Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “station use”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Estimate of procession and polar motion errors from planetary encounter station location solutions

Jet Propulsion Laboratory Deep Space Station (DSS) location solutions based on two JPL planetary ephemerides, DE 84 and DE 96, at eight planetary encounters were used to obtain weighted least squares estimates of precession and polar motion errors. The solution for precession error in right ascension yields a value of 0.3 X 10 to the minus 5 power plus or minus 0.8 X 10 to the minus 6 power deg/year. This maps to a right ascension error of 1.3 X 10 to the minus 5 power plus or minus 0.4 X 10 to the minus 5 power deg at the first Voyager 1979 Jupiter encounter if the current JPL DSS location set is used. Solutions for precession and polar motion using station locations based on DE 84 agree well with the solution using station locations referenced to DE 96. The precession solution removes the apparent drift in station longitude and spin axis distance estimates, while the encounter polar motion solutions consistently decrease the scatter in station spin axis distance estimates.

Pease, G. E.↗

Modal Test/Analysis Correlation of Space Station Structures Using Nonlinear Sensitivity

The modal correlation problem is formulated as a constrained optimization problem for validation of finite element models (FEM's). For large-scale structural applications, a pragmatic procedure for substructuring, model verification, and system integration is described to achieve effective modal correlation. The space station substructure FEM's are reduced using Lanczos vectors and integrated into a system FEM using Craig-Bampton component modal synthesis. The optimization code is interfaced with MSC/NASTRAN to solve the problem of modal test/analysis correlation; that is, the problem of validating FEM's for launch and on-orbit coupled loads analysis against experimentally observed frequencies and mode shapes. An iterative perturbation algorithm is derived and implemented to update nonlinear sensitivity (derivatives of eigenvalues and eigenvectors) during optimizer iterations, which reduced the number of finite element analyses.

Gupta, Viney K.↗

Modal test/analysis correlation of Space Station structures using nonlinear sensitivity

The modal correlation problem is formulated as a constrained optimization problem for validation of finite element models (FEM's). For large-scale structural applications, a pragmatic procedure for substructuring, model verification, and system integration is described to achieve effective modal correlations. The space station substructure FEM's are reduced using Lanczos vectors and integrated into a system FEM using Craig-Bampton component modal synthesis. The optimization code is interfaced with MSC/NASTRAN to solve the problem of modal test/analysis correlation; that is, the problem of validating FEM's for launch and on-orbit coupled loads analysis against experimentally observed frequencies and mode shapes. An iterative perturbation algorithm is derived and implemented to update nonlinear sensitivity (derivatives of eigenvalues and eigenvectors) during optimizer iterations, which reduced the number of finite element analyses.

Gupta, Viney K.↗

An assessment of the microgravity and acoustic environments in Space Station Freedom using VAPEPS

The Vibroacoustic Payload Environment Prediction System (VAPEPS) was used to predict the stationary on-orbit environments in one of the Space Station Freedom modules. The model of the module included the outer structure, equipment and payload racks, avionics, and cabin air and duct systems. Acoustic and vibratory outputs of various source classes were derived and input to the model. Initial results of analyses, performed in one-third octave frequency bands from 10 to 10,000 Hz, show that both the microgravity and acoustic environments will be exceeded in some one-third octave bands with the current SSF design. Further analyses indicate that interior acoustic level requirements will be exceeded even if the microgravity requirements are met.

Bergen, Thomas F.↗

Estimating the urban bias of surface shelter temperatures using upper-air and satellite data. Part 2: Estimation of the urban bias

