A Large Detector Laboratory for the Development and Testing of Radiation Detection Systems

Thousands of radiation detection systems have been deployed over the last decade to domestic and international locations, primarily at ports of entry or departure. An essential ingredient in supporting sensor deployment is the capability to develop and test emerging systems and replicate the behavior of deployed systems. Pacific Northwest National Laboratory recently designed and constructed a laboratory for developing and testing these large-scale radiation detection systems. The Large Detector Laboratory is capable of housing up to 30 fully integrated radiation portal monitoring systems and allows for complex testing scenarios that include background suppression, equipment shielding, and source cross talk between systems. The laboratory design also allows implementation of applications ranging from pedestrian screening to baggage or package inspection to vehicle and cargo inspection to standoff detection. This manuscript describes the unique attributes of this laboratory that includes reproducing operational conditions faced by integrated systems, realistic source configurations and measurements across multiple systems.

laboratory↗

Environment scattering in GADRAS.

Radiation transport calculations were performed to compute the angular tallies for scattered gamma-rays as a function of distance, height, and environment. Green s Functions were then used to encapsulate the results a reusable transformation function. The calculations represent the transport of photons throughout scattering surfaces that surround sources and detectors, such as the ground and walls. Utilization of these calculations in GADRAS (Gamma Detector Response and Analysis Software) enables accurate computation of environmental scattering for a variety of environments and source configurations. This capability, which agrees well with numerous experimental benchmark measurements, is now deployed with GADRAS Version 18.2 as the basis for the computation of scattered radiation.

Thoreson, Gregory G.↗

Active Well Counting Using New PSD Plastic Detectors

This report presents results and analysis from a series of proof-of-concept measurements to assess the suitability of segmented detectors constructed from Eljen EJ-299-34 PSD-plastic scintillator with pulse-shape discrimination capability for the purposes of quantifying uranium via active neutron coincidence counting. Present quantification of bulk uranium materials for international safeguards and domestic materials control and accounting relies on active neutron coincidence counting systems, such as the Active Well Coincidence Counter (AWCC) and the Uranium Neutron Coincidence Collar (UNCL), that use moderated He-3 proportional counters along with necessarily low-intensity 241Am(Li) neutron sources. Scintillation-based fast-neutron detectors are a potentially superior technology to the existing AWCC and UNCL designs due to their spectroscopic capability and their inherently short neutron coincidence times that largely eliminate random coincidences and enable interrogation by stronger sources. One of the past impediments to the investigation and adoption of scintillation counters for the purpose of quantifying bulk uranium was the commercial availability of scintillators having the necessary neutron-gamma pulse-shape discrimination properties only as flammable liquids. Recently, Eljen EJ-299-34 PSD-plastic scintillator became commercially available. The present work is the first assessment of an array of PSD-plastic detectors for the purposes of quantifying bulk uranium. The detector panel used in the present work was originally built as the focal plane for a fast-neutron imager, but it was repurposed for the present investigation by construction of a stand to support the inner well of an AWCC immediately in front of the detector panel. The detector panel and data acquisition of this system are particularly well suited for performing active-well fast-neutron counting of LEU and HEU samples because the active detector volume is solid, the 241Am(Li) interrogating neutrons are largely below the detector threshold, and the segmented construction of the detector modules allow for separation of true neutron-neutron coincidences from inter-detector scattering using the kinematics of neutron scattering. The results from a series of measurements of a suite of uranium standards are presented, and compared to measurements of the same standards and source configurations using the AWCC. Using these results, the performance of the segmented detectors reconfigured as a well counter is predicted and outperforms the AWCC.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Complete Reporting of MCNP6 Validation Results for Electron Energy Deposition in Single-Layer Extended Media for Source Energies <= 1-MeV

In this paper, we expand on previous validation work by Dixon and Hughes. That is, we present a more complete suite of validation results with respect to to the well-known Lockwood energy deposition experiment. Lockwood et al. measured energy deposition in materials including beryllium, carbon, aluminum, iron, copper, molybdenum, tantalum, and uranium, for both single- and multi-layer 1-D geometries. Source configurations included mono-energetic, mono-directional electron beams with energies of 0.05-MeV, 0.1-MeV, 0.3- MeV, 0.5-MeV, and 1-MeV, in both normal and off-normal angles of incidence. These experiments are particularly valuable for validating electron transport codes, because they are closely represented by simulating pencil beams incident on 1-D semi-infinite slabs with and without material interfaces. Herein, we include total energy deposition and energy deposition profiles for the single-layer experiments reported by Lockwood et al. (a more complete multi-layer validation will follow in another report).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The ERL Facility PERLE at Orsay

The realisation of the LHeC and the FCC-eh at CERN require the development of the energy recovering technique in multipass mode and for large currents O(10) mA in the SRF cavities. For this purpose, a technology development facility, PERLE, is under design to be built at IJCLab Orsay, which has the key LHeC ERL parameters, in terms of configuration, source, current, frequency and technical solutions, cryomodule, stacked magnets. In this talk we review the design and comment on the status of PERLE.

