Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectrum monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Laboratory Instrument Software Controlled Spread Spectrum Time Domain Reflectometry for Electrical Cable Testing

This research discusses development of a software-controlled laboratory instrument based spread spectrum time domain reflectometry system (SSTDR). This constitutes one task within PNNL’s Light Water Sustainability Program (LWRS) whose mission includes advancing nondestructive examination (NDE) techniques for off-line and on-line in-situ cable condition monitoring. In 2022, PNNL evaluated SSTDR for detection and characterization of a number of cable anomalies (Glass et al. 2022). The review included comparison of SSTDR to Frequency Domain Reflectometry (FDR) techniques which have enjoyed encouraging feedback and are starting to be used in nuclear power plants for periodic cable condition monitoring of cable systems as part of the plant’s overall cable aging management program. The FDR test introduces a broad-band chirp onto the cable at the cable end then listens for any reflection from a change of impedance along the cable caused by a damaged conductor or insulation, splices, contact with moisture, or other cable anomalies. The signal is captured in the frequency domain then transformed back to the time domain using an inverse Fourier transform (IFT). Based on the velocity of propagation, the impedance response signal is plotted against distance along the cable. Peak locations along the X-axis indicate the distance along the cable where a portion of the signal has been reflected back to the instrument as a result of a cable anomaly. The FDR test is considered the gold standard of reflectometry however it does require the cable to be de-energized to perform the test. The LIVEWIRE commercial SSTDR produces a similar plot to the FDR however all processing is in the time domain. A pseudo-random noise code (PN code) is input onto the cable conductor and the instrument listens for any reflected response from cable anomalies. The SSTDR processes the signal as an autocorrelation comparing the input PN code to any reflected signal detected. The autocorrelation analysis for thermal aging, water and water ingress detection, ground fault and phase-to-phase fault detection at various locations along the cable and with the cable attached and detached from a motor load, and on both energized and un-energized conditions were performed. These results were contrasted to Frequency Domain Reflectometry (FDR) measurements of the un-energized cable. Results were encouraging but indicated more work was warranted – particularly with the SSTDR, it seemed that the insulation damage would likely be better evaluated with multiple bandwidth cable tests particularly including larger bandwidths than were possible with the current commercial instrument. The commercial instrument’s bandwidth was set at 6, 12, 24, and 48MHz but note that SSTDR and FDR definitions of bandwidth trend similarly but are not the same. The FDR response could be more broadly adjusted, and the bandwidth of 100 to 500 MHz produced the best responses. FDR responses to anomalies were clearer than SSTDR responses and indications were that a broader bandwidth SSTDR may lead to improved SSTDR detection capability. This project used a laboratory instrument based SSTDR (primarily using an Arbitrary Waveform Generator (AWG) and a digital oscilloscope plus Python in-house software) that allowed software adjustment of the SSTDR bandwidth, window functions applied to the exciting Pseudo-random Noise (PN) code plus and other aspects of the SSTDR signal processing. Hereafter, this will be referred to as the PNNL SSTDR. Evaluating specific performance of the PNNL SSTDR is left to a separate report. This report documents hardware and software development to produce the SSTDR cable test system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evaluation of Raman scattering as a sensor of temperature and molecular density

The performance of the Raman scattering technique for the remote monitoring of temperature and molecular number density in various wind tunnel and engine testing facilities has been experimentally evaluated. Temperature measurements were made by monitoring the pure rotational spectrum of nitrogen and the rotational branch separations of nu2 of CF4 for temperatures in the range 300 to 1000 K. These measurements yielded an average error of 2.6 and 7.6%, respectively, for temperature measurements at pressures near 1 atm. Molecular number density measurements with 20% error could be made at densities as low as 3.5 times 10 to the 22-nd power per cu m by monitoring the 6 to 8 rotational transition of nitrogen, 3.5 times 10 to the 23-rd power per cu m by monitoring the Q-branch of the fundamental vibrational transition of nitrogen, and 7 times 10 to the 22-nd power per cu m by monitoring the nu1 fundamental vibrational transition of CF4.

Bandy, A. R.↗

Rigidity spectrum of Forbush decrease

Using data from neutron monitors and muon telescopes at surface and underground stations, the average rigidity spectrum of Forbush decreases (Fds) during the period of 1978-1982 were obtained. Thirty eight Ed-events are classified into two groups Hard Fd and Soft Fd according to size of Fd at Sakashita station. It is found that a spectral form of fractional-power type (P to the-gamma sub 1 (P+P sub c) to the -gamma sub2) is more suitable for the present purpose than that of power-exponential type or of power type with an upper limiting rigidity. The best fitted spectrum of fractional-power type is expressed by gamma sub1 = 0.37, gamma sub2 = 0.89 and P subc = 10 GV for Hard Fd and gamma sub1 = 0.77, gamma sub2 = 1.02 and P sub c - 14GV for Soft Fd.