A methodology is presented for estimating the urban bias of surface shelter temperatures due to the effect of the urban heat island. Multiple regression techniques were used to predict surface shelter temperatures based on the time period 1986-89 using upper-air data from the European Centre for Medium-Range Weather Forecasts (ECMWF) to represent the background climate, site-specific data to represent the local landscape, and satellite-derived data -- the normalized difference vegetation index (NDVI) and the Defense Meteorological Satellite Program (DMSP) nighttime brightness data -- to represent the urban and rural landscape. Local NDVI and DMSP values were calculated for each station using the mean NDVI and DMSP values from a 3 km x 3 km area centered over the given station. Regional NDVI and DMSP values were calculated to represent a typical rural value for each station using the mean NDVI and DMSP values from a 1 deg x 1 deg latitude-longitude area in which the given station was located. Models for the United States were then developed for monthly maximum, mean, and minimum temperatures using data from over 1000 stations in the U.S. Cooperative (COOP) Network and for monthly mean temperatures with data from over 1150 stations in the Global Historical Climate Network (GHCN). Local biases, or the differences between the model predictions using the observed NDVI and DMSP values, and the predictions using the background regional values were calculated and compared with the results of other research. The local or urban bias of U.S. temperatures, as derived from all U.S. stations (urban and rural) used in the models, averaged near 0.40 C for monthly minimum temperatures, near 0.25 C for monthly mean temperatures, and near 0.10 C for monthly maximum temperatures. The biases of monthly minimum temperatures for individual stations ranged from near -1.1 C for rural stations to 2.4 C for stations from the largest urban areas. The results of this study indicate minimal problems for global application once global NDVI and DMSP data become available.

Epperson, David L.↗

Berthing of Space Station Freedom using the shuttle remote manipulator system

A large-angle, flexible, multi-body, dynamic modeling capability was developed to help validate analytical simulations of the dynamic motion and control forces which occur while berthing of Space Station Freedom to the Shuttle Orbiter during early assembly flights. The dynamics and control of the station, the attached Shuttle Remote Manipulator System, and the Orbiter during a berthing maneuver are described. Emphasis is placed on the modeling of the Shuttle Remote Manipulator System in the multi-body simulation. The influence of the elastic behavior of the station and of the Remote Manipulator System on the attitude control of the station/Orbiter system during the maneuver is investigated.

Cooper, Paul↗

An Overview of the Integrated Crate Interrogation System (ICIS) for use at the Savannah River Site

The Integrated Crate Interrogation System (ICIS) was developed for use at the Savannah River Site to assay transuranic waste in large containers. The system comprises a Box Segmented Gamma Scanner (BSGS) providing high resolution gamma spectroscopy, and a Box Neutron Assay System (BNAS) providing passive neutron counting capability. The multi-modality approach is taken where the assay results from the gamma and neutron systems are combined to complement each other in satisfying Waste Isolation Pilot Plant (WIPP) criteria. This paper gives an overview of the system that has been built, factory calibrated, and delivered to the site. The BSGS is similar to a standard Canberra Segmented Gamma Box Counter, but with the addition of a transmission option for ascertaining density and rudimentary fill-height information. This supplements the Multi-Curve approach based on efficiency in energy and density. The BSGS has a moving trolley which travels on rails through a passive emission counting station using large BEGe detectors, and a transmission counting station using NaI detectors in conjunction with high- and low-beam transmission stages. The assay result provides information on the Pu, Am and/or U isotopic ratios using standard isotopic analysis codes, quantitative measurement of Pu and U for low and medium density matrices, and direct measurement of other gamma emitters in the waste that are not identified in the isotopic measurement. It also provides basic positional information to improve the accuracy of both the gamma and the neutron measurement. The BNAS is a passive neutron coincidence counter intended for use with multiplicity counting of items of various geometries. The counter utilizes 320 {sup 3}He filled proportional counters arranged in a 4 {pi} geometry about the assay cavity and divided into 80 counting channels. The assay result provides the {sup 240}Pu-effective mass with which the gamma isotopic measurement is combined to provide reliable reporting of Pu and other isotopes. It also provides the total alpha activity that must be reported as part of the characterization requirements for WIPP (or bounds on the alpha activity based on the chemical form of the alpha-emitter). The neutron assay also complements the gamma results where matrix effects, self shielding or self absorption effects, and the presence of high-Z material, severely limits accuracy. Matrix moderator corrections for the neutron assay are based on a multi-position Add-A-Source correction augmented by a Modified Hydrogen Correction. The data acquisition also incorporates a Local Coincidence Veto circuit. Following the calibration of the system at the factory, confirmatory measurements were performed to demonstrate the validity of the calibrations, and to verify that the measurement system meets the Waste Acceptance Criteria established by DOE/WIPP. (authors)

54 ENVIRONMENTAL SCIENCES↗

Coherent lidar wind measurements from the Space Station base using 1.5 m all-reflective optics

This paper discusses the space-based measurement of atmospheric winds from the point of view of the requirements of the optical system of a coherent CO2 lidar. A brief description of the measurement technique is given and a discussion of previous study results provided. The telescope requirements for a Space Station based lidar are arrived at through discussions of the desired system sensitivity and the need for lag angle compensation.

