Variations of the cosmic ray general component in Antarctica

A cosmic ray variations, zonal cosmic ray modulation, was found in the lower atmosphere from the sonde measurement results. The variations give rise to anomalies in the latitude distributions of the cosmic ray charged component and the anomalous north-south asymmetry. To find the nature of the variations, the cosmic ray general component was measured with the same detectors as in the sonde measurements gas discharge counters and the counter telescopes with 7-mm Al filters detecting the electrons of energy above 200 keV and 5 MeV. The measurement data obtained in Antarctica in the years 1978 to 1983 are presented and discussed.

Charakhchyan, T. N.↗

Ozone measurements using balloon-borne ozonesondes

Vertical profiles of atmospheric ozone have been measured for a number of years by WFF personnel using small balloon borne ozonesondes. These sondes are interfaced with meteorological radiosondes so that both ozone data and meterological data (pressure, temperature, humidity, wind speed and direction) are obtained from ground level up to 30 to 35 km. Efforts at Wallops have been focused in three areas. The first involves biweekly launches from two sites (Wallops and Natal, Brazil), timed to coincide with overpasses of satellite borne ozone sensors such as the Solar Backscattered Ultraviolet. The resulting data are reported to the World Ozone Data Center and are used for satellite correlative support, as well as, for studies of both tropospheric and stratospheric ozone. The second activity consists of field campaigns in remote locations in support of special projects. The third is a continuing activity to quantitatively evaluate and improve the sonde's performance under stratospheric conditions.

Torres, A. L.↗

Volcanic-aerosol-induced changes in stratospheric ozone following the eruption of Mount Pinatubo

Measurements of lower stratospheric ozone in the Tropics using electrochemical concentrations cell (ECC) sondes and the airborne UV Differential Absorption Lidar (DIAL) system after the eruption of Mt. Pinatubo are compared with the Stratospheric Aerosol and Gas Experiment 2 (SAGE 2) and ECC sonde measurements from below the eruption to determine what changes have occurred as a result. Aerosol data from the Advanced Very High Resolution Radiometer (AVHRR) and the visible and IR wavelengths of the lidar system are used to examine the relationship between aerosols and ozone changes. Ozone decreases of 30 percent at altitudes between 19 and 26 km, partial column (16-28 km) decreases of about 27 D.U., and slight increases (5.4 D.U.) between 28 and 31 km are found in comparison with SAGE 2 climatological values.

Grant, W. B.↗

The discrepancy between stratospheric ozone profiles from balloon soundings and from other techniques: A possible explanation

Regular balloon ozone soundings with electrochemical sondes have been performed at Uccle since 1969. More than 450 ozone soundings between 1985 and 1989 were used to calculate the altitudes Zs from the VIZ radiosonde data and the altitudes Zr deduced from the tracking of the balloon train with a primary wind-finding radar. The values of Zs at fixed times appeared to be systematically too low as compared to Zr. The differences Zr-Zs increase with altitude; at 30 km the annual mean values of Zr-Zs (plus or minus standard deviation) vary between 590 plus or minus 910 m and 1410 plus or minus 1160 m, according to the pressure calibration of different manufacturing series of radiosondes. From these results it is found that around the 30 km level the ozone concentrations calculated from soundings with VIZ sondes are too low by 7.5 to 14 percent, depending upon the manufacturing series of radiosondes. At least part of the discrepancy which has often been found between ozone profiles from balloon soundings and from other techniques such as rocket observations or Umkehr measurements may be explained by this effect. An altitude correction would have important consequences as to the climatology of ozone in the middle stratosphere as adopted at the moment. About half of the day-to-day variability of ozone observed from soundings with VIZ radiosondes above the 30 km level, is induced by the variability of Zr-Zs. The agreement between altitudes calculated from radar data and Vaisala radiosondes is much better; from 34 comparative soundings a mean difference (plus or minus standard deviation) of about -300 plus/minus 180 m was found at 30 km.