Sakakibara, S.↗

An In Situ Feed Monitoring System for Molten Salt Reactors with Fast Neutron Energy Spectrum Molten Salt Reactor Applications

Molten salt reactors (MSRs) are one of the six promising advanced reactor technologies selected for further research and development by the Generation IV International Forum. More than twenty MSR designs are actively being developed around the world. Several of these designs are liquid-fueled and intended for operation within the fast neutron energy spectrum.1 National regulations will require liquid-fueled MSRs to control and account for nuclear material within licensed facilities. Additionally, states with comprehensive safeguards agreements with the International Atomic Energy Agency (IAEA) are obligated to declare nuclear material quantities within facilities. In return, the IAEA Department of Safeguards independently verifies these quantities and provides assurance that the nuclear material and facility are being used only for peaceful purposes. One key distinction of liquid-fueled MSRs compared with other types of reactors is that in portions of the facility, the nuclear material is in bulk form rather than discrete items. Traditional nuclear material accounting techniques such as physical item counting and verification of serial numbers on fresh fuel assemblies do not translate directly to all process streams within liquid-fueled reactors. Liquid-fueled MSRs are typically designed with low excess reactivity. This feature provides safety benefits but also means that most MSRs require the addition of makeup fuel salt while a reactor is operational. The nuclear material in the initial fuel salt and in any makeup fuel salt must be quantified. Additionally, distinct nuclear material diversion and reactor misuse scenarios form the basis of the detection methods and monitoring systems developed for liquid-fueled MSRs. For example, the IAEA provides assurance that fuel salt containing nuclear material is not being diverted from the system, that the feed salt matches the reported actinide concentrations and uranium enrichment, and that no additional fertile material is being introduced into the system. Measurement systems currently used for nuclear material control and accounting are not directly applicable to achieving MSR safeguards goals. This paper concerns a system being designed to account for the nuclear material added to liquid-fueled MSRs and monitor for diversion and misuse scenarios related to MSR feed systems.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Feasibility study on real-time {gamma}-ray spectrum / dose measurement system

In recent years, radiations have been used very often especially in the medical field. Radiation protection is carried out properly there. However, the medical staffs sometimes focus not so seriously on their exposure dose, because treatment of patients is the first priority in hospitals. In the past study, there were radiation monitors developed which can indicate the pulse height spectrum and/or dose. However, there were no monitors which can show the gamma-ray energy spectrum and dose at the same time. A monitor, which we design, can estimate the energy spectrum of gamma-rays in the medical atmosphere, with which the dose can be evaluated simultaneously and accurately. The purpose of this study is to develop a spectrometer (monitor) which can show gamma-ray spectrum / dose simultaneously in real time to make the medical staffs understand the risk of radiation precisely and to finally decrease their exposure dose. For this purpose we newly developed a conversion procedure from the measured pulse height spectrum to energy spectrum in real time. The details are also described in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New aspects of longitudinal instabilities in electron storage rings

Here, novel features of the longitudinal instability of a single electron bunch circulating in a low-emittance electron storage ring are discussed. Measurements and numerical simulations, performed both in time and frequency domain, show a non-monotonic increase of the electron beam energy spread as a function of single bunch current, characterized by the presence of local minima and maxima, where a local minimum of the energy spread is interpreted as a higher-order microwave instability threshold. It is also shown that thresholds related to the same zero-intensity bunch length depend linearly on the accelerating radio frequency voltage. The observed intensity-dependent features of the energy spread, confirmed by measurements with two independent diagnostics methods, i.e. horizontal beam profile measurements by a synchrotron light monitor and photon energy spectrum measurements of undulator radiation, are given a theoretical interpretation by applying a novel eigenvalue analysis based on the linearized Vlasov equation.

