Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “space needle”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

NASA Robotic Neurosurgery Testbed

The detection of tissue interface (e.g., normal tissue, cancer, tumor) has been limited clinically to tactile feedback, temperature monitoring, and the use of a miniature ultrasound probe for tissue differentiation during surgical operations. In neurosurgery, the needle used in the standard stereotactic CT (Computational Tomography) or MRI (Magnetic Resonance Imaging) guided brain biopsy provides no information about the tissue being sampled. The tissue sampled depends entirely upon the accuracy with which the localization provided by the preoperative CT or MRI scan is translated to the intracranial biopsy site. In addition, no information about the tissue being traversed by the needle (e.g., a blood vessel) is provided. Hemorrhage due to the biopsy needle tearing a blood vessel within the brain is the most devastating complication of stereotactic CT/MRI guided brain biopsy. A robotic neurosurgery testbed has been developed at NASA Ames Research Center as a spin-off of technologies from space, aeronautics and medical programs. The invention entitled 'Robotic Neurosurgery Leading to Multimodality Devices for Tissue Identification' is nearing a state ready for commercialization. The devices will: 1) improve diagnostic accuracy and precision of general surgery, with near term emphasis on stereotactic brain biopsy, 2) automate tissue identification, with near term emphasis on stereotactic brain biopsy, to permit remote control of the procedure, and 3) reduce morbidity for stereotactic brain biopsy. The commercial impact from this work is the potential development of a whole new generation of smart surgical tools to increase the safety, accuracy and efficiency of surgical procedures. Other potential markets include smart surgical tools for tumor ablation in neurosurgery, general exploratory surgery, prostate cancer surgery, and breast cancer surgery.

Mah, Robert↗

NASA Robotic Neurosurgery Testbed

The detection of tissue interface (e.g., normal tissue, cancer, tumor) has been limited clinically to tactile feedback, temperature monitoring, and the use of a miniature ultrasound probe for tissue differentiation during surgical operations, In neurosurgery, the needle used in the standard stereotactic CT or MRI guided brain biopsy provides no information about the tissue being sampled. The tissue sampled depends entirely upon the accuracy with which the localization provided by the preoperative CT or MRI scan is translated to the intracranial biopsy site. In addition, no information about the tissue being traversed by the needle (e.g., a blood vessel) is provided. Hemorrhage due to the biopsy needle tearing a blood vessel within the brain is the most devastating complication of stereotactic CT/MRI guided brain biopsy. A robotic neurosurgery testbed has been developed at NASA Ames Research Center as a spin-off of technologies from space, aeronautics and medical programs. The invention entitled "Robotic Neurosurgery Leading to Multimodality Devices for Tissue Identification" is nearing a state ready for commercialization. The devices will: 1) improve diagnostic accuracy and precision of general surgery, with near term emphasis on stereotactic brain biopsy, 2) automate tissue identification, with near term emphasis on stereotactic brain biopsy, to permit remote control of the procedure, and 3) reduce morbidity for stereotactic brain biopsy. The commercial impact from this work is the potential development of a whole new generation of smart surgical tools to increase the safety, accuracy and efficiency of surgical procedures. Other potential markets include smart surgical tools for tumor ablation in neurosurgery, general exploratory surgery, prostate cancer surgery, and breast cancer surgery.