Bogacz, Alex↗

Low Frequency Cable Dual Shield Penetration Using Complete Transfer Immittance Model

This report discusses low frequency coupling and subsequent penetration of a dual shield cable using a transfer immittance model with reciprocal sources. Configurations include: 1) where the cable is above a ground plane and shorted at both ends, 2) a monopole arrangement where it is shorted at one end and open at the other end, and 3) a monopole arrangement where the open end is loaded by a disc. The open circuit voltage within the cable is estimated for each case.

42 ENGINEERING↗

Characterization of the Neutron Fields in the Lawrence Livermore National Laboratory (LLNL) Radiation Calibration Laboratory Low Scatter Calibration Facility

In June 2007, the Department of Energy (DOE) revised its rule on Occupational Radiation Protection, Part 10 CFR 835. A significant aspect of the revision was the adoption of the recommendations outlined in International Commission on Radiological Protection (ICRP) Report 60 (ICRP-60), including new radiation weighting factors for neutrons, updated internal dosimetric models, and dose terms consistent with the newer ICRP recommendations. ICRP-60 uses the quantities defined by the International Commission on Radiation Units and Measurements (ICRU) for personnel and area monitoring including the ambient dose equivalent H*(d). A Joint Task Group of ICRU and ICRP has developed various fluence-to-dose conversion coefficients which are published in ICRP-74 for both protection and operational quantities. In February 2008, Lawrence Livermore National Laboratory (LLNL) replaced its old pneumatic transport neutron irradiation system in the Radiation Calibration Laboratory (RCL) Low Scatter Calibration Facility (B255, Room 183A) with a Hopewell Designs irradiator model N40. The exposure tube for the Hopewell system is located close to, but not in exactly the same position as the exposure tube for the pneumatic system. Additionally, the sources for the Hopewell system are stored in Room 183A where, prior to the change, they were stored in a separate room (Room 183C). The new source configuration and revision of the 10 CFR 835 radiation weighting factors necessitate a re-evaluation of the neutron dose rates in B255 Room 183A. This report deals only with the changes in the operational quantities ambient dose equivalent and ambient dose rate equivalent for neutrons as a result of the implementation of the revised 10 CFR 835. In the report, the terms 'neutron dose' and 'neutron dose rate' will be used for convenience for ambient neutron dose equivalent and ambient neutron dose rate equivalent unless otherwise stated.

61 RADIATION PROTECTION AND DOSIMETRY↗

Methods and systems for producing fluid from an in situ conversion process

A system that includes a plurality of heat sources configured to heat a portion of a formation is described. At least one production well is in the formation. A bottom portion of the production well is a sump in an underburden of the formation below the heated portion of the formation. Fluids from the heated portion of the formation are allowed to flow into the sump. A pump system has an inlet in the sump. A production conduit is coupled to the pump system. The production conduit is configured to transport fluids in the sump out of the formation.

42 ENGINEERING↗

Coupled Deterministic-Monte Carlo Transport for Radiation Portal Modeling

Radiation portal monitors are being deployed, both domestically and internationally, to detect illicit movement of radiological materials concealed in cargo. Evaluation of the current and next generations of these radiation portal monitor (RPM) technologies is an ongoing process. 'Injection studies' that superimpose, computationally, the signature from threat materials onto empirical vehicle profiles collected at ports of entry, are often a component of the RPM evaluation process. However, measurement of realistic threat devices can be both expensive and time-consuming. Radiation transport methods that can predict the response of radiation detection sensors with high fidelity, and do so rapidly enough to allow the modeling of many different threat-source configurations, are a cornerstone of reliable evaluation results. Monte Carlo methods have been the primary tool of the detection community for these kinds of calculations, in no small part because they are particularly effective for calculating pulse-height spectra in gamma-ray spectrometers. However, computational times for problems with a high degree of scattering and absorption can be extremely long. Deterministic codes that discretize the transport in space, angle, and energy offer potential advantages in computational efficiency for these same kinds of problems, but the pulse-height calculations needed to predict gamma-ray spectrometer response are not readily accessible. These complementary strengths for radiation detection scenarios suggest that coupling Monte Carlo and deterministic methods could be beneficial in terms of computational efficiency. Pacific Northwest National Laboratory and its collaborators are developing a RAdiation Detection Scenario Analysis Toolbox (RADSAT) founded on this coupling approach. The deterministic core of RADSAT is Attila, a three-dimensional, tetrahedral-mesh code originally developed by Los Alamos National Laboratory, and since expanded and refined by Transpire, Inc. [1]. MCNP5 is used to calculate sensor pulse-height tallies. RADSAT methods, including adaptive, problem-specific energy-group creation, ray-effect mitigation strategies and the porting of deterministic angular flux to MCNP for individual particle creation are described in [2][3][4]. This paper discusses the application of RADSAT to the modeling of gamma-ray spectrometers in RPMs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combined distance-of-flight and time-of-flight mass spectrometer

A combined distance-of-flight mass spectrometry (DOFMS) and time-of-flight mass spectrometry (TOFMS) instrument includes an ion source configured to produce ions having varying mass-to-charge ratios, a first detector configured to determine when each of the ions travels a predetermined distance, a second detector configured to determine how far each of the ions travels in a predetermined time, and a detector extraction region operable to direct portions of the ions either to the first detector or to the second detector.