Demuer, Dirk↗

Aerosol-associated changes in tropical stratospheric ozone following the eruption of Mount Pinatubo

The large amount of sulfuric acid aerosol formed in the stratosphere by conversion of sulfur dioxide emitted by the eruption of Mount Pinatubo (15.14 deg N, 120.35 deg E) in the Philippines around June 15, 1991, has had a pronounced effect on lower stratospheric ozone in the tropics. Measurements of stratospheric ozone in the tropics using electrochemical concentration cell (ECC) sondes before and after the eruption and the airborne UV differential absorption lidar (DIAL) system after the eruption are compared with Stratospheric Aerosol and Gas Experiment II (SAGE II) measurements from several years before the eruption and ECC sonde measurements from the year prior to the eruption to determine the resulting changes. Ozone decreases of up to 33 % compared with SAGE II climatological values were found to be directly correlated with altitude regions of enhanced aerosol loading in the 16- to 28-km range. A maximum partial-column decrease of 29 +/- Dobson units (DU) was found over the 16- to 28-km range in September 1991 along with small increases (to 5.9 +/- 2 DU) from 28 to 31.5 km. A large decrease of ozone was also found at 4 deg to 8 deg S from May to August 1992, with a maximum decrease of 33 +/- 7 DU found above Brazzaville in July. Aerosol data form the visible channel of the advanced very high resolution radiometer (AVHRR) and the visible wavelength of the UV DIAL system were used to examine the relationship between aerosol (surface area) densities and ozone changes. The tropical stratospheric ozone changes we observed in 1991 and 1992 are likely be explained by a combination of dynamical (vertical transport) perturbations, radiative perturbations on ozone photochemistry, and heterogeneous chemistry.

Grant, William B.↗

A New Method of Deriving Time-Averaged Tropospheric Column Ozone over the Tropics Using Total Ozone Mapping Spectrometer (TOMS) Radiances: Intercomparison and Analysis Using TRACE A Data

Error analysis of archived total 03 from total ozone mapping spectrometer (TOMS) (version 6) presented. Daily total 03 maps for the tropics, from the period October 6-21, 1992, are derived from TOMS radiances following correction for these errors. These daily maps, averaged together, show a wavelike feature, which is observed in all latitude bands, underlying sharp peaks which occur at different longitudes depending on the latitude. The wave pattern is used to derive both time-averaged stratospheric and tropospheric 03 fields. The nature of the wave pattern (stratospheric or tropospheric) cannot be determined with certainty due to missing data (no Pacific sondes, no lower stratospheric Stratospheric Aerosol and Gas Experiment (SAGE) ozone for 18 months after the Mt. Pinatubo eruption) and significant uncertainties in the corroborative satellite record in the lower stratosphere (solar backscattered ultraviolet (SBUV), microwave limb sounder (MLS)). However, the time- averaged tropospheric ozone field, based on the assumption that the wave feature is stratospheric, agrees within 10% with ultraviolet differential absorption laser Transport and Atmospheric Chemistry near the Equator-Atlantic) (TRACE A) 03 measurements from the DC-8 and with ozonesonde measurements over Brazzaville, Congo, Ascension Island, and Natal, Brazil, for the period October 6-21, 1992. The derived background (nonpolluted) Indian Ocean tropospheric ozone amount, 26 Dobson units (DU), agrees with the cleanest African ozonesonde profiles for September-October 1992. The assumption of a totally tropospheric wave (flat stratosphere) gives 38 DU above the western Indian Ocean and 15-40% disagreements with the sondes. Tropospheric column 03 is high from South America to Africa, owing to interaction of dynamics with biomass burning emissions. Comparison with fire distributions from advanced very high resolution radiometer (AVHHR) during October 1992 suggests that tropospheric 03 produced from biomass burning in South America and Africa dominates the 03 budget in the tropical southern hemisphere during the study period.