Mah, Robert↗

Low-Friction, Low-Profile, High-Moment Two-Axis Joint

The two-axis joint is a mechanical device that provides two-degrees-of-freedom motion between connected components. A compact, moment-resistant, two-axis joint is used to connect an electromechanical actuator to its driven structural members. Due to the requirements of the overall mechanism, the joint has a low profile to fit within the allowable space, low friction, and high moment-reacting capability. The mechanical arrangement of this joint can withstand high moments when loads are applied. These features allow the joint to be used in tight spaces where a high load capability is required, as well as in applications where penetrating the mounting surface is not an option or where surface mounting is required. The joint consists of one base, one clevis, one cap, two needle bearings, and a circular shim. The base of the joint is the housing (the base and the cap together), and is connected to the grounding structure via fasteners and a bolt pattern. Captive within the housing, between the base and the cap, are the rotating clevis and the needle bearings. The clevis is attached to the mechanical system (linear actuator) via a pin. This pin, and the rotational movement of the clevis with respect to the housing, provides two rotational degrees of freedom. The larger diameter flange of the clevis is sandwiched between a pair of needle bearings, one on each side of the flange. During the assembly of the two-axis joint, the circular shims are used to adjust the amount of preload that is applied to the needle bearings. The above arrangement enables the joint to handle high moments with minimal friction. To achieve the high-moment capability within a low-profile joint, the use of depth of engagement (like that of a conventional rotating shaft) to react moment is replaced with planar engagement parallel to the mounting surface. The needle bearings with the clevis flange provide the surface area to react the clevis loads/moments into the joint housing while providing minimal friction during rotation. The diameter of the flange and the bearings can be increased to react higher loads and still maintain a compact surface mounting capability. This type of joint can be used in a wide variety of mechanisms and mechanical systems. It is especially effective where precise, smooth, continuous motion is required. For example, the joint can be used at the end of a linear actuator that is required to extend and rotate simultaneously. The current design application is for use in a spacecraft docking-system capture mechanism. Other applications might include industrial robotic or assembly line apparatuses, positioning systems, or in the motion-based simulator industry that employs complex, multi-axis manipulators for various types of motions.

Lewis, James L.↗

Crystal growth and structure determination of K{sub 2}TiO{sub 3}: A five coordinate titanate

Long, needle-shaped single crystals of K{sub 2}TiO{sub 3} were grown out of a reactive high temperature hydroxide melt. The structure was determined by single crystal X-ray diffraction and found to crystallize in the orthorhombic Cmcm space group with a = 10.0283(2) A, b = 6.9346(2) A, c = 5.4534(1) A, V = 379.242(15) A{sup 3}, and Z = 4. The structure is related to the K{sub 2}SnO{sub 3} and K{sub 2}ZrO{sub 3} structures, which crystallize in the Pnma space group, and that of K{sub 2}PbO{sub 3}, which crystallizes in the Cmc2{sub 1} space group. The structure consists of chains of trans edge-sharing TiO{sub 5} rectangular pyramids with alternating apical directions. The chains are separated by KO{sub 7} polyhedra.

36 MATERIALS SCIENCE↗

Basic principles for measurement of intramuscular pressure

We review historical and methodological approaches to measurements of intramuscular pressure (IMP) in humans. These techniques provide valuable measures of muscle tone and activity as well as diagnostic criteria for evaluation of exertional compartment syndrome. Although the wick and catheter techniques provide accurate measurements of IMP at rest, their value for exercise studies and diagnosis of exertional compartment syndrome is limited because of low frequency response and hydrostatic (static and inertial) pressure artifacts. Presently, most information on diagnosis of exertional compartment syndromes during dynamic exercise is available using the Myopress catheter. However, future research and clinical diagnosis using IMP can be optimized by the use of a miniature transducer-tipped catheter such as the Millar Mikro-tip.

NASA Center ARC↗

Paravertebral Collateral Arteries in Patients with Carotid Stenosis: Is There a Safe Space for Transforaminal Cervical Nerve Root Injections?

Aim: Image-guided cervical nerve root injections can cause serious complications including spinal cord infarction. This risk may be increased in patients with carotid stenosis who develop collateral arteries. The aim of this study is to describe the prevalence, and anatomical location, of arterial collateral vessels in relation to the optimal needle tip position in cervical nerve root injections. Materials and Methods: This retrospective study included 25 patients who had > 70% stenosis on a carotid CT angiogram. For each foramen the position of collateral arteries and the most anterior point of the facet joint were recorded, as Cartesian coordinates, by two independent observers. Descriptive statistics were used to analyse and present the results. Results: 14 patients had unilateral and 11 had bilateral stenoses. A total of 85 collaterals were identified at all levels, the most common being C2/3. The median distance from collateral to optimal needle tip placement was 9.6 mm (95% CI median: 6.7–12.4, IQR: 5.6–15.6). The minimum distance was 2.9 mm. Inter-observer reliability was “substantial” (ICC 0.78, 95% CI 0.71–0.83). Conclusion: Collateral arteries were common in our cohort of patients with carotid artery stenosis and half lay within 10 mm of the optimal position for transforaminal cervical nerve root injection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Internal and near nozzle measurements of Engine Combustion Network “Spray G” gasoline direct injectors