43 PARTICLE ACCELERATORS↗

Extended fast-ion D-alpha diagnostic on DIII-D

A fast-ion deuterium-alpha (FIDA) diagnostic, first commissioned on DIII-D in 2005, relies on Doppler-shifted light from charge-exchange between beam neutrals and energetic ions. The second generation (2G) system was installed on DIII-D in 2009. Its most obvious improvement is the spatial coverage with 11 active in-beam and three passive off-beam views; the latter allows for simultaneous monitoring of the background signal. Providing extended coverage in fast-ion velocity space, the new views possess a more tangential component with respect to the toroidal field compared to their first generation counterparts. Each viewing chord consists of a bundle of three 1.5 mm core fibers to maximize light gathering. For greater throughput, fast f/1.8 optical components are used throughout. The signal is transmitted via fiber optics to a patch panel, so the user is able to choose the detector. FIDA was originally installed with a spectrometer and charge-coupled device (CCD) camera to monitor the full D{sub {alpha}} spectrum for two spatial views. 2G adds another spectrometer and CCD that monitor the blue-shifted wing for six spatial views at 1 kHz. In addition, a photomultiplier tube and fast digitizer provide wavelength-integrated signals at 1 MHz for eight spatial views.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DETECTION OF A THERMAL SPECTRAL COMPONENT IN THE PROMPT EMISSION OF GRB 100724B

Observations of GRB 100724B with the Fermi Gamma-Ray Burst Monitor find that the spectrum is dominated by the typical Band functional form, which is usually taken to represent a non-thermal emission component, but also includes a statistically highly significant thermal spectral contribution. The simultaneous observation of the thermal and non-thermal components allows us to confidently identify the two emission components. The fact that these seem to vary independently favors the idea that the thermal component is of photospheric origin while the dominant non-thermal emission occurs at larger radii. Our results imply either a very high efficiency for the non-thermal process or a very small size of the region at the base of the flow, both quite challenging for the standard fireball model. These problems are resolved if the jet is initially highly magnetized and has a substantial Poynting flux.

79 ASTRONOMY AND ASTROPHYSICS↗

Molecular-ion trap-depletion spectroscopy of BaCl{sup +}

We demonstrate a simple technique for molecular-ion spectroscopy. BaCl{sup +} molecular ions are trapped in a linear Paul trap in the presence of a room-temperature He buffer gas and photodissociated by driving an electronic transition from the ground X {sup 1}{Sigma}{sup +} state to the repulsive wall of the A {sup 1}{Pi} state. The photodissociation spectrum is recorded by monitoring the induced trap loss of BaCl{sup +} ions as a function of excitation wavelength. Accurate molecular potentials and spectroscopic constants are determined. A comparison of the theoretical photodissociation cross sections with the measurements shows excellent agreement. This study represents an important step toward the production of ultracold ground-state molecular ions.

74 ATOMIC AND MOLECULAR PHYSICS↗

Internal hysteresis experienced on a high pressure syn gas compressor

A vibration instability phenomenon experienced in operating high pressure syn gas centrifugal compressors in two ammonia plants is described. The compressors were monitored by orbit and spectrum analysis for changes from baseline readings. It is found that internal hysteresis was the major destabilizing force; however, the problem was further complicated by seal lockup at the suction end of the compressor. A coupling lockup problem and a coupling fit problem, which frettage of the shaft, are also considered as contributors to the self excited vibrations.

Zeidan, F. Y.↗

The Magneto-optical Filter, Working Principles and Recent Progress

The Magneto-Optical Filter is described which allows simultaneous magnetic and velocity measurements (in both imaging and non-imaging modes) without the need for a spectrograph. In this way the stability and alignment problems of the spectrograph are completely overcome. Its major advantages are: wavelength absolute reference and stability, high signal to noise ratio and independence of the transmission profile from the incidence angle of the solar beam. It is an imaging instrument allowing high wave number analysis in the solar oscillation spectrum and a continuous monitoring of the image position through the chromospheric facular structures. The apparatus in use at Mt. Wilson is assembled in a modular form. The most important part of it is a glass cell containing the sodium vapor. The filter is easy to use but the cell is not easy to construct in an optimal way. The technology is in progress both to use Na and K together and to prevent the windows from becoming coated during a long-term operation.

Cacciani, A.↗

Improved Measurement of Dispersion in an Optical Fiber

An improved method of measuring chromatic dispersion in an optical fiber or other device affords a lower (relative to prior such methods) limit of measurable dispersion. This method is a modified version of the amplitude-modulation (AM) method, which is one of the prior methods. In comparison with the other prior methods, the AM method is less complex. However, the AM method is limited to dispersion levels . 160 ps/nm and cannot be used to measure the symbol of the dispersion. In contrast, the present modified version of the AM method can be used to measure the symbol of the symbol of the dispersion and affords a measurement range from about 2 ps/nm to several thousand ps/nm with a resolution of 0.27 ps/nm or finer. The figure schematically depicts the measurement apparatus. The source of light for the measurement is a laser, the wavelength of which is monitored by an optical spectrum analyzer. A light-component analyzer amplitude-modulates the light with a scanning radio-frequency signal. The modulated light is passed through a buffer (described below) and through the device under test (e.g., an optical fiber, the dispersion of which one seeks to measure), then back to the light-component analyzer for spectrum analysis. Dispersion in the device under test gives rise to phase shifts among the carrier and the upper and lower sideband components of the modulated signal. These phase shifts affect the modulation-frequency component of the output of a photodetector exposed to the signal that emerges from the device under test. One of the effects is that this component goes to zero periodically as the modulation frequency is varied.