Kim, J. H.↗

How Dry is the Tropical Free Troposphere? Implications for Global Warming Theory

The humidity of the free troposphere is being increasingly scrutinized in climate research due to its central role in global warming theory through positive water vapor feedback. This feedback is the primary source of global warming in general circulation models (GCMs). Because the loss of infrared energy to space increases nonlinearly with decreases in relative humidity, the vast dry zones in the Tropics are of particular interest. These dry zones are nearly devoid of radiosonde stations, and most of those stations have, until recently, ignored the low humidity information from the sondes. This results in substantial uncertainty in GCM tuning and validation based on sonde data. While satellite infrared radiometers are now beginning to reveal some information about the aridity of the tropical free troposphere, the authors show that the latest microwave humidity sounder data suggests even drier conditions than have been previously reported. This underscores the importance of understanding how these low humidity levels are controlled in order to tune and validate GCMs, and to predict the magnitude of water vapor feedback and thus the magnitude of global warming.

Spencer, Roy W.↗

Results of the NY-Alesund ozone measurements intercomparison NAOMI

Worldwide, about ten Differential Absorption Lidars are used for long-term monitoring of stratospheric ozone. These systems are an important component of the Network for the Detection of Stratospheric Change. Although DIALs are self-calibrating in principle, regular intercomparisons with other ozone-lidars, microwave radiometers or ozone-sondes are highly desirable to ensure high data quality at a well known level. The Network for the Detection of Stratospheric Change (NDSC) validation policy suggests that such intercomparisons be "blind", meaning all participants submit their data to an impartial referee, without seeing results from the other participants. Here we report on the "blind" intercomparison taking place from January 20th to February 10th 1998 at Ny-Alesund, Spitsbergen (78.92 deg N, 11.95 deg E). Participating groups were from the Alfred Wegener Institute, Potsdam, operating the NDSC DIAL system at Ny-Alesund, from the University of Bremen operating the NDSC microwave radiometer for ozone profiling at Ny-Alesund, and the NASA Goddard Space Flight Center group with the "NDSC travelling standard" STROZ-LITE. The first author acted as the impartial referee. Also used for the intercomparison were data from ECC-6A/Vaisala RS80 ozone sondes routinely launched at Ny-Alesund by the AWI group. A 1% KI solution (3 ml) and the 1986 ECC pump correction (1.092 at 5 hPa) are used. The ECC-data were available to all participants during the campaign and thus were not "blind". Table 1 summarizes the expected performance of the instruments participating in the ozone intercomparison reported in this paper.

Steinbrecht, W.↗

Tropical Tropospheric Ozone (TTO) Maps from Nimbus 7 and Earth-Probe TOMS by the Modified-Residual Method: Validation, Evaluation and Trends based on Atlantic Regional Time Series - 1

The well-known wave-one pattern seen in tropical total ozone [Shiotani, 1992; Ziemke et al., 1996, 1998] has been used to develop a modified-residual (MR) method for retrieving time-averaged stratospheric ozone and tropospheric ozone column amount from TOMS (Total Ozone Mapping Spectrometer) over the 14 complete calendar years of Nimbus 7 observations (1979-1992) and from TOMS on the Earth-Probe (1996-present) and ADEOS platforms (1996- 1997). Nine- to sixteen-day averaged tropical tropospheric ozone (TTO) maps, validated with ozonesondes, show a seasonality expected from dynamical and chemical influences. The maps may be viewed on a homepage: http://metosrv2.umd.edu/~tropo. Stratospheric column ozone, which is also derived by the modified-residual method, compares well with sondes (to within 6-7 DU) and with stratospheric ozone column derived from other satellites (within 8-10 DU). Validation of the TTO time-series is presently limited to ozonesonde comparisons with Atlantic stations and sites on the adjacent continents (Ascension Island, Natal, Brazil; Brazzaville); for the sounding periods, TTO at all locations agrees with the sonde record to +/-7 DU. TTO time-series and the magnitude of the wave-one pattern show ENSO signals in the strongest El Nifio periods from 1979-1998. From 12degN and 12degS, zonally averaged tropospheric ozone shows no significant trend from 1980-1990. Trends are also not significant during this period in localized regions, e.g. from just west of South America across to southern Africa. This is consistent with the ozonesonde record at Natal, Brazil (the only tropical ozone data publicly available for the 1980's), which shows a not statistically significant increase. The lack of trend in tropospheric ozone agrees with a statistical analysis based on another method for deriving TTO from TOMS, the so-called Convective-Cloud-Differential approach of Ziemke et al. [1998].

