployment have not been evaluated. WUSTL has conducted extensive small pilot-scale (100 kWth) research to understand and advance pressurized oxy-combustion processes, including investigation of combustion and flame characteristics, radiative heat flux, burner operability, turn down, char burnout, ash characteristics, water-wash column operation, etc. for pressurized oxy-combustion systems. Nonetheless, at this stage in the development of the SPOC process, what is needed is a large-scale pilot plant that can serve to study pressurized oxy-combustion systems and components at a scale commensurate with the maturity of the technology. A scale of 10 MWth, which includes steam-side integration and two stages would yield essential information with respect to heat transfer characteristics both in the radiative and convective sections of the pressure vessels, and the ability to operate the fuel staging process. In addition, while modeling results indicate that combustion and flame characteristics improve with scale, direct studies of the combustor at this scale will ensure that the models can be relied upon for scale up to commercial scale. Furthermore, a detailed analysis must be performed to understand the scaling aspects of key components and systems.

20 FOSSIL-FUELED POWER PLANTS↗

Dynamic simulation and techno-economic analysis of a concentrated solar power (CSP) plant hybridized with both thermal energy storage and natural gas

The addition of thermal energy storage and natural gas as a complementary energy source improves the flexibility, reliability, and value of concentrated solar power (CSP) plants. Nevertheless, due to the transient nature of solar energy, transitions from solar-only mode and natural-gas mode to hybrid solar-natural gas mode is quite challenging, especially when the plant is equipped with thermal storage. Thus, it is important to develop proper dynamic modeling and control schemes to accurately simulate such transitions. The objective of this study is to address this subject by demonstrating a dynamic model with reliable control schemes for a highly integrated hybrid parabolic trough-natural gas plant equipped with thermal energy storage. The specific goal is to study the dynamics of adding thermal storage to the hybrid plant. It is found that the developed control schemes assist smooth transitions between different operational modes and effective utilization of thermal storage and natural gas to maintain steady power production and steam mass flow rates under different solar conditions. The results demonstrate that the integration of storage regulates power production by solar energy and natural gas during the day time. It also enables an increase in the solar fraction of the hybrid plant while it causes a small decrease in thermodynamic efficiency. The analysis shows that the hybrid plant with the storage has a substantially lower specific CO 2 emission (0.320 tonne/MWh) than single natural gas plant (0.413 tonne/MWh) although it has a higher levelized cost of electricity (86.32/MWh against 74.92/MWh). The hybrid plant with storage demonstrates a promising potential for reliable and clean production of electricity, although research and development should be conducted to lower its cost.

03 NATURAL GAS↗

Data Projection of the High Temperature Electrolysis System in the Dynamic Energy Transport and Integration Laboratory using Dynamic System Scaling

For nuclear power to be flexible in a functioning Integrated Energy System (IES), excess produced heat must be stored or utilized during times of low power demand to ensure a load factor of 1 while load balancing. The Dynamic Energy Transport and Integration Laboratory (DETAIL) is one facility that is under development to emulate IES conditions on the engineering-scale, planned to conduct virtual real time operations with industry-scale facilities, and is currently testing thermal storage and high temperature electrolysis. As part of the study to develop a method to preprocess input signals or postprocess output signals between systems of different scales via Dynamical System Scaling (DSS), the current research is one of the continued efforts branching from the data projection activity conducted for the Thermal Energy Distribution System and currently engages the High Temperature Electrolysis (HTE) System in DETAIL. The HTE SOEC electrical, fluid, and thermal dynamics Figure of Merits (FOM) were identified, governing equations and closure relations were successfully scaled, and relations between FOM scaling ratios were determined. Setting the scaling objectives to reform existing data to project a data set that doubly accelerated the electrolysis process while preserving the produced amount of hydrogen was generated for the full transient. The calculated boundary conditions were inlet temperature, stack current, and inlet steam mass flow rate at 1470 K, 121.1 A, and 1.886 g/s, respectively. The research outcomes demonstrated an output signal postprocessing case accelerating the hydrogen production without changing geometry, number of cells, and partial pressures.

08 HYDROGEN↗