Gasoline direct injection (GDI) sprays are complex multiphase flows. When compared to multi-hole diesel sprays, the plumes are closely spaced, and the sprays are more likely to interact. The effects of multi-jet interaction on entrainment and spray targeting can be influenced by small variations in the mass fluxes from the holes, which in turn depend on transients in the needle movement and small-scale details of the internal geometry. In this paper, we present a comprehensive overview of a multi-institutional effort to experimentally characterize the internal geometry and near-nozzle flow of the Engine Combustion Network (ECN) Spray G gasoline injector. In order to develop a complete picture of the near-nozzle flow, a standardized setup was shared between facilities. A wide range of techniques were employed, including both X-ray and visible-light diagnostics. The novel aspects of this work include both new experimental measurements, and a comparison of the results across different techniques and facilities. The breadth and depth of the data reveal phenomena which were not apparent from analysis of the individual data sets. We show that plume-to-plume variations in the mass fluxes from the holes can cause large-scale asymmetries in the entrainment field and spray structure. Both internal flow transients and small-scale geometric features can have an effect on the external flow. The sharp turning angle of the flow into the holes also causes an inward vectoring of the plumes relative to the hole drill angle, which increases with time due to entrainment of gas into a low-pressure region between the plumes. In conclusion, these factors increase the likelihood of spray collapse with longer injection durations.

33 ADVANCED PROPULSION SYSTEMS↗

DIRECT IMAGING OF AN ASYMMETRIC DEBRIS DISK IN THE HD 106906 PLANETARY SYSTEM

We present the first scattered light detections of the HD 106906 debris disk using the Gemini/Gemini Planet Imager in the infrared and Hubble Space Telescope (HST)/Advanced Camera for Surveys in the optical. HD 106906 is a 13 Myr old F5V star in the Sco–Cen association, with a previously detected planet-mass candidate HD 106906b projected 650 AU from the host star. Our observations reveal a near edge-on debris disk that has a central cleared region with radius ∼50 AU, and an outer extent >500 AU. The HST data show that the outer regions are highly asymmetric, resembling the “needle” morphology seen for the HD 15115 debris disk. The planet candidate is oriented ∼21° away from the position angle of the primary’s debris disk, strongly suggesting non-coplanarity with the system. We hypothesize that HD 106906b could be dynamically involved in the perturbation of the primary’s disk, and investigate whether or not there is evidence for a circumplanetary dust disk or cloud that is either primordial or captured from the primary. We show that both the existing optical properties and near-infrared colors of HD 106906b are weakly consistent with this possibility, motivating future work to test for the observational signatures of dust surrounding the planet.

79 ASTRONOMY AND ASTROPHYSICS↗

Complications Associated with the Percutaneous Insertion of Fiducial Markers in the Thorax

PurposeRadiosurgery requires precise lesion localization. Fiducial markers enable lesion tracking, but complications from insertion may occur. The purpose of this study was to describe complications of fiducial marker insertion into pulmonary lesions.Materials and MethodsClinical and imaging records of 28 consecutive patients with 32 lung nodules or masses who underwent insertion of a total of 59 fiducial markers before radiosurgery were retrospectively reviewed.ResultsEighteen patients (67%) developed a pneumothorax, and six patients (22%) required a chest tube. The rates of pneumothorax were 82% and 40%, respectively, when 18-gauge and 19-gauge needles were used for marker insertion (P = 0.01). Increased rate of pneumothorax was also associated with targeting smaller lesions (P = 0.03) and tumors not in contact with the pleural surface (P = 0.04). A total of 11 fiducials (19%) migrated after insertion into the pleural space (10 markers) or into the airway (1 marker). Migration was associated with shorter distances from pleura to the marker deposition site (P = 0.04) and with fiducial placement outside of the target lesion (P = 0.03).ConclusionFiducial marker placement into lung lesions is associated with a high risk of pneumothorax and a risk of fiducial migration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stiffener Jumping for Unitized Stitched Composite Preform Manufacturing