Thompson, Anne M.↗

Results from the 1995 Stratospheric Ozone Profile Intercomparison at Mauna Loa (MLO3)

In August 1995 multiple instruments that measure the stratospheric ozone vertical distribution were intercompared at the Mauna Loa Observatory, Hawaii, under the auspices of the Network for the Detection of Stratospheric Change. The instruments included two UV lidar systems, one from JPL and the other from Goddard Space Flight Center, ECC balloon-sondes, a ground-based microwave instrument, Umkehr measurements, and a new ground-based FTIR instrument. The MLS instrument on the UARS satellite provided correlative profiles of ozone, and there was one close overpass of the SAGE II instrument. The results show that much better consistency among instruments is being achieved than even a few years ago, usually to within the instrument uncertainties. The different measurement techniques in this comparison agree to within +/-10% at almost all altitudes, and in the 20 km to 45 km region most agreed within +/-5%. The results show that the current generation of lidars are capable of accurate measurement of the ozone profile to a maximum altitude of 50 km. SAGE agreed well with both lidar and balloon-sonde down to at least 17 km. The ground-based microwave measurement agreed with other measurements from 22 km to above 50 km. One minor source of disagreement continues to be the pressure-altitude conversion needed to compare a measurement of ozone density versus altitude with a measurement of ozone mixing ratio versus pressure.

McPeters, R. D.↗

Processes Affecting Tropospheric Ozone Inferred from Ozonesonde and Other Tracer Data from the R/V R H Brown Atlantic Cruise (37N-34S) in January-February 1999

During the Aerosols-99 trans-Atlantic cruise from Norfolk, VA, to Cape Town, South Africa, 22 ozonesondes were launched from the NOAA R/V R H Brown between 17 Jan and 6 Feb 1999, with all sondes but one reaching 30 km. A composite of ozone profiles along the transect shows high free tropospheric ozone (up to 100 ppbv at 9 km) between 5N and 20S, a coherent feature straddling either side of the ITCZ. Latitudinal variations of tropospheric ozone are interpreted using correlative measurements of surface ozone, CO, water vapor, and aerosol optical thickness (column absorbance) measured from the ship. Elevated ozone in the lower troposphere results from photochemical reactions of precursors emitted by biomass burning north of the ITCZ. However, the greatest ozone mixing ratios are in the mid-troposphere south of the ITCZ, which gives evidence of interhemispheric transport. Column-integrated tropospheric ozone, 35 DU from 0-16 km, agrees with that derived from the TOMS satellite by the modified-residual method [Thompson and Hudson, 1999]. NCEP wind fields, ship-launched radiosondes and back trajectories are consistent with a picture of recirculating air parcels centered in the tropical Atlantic region which is identified with the maximum wave-one amplitude in total ozone seen in sondes and by satellite.

Thompson, Anne M.↗

Crista Ozone Measurements/Validation

Seven days of global high resolution middle atmosphere ozone profiles have been measured by the CRyogenic Infrared Spectrometers and Telescopes for the Atmosphere (CRISTA) in November 1994. Measurements cover the altitude range from 10 to 80 km and latitudes from 59 deg S to 64 deg N. An example of a global ozone map is presented and demonstrates the ability of the instrument to detect medium and even small scale structures. Comparisons with ECC- and Brewer Mast balloon-sonde underflights are discussed. Reasonable agreement between CRISTA and balloon-sondes is found especially in the altitude interval between about 19 km and 27 km.