Huang, Shouhua↗

Automatic radio-transmission monitor

System continuously monitors radio transmissions stored in memory. If spectrum deviates beyond present limits, alarm is tripped and spectrum is transferred to long-term storage for later analysis. Monitor can be useful in ensuring proper power level and spectral quality and in finding cause of failure. It might also be used to monitor radio-frequency interference or power levels of citizen's-band transmitters.

Bernstein, A. J.↗

IUE observations of Comet Halley: Evolution of the UV spectrum between September 1985 and July 1986

The ultraviolet spectrum of comet P/Halley was monitored with the IUE between 12 September 1985 and 8 July 1986 (r <2.6 AU pre and post-perihelion) at regular time intervals except for a two-month period around the time of perihelion. A complete characterization of the UV spectrum of the comet was obtained to derive coma abundances and to study the light emission mechanisms of the observed species. The Fine Error Sensor (FES) camera of the IUE was used to photometrically investigate the coma brightness variation on time scales of the order of hours. Spectroscopic observations as well as FES measurements show that the activity of the nucleus is highly variable, particularly at the end of December 1985 and during March and April 1986. The production rates of OH, CS and dust are derived for the entire period of the observations. The total water loss rate for this period is estimated to be 150 million metric tons.

Feldman, P. D.↗

Cosmic ray scintillations. III - The low-frequency limit and observations of interplanetary scintillations

Statistically significant broad-band fluctuations, or 'scintillations', in the high-energy (about 1 GeV) cosmic ray intensity observed by neutron monitors are interpreted. The scintillations are caused by fluctuations in the interplanetary magnetic field. The theory of the scintillations is presented for the low-frequency limit, below .0001 Hz, including the effects of the earth's rotation on the fluxes observed by the neutron monitors. The observations and the theory are in good agreement. The shapes and amplitudes of the observed spectra and, in particular, a broad enhancement in the power spectrum of the Deep River neutron monitor flux near 1 cpd are related to the interplanetary magnetic field power spectrum and the cosmic ray anisotropy.

Owens, A. J.↗

Development of a time-resolved soft x-ray spectrometer for laser produced plasma experiments

A 2400 lines/mm variable-spaced grating spectrometer has been used to measure soft x-ray emission (8-22 A) from laser-produced plasma experiments at Lawrence Livermore National Laboratory's Compact Multipulse Terrawatt (COMET) Laser Facility. The spectrometer was coupled to a Kentech x-ray streak camera to study the temporal evolution of soft x rays emitted from the back of the Mylar and the copper foils irradiated at 10{sup 15} W/cm{sup 2}. The instrument demonstrated a resolving power of {approx}120 at 19 A with a time resolution of 31 ps. The time-resolved copper emission spectrum was consistent with a photodiode monitoring the laser temporal pulse shape and indicated that the soft x-ray emission follows the laser heating of the target. The time and spectral resolutions of this diagnostic make it useful for studies of high temperature plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrafast probes at the interfaces of solar energy conversion materials

Ultrafast carrier dynamics at interfaces plays a major role in governing solar energy conversion efficiency in solar conversion systems, especially in solar cells and photoelectrochemical devices. Here, we discuss recent advances in ultrafast spectroscopic probes to understand the dynamics at such interfaces. Transient reflectance (TR) enables monitoring of the surface carriers that are within ~10 nm of the surface or interface of interest. Crucial parameters such as surface recombination velocity and carrier diffusion can be determined. When a strong surface or interfacial field is present the reflectance spectrum will exhibit Franz–Kelydesh oscillations. Monitoring the transient formation or decay of such oscillations informs about the interfacial field and is referred to as transient photoreflectance (TPR). Such fields are helpful in designing systems in order to move carriers away from surfaces where photocorrosion can occur and towards catalytic surfaces. Finally, we discuss transient infrared attenuated total reflection (TATR) to probe the ultrafast reaction intermediates in a photo-driven chemical reaction.

14 SOLAR ENERGY↗