A single-sided stitching head is used to assemble unitized three-dimensional preforms using the NASA Langley Research Center (LaRC) Integrated Structural Assembly of Advanced Composites (ISAAC) robotic manufacturing system. Typically, assembly of a preform includes a “skin” that is stiffened by stiffener elements stitched to the skin. The single-sided stitching head has two needles that pass through the preform from the same side to form the stitch, typically from the smooth outer surface so the needles penetrate through the preform towards the stiffener side. The single-sided head cannot stitch across stiffening elements (e.g., stringer, frame, integral cap, etc.) because the needles would penetrate into the stiffener web, which would not allow the stitch form because the thread movement would be impeded. As a result, stitching seams cannot cross stiffening elements, and therefore are very short and must remain in the skin/flange connections within the space between the stiffening element webs. Each short segment requires a stop and cut process that takes a significant amount of time. A stiffener jumping stitching method was developed that eliminates the need to cut and restart seams when encountering a stiffener, thus providing a long, continuous seam with a significant reduction in stitching time by eliminating cutting operations and associated excess thread end trimming. This stiffener jumping process places what could be considered a very long stitch that bridges the stiffener to connect the end of one segment of the seam with the beginning of the next segment of the seam to provide a longer continuous seam. As a result, all intermediate thread cuts that would be done at the end of each individual segment of the seam are eliminated, with only a single cut at the end of the seam. The process and programming requirements for carrying out the stiffener jumping stitching approach are presented in this paper. Using the presented stiffener jumping approach to produce the long continuous seams, the stitching time for a representative commercial transport unitized stiffened wing cover panel can possibly be reduced by at least 25 percent.

stitched↗

Cu{sub 22}Bi{sub 12}S{sub 21}Cl{sub 16}-A mixed conductor with fast one-dimensional copper(I) ion transport

Melting reactions of Cu, CuCl, S, and Bi{sub 2}S{sub 3} yield black, shiny needles of Cu{sub 22(1)}Bi{sub 12}S{sub 21(1)}Cl{sub 16(1)}. The compound decomposes peritectically at 649(5) K. Oxidation state +I of the copper atoms is supported by Cu-K-XANES. The compound crystallizes in the hexagonal space group P6/m with a=2116.7(7) pm and c=395.17(5) pm. Seven anions coordinate each of the two independent bismuth cations in the shape of mono-capped trigonal prisms. These polyhedra share edges and faces to form trigonal and hexagonal tubes running along [0 0 1]. The hexagonal tubes are centered by chloride ions, which are surrounded by disordered copper cations. The majority of copper cations are distributed over numerous sites between the tubes. The Joint Probability Density Function (JPDF) reveals a continuous pathway along [0 0 1]. The high mobility of the copper cations along [0 0 1] was demonstrated by impedance spectroscopy and DC polarization measurements on single crystals. The ionic conductivity at 450 K is about {sigma}{sub ion}=0.06 S cm{sup -1}, and the activation energy for Cu{sup +} ion conduction is E{sub a}=0.44 eV. The chemical diffusion coefficient of copper is in the order of D{sub cu}{sup {delta}=}10{sup 19} cm{sup -3} at 420 K. The electronic band gap (p-type conductor) was determined as E{sub g}=0.06 eV. At room temperature the thermal conductivity of a pressed pellet is about {kappa}=0.3 W K{sup -1} m{sup -1} and the Seebeck coefficient is S=43 {mu}V K{sup -1}. -- Graphical Abstract: Copper cations easily move through the rigid tubular crystal structure of Cu{sub 22}Bi{sub 12}S{sub 21}Cl{sub 16}. Display Omitted

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-F-T-41: 3D MTP-TRUS for Prostate Implant

Purpose: Prostate brachytherapy is an effective treatment for early prostate cancer. The current prostate implant is limited to using 2D transrectal ultrassound (TRUS) or machenical motor driven 2D array either in the end or on the side. Real-time 3D images can improve the accuracy of the guidance of prostate implant. The concept of our system is to allow realtime full visualization of the entire prostate with the multiple transverse scan. Methods: The prototype of 3D Multiple-Transverse-Plane Transrectal Ultrasound probe (MTP-TRUS) has been designed by us and manufactured by Blatek inc. It has 7 convex linear arrays and each array has 96 elements. It is connected to cQuest Fire bird research system (Cephasonics inc.) which is a flexible and configurable ultrasound-development platform. The size of cQuest Firebird system is compact and supports the real-time wireless image transferring. A relay based mux board is designed for the cQuest Firebird system to be able to connect 672 elements. Results: The center frequency of probe is 6MHz±10%. The diameter of probe is 3cm and the length is 20cm. The element pitch is 0.205 mm. Array focus is 30mm and spacing 1.6cm. The beam data for each array was measured and met our expectation. The interface board of MTP-TURS is made and able to connect to cQuest Firebird system. The image display interface is still under the development. Our real-time needle tracking algorithm will be implemented too. Conclusion: Our MTP-TRUS system for prostate implant will be able to acquire real-time 3D images of prostate and do the real-time needle segmentation and tracking. The system is compact and have wireless function.