Bittner, M.↗

Validation of Temperature Measurements from the Airborne Raman Ozone Temperature and Aerosol Lidar During SOLVE

The Airborne Raman Ozone, Temperature and Aerosol Lidar (AROTEL) participated in the recent Sage III Ozone Loss and Validation Experiment (SOLVE) by providing profiles of aerosols, polar stratospheric clouds (PSCs), ozone and temperature with high vertical and horizontal resolution. Temperatures were derived from just above the aircraft to approximately 60 kilometers geometric altitude with a reported vertical resolution of between 0.5 and 1.5 km. The horizontal footprint varied from 4 to 70 km. This paper explores the measurement uncertainties associated with the temperature retrievals and makes comparisons with independent, coincident, measurements of temperature. Measurement uncertainties range from 0.1 K to approximately 4 K depending on altitude and integration time. Comparisons between AROTEL and balloon sonde temperatures retrieved under clear sky conditions using both Rayleigh and Raman scattered data showed AROTEL approximately 1 K colder than sonde values. Comparisons between AROTEL and the Meteorological Measurement System (MMS) on NASA's ER-2 show AROTEL being from 2-3 K colder for altitudes ranging from 14 to 18 km. Temperature comparisons between AROTEL and the United Kingdom Meteorological Office's model showed differences of approximately 1 K below approximately 25 km and a very strong cold bias of approximately 12 K at altitudes between 30 and 35 km.

Burris, John↗

Impact of Uncertainties and Errors in Converting NWS Radiosonde Hygristor Resistances to Relative Humidity

A set of 2,600 6-second, National Weather Service soundings from NASA's FIRE-II Cirrus field experiment are used to illustrate previously known errors and new potential errors in the VIZ and SDD ) brand relative humidity (RH) sensors and the MicroART processing software. The entire spectrum of RH is potentially affected by at least one of these errors. (These errors occur before being converted to dew point temperature.) Corrections to the errors are discussed. Examples are given of the effect that these errors and biases may have on numerical weather prediction and radiative transfer. The figure shows the OLR calculated for the corrected and uncorrected soundings using an 18-band radiative transfer code. The OLR differences are sufficiently large to warrant consideration when validating line-by-line radiation calculations that use radiosonde data to specify the atmospheric state, or when validating satellite retrievals. in addition, a comparison of observations of RH during FIRE-II derived from GOES satellite, raman lidar, MAPS analyses, NCAR CLASS sondes, and the NWS sondes reveals disagreement in the RH distribution and underlines our lack of an understanding of the climatology of water vapor.

Westphal, Douglas L.↗

Impact of Uncertainties and Errors in Converting NWS Radiosonde Hygristor Resistances to Relative Humidity

A set of 2,600 6-second, National Weather Service soundings from NASA's FIRE-II Cirrus field experiment are used to illustrate previously known errors and new potential errors in the VIZ and SDD brand relative humidity (RH) sensors and the MicroART processing software. The entire spectrum of RH is potentially affected by at least one of these errors. (These errors occur before being converted to dew point temperature.) Corrections to the errors are discussed. Examples are given of the effect that these errors and biases may have on numerical weather prediction and radiative transfer. The figure shows the OLR calculated for the corrected and uncorrected soundings using an 18-band radiative transfer code. The OLR differences are sufficiently large to warrant consideration when validating line-by-line radiation calculations that use radiosonde data to specify the atmospheric state, or when validating satellite retrievals. In addition, a comparison of observations of RE during FIRE-II derived from GOES satellite, raman lidar, MAPS analyses, NCAR CLASS sondes, and the NWS sondes reveals disagreement in the RH distribution and underlines our lack of an understanding of the climatology of water vapor.