Bilbro, J. W.↗

Test results from LAGEOS-2 optical characterization using pulsed lasers

The Laser Geodynamic Satellite-2 (LAGEOS-2) has undergone extensive optical testing at NASA Goddard Space Flight Center during 1989. The techniques included measuring the far field diffraction pattern using cw and pulsed lasers. In the pulsed measurement technique, response of the satellite was studied by measuring the far-field diffraction pattern (FFDP) as a function of pulsewidth, wavelength, polarization, position in the FFDP, detector/processing techniques, and satellite orientation. The purpose of the pulsed laser testing was two-fold: (1) to characterize the satellite optical response with the detector and signal processing electronics currently used in most SLR stations using the portable laser ranging standard, and (2) to characterize the satellite response for various conditions using the highest bandwidth optical detector (streak camera) available for the next generation of satellite laser ranging (SLR) technology. The portable ranging standard employed multiple measurement devices and an optical calibration scheme to eliminate range-dependent and amplitude-dependent systematics. These precautions were taken to eliminate/minimize instrumental errors and provide maximum accuracy. For LAGEOS orbit (6000 Km), ground stations are located 34 to 38 Mu radians off the axis of the return signal from the satellite; therefore, an optical mask was used to restrict the field of view (FOV) of detection to this annular region of the FFDP. The two measurement techniques were implemented using an aperture sharing scheme and complemented each other by providing mutual verification.

Varghese, Thomas K.↗

The laser shock station in the dynamic compression sector. I

The Laser Shock Station in the Dynamic Compression Sector [Advanced Photon Source (APS), Argonne National Laboratory] links a laser-driven shock compression platform with high energy x-ray pulses from the APS to achieve in-situ, time-resolved x-ray measurements (diffraction and imaging) in materials subjected to well-characterized, high stress, short duration planar shock waves. Additionally, the combination of this station and the other DCS experimental stations provides a unique and versatile experimental facility to study condensed state phenomena by undertaking real-time, multi-scale measurements in materials subjected to a wide range of shock amplitudes (to above ~350 GPa) and time-durations (~10 ns to 1 μs). The Laser Shock Station uses a 100 joule, 5-17 ns, 351 nm frequency tripled Nd:glass laser with programmable pulse shaping and focal profile smoothing for maximum precision. The laser is capable of a shot every 30 minutes. The interaction chamber contains multiple ports for simultaneous diagnostics, a sample holder that allows sequential exposure for 14 samples without breaking vacuum, the capability to vary the angle between the x-ray beam and laser beam by 135°, and the ability to translate to select one of two types of x-ray beams. X-ray data can be taken with a temporal resolution of ~90 psec. Highly reproducible, planar shocks can be propagated in samples to undertake precise and well-characterized experiments. In a series of ten shots, the absolute variation in the time the shock breaks out at the back of the sample is less than 500ps and the variation in peak particle velocity at the sample/window interface is 4.3%. Lastly, this paper describes the entire DCS Laser Shock Station, including sample fabrication and diagnostics, as well as representative experimental results from shock compressed tantalum to demonstrate the excellent quality of x-ray diffraction data in solid tantalum and to establish the stress for tantalum melting.

47 OTHER INSTRUMENTATION↗

VHF downline communication system for SLAR data

A real time VHF downlink communication system is described for transmitting side-looking airborne radar (SLAR) data directly from an aircraft to a portable ground/shipboard receiving station. Use of this receiving station aboard the U.S. Coast Guard icebreaker Mackinaw for generating real-time photographic quality radar images is discussed. The system was developed and demonstrated in conjunction with the U.S Coast Guard and NOAA National Weather Service as part of the Project Icewarn all weather ice information system for the Great Lakes Winter Navigation Program.

Schertler, R. J.↗

VHF downlink communication system for SLAR data

This paper describes a real-time VHF downlink communication system for transmitting side-looking airborne-radar (SLAR) data directly from an aircraft to a portable ground/shipboard receiving station. Use of this receiving station aboard the U.S. Coast Guard icebreaker Mackinaw for generating real-time photographic quality radar images will be discussed. The system was developed and demonstrated in conjunction with the U.S. Coast Guard and NOAA National Weather Service as part of the Project Icewarn all-weather ice information system for the Great Lakes Winter Navigation Program.

Schertler, R. J.↗