60 APPLIED LIFE SCIENCES↗

Engineering Launch Methods for Non-Spherical Hypervelocity Projectiles

The use of carbon-fiber-reinforced polymer (CFRP) in modern satellites has led to a significant amount of space debris, including fragments of CFRP and high-density metals such as steel and copper, produced during catastrophic breakup events. To address this issue, NASA's White Sands Test Facility (WSTF) has been developing the capability to launch "flake-like" and long "needle-like" projectiles. WSTF tested projectiles with different length-to-diameter ratios (L/D), impacting aluminum Whipple shields with thermal blankets on the outer surface, at velocities exceeding 6 km/s. The results of the study suggest that launching and imaging shaped projectiles at high velocities is feasible. Ongoing research is now focused on improving the techniques for launching and imaging shaped projectiles under hypervelocity conditions.

Engineering↗

Thunderstorm detection and warning system atmospheric potential monitor

An new type of electric field instrumentation was developed for lighting prediction at KSC. Currently, it is being installed at several government laboratories and is being made available to the public. It has important advantages over the previous method for measuring electric fields with motor driven field mills: (1) it has no moving parts and requires little maintenance compared to rotating machinery; (2) it is unaffected by rain, snow, sand, or insects, all of which can influence field mills; and (3) the lightweight sensor can be mounted easily on a tall mast. By mounting the instrumentation on a tall mast the instrumentation is placed above much of the blanket of point discharge ions that are emitted from objects on the ground during thunderstorms. This space charge limits the ability of any ground based electric field sensor to accurately measure cloud electric fields which produce lightning. The elevated mounting was demonstrated to significantly improve monitoring of thunderstorm electric fields. This instrumentation measures the atmospheric potential relative to earth at a corona needle sensor on top of a mast which normally is mounted on a tower or roof. The needle is kept in corona at all times by a low power high voltage power supply. This produces a small cloud of ions around the needle allowing a current to flow. Measurement of the current provides the atmospheric potential. The potential divided by the height of the needle above the ground is proportional to the average electric field between the needle and earth. The potential on top of a tall pole or above a rooftop is more representative of the intensity of cloud electrification than electric field measurements made at ground level. Photographs that depict the computer terminal, video display of a two sensor system, and the individual components installed on a tower are presented.

Source record↗

Dosimetric equivalence of nonstandard HDR brachytherapy catheter patterns

Purpose: To determine whether alternative high dose rate prostate brachytherapy catheter patterns can result in similar or improved dose distributions while providing better access and reducing trauma. Materials and Methods: Standard prostate cancer high dose rate brachytherapy uses a regular grid of parallel needle positions to guide the catheter insertion. This geometry does not easily allow the physician to avoid piercing the critical structures near the penile bulb nor does it provide position flexibility in the case of pubic arch interference. This study used CT datasets with 3 mm slice spacing from ten previously treated patients and digitized new catheters following three hypothetical catheter patterns: conical, bi-conical, and fireworks. The conical patterns were used to accommodate a robotic delivery using a single entry point. The bi-conical and fireworks patterns were specifically designed to avoid the critical structures near the penile bulb. For each catheter distribution, a plan was optimized with the inverse planning algorithm, IPSA, and compared with the plan used for treatment. Irrelevant of catheter geometry, a plan must fulfill the RTOG-0321 dose criteria for target dose coverage (V{sub 100}{sup Prostate}>90%) and organ-at-risk dose sparing (V{sub 75}{sup Bladder}<1 cc, V{sub 75}{sup Rectum}<1 cc, V{sub 125}{sup Urethra}<<1 cc). Results: The three nonstandard catheter patterns used 16 nonparallel, straight divergent catheters, with entry points in the perineum. Thirty plans from ten patients with prostate sizes ranging from 26 to 89 cc were optimized. All nonstandard patterns fulfilled the RTOG criteria when the clinical plan did. In some cases, the dose distribution was improved by better sparing the organs-at-risk. Conclusion: Alternative catheter patterns can provide the physician with additional ways to treat patients previously considered unsuited for brachytherapy treatment (pubic arch interference) and facilitate robotic guidance of catheter insertion. In addition, alternative catheter patterns may decrease toxicity by avoidance of the critical structures near the penile bulb while still fulfilling the RTOG criteria.