Westphal, Douglas L.↗

Stratospheric Analysis and Forecasting in the Northern Winter of 1999/2000: The NASA DAO's GEOS-3 System

An evaluation is presented of the performance in the northern winter 1999/2000 of the GEOS-3 troposphere-stratosphere data assimilation system (DAS). The impacts of the two main input data types are assessed: upper-air soundings (sondes) provide wind and temperature information and satellite-based (Tiros Operational Vertical Sounders: TOVS) give estimates of the thermal structure. It is shown that in the low stratosphere (300-70hPa) the analyses are generally slightly warmer than the sonde data, but colder than the TOVS data; this relationship reverses between 70 and 10 hPa. There are geographical biases, related to the spatial and temporal coverage of the observation types and to the statistical weights assigned to them in the DAS. Forecasts show a tendency to reduce zonal asymmetries in the atmospheric flow and to suppress stratospheric temperature minima. In the DAS, the analysis increments compensate for this, but it leads to important biases in the multi-day forecasts. The analysis increments are as large as the diabatic forcing in the lower polar stratosphere, indicating a substantial model bias. The results provide important insights into the roles of different data types and the circulation model in producing accurate analyses for studies of polar chemistry and physical processes.

Pawson, Steven↗

Investigation of the Short-Time Variability of Tropical Tropospheric Ozone

Since 1998, a ground based tropospheric ozone lidar has been running at Reunion Island and has been involved with a daily measurement campaign that was performed in the latter part of the biomass burning season, during November-December 1999. The averaged ozone profile obtained during November-December 1 999 agrees well with averaged ozone profile obtained from ozonesondes launch at Reunion during November-December (1992- 2001). Comparing weekly sonde launches (part of the Southern Hemisphere Additional Ozonesondes: SHADOZ program) with the daily ground-based lidar observations shows that some striking features of the day to day variability profiles are not observed in the sonde measurements. Ozone profiles respond to the nature of disturbances which vary from the one day to the next. The vertical ozone distribution at Reunion is examined as a function of prevailing atmospheric circulation. Backtrajectories show that most of the enhanced ozone crossed over biomass burning and convectively active regions in Madagascar and the southern African continent. The analyses of the meteorological data show that ozone stratification profiles are in agreement with the movement of the synoptical situations in November-December 1999. Three different sequences of transport are explained using wind fields. The first sequence from 23 to 25 November is characterized by Northerly transport, the second sequence from 26 to 30 November, the air masses are influenced by meridional transport. The third sequence from 2 to 6 December is characterized by westerly transport associated with the subtropical jet stream. The large standard deviations of lidar profiles in the middle and upper troposphere are in agreement with the upper wind variabilities which evidence passing ridge and trough disturbances. During the transition period between the dry season and the wet season, multiple ozone sources including stratosphere-troposphere exchanges, convection and biomass burning contribute to tropospheric ozone at Reunion Island through sporadic events characterized by a large spatial and temporal variability.

Randriambelo, Tantely↗

Impact of Flow-Dependent Error Correlations and Tropospheric Chemistry on Assimilated Ozone

The presentation compares different versions of a global three-dimensional ozone data assimilation system developed at NASA's Data Assimilation Office. The Solar Backscatter Ultraviolet/2 (SBUV/2) total and partial ozone column retrievals are the sole data assimilated in all of the experiments presented. We study the impact of changing the forecast error covariance model from a version assuming static correlations with a one that captures a short-term Lagrangian evolution of those correlations. This is further combined with a study of the impact of neglecting the tropospheric ozone production, loss and dry deposition rates, which are obtained from the Harvard GEOS-CHEM model. We compare statistical characteristics of the assimilated data and the results of validation against independent observations, obtained from WMO balloon-borne sondes and the Polar Ozone and Aerosol Measurement (POAM) III instrument. Experiments show that allowing forecast error correlations to evolve with the flow results in positive impact on assimilated ozone within the regions where data were not assimilated, particularly at high latitudes in both hemispheres. On the other hand, the main sensitivity to tropospheric chemistry is in the Tropics and sub-Tropics. The best agreement between the assimilated ozone and the in-situ sonde data is in the experiment using both flow-dependent error covariances and tropospheric chemistry.

Wargan, K.↗