47 OTHER INSTRUMENTATION↗

High-speed volume measurement system

Disclosed is a volume sensor having a first axis, a second axis, and a third axis, each axis including a laser source configured to emit a beam; a parallel beam generating assembly configured to receive the beam and split the beam into a first parallel beam and a second parallel beam, a beam-collimating assembly configured to receive the first parallel beam and the second parallel beam and output a first beam sheet and a second beam sheet, the first beam sheet and the second beam sheet being configured to traverse the object aperture; a first collecting lens and a second collecting lens; and a first photodetector and a second photodetector, the first photodetector and the second photodetector configured to output an electrical signal proportional to the object; wherein the first axis, the second axis, and the third axis are arranged at an angular offset with respect to each other.

42 ENGINEERING↗

Methods and systems for calibration of particle detectors

Techniques for calibration of particle detectors are disclosed. In one aspect, a system for calibrating a particle detector includes a source configured to emit particles including a first and a second type of particles; a first and a second shielding unit configured to be removably positioned in a travel path of the particles and configured to block at least a portion of the first type of particles and to allow the second type of particles to traverse substantially unimpeded there through; one or more particle detectors positioned in the travel path of the particles to receive particles after traversing through the first or the second shielding unit and produce electronic pulses in response to the detection of the particles; and a processor coupled to the one or more particle detectors to generate training date and a classifier that allows classification of the first and the second types of particles.

47 OTHER INSTRUMENTATION↗

Controlled microwave assisted synthesis of functionalized silica nanoparticles

A method of synthesizing silica nanoparticles. The method includes hydrolyzing a silica precursor to form a plurality of monomers, each monomer of the plurality comprising a microwave reactive silicon species. The plurality of monomers is irradiated by an energy source configured to generate microwave frequency energy. Irradiation cases the plurality of monomers polymerize into a silica nanoparticle.

36 MATERIALS SCIENCE↗

Pedestrian Mapping with Spectral Backpacks for GPS-Denied Areas, RSLA-010-16, Year 1 of 1

Presentation describes project to investigate methods to modernize radiological/nuclear search operations in GPS-denied environments. Having a reliable way to track a searcher’s position relative to the GPS-denied frame of reference (building, vessel, tunnel) is critical for characterizing the radiation fields. It would also enable more effective, higher-sensitivity searches when weak or heavily shielded source configurations are involved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High efficiency environmental sampling with rapidly cured peelable coatings

A rapidly curable liquid gel for collecting an analyte from a sampling surface includes a polymer precursor mixture including a monomer and/or an oligomer; and an additive to enhance extraction of the analyte from the sampling surface. A kit for collecting an analyte from a sampling surface may include the rapidly curable liquid gel and a portable device for rapidly curing the gel. The rapidly curable liquid gel is cured to thereby form a peelable sampling film, and the sampling film is removed from the sampling surface, thereby collecting the analyte. In one embodiment, the rapidly curable liquid gel is UV-curable, the polymer precursor mixture further includes a photoinitiator compound, and the portable device includes a UV light source configured to emit UV light of a wavelength range absorbed by the photoinitiator compound.

Henzl, Vladimir↗

Controlled microwave assisted synthesis of functionalized silica nanoparticles

A functionalized fiber. The functionalized fiber includes a fiber strand and silica nanoparticles at least partially encapsulating the fiber strand. The silica nanoparticles are synthesized by hydrolyzing a tetramethyl orthosilicate in hydrochloric acid to form silicic acid monomers. The silicic acid monomers are diluted in acetone and irradiated for a time that is less than 90 seconds with an energy source configured to generate microwave frequency energy to polymerize the silicic acid monomers into the silica nanoparticles.

Owens, John G.↗

Turbulent mixing by microscopic self-assembled spinners

A system for mixing particles that includes a liquid comprising inert particles and defining a liquid and air interface; magnetic microparticles suspended at the liquid and air interface; and a magnetic source configured to apply a uniaxial alternating magnetic field parallel to the liquid and air interface, wherein the uniaxial alternating magnetic field promotes a turbulent motion of the magnetic microparticles, which in turn promotes a diffusive motion of the inert particles.

Snezhko, Oleksiy↗