61 RADIATION PROTECTION AND DOSIMETRY↗

Tenderness Tester

Space telemetry has been transferred to food processing in the Armour;Tenderorneter, an instrument that predicts the tenderness of meat. The space component of the instrument is a sensitive, highly reliable strain gage originally produced for NASA's Surveyor lunar lander and other space programs by BLH Electronics, Waltham, Mass. Several years ago Armour & Co. began to develop a method of testing a hanging carcass to predict how tender the meat would be after cooking; no such method then existed. After considerable experimentation, Armour came up with a manifold-mounted group of-needle-like probes, which when stuck into a carcass, could measure the degree to which the meat resisted penetration. This provided a basis for predicting tenderness, but the development required one more . step; a device that could translate meat resistance into an electrical readout. Armour found it in the BLH strain gage. The resulting Tenderometer, now a standard and important part of Armour's meat processing operation, includes a large, 10-pronged fork which is plunged into a carcass and a cable-connected, handheld electronic device that translates the sensings of the prongs into a tenderness reading on a dial. The instrument is used by Armour to select and guarantee a premium line of beef known as TesTender, whose annual sales run into tens of millions of pounds.

Source record↗

Weighted simultaneous algebraic reconstruction technique for tomosynthesis imaging of objects with high-attenuation features

Purpose: This paper introduces a nonlinear weighting scheme into the backprojection operation within the simultaneous algebraic reconstruction technique (SART). It is designed for tomosynthesis imaging of objects with high-attenuation features in order to reduce limited angle artifacts. Methods: The algorithm estimates which projections potentially produce artifacts in a voxel. The contribution of those projections into the updating term is reduced. In order to identify those projections automatically, a four-dimensional backprojected space representation is used. Weighting coefficients are calculated based on a dissimilarity measure, evaluated in this space. For each combination of an angular view direction and a voxel position an individual weighting coefficient for the updating term is calculated. Results: The feasibility of the proposed approach is shown based on reconstructions of the following real three-dimensional tomosynthesis datasets: a mammography quality phantom, an apple with metal needles, a dried finger bone in water, and a human hand. Datasets have been acquired with a Siemens Mammomat Inspiration tomosynthesis device and reconstructed using SART with and without suggested weighting. Out-of-focus artifacts are described using line profiles and measured using standard deviation (STD) in the plane and below the plane which contains artifact-causing features. Artifacts distribution in axial direction is measured using an artifact spread function (ASF). The volumes reconstructed with the weighting scheme demonstrate the reduction of out-of-focus artifacts, lower STD (meaning reduction of artifacts), and narrower ASF compared to nonweighted SART reconstruction. It is achieved successfully for different kinds of structures: point-like structures such as phantom features, long structures such as metal needles, and fine structures such as trabecular bone structures. Conclusions: Results indicate the feasibility of the proposed algorithm to reduce typical tomosynthesis artifacts produced by high-attenuation features. The proposed algorithm assigns weighting coefficients automatically and no segmentation or tissue-classification steps are required. The algorithm can be included into various iterative reconstruction algorithms with an additive updating strategy. It can also be extended to computed tomography case with the complete set of angular data.

60 APPLIED LIFE SCIENCES↗

Comparative Transcriptomics Among Four White Pine Species

Conifers are the dominant plant species throughout the high latitude boreal forests as well as some lower latitude temperate forests of North America, Europe, and Asia. As such, they play an integral economic and ecological role across much of the world. This study focused on the characterization of needle transcriptomes from four ecologically important and understudied North American white pines within the Pinus subgenus Strobus. The populations of many Strobus species are challenged by native and introduced pathogens, native insects, and abiotic factors. RNA from the needles of western white pine (Pinus monticola), limber pine (Pinus flexilis), whitebark pine (Pinus albicaulis), and sugar pine (Pinus lambertiana) was sampled, Illumina short read sequenced, and de novo assembled. The assembled transcripts and their subsequent structural and functional annotations were processed through custom pipelines to contend with the challenges of non-model organism transcriptome validation. Orthologous gene family analysis of over 58,000 translated transcripts, implemented through Tribe-MCL, estimated the shared and unique gene space among the four species. This revealed 2025 conserved gene families, of which 408 were aligned to estimate levels of divergence and reveal patterns of selection. Specific candidate genes previously associated with drought tolerance and white pine blister rust resistance in conifers were investigated.

59 BASIC BIOLOGICAL SCIENCES↗